914 resultados para Monitoring System
Evaluation of the Technicon block digestor system for total kjeldahl nitrogen and total phosphorus /
Resumo:
Issued Feb. 1978.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
"Presented at the 44th Annual Conference of the Water Pollution Control Federation, San Francisco, California (October, 1971)"--P. 1.
Resumo:
"EPA 814/B-96-004."
Resumo:
Mode of access: Internet.
Resumo:
Cover title.
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-06
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
We propose a model for non-ideal monitoring of the state of a coupled quantum dot qubit by a quantum tunnelling device. The non-ideality is modelled using an equivalent measurement circuit. This allows realistically available measurement results to be related to the state of the quantum system (qubit). We present a quantum trajectory that describes the stochastic evolution of the qubit state conditioned by tunnelling events (i.e. current) through the device. We calculate and compare the noise power spectra of the current in an ideal and a non-ideal measurement. The results show that when the two qubit dots are strongly coupled the non-ideal measurement cannot detect the qubit state precisely. The limitation of the ideal model for describing a realistic system maybe estimated from the noise spectra.
Resumo:
This paper investigates the input-output characteristics of structural health monitoring systems for composite plates based on permanently attached piezoelectric transmitter and sensor elements. Using dynamic piezoelectricity theory and a multiple integral transform method to describe the propagating and scattered flexural waves an electro-mechanical model for simulating the voltage input-output transfer function for circular piezoelectric transmitters and sensors adhesively attached to an orthotropic composite plate is developed. The method enables the characterization of all three physical processes, i.e. wave generation, wave propagation and wave reception. The influence of transducer, plate and attached electrical circuit characteristics on the voltage output behaviour of the system is examined through numerical calculations, both in frequency and the time domain. The results show that the input-output behaviour of the system is not properly predicted by the transducers' properties alone. Coupling effects between the transducers and the tested structure have to be taken into account, and adding backing materials to the piezoelectric elements can significantly improve the sensitivity of the system. It is shown that in order to achieve maximum sensitivity, particular piezoelectric transmitters and sensors need to be designed according to the structure to be monitored and the specific frequency regime of interest.
Resumo:
Background: The usefulness of umbilical artery Doppler velocimetry for the monitoring of diabetic pregnancies is controversial. The aim of the present study was to assess whether umbilical artery Doppler velocity waveform analysis can predict adverse perinatal outcomes for pregnancies complicated by pre-existing diabetes mellitus. Methods: All diabetic pregnancies (type 1 and 2) delivered at Mater Mothers' Hospital, Queensland, between 1 January 1995 and 31 December 1999 were included. All pregnant diabetic women were monitored with umbilical artery Doppler velocimetry at 28, 32, 36, and 38 weeks' gestation. Adverse perinatal outcome was defined as pregnancies with one or more of the following: small-for-gestational age, Caesarean section for non-reassuring cardiotocography, fetal acidaemia at delivery, 1-min Apgar of 3 or less, 5-min Apgar of less than 7, hypoxic ischaemic encephalopathy or perinatal death. Abnormal umbilical artery Doppler velocimetry was defined as a pulsatility index of 95th centile or higher for gestation. Results: One hundred and four pregnancies in women with pre-existing diabetes had umbilical arterial Doppler studies carried out during the study period. Twenty-three pregnancies (22.1%) had an elevated pulsatility index. If the scans were carried out within 2 weeks of delivery, 71% of pregnancies with abnormal umbilical Doppler had adverse outcomes (P < 0.01; likelihood ratio, 4.2). However, the sensitivity was 35%; specificity was 94%; positive predictive value was 80%; and negative predictive value was 68%. Only 30% of women with adverse perinatal outcomes had abnormal umbilical arterial Doppler flow. Conclusion: Umbilical artery Doppler velocimetry is not a good predictor of adverse perinatal outcomes in diabetic pregnancies.
Resumo:
In wildlife management, the program of monitoring will depend on the management objective. If the objective is damage mitigation, then ideally it is damage that should be monitored. Alternatively, population size (N) can be used as a surrogate for damage, but the relationship between N and damage obviously needs to be known. If the management objective is a sustainable harvest, then the system of monitoring will depend on the harvesting strategy. In general, the harvest strategy in all states has been to offer a quota that is a constant proportion of population size. This strategy has a number of advantages over alternative strategies, including a low risk of over- or underharvest in a stochastic environment, simplicity, robustness to bias in population estimates and allowing harvest policy to be proactive rather than reactive. However, the strategy requires an estimate of absolute population size that needs to be made regularly for a fluctuating population. Trends in population size and in various harvest statistics, while of interest, are secondary. This explains the large research effort in further developing accurate estimation methods for kangaroo populations. Direct monitoring on a large scale is costly. Aerial surveys are conducted annually at best, and precision of population estimates declines with the area over which estimates are made. Management at a fine scale (temporal or spatial) therefore requires other monitoring tools. Indirect monitoring through harvest statistics and habitat models, that include rainfall or a greenness index from satellite imagery, may prove useful.