958 resultados para Limit-periodic


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Synchronization plays an important role in telecommunication systems, integrated circuits, and automation systems. Formerly, the masterslave synchronization strategy was used in the great majority of cases due to its reliability and simplicity. Recently, with the wireless networks development, and with the increase of the operation frequency of integrated circuits, the decentralized clock distribution strategies are gaining importance. Consequently, fully connected clock distribution systems with nodes composed of phase-locked loops (PLLs) appear as a convenient engineering solution. In this work, the stability of the synchronous state of these networks is studied in two relevant situations: when the node filters are first-order lag-lead low-pass or when the node filters are second-order low-pass. For first-order filters, the synchronous state of the network shows to be stable for any number of nodes. For second-order filter, there is a superior limit for the number of nodes, depending on the PLL parameters. Copyright (C) 2009 Atila Madureira Bueno et al.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work is part of a research under construction since 2000, in which the main objective is to measure small dynamic displacements by using L1 GPS receivers. A very sensible way to detect millimetric periodic displacements is based on the Phase Residual Method (PRM). This method is based on the frequency domain analysis of the phase residuals resulted from the L1 double difference static data processing of two satellites in almost orthogonal elevation angle. In this article, it is proposed to obtain the phase residuals directly from the raw phase observable collected in a short baseline during a limited time span, in lieu of obtaining the residual data file from regular GPS processing programs which not always allow the choice of the aimed satellites. In order to improve the ability to detect millimetric oscillations, two filtering techniques are introduced. One is auto-correlation which reduces the phase noise with random time behavior. The other is the running mean to separate low frequency from the high frequency phase sources. Two trials have been carried out to verify the proposed method and filtering techniques. One simulates a 2.5 millimeter vertical antenna displacement and the second uses the GPS data collected during a bridge load test. The results have shown a good consistency to detect millimetric oscillations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigate a recently proposed non-Markovian random walk model characterized by loss of memories of the recent past and amnestically induced persistence. We report numerical and analytical results showing the complete phase diagram, consisting of four phases, for this system: (i) classical nonpersistence, (ii) classical persistence, (iii) log-periodic nonpersistence, and (iv) log-periodic persistence driven by negative feedback. The first two phases possess continuous scale invariance symmetry, however, log-periodicity breaks this symmetry. Instead, log-periodic motion satisfies discrete scale invariance symmetry, with complex rather than real fractal dimensions. We find for log-periodic persistence evidence not only of statistical but also of geometric self-similarity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analytically calculate the time-averaged electromagnetic energy stored inside a nondispersive magnetic isotropic cylinder that is obliquely irradiated by an electromagnetic plane wave. An expression for the optical-absorption efficiency in terms of the magnetic internal coefficients is also obtained. In the low absorption limit, we derive a relation between the normalized internal energy and the optical-absorption efficiency that is not affected by the magnetism and the incidence angle. This relation, indeed, seems to be independent of the shape of the scatterer. This universal aspect of the internal energy is connected to the transport velocity and consequently to the diffusion coefficient in the multiple scattering regime. Magnetism favors high internal energy for low size parameter cylinders, which leads to a low diffusion coefficient for electromagnetic propagation in 2D random media. (C) 2010 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study determined the distribution pattern of the hermit crab Loxopagurus loxochelis by a comparison of catch, depth and environmental factors at two separate bays (Caraguatatuba and Ubatuba) of Sao Paulo State, Brazil. The influence of these parameters on the distribution of males, non- ovigerous females and ovigerous females was also evaluated. Crabs were collected monthly, over a period of one year (from July/2002 to June/2003), in seven depths, from 5 to 35 m. Abiotic factors were monitored as follows: superficial and bottom salinity (psu), superficial and bottom temperature (C), organic matter content (%) and sediment composition (%). In total, 366 hermit crabs were sampled in Caraguatatuba and 126 in Ubatuba. The highest frequency of occurrence was verified at 20 m during winter (July) in Caraguatatuba and 25 m during summer (January) in Ubatuba. The highest occurrences were recorded in the regions with bottom salinities ranging from 34 to 36 psu, bottom temperatures from 18 to 24 C and, low percentages of organic matter, gravel and mud; and large proportion of sand in the substrate. There was no significant correlation between the total frequency of organisms and the environmental factors analyzed in both regions. This evidence suggests that other variables as biotic interactions can influence the pattern of distribution of L. loxochelis in the analyzed