988 resultados para Instrumentation and orchestration.
Resumo:
The aim of this study was to develop a laboratory method for time response evaluation on electronically controlled spray equipment using Programmable Logic Controllers (PLCs). For that purpose, a PLC controlled digital drive inverter was set up to drive an asynchronous electric motor linked to a centrifugal pump on a experimental sprayer equipped with electronic flow control. The PLC was operated via RS232 serial communication from a PC computer. A user program was written to control de motor by adjusting the following system variables, all related to the motor speed: time stopped; ramp up and ramp down times, time running at a given constant speed and ramp down time to stop the motor. This set up was used in conjunction with a data acquisition system to perform laboratory tests with an electronically controlled sprayer. Time response for pressure stabilization was measured while changing the pump speed by +/-20%. The results showed that for a 0.2 s ramp time increasing the motor speed, as an example, an AgLogix Flow Control system (Midwest Technologies Inc.) took 22 s in average to readjust the pressure. When decreasing the motor speed, this time response was down to 8 s. General results also showed that this kind of methodology could make easier the definition of standards for tests on electronically controlled application equipment.
Resumo:
The interest in the systematic analysis of astronomical time series data, as well as development in astronomical instrumentation and automation over the past two decades has given rise to several questions of how to analyze and synthesize the growing amount of data. These data have led to many discoveries in the areas of modern astronomy asteroseismology, exoplanets and stellar evolution. However, treatment methods and data analysis have failed to follow the development of the instruments themselves, although much effort has been done. In present thesis, we propose new methods of data analysis and two catalogs of the variable stars that allowed the study of rotational modulation and stellar variability. Were analyzed the photometric databases fromtwo distinctmissions: CoRoT (Convection Rotation and planetary Transits) and WFCAM (Wide Field Camera). Furthermore the present work describes several methods for the analysis of photometric data besides propose and refine selection techniques of data using indices of variability. Preliminary results show that variability indices have an efficiency greater than the indices most often used in the literature. An efficient selection of variable stars is essential to improve the efficiency of all subsequent steps. Fromthese analyses were obtained two catalogs; first, fromtheWFCAMdatabase we achieve a catalog with 319 variable stars observed in the photometric bands Y ZJHK. These stars show periods ranging between ∼ 0, 2 to ∼ 560 days whose the variability signatures present RR-Lyrae, Cepheids , LPVs, cataclysmic variables, among many others. Second, from the CoRoT database we selected 4, 206 stars with typical signatures of rotationalmodulation, using a supervised process. These stars show periods ranging between ∼ 0, 33 to ∼ 92 days, amplitude variability between ∼ 0, 001 to ∼ 0, 5 mag, color index (J - H) between ∼ 0, 0 to ∼ 1, 4 mag and spectral type CoRoT FGKM. The WFCAM variable stars catalog is being used to compose a database of light curves to be used as template in an automatic classifier for variable stars observed by the project VVV (Visible and Infrared Survey Telescope for Astronomy) moreover it are a fundamental start point to study different scientific cases. For example, a set of 12 young stars who are in a star formation region and the study of RR Lyrae-whose properties are not well established in the infrared. Based on CoRoT results we were able to show, for the first time, the rotational modulation evolution for an wide homogeneous sample of field stars. The results are inagreement with those expected by the stellar evolution theory. Furthermore, we identified 4 solar-type stars ( with color indices, spectral type, luminosity class and rotation period close to the Sun) besides 400 M-giant stars that we have a special interest to forthcoming studies. From the solar-type stars we can describe the future and past of the Sun while properties of M-stars are not well known. Our results allow concluded that there is a high dependence of the color-period diagram with the reddening in which increase the uncertainties of the age-period realized by previous works using CoRoT data. This thesis provides a large data-set for different scientific works, such as; magnetic activity, cataclysmic variables, brown dwarfs, RR-Lyrae, solar analogous, giant stars, among others. For instance, these data will allow us to study the relationship of magnetic activitywith stellar evolution. Besides these aspects, this thesis presents an improved classification for a significant number of stars in the CoRoT database and introduces a new set of tools that can be used to improve the entire process of the photometric databases analysis
