985 resultados para Matrices genéricas


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Los análisis de Fourier permiten caracterizar el contorno del diente a partir de un número determinado de puntos y extraer una serie de parámetros para un posterior análisis multivariante. No obstante, la gran complejidad que presentan algunas conformaciones, obliga a comprobar cuántos puntos son necesarios para una correcta representación de ésta. El objetivo de este trabajo es aplicar y validar los análisis de Fourier (Polar y Elíptico) en el estudio de la forma dental a partir de diferentes puntos de contorno y explorar la variabilidad morfométrica en diferentes géneros. Se obtuvieron fotografías digitales de la superfi cie oclusal en segundos molares inferiores (M2s) de 4 especies de Primates (Hylobates moloch, Gorilla beringei graueri, Pongo pygmaeus pygmaeus y Pan troglodytes schweirfurthii) y se defi nió su contorno con 30, 40, 60, 80, 100 y 120 puntos y su representación formal a 10 armónicos. El análisis de la variabilidad morfométrica se realizó mediante la aplicación de Análisis Discriminantes y un NP-MANOVA a partir de matrices de distancias para determinar la variabilidad y porcentajes de clasifi cacióncorrecta, a nivel metodológico y taxonómico. Los resultados indicaron que los análisis de forma con series de Fourier permiten analizar la variabilidad morfométrica de M2s en géneros de Hominoidea, con independencia del número de puntos de contorno (30 a 120). Los porcentajes de clasifi cación son más variables e inferiores con el uso de la serie Polar (≈60-90) que con la Elíptica (75-100%). Un número entre 60-100 puntos de contorno mediante el método elíptico garantiza una descripción correcta de la forma del diente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabajo persigue dos objetivos: el primero es analizar el uso de las TIC en un grupo de estudiantes de segundo curso de Magisterio de la Universidad de Girona; el segundo es analizar los documentos normativos legales que establecen el currículum de educación primaria en Cataluña para observar qué tipo de papel juegan las TIC en las nuevas programaciones educativas. La primera parte se ha llevado a cabo mediante una encuesta, cuyos resultados permiten observar tres aspectos distintos: el primero, que una parte considerable del grupo considera las TIC más como un complemento para el aprendizaje que como una forma de aprendizaje; el segundo, que a pesar de hacer un uso considerable de las TIC, el conocimiento que tienen de ellas es muy básico y utilizan aplicaciones muy genéricas; y el tercero es que una parte de sus propuestas didácticas para el uso de las TIC son propuestas tradicionales simplemente adaptadas a un nuevo instrumento, sin buscar realmente la innovación que puede suponer la incorporación de las TIC. En la segunda parte del artículo, a partir del análisis e interpretación de los documentos legales que establecen el currículum de Educación Primaria, se observa que en un mismo documento conviven aserciones sobre las TIC como complemento al aprendizaje de contenidos con otras formulaciones que consideran las TIC como constructoras de conocimiento. A partir del perfil de los estudiantes y del estado de los documentos legales, al final del artículo se hacen propuestas para formar al futuro maestro teniendo en cuenta las TIC como herramientas básicas de conocimiento

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) encompasses a number of characteristics quite suitable for the simultaneous analysis of small ions such as high efficiency and resolving power, directly associated to its impressively high peak capacity, and short analysis time. In appropriate conditions, it is possible to perform the separation of approximately 36 anions in less than 3 minutes. In this work, the mechanisms by which anion analysis is performed was criteriously discussed, and a thorough review of the literature in the past 5 years, focusing mostly in applications of CE to anion analysis in real matrices, was presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several hundreds of artificial radionuclides are produced as the result of human activities, such as the applications of nuclear reactors and particle accelerators, testing of nuclear weapons and nuclear accidents. Many of these radionuclides are short-lived and decay quickly after their production, but some of them are longer-lived and are released into the environment. From the radiological point of view the most important radionuclides are cesium-137, strontium-90 and plutonium-239, due to their chemical and nuclear characteristics. The two first radioisotopes present long half life (30 and 28 years), high fission yields and chemical behaviour similar to potassium and calcium, respectively. No stable element exists for plutonium-239, that presents high radiotoxicity, long half-life (24000 years) and some marine organisms accumulate plutonium at high levels. The radionuclides introduced into marine environment undergo various physical, chemical and biological processes taking place in the sea. These processes may be due to physical dispersion or complicated chemical and biological interactions of the radionuclides with inorganic and organic suspend matter, variety of living organisms, bottom sediments, etc. The behaviour of radionuclides in the sea depends primarily on their chemical properties, but it may also be influenced by properties of interacting matrices and other environmental factors. The major route of radiation exposure of man to artificial radionuclides occuring in the marine environment is through ingestion of radiologically contamined marine organisms. This paper summarizes the main sources of contamination in the marine environment and presents an overview covering the oceanic distribution of anthropogenic radionuclides in the FAO regions. A great number of measurements of artificial radionuclides have been carried out on various marine environmental samples in different oceans over the world, being cesium-137 the most widely measured radionuclide. Radionuclide concentrations vary from region to region, according to the specific sources of contamination. In some regions, such as the Irish Sea, the Baltic Sea and the Black Sea, the concentrations depend on the inputs due to discharges from reprocessing facilities and from Chernobyl accident. In Brazil, the artificial radioactivity is low and corresponds to typical deposition values due to fallout for the Southern Hemisphere.