1000 resultados para Microscópio óptico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, the project of a new experimental facility to be installed at the Aerodynamics Division of the Institute of Aeronautics and Space is presented. This new facility will provide means to perform experimental campaigns to analyze the flow behavior at different rocket nozzle concepts using cold gas that will be obtained from a modification of the Pilot Transonic Wind Tunnel air system. The new installation will enable less expensive experiments in a more secure environment, since the cold gas experimental procedures do not demand fuel storage and burn and security procedures are much less severe. Furthermore, experiments can be carried with different types of sensors, commonly used in wind tunnel tests. Also, the optical access is facilitated enabling the use of optical techniques for the characterization of flow properties inside the nozzles, such as pressure and temperature sensitive painting. The full project design and the operation conditions will be showed, as also some technical considerations about the flor behavior in the facility

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, the project of a new experimental facility to be installed at the Aerodynamics Division of the Institute of Aeronautics and Space is presented. This new facility will provide means to perform experimental campaigns to analyze the flow behavior at different rocket nozzle concepts using cold gas that will be obtained from a modification of the Pilot Transonic Wind Tunnel air system. The new installation will enable less expensive experiments in a more secure environment, since the cold gas experimental procedures do not demand fuel storage and burn and security procedures are much less severe. Furthermore, experiments can be carried with different types of sensors, commonly used in wind tunnel tests. Also, the optical access is facilitated enabling the use of optical techniques for the characterization of flow properties inside the nozzles, such as pressure and temperature sensitive painting. The full project design and the operation conditions will be showed, as also some technical considerations about the flor behavior in the facility

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

(Pollen morphology of the genus Eremanthus Less. (Vernonieae, Asteraceae)). In order to evaluate the significance of the pollen morphology for generic and infrageneric taxonomy of the genus Eremanthus (Vernonieae, Asteraceae), and to provide additional data for its phylogenetic reconstruction, the pollen of 20 of the 23 species of the genus was examined using light and scanning electron microscopy. Acetolysed pollen grains were measured, described, and illustrated using light microscopy, while non-acetolysed pollen grains were analyzed using scanning electron microscopy. Pollen grains of these species are isopolar, oblate-spheroidal in most of the species, more rarely prolate spheroidal or suboblate, subtriangular amb, tricolporate and subechinolophate. The variation among quantitative characters does not correlate with the macromorphological subdivision of the genus or with the generic or specific limits.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O desenvolvimento científico nos permite trabalhar hoje com gases em temperaturas muito inferiores aos 10-6 K. Estes gases, uma vez obtidos por técnicas de resfriamento óptico, precisam ser caracterizados com relaçãao às suas propriedades termodinâmicas. a a medida da temperatura. Dentre tais propriedades está a medida da temperatura. Neste trabalho mostramos de forma tutorial como são medidas tais baixas temperaturas, através de técnicas de tempo de voo. Tais técnicas combinam conhecimento básico de mecânica, termodinâmica dentre outros tópicos convencionalmente estudados nos cursos básicos de física.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXTUALIZAÇÃO: A biofotogrametria é uma técnica difundida na área da saúde e, apesar dos cuidados metodológicos, há distorções nas leituras angulares das imagens fotográficas. OBJETIVO: Mensurar o erro das medidas angulares em imagens fotográficas com diferentes resoluções digitais em um objeto com ângulos pré-demarcados. MÉTODOS: Utilizou-se uma esfera de borracha com 52 cm de circunferência. O objeto foi previamente demarcado com ângulos de 10º, 30º, 60º e 90º, e os registros fotográficos foram realizados com o eixo focal da câmera a três metros de distância e perpendicular ao objeto, sem utilização de zoom óptico e com resolução de 3, 5 e 10 Megapixels (Mp). Todos os registros fotográficos foram armazenados, e os valores angulares foram analisados por um experimentador previamente treinado, utilizando o programa ImageJ. As aferições das medidas foram realizadas duas vezes, com intervalo de 