933 resultados para Microbial loop
Resumo:
Introduction: Denture stomatitis is a common lesion that affects denture wearers. Its multifactorial etiology seems to depend on a complex and poorly characterized biofilm. The purpose of this study was to assess the composition of the microbial biofilm obtained from complete denture wearers with and without denture stomatitis using culture-independent methods.Methods: Samples were collected from healthy denture wearers and from patients with denture stomatitis. Libraries comprising about 600 cloned 16S ribosomal DNA (rDNA) bacterial sequences and 192 cloned eukaryotic internal transcribed spacer (ITS) region sequences, obtained by polymerase chain reactions, were analyzed.Results: The partial 16S rDNA sequences revealed a total of 82 bacterial species identified in healthy subjects and patients with denture stomatitis. Twenty-seven bacterial species were detected in both biofilms, 29 species were exclusively present in patients with denture stomatitis, and 26 were found only in healthy subjects. Analysis of the ITS region revealed the presence of Candida sp. in both biofilms.Conclusion: The results revealed the extent of the microbial flora, suggesting the existence of distinct biofilms in healthy subjects and in patients with denture stomatitis.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: The aim of this study was to compare the microbial leakage of mineral trioxide aggregate (MTA), Portland cement (PC), Sealapex and zinc oxide-eugenol (ZOE) as root-end filling materials.Study design: An in vitro microbial leakage test (MLT) with a split chamber was used in this study. A mixture of facultative bacteria and one yeast (S. aureus + E. faecalis + P. aeruginosa + B. subtilis + C. albicans) was placed in the upper chamber and it could only reach the lower chamber containing Brain Heart Infusion broth by way of leakage through the root-end filling. Microbial leakage was observed daily for 60 days. Sixty maxillary anterior human teeth were randomly assigned to different groups - MTA and PC (gray and white), Sealapex + zinc oxide and ZOE, control groups and subgroups to evaluate the influence of EDTA for smear layer removal. These materials were further evaluated by an agar diffusion test (ADT) to verify their antimicrobial efficacy. Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney test.Results: In the MLT, Sealapex + zinc oxide and ZOE did not show evidence of microbial leakage over the 60-day experimental period. The other materials showed leakage from the 15th day. The presence of smear layer influenced microbial leakage. Microbial inhibition zones were not observed in all samples tested by ADT.Conclusion: Sealapex + zinc oxide and ZOE did not show microbial leakage over the experimental period, whereas it was verified within 15 to 45 days in MTA and Portland cement.
Resumo:
Introduction: The purpose of this study was to use photoelastic analysis to compare the system of forces generated by retraction T-loop springs made with stainless steel and titanium-molybdenum alloy (TMA) (Ormco, Glendora, Calif) with photoelastic analysis. Methods: Three photoelastic models were used to evaluate retraction T-loop springs with the same preactivations in 2 groups. In group 1, the loop was constructed with a stainless steel wire, and 2 helicoids were incorporated on top of the T-loop; in group 2, it was made with TMA and no helicoids. Results: Upon using the qualitative analysis of the fringe order in the photoelastic model, it was observed that the magnitude of force generated by the springs in group 1 was significantly higher than that in group 2. However, both had symmetry for the active and reactive units related to the system of force. Conclusions: Both springs had the same mechanical characteristics. TMA springs showed lower force levels. (Am J Orthod Dentofacial Orthop 2011;140:e123-e128)
Resumo:
Objective: To compare the system of forces acting on curvature and preactivated V-bends in titanium T-loop springs (TTLSs) made of 0.017- X 0.025-inch TMA (titanium molibdenium alloy) wire.Materials and Methods: Pictures of TTLSs preactivated by curvature and V-bends were inserted in the LOOP software program to design both TTLSs. Symmetry was assured using the program. Both TTLSs used the same amount (length) of wire and had the same angulation between their anterior and posterior extremities when passive. The loops were activated 7 mm, and forces and moments were registered after each 0.5 mm of deactivation. The brackets were at the same height, separated by 23 mm and angulated 0 degrees.Results: The preactivated curvature TTLS delivered horizontal forces ranging from 34 gF to 456 gF, while the TTLS preactivated by V-bends delivered forces ranging from 54 gF to 517 gF. The forces decreased more (30 gF vs 33 gF) with every 0.5 mm of activation on the preactivated V-bend TTLS than on the preactivated curvature TTLS. Vertical forces were low and clinically insignificant for both TTLSs. The moment to force (MF) ratios were systematically higher on the preactivated curvature than on the preactivated V-bend TTLS (from 5.8 mm to 38.8 mm vs 4.7 mm to 28.3 mm).Conclusions: Although both loops show symmetrical moments in their anterior and posterior extremities and can be used for group B anchorage, the curvature preactivated TTLS delivers lower horizontal forces and higher MF ratios than the acute preactivated V-bend TTLS.