region, which is considered the limit of the northern distribution of this species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Consider N sites randomly and uniformly distributed in a d-dimensional hypercube. A walker explores this disordered medium going to the nearest site, which has not been visited in the last mu (memory) steps. The walker trajectory is composed of a transient part and a periodic part (cycle). For one-dimensional systems, travelers can or cannot explore all available space, giving rise to a crossover between localized and extended regimes at the critical memory mu(1) = log(2) N. The deterministic rule can be softened to consider more realistic situations with the inclusion of a stochastic parameter T (temperature). In this case, the walker movement is driven by a probability density function parameterized by T and a cost function. The cost function increases as the distance between two sites and favors hops to closer sites. As the temperature increases, the walker can escape from cycles that are reminiscent of the deterministic nature and extend the exploration. Here, we report an analytical model and numerical studies of the influence of the temperature and the critical memory in the exploration of one-dimensional disordered systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Consider a random medium consisting of N points randomly distributed so that there is no correlation among the distances separating them. This is the random link model, which is the high dimensionality limit (mean-field approximation) for the Euclidean random point structure. In the random link model, at discrete time steps, a walker moves to the nearest point, which has not been visited in the last mu steps (memory), producing a deterministic partially self-avoiding walk (the tourist walk). We have analytically obtained the distribution of the number n of points explored by the walker with memory mu=2, as well as the transient and period joint distribution. This result enables us to explain the abrupt change in the exploratory behavior between the cases mu=1 (memoryless walker, driven by extreme value statistics) and mu=2 (walker with memory, driven by combinatorial statistics). In the mu=1 case, the mean newly visited points in the thermodynamic limit (N >> 1) is just < n >=e=2.72... while in the mu=2 case, the mean number < n > of visited points grows proportionally to N(1/2). Also, this result allows us to establish an equivalence between the random link model with mu=2 and random map (uncorrelated back and forth distances) with mu=0 and the abrupt change between the probabilities for null transient time and subsequent ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this manuscript is to discuss the existing barriers for the dissemination of medical guidelines, and to present strategies that facilitate the adaptation of the recommendations into clinical practice. The literature shows that it usually takes several years until new scientific evidence is adopted in current practice, even when there is obvious impact in patients' morbidity and mortality. There are some examples where more than thirty years have elapsed since the first case reports about the use of a effective therapy were published until its utilization became routine. That is the case of fibrinolysis for the treatment of acute myocardial infarction. Some of the main barriers for the implementation of new recommendations are: the lack of knowledge of a new guideline, personal resistance to changes, uncertainty about the efficacy of the proposed recommendation, fear of potential side-effects, difficulties in remembering the recommendations, inexistence of institutional policies reinforcing the recommendation and even economical restrains. In order to overcome these barriers a strategy that involves a program with multiple tools is always the best. That must include the implementation of easy-to-use algorithms, continuous medical education materials and lectures, electronic or paper alerts, tools to facilitate evaluation and prescription, and periodic audits to show results to the practitioners involved in the process. It is also fundamental that the medical societies involved with the specific medical issue support the program for its scientific and ethical soundness. The creation of multidisciplinary committees in each institution and the inclusion of opinion leaders that have pro-active and lasting attitudes are the key-points for the program's success. In this manuscript we use as an example the implementation of a guideline for venous thromboembolism prophylaxis, but the concepts described here can be easily applied to any other guideline. Therefore, these concepts could be very useful for institutions and services that aim at quality improvement of patient care. Changes in current medical practice recommended by guidelines may take some time. However, if there is a broader participation of opinion leaders and the use of several tools listed here, they surely have a greater probability of reaching the main objectives: improvement in provided medical care and patient safety.