15 dias entre elas. Posteriormente, foram calculados os valores de acurácia, erro relativo e em graus, precisão e Coeficiente de Correlação Intraclasse (ICC). RESULTADOS: Quando analisado o ângulo de 10º, a média da acurácia das medidas foi maior para os registros com resolução de 3 Mp em relação às resoluções de 5 e 10 Mp. O ICC foi considerado excelente para as três resoluções de imagem analisadas e, em relação aos ângulos analisados nos registros fotográficos, pôde-se verificar maior acurácia, menor erro relativo e em graus e maior precisão para o ângulo de 90º, independentemente da resolução da imagem. CONCLUSÃO: Os registros fotográficos realizados com a resolução de 3 Mp proporcionaram medidas de maiores valores de acurácia e precisão e menores valores de erro, sugerindo ser a resolução mais adequada para gerar imagem de ângulos de 10º e 30º.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the retinal nerve fiber layer measurements with time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT), and to test the diagnostic ability of both technologies in glaucomatous patients with asymmetric visual hemifield loss. Methods: 36 patients with primary open-angle glaucoma with visual field loss in one hemifield (affected) and absent loss in the other (non-affected), and 36 age-matched healthy controls had the study eye imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, California, USA) and 3 D OCT-1000 (Topcon, Tokyo, Japan). Peripapillary retinal nerve fiber layer measurements and normative classification were recorded. Total deviation values were averaged in each hemifield (hemifield mean deviation) for each subject. Visual field and retinal nerve fiber layer "asymmetry indexes" were calculated as the ratio between affected versus non-affected hemifields and corresponding hemiretinas. Results: Retinal nerve fiber layer measurements in non-affected hemifields (mean [SD] 87.0 [17.1] mu m and 84.3 [20.2] mu m, for TD and SD-OCT, respectively) were thinner than in controls (119.0 [12.2] mu m and 117.0 [17.7] mu m, P<0.001). The optical coherence tomography normative database classified 42% and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P=0.01). Retinal nerve fiber layer measurements were consistently thicker with TD compared to SD-OCT. Retinal nerve fiber layer thickness asymmetry index was similar in TD (0.76 [0.17]) and SD-OCT (0.79 [0.12]) and significantly greater than the visual field asymmetry index (0.36 [0.20], P<0.001). Conclusions: Normal hemifields of glaucoma patients had thinner retinal nerve fiber layer than healthy eyes, as measured by TD and SD-OCT. Retinal nerve fiber layer measurements were thicker with TD than SD-OCT. SD-OCT detected abnormal retinal nerve fiber layer thickness more often than TD-OCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O artigo apresenta a caraterização e a análise dos ladrilhos utilizados em construções do século XVIII, na cidade de Paranaguá, no Estado do Paraná, avaliando principalmente sua composição química. Através da análise de microscópio eletrônico de varredura foi possível coletar informações que permitiram interpretações sobre a composição dessas peças. Em Paranaguá, grande parte das edificações setecentistas possui paredes em alvenaria de pedra enquanto a utilização desses ladrilhos esteve restrita às estruturas dos quadros de portas e janelas, como alternativa às vergas e umbrais de cantaria ou madeira usados em construções até a primeira metade do século XIX. Algumas ruínas existentes no centro histórico revelam fortes indícios dos materiais empregados, modo de assentamento e dimensões desses ladrilhos. Essas peças são mais delgadas do que os tijolos, ressaltando que estes elementos foram bastante empregados a partir da segunda metade do século XIX. Observando os ladrilhos a olho nu, é possível verificar a variedade de agregados que compõem as argilas. Sendo assim, este trabalho é uma contribuição para a história dos materiais e das técnicas construtivas da cidade de Paranaguá e sua relação de influências com a metrópole portuguesa, ao mesmo tempo em que permitiu apropriações e adaptações locais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVOS: Avaliar a histomorfometria das células intersticiais dos ovários, bem como analisar a concentração sanguínea de esteroides sexuais de ratas portadoras de ovários policísticos induzidos pela luz contínua. MÉTODOS: Vinte ratas foram divididas em dois grupos: ratas na fase de estro (GCtrl ) e ratas portadoras de ovários policísticos induzidos pela iluminação contínua (GOP). Os animais do GCtrl permaneceram com período de luz das 7:00 s 19:00 horas, e os animais do GOP, com iluminação contínua (400 Lux), durante um período de 60 dias. Ao final desse período todos os animais foram anestesiados, foi coletado o sangue, para determinação