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Condition monitoring is used to increase machinery availability and machinery performance, reducing consequential damage, increasing machine life, reducing spare parts inventories, and reducing breakdown maintenance. An efficient real time vibration measurement and analysis instruments is capable of providing warning and predicting faults at early stages. In this paper, a new methodology for the implementation of vibration measurement and analysis instruments in real time based on circuit architecture mapped from a MATLAB/Simulink model is presented. In this study, signal processing applications such as FIR filters and fast Fourier transform are treated as systems, which are implemented in hardware using a system generator toolbox, which translates a Simulink model in a hardware description language - HDL for FPGA implementations.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The monitoring of Earth dam makes use of visual inspection and instrumentation to identify and characterize the deterioration that compromises the security of earth dams and associated structures. The visual inspection is subjective and can lead to misinterpretation or omission of important information and, some problems are detected too late. The instrumentation are efficient but certain technical or operational issues can cause restrictions. Thereby, visual inspections and instrumentation can lead to a lack of information. Geophysics offers consolidated, low-cost methods that are non-invasive, non-destructive and low cost. They have a strong potential and can be used assisting instrumentation. In the case that a visual inspection and strumentation does not provide all the necessary information, geophysical methods would provide more complete and relevant information. In order to test these theories, geophysical acquisitions were performed using Georadar (GPR), Electric resistivity, Seismic refraction, and Refraction Microtremor (ReMi) on the dike of the dam in Sant Llorenç de Montgai, located in the province of Lleida, 145 km from Barcelona, Catalonia. The results confirmed that the geophysical methods used each responded satisfactorily to the conditions of the earth dike, the anomalies present and the geological features found, such as alluvium and carbonate and evaporite rocks. It has also been confirmed that these methods, when used in an integrated manner, are able to reduce the ambiguities in individual interpretations. They facilitate improved imaging of the interior dikes and of major geological features, thus inspecting the massif and its foundation. Consequently, the results obtained in this study demonstrated that these geophysical methods are sufficiently effective for inspecting earth dams and they are an important tool in the instrumentation and visual inspection of the security of the dams
Resumo:
Furcation involvement in periodontal disease has been a challenge for the dentist. Objective: The aim of this study was to investigate root dimensions in the furcation area of 233 mandibular first molars. Material and Methods: Digital photomicrographs were used to obtain the following measurements on the buccal and lingual surfaces of each tooth: root trunk height (RT), horizontal interadicular distance obtained 1 mm (D1) and 2 mm (D2) below the fornix and interadicular angle (IA). Results: Mean standard deviation of buccal and lingual furcation measurements were, respectively, 1.37 +/- 0.78 mm and 2.04 +/- 0.89 mm for RT; 0.86 +/- 0.39 mm and 0.71 +/- 0.42 mm for D1; 1.50 +/- 0.48 mm and 1.38 +/- 0.48 mm for D2; 41.68 +/- 13.20 degrees and 37.78 +/- 13.18 degrees for IA. Statistically significant differences were found between all measured parameters for buccal and lingual sides (p<0.05, paired t test). Conclusions: In conclusion, the lingual furcation of mandibular first molars presented narrower entrance and longer root trunk than the buccal furcation, suggesting more limitation for instrumentation and worse prognosis to lingual furcation involvements in comparison to buccal lesions.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The present study was designed to investigate the effectiveness of different ultrasonic instruments on the root surface. Fourteen patients with 35 single root teeth designated for extraction were recruited to the present study. Teeth were assigned to four experimental groups: group 1, piezoelectric ultrasonic device; group 2, magnetostrictive ultrasonic device; group 3, hand instrumentation; and group 4, untreated teeth (control). After instrumentation, the teeth were extracted and the presence of residual deposits (roughness and root surfaces characteristics) were analyzed. The results showed that residual deposits were similar in all tested groups: piezoelectric, 8.7%; magnetostrictive, 9.7%; hand instrumentation, 11.1% and control, 76.4%. There were statistically significant differences between control and all the experimental groups (p < 0.0001). With respect to roughness parameters evaluation, R(a) and R(z) of the roots treated with the different instruments showed a similar pattern (p > 0.05), but for R(t) and R(y), a significant difference was observed (p < 0.05) among hand instrumentation and ultrasonic devices. SEM analysis revealed a similar root surface pattern for the ultrasonic devices, but curettes showed many instrumental scratches, deep gouges, and a relatively large amount of dentin was removed. Within the limits of the study, although the instruments produced similar results, root surfaces instrumentated with curettes were rougher and had more root surface tissue removed than with the ultrasonic device.
Resumo:
A presença de umidade no interior do sistema de canais radiculares, após o preparo biomecânico e sua desinfecção, pode influenciar no selamento apical e no êxito da obturação endodôntica. O objetivo deste trabalho foi avaliar a influência do número de esterilizações em autoclave, sobre a capacidade e velocidade de absorção dos cones de papel empregados em Endodontia. Foram analisados 440 cones de papel número 40, dos quais dez cones de cada marca comercial receberam de zero à dez ciclos de esterilização em autoclave (134°C/15 psi/15 minutos). Após cada ciclo de esterilização, os cones foram avaliados quanto a capacidade e velocidade de absorção de solução de hipoclorito de sódio a 1%. Os dados foram submetidos à análise estatística por meio dos testes da ANOVA (dois critérios) e Tukey (5%). Pôde-se concluir que, quanto à capacidade de absorção, os cones que sofreram menor influência dos diversos ciclos de esterilização em autoclave foram, em ordem decrescente: Tanari, Tanari cell pack, Conne e Diadent cell pack. Quanto à velocidade de absorção, os cones que obtiveram os melhores resultados foram: Tanari cell pack, Tanari, Conne e Diadent cell pack. A autoclavação mostrou-se um procedimento viável, em até 10 ciclos, apenas para a esterilização de cones de papel absorvente da marca Tanari utilizados em Endodontia.
Resumo:
This paper presents two methods to measure magnetic losses in an iron core for didactic applications for undergraduate students. It is based on indirect measurements of magnetic field and induced flux, simplifying the required instrumentation, and thus, making its implementation possible for lab sessions. Moreover, a comparison between two methods is proposed, allowing the students reaching a deeper understanding of the hysteresis phenomena.
Resumo:
Droplets formed at the tip of a tube under the same conditions possess extreme uniformity of form, volume and weight. These properties of liquid drop formation have been known for a long time and consequently many applications for the drop have been found in instrumentation and chemical analysis methods. In the present paper, we report on the analytical use of a dynamic LED-based flow-through optical absorption detector with optical path length controlled by continuous dropping of a solution. This arrangement consists of a flow cell built within a high-intensity red LED (lambda (max)=630 nm). The feasibility of the detector is demonstrated by colorimetric determination of methylene blue, and ammonium by Berthelot's reaction, in a flow-injection system. For ammonium, the reaction forms a blue dye (indophenol) with a maximum absorption at 630-650 nm. The detection limit, considered as 3 times the signal of the blank, is better than 125 mu g l(-1). The small flow cell represents a good combination of optical path length, low volume and fast washout. This detector can be used advantageously in automated methods and can represent a solution to problems of optical detection involving gas bubbles and precipitation of particles in turbidimetric applications.
Resumo:
This paper describes a strain gauge-based sensor used for measuring finger force. The theory, design, and sensor construction details are presented. It was constructed using metallic strain gauges and a carefully designed structure which has a protection de-vice that impedes the sensor damage when forces higher than 100 N are applied. Its dimensions are suitable for measuring thumb force, but the same design can be used for constructing smaller sensors for other fingers. It is rugged, presents linear response, good repeatability, resolution of 0.3 N, low hysteresis, and sensitivity of 0.12 V/N. It can be useful in rehabilitation engineering, biomechanics, robotics, and medicine.
Resumo:
This paper presents the instantaneous-space-phasor (ISP) definition and describes its properties and possible applications for three-phase systems. It is shown that the ISP provides the mathematical base for a new approach to the measurement of active, reactive, and apparent power. Moreover, the ISP helps separate the positive and negative-sequence components and fits perfectly into the Buchholz-Goodhue apparent power definition.
Resumo:
An ultrasonic density-measurement cell is experimentally characterized as a function of temperature. The measurement of propagation velocity and density of several liquids is performed in the 15 degrees C-40 degrees C temperature range. Results are compared to the tabulated values in the case of distilled water, showing an accuracy of 0.07% for the propagation velocity. The cell was tested with distilled water, alcohol, and homogenized milk, and density values are compared to those obtained with a pycnometer, showing 0.2% accuracy in density measurement for stabilized temperature and 0.4% accuracy under thermal gradient conditions.