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Purpose: The right kidney has been less frequently used in live donor nephrectomy, because of the shorter length of the right renal vein (RRV) that is associated with technical difficulties and higher rates of venous thrombosis. In live open donor or deceased donor transplant nephrectomy, an additional cuff of the inferior vena cava is usually removed, but this is a more difficult and risky maneuver in laparoscopic nephrectomy. For this reason, laparoscopic right nephrectomy (LRN) for renal transplantation (RT) is not frequently performed in most medical institutions. We evaluate the difference between RRV and left renal vein (LRV) lengths in cadavers, as harvested for RT by three clamping methods. Our objective was to obtain information that could clarify when LRN for RT should be encouraged or avoided with regard to conventional surgery. Materials and Methods: Ninety adult fresh unfrozen cadavers were randomly divided into three groups of 30, according to the clamping device used: Satinsky, stapler, and Hem-o-lok clip. The abdominal viscera were removed through a median xyphopubic incision, and the veins were measured on the bench. Two lateral limits were used: The renal hilum and the tangential line of the renal poles. As for medial limits, the inferior vena cava or the laparoscopic clipping device on the RRV were used on the right side, while on the LRV, the medial border of the emergence of the adrenal vein was considered. After section of the renal vein, a slight traction of the extremity was applied for the measurement. All measurements were obtained three times using a metallic millimetric ruler, and the arithmetic mean was considered. The chi-square, one-way analysis of variance, and paired t tests were used for statistical analysis. Statistical significance was accepted at P <= 0.05. Results: The groups of cadavers were homogeneous in demographic characteristics. Regardless of the clamping method and considering the useful length of the LRV, the RRV was statistically smaller. The evaluation of the vein length did not depend on the lateral limit considered. Independent of the clamping method, on both sides, the lengths after the vein section were larger than before the section, a fact attributed to traction. Use of a stapler and a single Hem-o-lok presented the same waste of vein length on the right side. On average, the RRV was 13.7% shorter than the LRV. Conclusions: With the wide acceptance of laparoscopic live donor nephrectomy, the length difference between the veins of both kidneys is an important issue, and the right kidney is therefore used less than the left, compared with conventional surgery. This article represents the first step to quantify the anatomic length of renal veins in different situations. Certainly, more imagenologic or surgical studies should be carried out before decisions can be made for better selection of patients for LRN.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vandetanib (ZACTIMA(TM)) is a once-daily oral anticancer drug that selectively inhibits vascular endothelial growth factor receptor, epidermal growth factor receptor, and rearranged during transfection signaling. This randomized (1: 1), double-blind study evaluated vandetanib (100mg/day) or placebo in combination with docetaxel (D; 75mg/m(2) every 3 weeks) and prednisolone (P; 2 x 5 mg/day) in 86 patients with metastatic hormone-refractory prostate cancer (mHRPC). The primary assessment was prostate-specific antigen (PSA) response (confirmed reduction of >= 50% from baseline) and a greater number of patients showed a PSA response with placebo + DP (67%) versus vandetanib + DP (40%); hazard ratio = 2.23 (one-sided 80% confidence limit = 2.90; one-sided p = 0.99). More patients experienced progression events (disease progression or death from any cause) with vandetanib + DP (65%) versus placebo + DP (60%); hazard ratio = 1.13 (one-sided 80% confidence limit = 1.44; one-sided p = 0.67). The overall incidence of adverse events was similar in both groups, although more patients experienced adverse events, leading to permanent discontinuation with vandetanib + DP (28%) versus placebo + DP (12%). However, the safety and tolerability profile for vandetanib was similar to that previously reported; adverse events that occurred more frequently in the vandetanib + DP arm were hypertension (14% vs. 2%), erythematous rash (14% vs. 2%), and exfoliative rash (12% vs. 2%). In this study of patients with mHRPC, vandetanib + DP did not demonstrate any efficacy benefit, compared with placebo + DP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Hepatitis C virus (HCV) genotyping is the most significant predictor of the response to antiviral therapy. The aim of this study was to develop and evaluate a novel real-time PCR method for HCV genotyping based on the NS5B region. Methodology/Principal Findings: Two triplex reaction sets were designed, one to detect genotypes 1a, 1b and 3a; and another to detect genotypes 2a, 2b, and 2c. This approach had an overall sensitivity of 97.0%, detecting 295 of the 304 tested samples. All samples genotyped by real-time PCR had the same type that was assigned using LiPA version 1 (Line in Probe Assay). Although LiPA v. 1 was not able to subtype 68 of the 295 samples (23.0%) and rendered different subtype results from those assigned by real-time PCR for 12/295 samples (4.0%), NS5B sequencing and real-time PCR results agreed in all 146 tested cases. Analytical sensitivity of the real-time PCR assay was determined by end-point dilution of the 5000 IU/ml member of the OptiQuant HCV RNA panel. The lower limit of detection was estimated to be 125 IU/ml for genotype 3a, 250 IU/ml for genotypes 1b and 2b, and 500 IU/ml for genotype 1a. Conclusions/Significance: The total time required for performing this assay was two hours, compared to four hours required for LiPA v. 1 after PCR-amplification. Furthermore, the estimated reaction cost was nine times lower than that of available commercial methods in Brazil. Thus, we have developed an efficient, feasible, and affordable method for HCV genotype identification.