dos níveis séricos de estradiol (E2), progesterona (P4) e testosterona (T), seguido da retirada dos ovários que foram fixados em formol a 10% e processados para inclusão em parafina. Cortes histológicos com 5 µm corados pela hematoxilina e eosina foram utilizados para análise histomorfométrica. As análises morfológicas, contagem de cistos, determinação da concentração e do volume nuclear das células intersticiais foram realizadas com o auxílio de microscópio de luz adaptado a uma câmera de alta resolução (AxioCam), cujas imagens foram transmitidas e analisadas em computador com software AxioVision Rel 4.8 (Carl Zeiss). Os dados obtidos foram submetidos ao teste t de Student (p<0,05). RESULTADOS: A morfologia mostrou a presença de cistos nos ovários pertencentes ao Grupo OP e de corpos lúteos no GCtrl, mostrando ainda evidências da origem das células intersticiais a partir das células da teca interna desses cistos. Com relação aos níveis hormonais o GOP apresentou níveis séricos de estradiol (pg/mL) aumentados em relação ao GCtrl (GOP=124,9±4,2>GCtrl=73,2±6,5; p<0,05), o mesmo ocorrendo com os níveis de testosterona (pg/mL) (GOP=116,9±4,6>GCtrl=80,6±3,9; p<0,05). Entretanto os níveis de progesterona (ng/mL) foram mais elevados no GCtrl em relação ao GOP (GCtrl=16,3±2,0>GOP=4,2±1,5; p<0,05). A morfometria mostrou haver aumento significante do volume nuclear no grupo GOP (GOP=102,1±5,2>GCtrl=63,6±16,5; p<0,05), assim como da área ocupada (%) pelas células intersticiais (GOP=24,4±6,9>GCtrl=6,9±3,2; p<0,05) em relação aos animais do GCtrl. CONCLUSÃO: As células intersticiais do ovário policístico da rata provavelmente provêm dos cistos ovarianos devido degeneração das células da granulosa e diferenciação das células da teca interna. As elevações dos níveis séricos de testosterona e de estradiol provavelmente provêm do aumento significativo da atividade celular e da área ocupada pelas células intersticiais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVOS: Avaliar a morfologia dos cardiomiócitos e quantificar o colágeno presente no miocárdio de ratas tratadas com extrato concentrado de soja ou 17β-estradiol (E2). MÉTODOS: Vinte e oito ratas foram divididas em quatro grupos: GCtrl - fase de estro; GOvx - ovariectomizadas (Ovx); GIso - Ovx tratadas com extrato de soja (150 mg/kg, por dia); GE2 - Ovx tratadas com E2 (10 µg/kg, por dia). As drogas e o veículo (0,2 mL de propilenoglicol) foram administrados após 30 dias da realização da ovariectomia, por 30 dias consecutivos. No último dia os animais foram anestesiados, o coração retirado, mergulhado em formaldeído a 10%, e fragmentos dos ventrículos submetidos a processamento histológico, sendo os cortes corados pela hematoxilina e eosina ou pelo picrosirius-red. As análises histomorfométricas (contagem, volume nuclear e quantificação do colágeno) foram realizadas em microscópio de luz e software AxioVision Rel. 4.2, sendo o colágeno determinado pelo programa Imagelab 2000. Os dados foram submetidos ao teste de ANOVA complementado pelo teste de Tukey (p<0,05). RESULTADOS: Notamos maior quantidade de núcleos de cardiomiócitos nos animais dos grupos Ovx e Iso do que no GE2 e GCtrl (GOvx=121,7±20,2=GIso=92,8±15,4>GE2=70,5±14,8=GCtrl=66,3±9,6; p<0,05), sendo o volume nuclear maior nos animais do grupo Ctrl e E2 (GE2=35,7±4,8=GCtrl=29,9±3,6>GIso=26,5±4,5=GOvx=22,4±2,9; p<0,05). Com relação ao colágeno notamos maior concentração no grupo Ovx (GOvx=5,4±0,1>GCtrl=4,0±0,1=GIso=4,4±0,08=GE2=4,3±0,5; p<0,05). CONCLUSÕES: Os estrogênios previnem a diminuição do volume nuclear dos cardiomiócitos e a deposição de colágeno entre as fibras musculares cardíacas. Já a administração de isoflavonas previne somente a deposição de colágeno, o que pode preservar as propriedades mecânicas das fibras cardíacas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neste trabalho é proposto um fotômetro baseado em LED (diodo emissor de luz) para fotometria em fase sólida. O fotômetro foi desenvolvido para permitir o acoplamento da fonte de radiação (LED) e do fotodetector direto na cela de fluxo, tendo um caminho óptico de 4 mm. A cela de fluxo foi preenchida com material sólido (C18), o qual foi utilizado para imobilizar o reagente cromogênico 1-(2-tiazolilazo)-2-naftol (TAN). A exatidão foi avaliada empregando dados obtidos através da técnica ICP OES (espectrometria de emissão por plasma indutivamente acoplado). Aplicando-se o teste-t pareado não foi observada diferença significativa em nível de confiança de 95%. Outros parâmetros importantes encontrados foram faixa de resposta linear de 0,05 a 0,85 mg L-1 Zn, limite de detecção de 9 µg L-1 Zn (n = 3), desvio padrão de 1,4 % (n = 10), frequência de amostragem de 36 determinações por h, e uma geração de efluente e consumo de reagente de 1,7 mL e 0,03 µg por determinação, respectivamente.