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the selective hydrolysis of carboxyamide groups of asparagine and glutamine of collagen matrices for the preparation of negatively charged collagen biomaterials. The reaction was performed in the presence of chloride and sulfate salts of alkaline and alkaline earth metals in aqueous dimethylsulfoxide solution and, selectively hydrolysis of carboxyamide groups of collagen matrices was promoted without cleavage of the peptide bond. The result is a new collagen material with controlled increase in negative charge content. Although triple helix secondary structure of tropocollagen was preserved, significative changes in thermal stabilities were observed in association with a new pattern of tropocollagen macromolecular association, particularly in respect microfibril assembly, thus providing at physiological pH a new type of collagen structure for biomaterial preparation, characterized by different charge and structural contents .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Changes in the angle of illumination incident upon a 3D surface texture can significantly alter its appearance, implying variations in the image texture. These texture variations produce displacements of class members in the feature space, increasing the failure rates of texture classifiers. To avoid this problem, a model-based texture recognition system which classifies textures seen from different distances and under different illumination directions is presented in this paper. The system works on the basis of a surface model obtained by means of 4-source colour photometric stereo, used to generate 2D image textures under different illumination directions. The recognition system combines coocurrence matrices for feature extraction with a Nearest Neighbour classifier. Moreover, the recognition allows one to guess the approximate direction of the illumination used to capture the test image

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last years, the use of antibody-antigen interactions, has earned attention not only for clinical analysis, but also for food industry and environmental control. Since the scope and diversity of immunoassay technology have shown a wide development. Continuous advances in order to analyse complex matrices, to improve reliability, simplicity (nonseparation) and to get multiple simultaneous assays, and extreme sensitivity (lower than zeptomole detection limits) are increasing. Many strategies have been investigated including chemiluminescent enzyme immunoassays, DNA as label and development of flow injection and immunosensors techniques. This subject became very usefull and important in nowadays that are taught in the undergraduate courses of chemistry in the european universities. However in our country are still ignored in the chemistry course.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper provides a review on separation methods and analytical techniques for the determination of several species of organic and inorganic arsenic in different matrices. Arsenic is an element whose speciation is of particular interest due to the great variation of toxicity levels exhibited for its different chemical forms. Arsenic (III) and As (V) are the most toxic species while organic compounds such as arsenobetaine (AsB), produced by methylation of inorganics species (carcinogenics) are relatively less toxic, hence the great importance of arsenic speciation in the determination of the degree of contamination of an environmental or biological system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review discusses the methods used to prepare conductive polymers in confined environments. This spatial restriction causes formation of defect-free polymer chains in the interlayer as porous cavities of inorganic hosts. The properties of the different composites obtained are a synergist combination of the characteristics of the inorganic host and the polymer. This opens new perspectives for the preparation of these materials and widens its potential applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Needle trap devices (NTDs) are a relatively new and promising tool for headspace (HS) analysis. In this study, a dynamic HS sampling procedure is evaluated for the determination of volatile organic compounds (VOCs) in whole blood samples. A full factorial design was used to evaluate the influence of the number of cycles and incubation time and it is demonstrated that the controlling factor in the process is the number of cycles. A mathematical model can be used to determine the most appropriate number of cycles required to adsorb a prefixed amount of VOCs present in the HS phase whenever quantitative adsorption is reached in each cycle. Matrix effect is of great importance when complex biological samples, such as blood, are analyzed. The evaluation of the salting out effect showed a significant improvement in the volatilization of VOCs to the HS in this type of matrices. Moreover, a 1:4 (blood:water) dilution is required to obtain quantitative recoveries of the target analytes when external calibration is used. The method developed gives detection limits in the 0.020–0.080 μg L−1 range (0.1–0.4 μg L−1 range for undiluted blood samples) with appropriate repeatability values (RSD < 15% at high level and <23% at LOQ level). Figure of merits of the method can be improved by using a smaller phase ratio (i.e., an increase in the blood volume and a decrease in the HS volume), which lead to lower detection limits, better repeatability values and greater sensibility. Twenty-eight blood samples have been evaluated with the proposed method and the results agree with those indicated in other studies. Benzene was the only target compound that gave significant differences between blood levels detected in volunteer non-smokers and smokers