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Cervical and breast cancer are the most common malignancies among women worldwide. Effective screening can facilitate early detection and dramatically reduce mortality rates. The interface between those screening patients and patients most needing screening is complex, and women in remote areas of rural counties face additional barriers that limit the effectiveness of cancer prevention programs. This study compared various methods to improve compliance with mass screening for breast and cervical cancer among women in a remote, rural region of Brazil. Methods: In 2003, a mobile unit was used to perform 10 156 mammograms and Papanicolaou smear tests for women living in the Barretos County region of Sao Paulo state, Brazil (consisting of 19 neighbouring cities). To reach the women, the following community outreach strategies were used: distribution of flyers and pamphlets; media broadcasts (via radio and car loudspeakers); and community healthcare agents (CHCAs) making home visits. Results: The most useful intervention appeared to be the home visits by healthcare agents or CHCAs. These agents of the Family Health Programme of the Brazilian Ministry of Health reached an average of 45.6% of those screened, with radio advertisements reaching a further 11.9%. The great majority of the screened women were illiterate or had elementary level schooling (80.9%) and were of 'poor' or 'very poor' socioeconomic class (67.2%). Conclusions: Use of a mobile screening unit is a useful strategy in developing countries where local health systems have inadequate facilities for cancer screening in underserved populations. A multimodal approach to community outreach strategies, especially using CHCAs and radio advertisements, can improve the uptake of mass screening in low-income, low-educational background female populations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The progression of rheumatoid arthritis (RA) is quite variable, ranging from very mild or subclinical forms (approx. 10%) to rapidly progressing and debilitating forms (10-15%). The majority of patients present with an intermediate stage with episodes of exacerbation separated by periods of relative inactivity, which evolves to progressive functional losses. To optimise the therapeutic management of early RA it is necessary to perform periodic evaluations of the clinical and laboratory test responses to the treatment instituted, as well as the parameters indicating disease prognosis. Composite measures are frequently used to evaluate the disease activity score (DAS), including the response criteria of the American College of Rheumatology (ACR), the response criteria and the DAS according to the European League Against Rheumatism (EULAR) and the composite indices of disease activity (CIDsA): DAS, the index of disease activity based on 28 joints (DAS 28), the simplified disease activity index (SDAI) and the clinical disease activity index (CDAI). The evaluation of prognosis includes investigation of the absence or occurrence of disease and joint damage remission. Due to the multifaceted nature of RA, no single clinical or laboratory parameter is able to describe satisfactorily the level of inflammatory activity or the disease prognosis at any given time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The purpose of this study was to assess the efficacy of Er:YAG laser energy for composite resin removal and the influence of pulse repetition rate on the thermal alterations occurring during laser ablation. Materials and Methods: Composite resin filling was placed in cavities (1.0 mm deep) prepared in bovine teeth and the specimens were randomly assigned to five groups according to the technique used for composite filling removal. In group I (controls), the restorations were removed using a high-speed diamond bur. In the other groups, the composite fillings were removed using an Er: YAG laser with different pulse repetition rates: group 2-2 Hz; group 3-4 Hz; group 4-6 Hz; and group 5-10 Hz. The time required for complete removal of the restorative material and the temperature changes were recorded. Results: Temperature rise during composite resin removal with the Er: YAG laser occurred in the substrate underneath the restoration and was directly proportional to the increase in pulse repetition rate. None of the groups had a temperature increase during composite filling removal of more than 5.6 degrees C, which is considered the critical point above which irreversible thermal damage to the pulp may result. Regarding the time for composite filling removal, all the laser-ablated groups (except for group 5 [10 Hz]) required more time than the control group for complete elimination of the material from the cavity walls. Conclusion: Under the tested conditions, Er: YAG laser irradiation was efficient for composite resin ablation and did not cause a temperature increase above the limit considered safe for the pulp. Among the tested pulse repetition rates, 6 Hz produced minimal temperature change compared to the control group (high-speed bur), and allowed composite filling removal within a time period that is acceptable for clinical conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The existence of a classical limit describing the interacting particles in a second-quantized theory of identical particles with bosonic symmetry is proved. This limit exists in addition to the previously established classical limit with a classical field behavior, showing that the limit h -> 0 of the theory is not unique. An analogous result is valid for a free massive scalar field: two distinct classical limits are proved to exist, describing a system of particles or a classical field. The introduction of local operators in order to represent kinematical properties of interest is shown to break the permutation symmetry under some localizability conditions, allowing the study of individual particle properties.