930 resultados para Indoor geolocation
Resumo:
A number of indoor environmental factors, including bioaerosol or aeroallergen concentrations have been identified as exacerbators for asthma and allergenic conditions of the respiratory system. People generally spend 90% to 95% of their time indoors. Therefore, understanding the environmental factors that affect the presence of aeroallergens indoors as well as outdoors is important in determining their health impact, and in identifying potential intervention methods. This study aimed to assess the relationship between indoor airborne fungal spore concentrations and indoor surface mold levels, indoor versus outdoor airborne fungal spore concentrations and the effect of previous as well as current water intrusion. Also, the association between airborne concentration of indoor fungal spores and surface mold levels and the age of the housing structure were examined. Further, the correlation between indoor concentrations of certain species was determined as well. ^ Air and surface fungal measurements and related information were obtained from a Houston-area data set compiled from visits to homes filing insurance claims. During the sampling visit these complaint homes exhibited either visible mold or a combination of visible mold and water intrusion problems. These data were examined to assess the relationships between the independent and dependent variables using simple linear regression analysis, and independent t-tests. To examine the correlation between indoor concentrations of certain species, Spearman correlation coefficients were used. ^ There were 126 houses sampled, with spring, n=43 (34.1%), and winter, n=42 (33.3%), representing the seasons with the most samples. The summer sample illustrated the highest geometric mean concentration of fungal spores, GM=5,816.5 relative to winter, fall and spring (GM=1,743.4, GM=3,683.5 and GM=2,507.4, respectively). In all seasons, greater concentrations of fungal spores were observed during the cloudy weather conditions. ^ The results indicated no statistically significant association between outdoor total airborne fungal spore concentration and total living room airborne fungal spore concentration (β = 0.095, p = 0.491). Second, living room surface mold levels were not associated with living room airborne fungal spore concentration, (β= 0.011, p = 0.669). Third, houses with and without previous water intrusion did not differ significantly with respect to either living room (t(111) = 0.710, p = 0.528) or bedroom (t(111) =1.673, p = 0.162) airborne fungal spore concentrations. Likewise houses with and without current water intrusion did not differ significantly with respect to living room (t(109)=0.716, p = 0.476) or bedroom (t(109) = 1.035, p = 0.304) airborne fungal spore concentration. Fourth, houses with and without current water intrusion did not differ significantly with respect to living room (χ 2 (5) = 5.61, p = 0.346), or bedroom (χ 2 (5) = 1.80, p = 0.875) surface mold levels. Fifth, the age of the house structure did not predict living room (β = 0.023, p = 0.102) and bedroom (β = 0.023, p = 0.065) surface mold levels nor living room (β = 0.002, p = 0.131) and bedroom (β = 0.001, p = 0.650) fungal spore airborne concentration. Sixth, in houses with visually observed mold growth there was statistically significant differences between the mean living room concentrations and mean outdoor concentrations for Cladosporium (t (107) = 11.73, p < 0.0001), Stachybotrys (t (106)=2.288, p = 0.024, and Nigrosporia (t (102) = 2.267, p = 0.025). Finally, there was a significant correlation between several living room fungal species pairs, namely, Cladosporium and Stachybotrys (r = 0.373, p <0.01, n=65), Curvularia and Aspergillus/Penicillium (r = 0.205, p < 0.05, n= 111)), Curvularia and Stachybotrys (r = 0.205, p < 0.05, n=111), Nigrospora and Chaetomium (r = 0.254, p < 0.01, n=105) and Stachybotrys and Nigrospora (r = 0.269, p < 0.01, n=105). ^ This study has demonstrated several positive findings, i.e., significant pairwise correlations of concentrations of several fungal species in living room air, and significant differences between indoor and outdoor concentrations of three fungal species in homes with visible mold. No association was observed between indoor and outdoor fungal spore concentrations. Neither living room nor bedroom airborne spore concentrations and surface mold levels were related to the age of the house or to water intrusion, either previous or current. Therefore, these findings suggest the need for evaluating additional parameters, as well as combinations of factors such as humidity, temperature, age of structure, ventilation, and room size to better understand the determinants of airborne fungal spore concentrations and surface mold levels in homes. ^
Resumo:
This MPH thesis consists of (1) literature review of the relatively new synthetic persistent organic pollutants (POP), polybrominated diphenyl ethers (PBDEs), a type of flame retardant posing a potential public health hazard, (2) Presentation of data on PBDE levels in dryer lint from Dallas, TX and Hamburg, Germany. ^ PBDEs are used as additive fire retardants in plastics, polyurethane foam and electronic equipment to reduce flammability and thus save life and property. PBDEs have been widely used beginning in the 1970s. They resemble polychlorinated biphenyls (PCBs) in structure and toxicity. PBDEs are found in environmental sediments, sludges, and wildlife and even in human blood, milk and tissues. ^ PBDEs, due to their lipophilicity, accumulate in fat and other tissues and biomagnify up the food chain, with increasing concentrations. Animal studies have suggested potential health effects including thyroid disruption, permanent learning and memory impairment, fetal malformations, developmental neurotoxicity and, at high doses, possibly cancer. ^ PBDE levels are increasing in blood and breast milk in North America, but PBDEs intake unlike PCBs appears to be not primarily through food; food PBDE levels in the U.S. are not markedly higher than in Europe yet U.S. human blood and milk levels are much higher. For this reason various exposure pathways including PBDE contaminated dust and air have been studied to better characterize routes of PBDE intake into humans. ^ The scientific literature on PBDE levels in household dust reports higher PBDE concentration in dust than that found in dryer lint; levels in the U.S are elevated compared to other countries with congeners such as BDE 47, 99, 100 and 209 predominating. The United Kingdom has elevated BDE 209 due to high usage of Deca commercial mixture. These studies suggest that indoor PBDE contamination through household dust could be a potential source of PBDE exposure and body burden especially in young children. ^ PBDE levels in dryer lint from U.S ranged from 321 to 3073 ng/g (Mean: 1138 ng/g, Median: 803 ng/g) and from Germany were from 330 to 2069 ng/g (Median: 71ng/g, Mean: 361 ng/g). High median levels in U.S samples indicate contamination of lint with PBDEs although the source of the PBDEs in lint may be from dryer electrical components or air deposition onto clothes, lint may be one source of PBDE exposure to humans. ^
Resumo:
Research studies on the association between exposures to air contaminants and disease frequently use worn dosimeters to measure the concentration of the contaminant of interest. But investigation of exposure determinants requires additional knowledge beyond concentration, i.e., knowledge about personal activity such as whether the exposure occurred in a building or outdoors. Current studies frequently depend upon manual activity logging to record location. This study's purpose was to evaluate the use of a worn data logger recording three environmental parameters—temperature, humidity, and light intensity—as well as time of day, to determine indoor or outdoor location, with an ultimate aim of eliminating the need to manually log location or at least providing a method to verify such logs. For this study, data collection was limited to a single geographical area (Houston, Texas metropolitan area) during a single season (winter) using a HOBO H8 four-channel data logger. Data for development of a Location Model were collected using the logger for deliberate sampling of programmed activities in outdoor, building, and vehicle locations at various times of day. The Model was developed by analyzing the distributions of environmental parameters by location and time to establish a prioritized set of cut points for assessing locations. The final Model consisted of four "processors" that varied these priorities and cut points. Data to evaluate the Model were collected by wearing the logger during "typical days" while maintaining a location log. The Model was tested by feeding the typical day data into each processor and generating assessed locations for each record. These assessed locations were then compared with true locations recorded in the manual log to determine accurate versus erroneous assessments. The utility of each processor was evaluated by calculating overall error rates across all times of day, and calculating individual error rates by time of day. Unfortunately, the error rates were large, such that there would be no benefit in using the Model. Another analysis in which assessed locations were classified as either indoor (including both building and vehicle) or outdoor yielded slightly lower error rates that still precluded any benefit of the Model's use.^
Resumo:
Background. First synthesized in 1874, dichlorodiphenyltrichloroethane (DDT) was not used until the second half of World War II after its insecticidal properties were discovered in 1939. For decades DDT has been used globally with the intent of eradicating malaria. This began in 1955 when the eighth World Health Assembly launched a global campaign selecting DDT as the chemical of choice for the eradication of malaria. The United States banned DDT use in 1972 partially due to the publication of “Silent Spring” by Rachel Carson in 1962 which suggested that DDT was harmful to the environment, wildlife and is a carcinogen. ^ Objectives. To critically review the literature on DDT, and evaluate its importance in malaria prevention and control. Methods: The design of this systematic literature review is a narrative summary and evaluation of the papers reviewed. The data came from searches using PubMed and MEDLINE which are free and publicly available databases. Inclusive criteria that were considered during the search are English language peer reviewed journal articles published in the last 20 years. The keywords were: “insecticidal and agricultural use of DDT”, “human impact of malaria”, “economic impact of malaria”, “benefits of DDT”, “effects of DDT”, “importance of malaria control”, and alternatives to DDT for malaria control. ^ Results. Malaria continues to be one of the most common infectious diseases and creates a tremendous global public health problem. WHO recommends DDT for malaria vector control because compared to other pesticides, it is the most persistent in indoor spraying. ^ Conclusion. Indoor spraying of DDT in malaria endemic areas may cause increased exposure of the chemical to humans; however I conclude that the overall benefits outweigh the risks because more lives are saved due to fewer infections with malaria.^
Resumo:
The cross-sectional study was performed to quantify the prevalence of symtomatology in residents of mobile homes as a function of indoor formaldehyde concentration. Formaldehyde concentrations were monitored for a seven hour period with an automated wet-chemical colorimetric analyzer. The health status of family members was ascertained by administration of questionnaires and physical exams. This is the first investigation to perform clinical assessments on residents undergoing concurrent exposure assessment in the home.^ Only 22.8% of households eligible for participation chose to cooperate. Monitoring data and health evaluations were obtained from 155 households in four Texas counties. A total of 428 residents (86.1%) were available for examination during the sampling hours. The study population included 45 infants, 126 children, and 257 adults.^ Formaldehyde concentration was not found to be significantly associated with increased risks for symptoms and signs of ocular irritation, dermal anomalies, or malaise. Three associations were identified that warrant further investigation. The relative odds associated with a doubling of formaldehyde concentration was significantly associated with parenchymal rales in adults and children. However, risk was modified by log respirable suspended particulate concentrations. Due to the presence of modification by a continuous variable, prevalence odds ratios (POR) and 95% confidence intervals (95% CI) for these associations are presented in tables. A doubling of formaldehyde concentration was also associated with an increased risk of perceived tightness in the chest in adults. Prevalence odds ratios are presented in a table due to effect modification by the average number of hours spent indoors on weekdays. Furthermore, a doubling of formaldehyde concentration was associated with an increased risk of drowsiness in children (POR = 2.60; 95% CI 1.04-6.51) and adults (POR = 1.94; 95% CI 1.20-3.14). ^
Resumo:
Diarrheal disease associated with enterotoxigenic Escherichia coli (ETEC) infection is one of the major public health problems in many developing countries, especially in infants and young children. Because tests suitable for field laboratories have been developed only relatively recently, the literature on the environmental risk factors associated with ETEC is not as complete as for many other pathogens or for diarrhea of unspecified etiology.^ Data from a diarrheal disease surveillance project in rural Egypt in which stool samples were tested for a variety of pathogens, and in which an environmental questionnaire was completed for the same study households, provided an opportunity to test for an association between ETEC and various risk factors present in those households. ETEC laboratory-positive specimens were compared with ETEC laboratory-negative specimens for both symptomatic and asymptomatic children less than three years of age at the individual and household level using a case-comparison design.^ Individual children more likely to have LT infection were those who lived in HHs that had cooked food stored for subsequent consumption at the time of the visit, where caretakers used water but not soap to clean an infant after a diarrheal stool, and that had an indoor, private water source. LT was more common in HHs where the caretaker did not clean an infant with soap after a diarrheal stool, and where a sleeping infant was not covered with a net. At both the individual and HH level, LT was significantly associated with good water supply in terms of quantity and storage.^ ST was isolated more frequently at the individual level where a sleeping infant was covered with a net, where large animals were kept in or around the house, where water was always available and was not potable, and where the water container was not covered. At the HH level, the absence of a toilet or latrine and the indiscriminate disposal of animal waste decreased risk. Using animal feces for fertilizer, the presence of large animals, and poor water quality were associated with ST at both the individual and HH level.^ These findings are mostly consistent with those of other studies, and/or are biologically plausible, with the obvious exception of those from this study where poorer water supplies are associated with less infection, at least in the case of LT. More direct observation of how animal ownership and feces disposal relates to different types of water supply and usage might clarify mechanisms through which some ETEC infection could be prevented in similar settings. ^
Resumo:
Species variations in formaldehyde solutions and gases were investigated by means of infrared spectral analysis. Double beam infrared spectrometry in conjunction with sodium chloride wafer technique and solvent compensation technique were employed. Formaldehyde species in various solutions were investigated. Formalin 37% was stable for many months. Refrigeration had no effects on its stability. Spectral changes were detected in 1000 ppm formaldehyde solutions. The absorbances of very diluted solutions up to 100 ppm were lower than the detection limit of the instruments. Solvent compensation improved resolution, but was associated with an observed lack of repeatability. Formaldehyde species in animal chambers containing animals and in mobile home air were analyzed with the infrared spectrophotometer equipped with a 10 cm gas cell. Spectra were not different from the spectrum of clean air. A portable single beam infrared spectrometer with a 20 meter pathlength was used for reinvestigation. Indoor formaldehyde could not be detected in the spectral; conversely, an absorption peak at 3.58 microns was found in the spectra of 3 and 15 ppm formaldehyde gas in animal chambers. This peak did not appear in the spectrum of the control chamber. Because of concerns over measurement bias among various analytical methods for formaldehyde, side-by-side comparisons were conducted in both laboratory and field measurements. The chromotropic acid method with water and 1% sodium bisulfite as collection media, the pararosaniline method, and a single beam infrared spectrometer were compared. Measurement bias was elucidated and the extent of the effects of temperature and humidity was also determined. The problems associated with related methods were discussed. ^
Resumo:
Environmental tobacco smoke (ETS) is an important indoor air pollutant associated with adverse effects on the respiratory health of the general population, especially people with asthma. ETS consists mainly of sidestream smoke from burning cigarettes and a smaller quantity of mainstream smoke which is exhaled by the smoker. At least one out of every three children is frequently exposed to ETS. ^ This paper reviewed the literature for studies on the role of ETS in the development and exacerbation of asthma among children in developing countries, specifically the low and middle income countries from the year 1980 to the present. The databases searched in this systematic review were: Ovid Medline; PubMed (National Library of Medicine); and Cumulative Index to Nursing and Allied Health (CINAHL) (EBSCOhost). Out of a total of 197 articles initially identified, only four studies (two from China, one from Macedonia and one from Brazil) were rated by two independent raters as being of high quality, and were selected for final abstraction, synthesis and evidence weighting. Results from these four studies suggests that, in developing countries, ETS exposure is associated with childhood asthma, and that asthma prevalence increases with an increase in the amount and duration of exposure to ETS. Similarly, exposure to ETS is associated with persistent cough, current night dry cough, and exacerbation of asthma symptoms. ^ Therefore, as is the case in developed nations, there is suggestive evidence in the literature that ETS exposure plays substantial role in the development and/or exacerbation of asthma among children in developing countries. To decrease the likelihood of new asthma development, enhance asthma control, and reduce the rate of medical service utilization in children exposed to ETS, smoking should be eliminated at home and in public places.^
Resumo:
Background. It is estimated that hospitals spend between 28 and 33 billion dollars per year as a result of hospital-acquired infections. (Scott, 2009) The costs continue to rise despite the guidance and controls provided by hospital infection control staff to reduce patient exposures to fungal spores and other infectious agents. With all processes and controls in place, the vented elevator shaft represents an unprotected opening from the top of the building to the lower floors. The hypothesis for this prospective study is that there is a positive correlation between the number of Penicillium/Aspergillus-like spores, Cladosporium, ascospores, basidiospores in spores/m3 as individual spore categories found in the hoistway vent of an elevator shaft and the levels of the same spores, sampled near-simultaneously in the outdoor intake of the elevator shaft. Specific aims of this study include determining if external Penicillium/Aspergillus-like spores are entering the healthcare facility via the elevator shaft and hoistway vents. Additional aims include determining levels of Penicillium/Aspergillus-like spores outdoors, in the elevator shafts, and indoors in areas possibly affected by elevator shaft air; and, finally, to evaluate whether any effect is observed due to the installation of a hoistway vent damper, installed serendipitously during this study. ^ Methods. Between April 2010 and September 2010, a total of 3,521 air samples were collected, including 363 spore trap samples analyzed microscopically for seven spore types, and polymerase chain reaction analyses on 254 air samples. 2178 particle count measurements, 363 temperature readings and 363 relative humidity readings were also obtained from 7 different locations potentially related to the path of air travel inside and near a centrally-located and representative elevator shaft. ^ Results. Mean Penicillium/Aspergillus-like spore values were higher outside the building (530 spores/m3 of air) than inside the hoistway (22.8 spores/m3) during the six month study. Mean values inside the hospital were lower than outside throughout the study, ranging from 15 to 73 spores/m3 of air. Mean Penicillium/Aspergillus-like spore counts inside the hoistway decreased from 40.1 spores/m3 of air to 9 spores/m3 of air following the installation of a back draft damper between the outside air and the elevator shaft. Comparison of samples collected outside the building and inside the hoistway vent prior to installing the damper indicated a strong positive correlation (Spearman's Rho=0.8008, p=0.0001). The similar comparison following the damper installation indicated a moderate non-significant inverse correlation (Spearman's rho = −0.2795, p=0.1347). ^ Conclusion. Elevator shafts are one pathway for mold spores to enter a healthcare facility. A significant correlation was detected between spores and particle counts inside the hoistway and outside prior to changes in the ventilation system. The insertion of the back draft damper appeared to lower the spore counts inside the hoistway and inside the building. The mold spore counts in air outside the study building were higher in the period following the damper installation while the levels inside the hoistway and hospital decreased. Cladosporium and Penicillium/Aspergillus -like spores provided a method for evaluating indoor air quality as a natural tracer from outside the building to inside the building. Ascospores and basidiospores were not a valuable tracer due to low levels of detection during this study. ^ Installation of a back draft damper provides additional protection for the indoor environment of a hospital or healthcare facility, including in particular patients who may be immunocompromised. Current design standards and references do not require the installation of a back draft damper, but evaluation of adding language to relevant building codes should be considered. The data indicate a reduction in levels of Penicillium/Aspergillus -like spores, particle counts and a reduction in relative humidity inside of the elevator shaft after damper installation.^
Resumo:
An exposure system was constructed to evaluate the performance of a personal organic vapor dosimeter (3520 OVM) at ppb concentrations of nine selected target volatile organic compounds (VOCs). These concentration levels are generally encountered in community air environments, both indoor and outdoor. It was demonstrated that the chamber system could provide closely-controlled conditions of VOC concentrations, temperature and relative humidity (RH) required for the experiments. The target experimental conditions included combinations of three VOC concentrations (10, 20 and 200 $\rm\mu g/m\sp3),$ three temperatures (10, 25 and 40$\sp\circ$C) and three RHs (12, 50 and 90% RH), leading to a total of 27 exposure conditions. No backgrounds of target VOCs were found in the exposure chamber system. In the exposure chamber, the variation of the temperature was controlled within $\pm$1$\sp\circ$C, and the variation of RH was controlled within $\pm$1.5% at 12% RH, $\pm$2% at 50% RH and $\pm$3% at 90% RH. High-emission permeation tubes were utilized to generate the target VOCs. Various patterns of the permeation rates were observed over time. The lifetimes and permeation rates of the tubes differed by compound, length of the tube and manufacturer. By carefully selecting the source and length of the tubes, and closely monitoring tube weight loss over time, the permeation tubes can be used for delivering low and stable concentrations of VOCs during multiple days.^ The results of this study indicate that the performance of the 3520 OVM is compound-specific and depends on concentration, temperature and humidity. With the exception of 1,3-butadiene under most conditions, and styrene and methylene chloride at very high relative humidities, recoveries were generally within $\pm$25% of theory, indicating that the 3520 OVM can be effectively used over the range of concentrations and environmental conditions tested with a 24-hour sampling period. Increasing humidities resulted in increasing negative bias from full recovery. Reverse diffusion conducted at 200 $\rm\mu g/m\sp3$ and five temperature/humidity combinations indicated severe diffusion losses only for 1,3-butadiene, methylene chloride and styrene under increased humidity. Overall, the results of this study do not support the need to employ diffusion samplers with backup sections for the exposure conditions tested. ^
Resumo:
This cross-sectional analysis of the data from the Third National Health and Nutrition Examination Survey was conducted to determine the prevalence and determinants of asthma and wheezing among US adults, and to identify the occupations and industries at high risk of developing work-related asthma and work-related wheezing. Separate logistic models were developed for physician-diagnosed asthma (MD asthma), wheezing in the previous 12 months (wheezing), work-related asthma and work-related wheezing. Major risk factors including demographic, socioeconomic, indoor air quality, allergy, and other characteristics were analyzed. The prevalence of lifetime MD asthma was 7.7% and the prevalence of wheezing was 17.2%. Mexican-Americans exhibited the lowest prevalence of MD asthma (4.8%; 95% confidence interval (CI): 4.2, 5.4) when compared to other race-ethnic groups. The prevalence of MD asthma or wheezing did not vary by gender. Multiple logistic regression analysis showed that Mexican-Americans were less likely to develop MD asthma (adjusted odds ratio (ORa) = 0.64, 95%CI: 0.45, 0.90) and wheezing (ORa = 0.55, 95%CI: 0.44, 0.69) when compared to non-Hispanic whites. Low education level, current and past smoking status, pet ownership, lifetime diagnosis of physician-diagnosed hay fever and obesity were all significantly associated with MD asthma and wheezing. No significant effect of indoor air pollutants on asthma and wheezing was observed in this study. The prevalence of work-related asthma was 3.70% (95%CI: 2.88, 4.52) and the prevalence of work-related wheezing was 11.46% (95%CI: 9.87, 13.05). The major occupations identified at risk of developing work-related asthma and wheezing were cleaners; farm and agriculture related occupations; entertainment related occupations; protective service occupations; construction; mechanics and repairers; textile; fabricators and assemblers; other transportation and material moving occupations; freight, stock and material movers; motor vehicle operators; and equipment cleaners. The population attributable risk for work-related asthma and wheeze were 26% and 27% respectively. The major industries identified at risk of work-related asthma and wheeze include entertainment related industry; agriculture, forestry and fishing; construction; electrical machinery; repair services; and lodging places. The population attributable risk for work-related asthma was 36.5% and work-related wheezing was 28.5% for industries. Asthma remains an important public health issue in the US and in the other regions of the world. ^
Resumo:
En el presente trabajo se muestran los resultados experimentales obtenidos del cultivo del consorcio de microalgas (Chlorella sp y Scenedesmus sp.) empleando el efluente urbano pretratado proveniente de la planta de tratamiento cloacal ―La Viñita‖, Provincia de Catamarca, Argentina. Los objetivos se orientan a caracterizar el consorcio de microalgas autóctonas en cuanto a la relación de la producción de biomasa y lípidos, en condiciones controladas de cultivo, en efluentes urbanos provenientes de la planta de tratamiento de líquidos cloacales ―La Viñita‖ y analizar la eficiencia del proceso biorremediador realizado por las microalgas, considerando la eficiencia de los tratamientos, en relación a los parámetros que corresponden a días de cultivo, estado del consorcio y propiedades físico-químicas del sobrenadante. Se emplearon tres variables (% de Inóculo, % de medio nutricional e inyección de CO2), el ensayo se realizó a lo largo de 12 días de cultivo ―indoor‖. Se analizaron los datos de producción de biomasa en cada tratamiento, se determinó la concentración de lípidos presentes en la biomasa y se hizo observación microscópica de los distintos tratamientos al finalizar el ensayo y un seguimiento macroscópico durante el ensayo. Se eligieron los tratamientos eficientes en términos de biomasa y lípidos. En todos los casos se empleó fotoperiodo 12 hs/12 hs, sin control de esterilidad y con agitación manual. Sobre cada muestra se realizaron las determinaciones de biomasa, lípidos y pH. Considerando los aspectos de desarrollo de las microalgas y los parámetros físico-químicos, los resultados obtenidos indicaron que los tratamientos con inyección de CO2 alcanzaron mayor productividad de biomasa algal y lípidos. En las condiciones de 20% de inóculo, inyección de CO2, empleo de efluente con refuerzo de medio nutricional se obtiene en 3 días: 58 mg/L de biomasa y la producción más alta del ensayo en cuanto a lípidos (16,8 mg/L). En cuanto al proceso biorremediador se observó que disminuyó la concentración de DBO5 en un 63,63 %, la de DQO en un 51,8 %, la de nitratos en un 38 % y aumentó la cantidad de fosfato, lo que podrá ser corregido con modificaciones en las concentraciones de sales en el medio de cultivo. El efluente resultante no presenta riesgo de sodicidad por lo que podría ser utilizada para riego. Se observó un cambio de color (de verde claro a verde oscuro) y se confirmó con la observación microscópica la predominancia de Chlorella sp. en un 90 %, la presencia de rotíferos en baja cantidad y ausencia de otras microlagas no deseadas como filamentosas y diatomeas. No se detectó la presencia de huevo de helmintos.
Resumo:
El objetivo de este artículo es caracterizar las formas de inserción laboral de mujeres, que aparecen como mano de obra transitoria, en el mercado de trabajo frutihortícola marplatense. El trabajo femenino asalariado está presente en la actividad hortícola que se practica a campo y bajo cubierta y en cultivos frutícolas no tradicionales. La investigación nos ha permitido indagar cómo y por qué estas mujeres se insertan en la actividad agrícola, identificar los procesos laborales específicos que requieren su fuerza de trabajo, así como las modalidades de remuneración y la complementación con otras actividades económicas. La perspectiva de género en el análisis de la participación laboral pone en juego múltiples dimensiones de las relaciones laborales. Desde este enfoque, se procura examinar la participación de las mujeres en las actividades remuneradas, explorando algunos de los rasgos que la configuran
Resumo:
This study is a first effort to compile the largest possible body of data available from different plankton databases as well as from individual published or unpublished datasets regarding diatom distribution in the world ocean. The data obtained originate from time series studies as well as spatial studies. This effort is supported by the Marine Ecosystem Data (MAREDAT) project, which aims at building consistent data sets for the main PFTs (Plankton Functional Types) in order to help validate biogeochemical ocean models by using converted C biomass from abundance data. Diatom abundance data were obtained from various research programs with the associated geolocation and date of collection, as well as with a taxonomic information ranging from group down to species. Minimum, maximum and average cell size information were mined from the literature for each taxonomic entry, and all abundance data were subsequently converted to biovolume and C biomass using the same methodology.
Resumo:
El objetivo de este artículo es caracterizar las formas de inserción laboral de mujeres, que aparecen como mano de obra transitoria, en el mercado de trabajo frutihortícola marplatense. El trabajo femenino asalariado está presente en la actividad hortícola que se practica a campo y bajo cubierta y en cultivos frutícolas no tradicionales. La investigación nos ha permitido indagar cómo y por qué estas mujeres se insertan en la actividad agrícola, identificar los procesos laborales específicos que requieren su fuerza de trabajo, así como las modalidades de remuneración y la complementación con otras actividades económicas. La perspectiva de género en el análisis de la participación laboral pone en juego múltiples dimensiones de las relaciones laborales. Desde este enfoque, se procura examinar la participación de las mujeres en las actividades remuneradas, explorando algunos de los rasgos que la configuran