996 resultados para Hernia de disco
Resumo:
This article talks about the relationship between the body and sign, from the ideas of the Bakhtin Circle. The corpus analyzed is the spectacle Body (2000), designed from a disk of the same title (2000), by Arnaldo Antunes (AA). The aim is to reflect on the expressiveness of the body as a sign and the signic body, since the dialogue between the word (the song) and the body in action makes up the human architectural spectacle.
Resumo:
The aim of this study was to evaluate the stability of the conservative condylectomy technique and articular disc repositioning as the surgical treatment approach for management of mandibular condylar osteochondroma, with appropriate Orthognathic surgery. Fifteen patients (12 females and 3 males), average age of 32.3 years (range, 13 to 56 years), with unilateral active osteochondroma of the mandibular condyle were analyzed. All patients underwent conservative condylectomy, recontouring of the remaining condylar neck stump and articular disc repositioned and indicated orthognatic surgical procedures. Average post surgical follow-up was 19 months. Each patient's lateral cephalograms were traced at 3 intervals (presurgery, immediate post surgery and long-term follow-up). Immediate after surgery the oclusal plane angle decreased -2.8 ± 4.5o, the maxillomandibular complex rotated counter-clockwise with advancement at menton 5.3 ± 5.6 mm, pogonion 5.0 ± 5.1 mm, B point 3.4 ± 4.2 mm and A point 1.0 ± 1.5 mm. The long-term follow-up showed significant changes in overbite (-0.6 ± 0.5 mm) and SNGoMe (0,93° ± 1,53°). Horizontally and vertically small instabilities occurred in Me (-1.21 ± 1.94 mm) and PNS (-1.48 ± 1.67 mm) respectively. The treatment protocol studied produced counterclockwise rotation and maxillofacial mandibular advancement. The long-term follow-up showed solid dental and skeletal stability with horizontal instability of Me and PNS in the vertical direction.
Resumo:
The main objective of this work was to mount and test an experimental model to measure the hydraulic conductance of ex vivo dentin. Seventeen healthy third molars, with indication of extraction of healthy donors aged between 15 and 30 years were obtained by informed consent. After cleaning them, disinfecting them, including them in resin epoxy and cutting them, there were 17 samples of dentin, corresponding to a disk of resin with a coronal section of tooth showing the dentin exposed on both sides of it. Three machines to measure the hydraulic conductance of the dentin were assembled according to the description of the model of Pashley. Samples were installed in a Chamber of diffusion, connected by using silicone tubes to a graduated transfer pipette and a 20cm water column. Through the displacement of a bubble of water in the inside of the pipette, the hydraulic conductance of each sample was measured 3 times on the 14th, 21st, 28th and 35th day post extraction. The data were tabulated and analyzed statistically. There is no SS difference in the rate of flow of a measured sample in the three machines (p=0.5937). There is no SS difference in measurements of the hydraulic conductance of 13 samples of human dentin measured in days 14, 21, 28 and 35 postextraction (p=0.0704). It is possible to mount an experimental model to study the hydraulic conductance of dentin ex vivo, based on the model of Pashley. The model seems to be reliable, but more research is needed in order to validate its reliability.
Resumo:
ABSTRACT. Introduction: an in vitro model was used to measure the hydraulic conductance in human dentin discs treated with oxalic acid for 15, 30 or 60 s maintaining the occlusive effect and measuring 7 and 14 days after application. Methods: 45 dentin discs measuring 1 mm thick were obtained from human third molars which were free of caries and in no occlusion; the samples were obtained from patients aged 16 to 30 years. Discs were sorted out into three study groups (n = 15) depending on the time of application of a commercial solution of oxalate-based dentin desensitizer (DD) (BisBlock®) which contains ˂ 5% oxalic acid of 1.5-1.8 pH: in group A the agent was applied for 15 s, in group B it was applied for 30 s, and in group C for 60 s. The hydraulic conductance of each disc was calculated after acid etching, which corresponds to the maximum permeability of discs (100%) after immediate application of oxalic acid, as well as seven and fourteen days of storage in saline solution. The statistical analysis was done with ANOVA test and post-hoc Games-Howell test. Results: 35,46 ± 23.41% in Group A, 36.34 ± 15.88% in Group B and 24.99 ± 14.99% in Group C, showing that the use of DD for 15, 30 or 60 s decreased permeability in a statistically significant manner (p <0.05). Conclusions: DD was effective in reducing hydraulic conductance regardless of application time, but this reduction was temporary only, since after seven days permeability returns to values close to those of baseline.
Resumo:
Objective. The objective of this study was to evaluate the antimicrobial activity of the silver nanoparticles solution in enterococcus faecallis cultures (ATCC 29212), compared with various solutions of sodium hypoclorithe (NaOCl). Material and methods. Five Agar Petri plates were inoculated with E. faecallis and each of them was placed a cellulose dish embedded with silver nanoparticles solution, or a solution of sodium hypochlorite evaluated (Viarzon, Cloralex, Clorox). Chlorhexidine digluconate 2% was used as positive control and sterile saline solution was used as negative control. After 24 hours of incubation at 37ºc, under aerobic conditions, the zones of inhibition of bacterial growth were measured and the results subjected to the statistical t test among the experimental groups (= 5%). Results. The Cloralex showed to be the most effective reflected in the extent of inhibition in relation to other substances (p< 0.05), except that the chlorhexidine digluconate 2% (p> 0.05). The solution of silver nanoparticles provided a greater zone of inhibition than the sodium hypochlorite solution (Clorox) and Viarzon (p< 0.05). Clorox and Viarzon didn't provide zones of inhibition and were similar to each other (p> 0.05). Conclusions. The solution of silver nanoparticles presents antimicrobial activity in cultured E. faecallis, even higher than other commercial forms of sodium hypochlorite. Further studies should be carried out to determine its viability as irrigating solution in endodontics (AU)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Microbiologia - IBILCE
Resumo:
Soil compaction is one of the limiting factors in areas subjected to direct seeding. The method used to break up the compacted layer should disturb the soil as little as possible, as well as maintain the ground cover. The aim of this study was to evaluate the influence of subsoiling, scarification and use of shaft-type furrowing mechanisms when sowing, on preserving the ground cover, water content and soil density, as well as the effects on maize yield in a dystroferic Red Nitosol, cultivated under a system of direct seeding for ten years. The experimental design was of randomised blocks, with eight soil management treatments: subsoiling to a depth of 0.40 m before sowing the winter crop, subsoiling to 0.40 m before sowing the maize, scarification to 0.30 m before the winter crop, scarification to 0.30 m before the maize, scarification to 0.20 m before the winter crop, scarification to 0.20 m before the maize, direct seeding of the maize with a shaft-type furrowing mechanism and direct seeding of the maize using a double disc furrower. There were four replications. Subsoiling and scarification influenced the preservation of the ground cover, soil density and water content immediately after sowing, but did not interfere in plant development or grain yield in the maize crop. The use of shaft-type furrowing mechanisms in the sowing operation had no effect on any of the parameters under study.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We review five years experience on inguinal hernia repair under local anesthesia in a small hospital in the interior of the State of São Paulo, Brazil. Sixty patients were submitted to repair and they were evaluated according to their immediate results, kind of hernia, anesthetic and operatory techniques and recurrences. The results were considered excellent in 20% of the cases, good in 65%, regular in 13.3% and in 1.7% the results were bad. No recurrence was observed up to now. Most of the patients were discharged within 24 hours. The proposed technique has provided reduced hospital expenses and low risks of infection.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT