The hardware and the software details of a user-friendly, simple, flexible and inexpensive pulse programmer using programmable counters interfaced to a microprocessor are described. The control of the various parameters that are required for NMR applications is implemented using the microprocessor. The basic hardware is extendable to other applications which require programmable pulse trains.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new four-hole cylindrical cantilever probe is described which could be used for three-dimensional flow surveys. The probe is more compact than the usual cylindrical type allowing for closer approach to a boundary. The probe is robust and gives good reproducibility. It can be used for a wide range of pitch angle. Review of Scientific Instruments is copyrighted by The American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The basic goal of a proteomic microchip is to achieve efficient and sensitive high throughput protein analyses, automatically carrying out several measurements in parallel. A protein microchip would either detect a single protein or a large set of proteins for diagnostic purposes, basic proteome or functional analysis. Such analyses would include e.g. interactomics, general protein expression studies, detecting structural alterations or secondary modifications. Visualization of the results may occur by simple immunoreactions, general or specific labelling, or mass spectrometry. For this purpose we have manufactured chip-based proteome analysis devices that utilize the classical polymer gel electrophoresis technology to run one and two-dimensional gel electrophoresis separations of proteins in just a smaller size. In total, we manufactured three functional prototypes of which one performed a miniaturized one-dimensional gel electrophoresis (1-DE) separation, the second and third preformed two-dimensional gel electrophoresis (2-DE) separations. These microchips were successfully used to separate and characterize a set of predefined standard proteins, cell and tissue samples. Also, the miniaturized 2-DE (ComPress-2DE) chip presents a novel way of combining the 1st and 2nd dimensional separations, thus avoiding manual handling of the gels, eliminate cross-contamination, and make analyses faster and repeatability better. They all showed the advantages of miniaturization over the commercial devices; such as fast analysis, low sample- and reagent consumption, high sensitivity, high repeatability and inexpensive performance. All these instruments have the potential to be fully automated due to their easy-to-use set-up.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A comprehensive set of new configurations for the holographic simulation of a wide variety of mirrors is described. These holographically simulated mirrors (HSMs) have been experimentally realized and their imaging performance has been studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A circuit capable of producing bipolar square pulses of voltages up to +or-400 V, employing an integrated circuit timer and two mercury wetted relays is described. The frequency of the pulses can be varied from a cycle min-1 to 2 kHz. A variable temperature sample chamber and the temperature control and measurement circuits are also described. The performance of the circuit is evaluated using samples of TGS and NaNO2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract is not available.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The conformation of the peptide Boc-L-Met-Aib-L-Phe-OMe has been studied in the solid state and solution by X-ray diffraction and 1H n.m.r., respectively. The peptide differs only in the N-terminal protecting group from the biologically active chemotactic peptide analog formyl-L-Met-Aib-L-Phe-OMe. The molecules adopt a type-II beta-turn in the solid state with Met and Aib as the corner residues (phi Met = -51.8 degrees, psi Met = 139.5 degrees, phi Aib = 58.1 degrees, psi Aib = 37.0 degrees). A single, weak 4----1 intramolecular hydrogen bond is observed between the Boc CO and Phe NH groups (N---O 3.25 A, N-H---O 128.4 degrees). 1H n.m.r. studies, using solvent and temperature dependencies of NH chemical shifts and paramagnetic radical induced line broadening of NH resonances, suggest that the Phe NH is solvent shielded in CDCl3 and (CD3)2SO. Nuclear Overhauser effects observed between Met C alpha H and Aib NH protons provide evidence of the occurrence of Met-Aib type-II beta-turns in these solvents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a versatile but easy to make AC mutual inductance bridge. The bridge has been used over the temperature range 4-300 K and with applied magnetic fields up to 7 T. Representative data obtained on various types of magnetic systems are shown.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A period timing device suitable for processing laser Doppler anemometer signals has been described here. The important features of this instrument are: it is inexpensive, simple to operate, and easy to fabricate. When the concentration of scattering particles is low the Doppler signal is in the form of a burst and the Doppler frequency is measured by timing the zero crossings of the signal. But the presence of noise calls for the use of validation criterion, and a 5â8 cycles comparison has been used in this instrument. Validation criterion requires the differential count between the 5 and 8 cycles to be multiplied by predetermined numbers that prescribe the accuracy of measurement. By choosing these numbers to be binary numbers, much simplification in circuit design has been accomplished since this permits the use of shift registers for multiplication. Validation accuracies of 1.6%, 3.2%, 6.3%, and 12.5% are possible with this device. The design presented here is for a 16-bit processor and uses TTL components. By substituting Schottky barrier TTLs the clock frequency can be increased from about 10 to 30 MHz resulting in an extension in the range of the instrument. Review of Scientific Instruments is copyrighted by The American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radio frequency (R.F.) glow discharge polyterpenol thin films were prepared on silicon wafers and irradiated with I10+ ions to fluences of 1 Ã 1010 and 1 Ã 1012 ions/cm2. Post-irradiation characterisation of these films indicated the development of well-defined nano-scale ion entry tracks, highlighting prospective applications for ion irradiated polyterpenol thin films in a variety of membrane and nanotube-fabrication functions. Optical characterisation showed the films to be optically transparent within the visible spectrum and revealed an ability to selectively control the thin film refractive index as a function of fluence. This indicates that ion irradiation processing may be employed to produce plasma-polymer waveguides to accommodate a variety of wavelengths. XRR probing of the substrate-thin film interface revealed interfacial roughness values comparable to those obtained for the uncoated substrate's surface (i.e., both on the order of 5 Ã), indicating minimal substrate etching during the plasma deposition process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple instrument that can provide a sequence of timed pulses for first initiating a transient process and then enabling sampling and recording periodically during the course of the transient event is described. The time delay between the first of these sampling pulses and the start of the transient event is adjustable. This sequence generator has additional features that make it ideal for use in acquiring the waveforms when a storage oscilloscope is used as the recording device. For avoiding the clutter caused by many waveforms being recorded at the same place on an oscilloscope screen such features as displacements of waveforms in the X and Y directions and trace blanking at places where the waveform is not required, have been incorporated. This sequence generator has been employed to acquire a sequence of Raman scattered radiation signals from an adiabatically expanding saturated vapour probed by a flashlamp-pumped dye laser.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare the differences between forest management incorporating energy wood thinning and forest management based on silvicultural recommendations (baseline). Energy wood thinning was substituted for young stand thinning and the first commercial thinning of industrial wood. The study was based on the forest stand data from Southern Finland, which were simulated by the MOTTI-simulator. The main interest was to find out the climatic benefits resulting from carbon sequestration and energy substitution. The value of energy wood was set to substitute it for coal as an alternative energy fuel (emission trade). Other political instruments (Kemera subsidies) were also analysed. The largest carbon dioxide emission reductions were achieved as a combination of carbon sequestration and energy substitution (on average, a 26-90 % increase in discounted present value in the beginning of rotation) compared to the baseline. Energy substitution increased emission reductions more effectively than carbon sequestration, when maintaining dense young stands. According to the study, energy wood thinning as a part of forest management was more profitable than the baseline when the value of carbon dioxide averaged more than 15 â¬/CO2 and other political subsidies were unchanged. Alternatively, the price of energy wood should on average exceed 21 â¬/m3 on the roadside in order to be profitable in the absence of political instruments. The most cost-efficient employment of energy wood thinning occured when the dominant height was 12 meters, when energy substitution was taken into account. According to alternative forest management, thinning of sapling stands could be done earlier or less intensely than thinning based on silvicultural recommendations and the present criteria of subsidies. Consequently, the first commercial thinning could be profitable to carry out either as harvesting of industrial wood or energy wood, or as integrated harvesting depending on the costs of the harvesting methods available and the price level of small-size industrial wood compared to energy wood.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

- Problem Climate change is affecting the world in numerous ways such as increased temperatures, sea level rise, and increased droughts and floods. Governments worldwide, especially in the most vulnerable countries, are urged to seek better solutions for sustainable development. The construction industry and buildings have enormous impacts on humans and the environment, meaning green building must be one of the solutions. Government involvement is widely considered as one of the essential and most effective ways to promote green building and drive the construction market towards sustainability. This paper will review green building policy of the Pacific-Rim countries that are most vulnerable to climate change according to the recent Standard and Poorâs ranking, including: Cambodia, Vietnam, Fiji, Philippines, Papua New Guinea and Indonesia. Methodology: This paper will review policy related publications including journal and conference papers, portal websites of governments, legislation documents and reports of international organisations. It will focus on the policies and governmental instruments that support the adoption of green building practices. - Findings All six governments have launched climate change adaptation policies, showing a great concern regarding the damages caused by the phenomenon. All countries except Papua New Guinea have promulgated energy efficiency policy and programs which indirectly promote the adoption of green building practices. The comparison study shows that Philippines and Indonesia motivate the adoption of renewable energy generation, energy efficiency and green building through either financial or advocacy instruments, while other four countries tend to implement regulatory tools to mandate energy conservation. Through comparison, Cambodia and Vietnam â the two countries providing vision to develop green building - can learn from Philippines and Indonesiaâs policy and instruments. - Research limitations Language differences between the countries and limit of formal sources may pose difficulties in searching for information. While much English language literature exists, sources from Cambodia, Philippines and Indonesia are less accessible. - Takeaway for practice As the paper provides more understanding about the supportive policy of those countries, it will introduce more opportunities for green property developers to invest in construction markets of those Pacific-Rim countries. - Originality There is little research reviewing green building supportive policies of developing and less-wealthy countries that are forecasted to be most vulnerable and most impacted by climate change. The originality of this paper lies in its investigation on how those countries intend to respond to this phenomenon and whether and to what extent they support the green building market by using policy tools.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare lens dimensions and refractive index distributions in type 1 diabetes and age-matched control groups. Methods: There were 17 participants with type 1 diabetes, consisting of two subgroups (7 young [23 ± 4 years] and 10 older [54 ± 4 years] participants), with 23 controls (13 young, 24 ± 4 years; 10 older, 55 ± 4 years). For each participant, one eye was tested with relaxed accommodation. A 3T clinical magnetic resonance imaging scanner was used to image the eye, employing a multiple spin echo (MSE) sequence to determine lens dimensions and refractive index profiles along the equatorial and axial directions. Results: The diabetes group had significantly smaller lens equatorial diameters and larger lens axial thicknesses than the control group (diameter mean ± 95% confidence interval [CI]: diabetes group 8.65 ± 0.26 mm, control group 9.42 ± 0.18 mm; axial thickness: diabetes group 4.33 ± 0.30 mm, control group 3.80 ± 0.14 mm). These differences were also significant within each age group. The older group had significantly greater axial thickness than the young group (older group 4.35 ± 0.26 mm, young group 3.70 ± 0.25 mm). Center refractive indices of diabetes and control groups were not significantly different. There were some statistically significant differences between the refractive index fitting parameters of young and older groups, but not between diabetes and control groups of the same age. Conclusions: Smaller lens diameters occurred in the diabetes groups than in the age-matched control groups. Differences in refractive index distribution between persons with and without diabetes are too small to have important effects on instruments measuring axial thickness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The proton NMR spectra of N-methylpyrrole oriented in the nematic phases of liquid crystals with positive and negative diamagnetic anisotropies and their mixtures are reported. Geometrical parameters derived from the spectra at the critical point in the mixture of liquid crystals with positive and negative diamagnetic anisotropies, where macroscopic diamagnetic anisotropy vanishes, are similar to those obtained in the solvent with negative diamagnetic anisotropy. However, significant distortions in the molecular structure attributed to solvent effects have been observed in liquid crystals with positive diamagnetic anisotropy. The minimum energy conformation has one C---H of the methyl perpendicular to the ring.