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, the analysis of cations by capillary electrophoresis is reviewed from the theoretical and practical point of view. Separation mechanisms and detection modes are discussed and illustrated. A thorough compilation of the literature over the last ten years, regarding applications of the technique to the analysis of cations in real matrices, is presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The adsorption of triadimenol (1-(4-chlorophenoxy)-3,3-dimethyl-1-(1H-1,2,4-triazol-1-yl)butan-2-ol) on soil samples with varying contents of organic matter was studied. The adsorption was described by means of the Freundlich's isoterm. An increase in the capacity of adsorption was observed as the content of organic carbon in the matrix increased. That effect was observed when removing the organic matter from the soil, when adding a urban waste compost to the soil sample as well as to the soil sample without organic matter, and also after leaving proportions of urban waste compost incubated in these matrices for a period of 120 days. The results show that the adsorption of the triadimenol in the soil is dependent of its content of organic carbon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to explore the possibility of the application of a non-ionic resin obtained by impregnation of Alizarin Red S (VAS) in Amberlite XAD-7 for manganese, copper and zinc separation and preconcentration in saline matrices. For these system, the metals were quantitatively retained, in the pH range 8.5-10.0, by using 0.50 g of solid phase, stirring time of five minutes and a total mass up to 200 mug of each cation. The sorbed elements were subsequently eluted and a fifty-fold, ten-fold and ten-fold preconcentration factor for to Zn, Cu and Mn were obtained, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The central goal of food safety policy in the European Union (EU) is to protect consumer health by guaranteeing a high level of food safety throughout the food chain. This goal can in part be achieved by testing foodstuffs for the presence of various chemical and biological hazards. The aim of this study was to facilitate food safety testing by providing rapid and user-friendly methods for the detection of particular food-related hazards. Heterogeneous competitive time-resolved fluoroimmunoassays were developed for the detection of selected veterinary residues, that is coccidiostat residues, in eggs and chicken liver. After a simplified sample preparation procedure, the immunoassays were performed either in manual format with dissociation-enhanced measurement or in automated format with pre-dried assay reagents and surface measurement. Although the assays were primarily designed for screening purposes providing only qualitative results, they could also be used in a quantitative mode. All the developed assays had good performance characteristics enabling reliable screening of samples at concentration levels required by the authorities. A novel polymerase chain reaction (PCR)-based assay system was developed for the detection of Salmonella spp. in food. The sample preparation included a short non-selective pre-enrichment step, after which the target cells were collected with immunomagnetic beads and applied to PCR reaction vessels containing all the reagents required for the assay in dry form. The homogeneous PCR assay was performed with a novel instrument platform, GenomEra, and the qualitative assay results were automatically interpreted based on end-point time-resolved fluorescence measurements and cut-off values. The assay was validated using various food matrices spiked with sub-lethally injured Salmonella cells at levels of 1-10 colony forming units (CFU)/25 g of food. The main advantage of the system was the exceptionally short time to result; the entire process starting from the pre-enrichment and ending with the PCR result could be completed in eight hours. In conclusion, molecular methods using state-of-the-art assay techniques were developed for food safety testing. The combination of time-resolved fluorescence detection and ready-to-use reagents enabled sensitive assays easily amenable to automation. Consequently, together with the simplified sample preparation, these methods could prove to be applicable in routine testing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The great utilization of synthetic and persistent xenobiotic cumulative compounds is the main causes of the deterioration of aquatic ecosystems. The one of objective of this work was the determination of the organochlorine levels in the Piracicaba river basin, situated at the center of São Paulo state. Four PCBs congeners, PCP and HCB were determined by GC-ECD in two different matrices: water and sediments. The pattern of the compound distribution indicated a dominance of PCP, HCB and PCB-200. The results indicated contamination in the sampling points located in Campinas, Piracicaba, Santa Bárbara d'Oeste and Sumaré cities.