Resumo:
ATMA (Ormco Corp, Glendora, Calif) T-loop spring (TTLS), preactivated with a gable bend distal to the loop, holds promise for producing controlled tipping of the canines and translation of the posterior segment. However, there is currently no consensus as to where the preactivated gable bend or the loop should be placed, what the height of the loop should be, or how the interbracket distance changes the moments produced. Using the Loop software program (dHal, Athens, Greece), we systematically modified a .017 x .025-in TTLS (10 x 6 mm) that was preactivated with a 45 degrees gable bend distal to the loop, and simulated the effects. As the gable bend was moved posteriorly, the moment increased at the posterior bracket more than it decreased at the anterior bracket. As the loop was brought closer to the anterior bracket, the posterior moment decreased at the same rate that it increased anteriorly. As the loop was increased in size, the moments increased both posteriorly and anteriorly. As the interbracket distance increased, the posterior moment decreased, and the anterior moment remained constant. We concluded that the size of the loop should be slightly increased, to 10 x 7 mm, and it should be placed 2 mm from the anterior bracket, with a preactivation bend of 45 degrees, 4 to 5 mm from the posterior bracket (after 4 mm of activation).
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this work we calculate two two-loop massless Feynman integrals pertaining to self-energy diagrams using NDIM (Negative Dimensional Integration Method). We show that the answer we get is 36-fold degenerate. We then consider special cases of exponents for propagators and the outcoming results compared with known ones obtained via traditional methods.
Resumo:
The negative-dimensional integration method (NDIM) seems to be a very promising technique for evaluating massless and/or massive Feynman diagrams. It is unique in the sense that the method gives solutions in different regions of external momenta simultaneously. Moreover, it is a technique whereby the difficulties associated with performing parametric integrals in the standard approach are transferred to a simpler solving of a system of linear algebraic equations, thanks to the polynomial character of the relevant integrands. We employ this method to evaluate a scalar integral for a massless two-loop three-point vertex with all the external legs off-shell, and consider several special cases for it, yielding results, even for distinct simpler diagrams. We also consider the possibility of NDIM in non-covariant gauges such as the light-cone gauge and do some illustrative calculations, showing that for one-degree violation of covariance (i.e. one external, gauge-breaking, light-like vector n μ) the ensuing results are concordant with the ones obtained via either the usual dimensional regularization technique, or the use of the principal value prescription for the gauge-dependent pole, while for two-degree violation of covariance - i.e. two external, light-like vectors n μ, the gauge-breaking one, and (its dual) n * μ - the ensuing results are concordant with the ones obtained via causal constraints or the use of the so-called generalized Mandelstam-Leibbrandt prescription. © 1999 Elsevier Science B.V.
Resumo:
In recent years, many researchers in the field of biomedical sciences have made successful use of mathematical models to study, in a quantitative way, a multitude of phenomena such as those found in disease dynamics, control of physiological systems, optimization of drug therapy, economics of the preventive medicine and many other applications. The availability of good dynamic models have been providing means for simulation and design of novel control strategies in the context of biological events. This work concerns a particular model related to HIV infection dynamics which is used to allow a comparative evaluation of schemes for treatment of AIDS patients. The mathematical model adopted in this work was proposed by Nowak & Bangham, 1996 and describes the dynamics of viral concentration in terms of interaction with CD4 cells and the cytotoxic T lymphocytes, which are responsible for the defense of the organism. Two conceptually distinct techniques for drug therapy are analyzed: Open Loop Treatment, where a priori fixed dosage is prescribed and Closed Loop Treatment, where the doses are adjusted according to results obtained by laboratory analysis. Simulation results show that the Closed Loop Scheme can achieve improved quality of the treatment in terms of reduction in the viral load and quantity of administered drugs, but with the inconvenience related to the necessity of frequent and periodic laboratory analysis.
Resumo:
We investigate the possibility that four-fermion contact interactions give rise to the observed deviation from the standard model prediction for the weak charge of cesium, through one-loop contributions. We show that the presence of loops involving the third generation quarks can explain such a deviation.