967 resultados para Graph


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

针对目前TCG组织定义的远程证明信任链模型在描述基于属性的远程证明时存在的不足,通过对基于属性远程证明过程中的证明请求、可信策略以及可信性评估过程进行抽象,提出了一个新的基于属性的远程证明模型。该模型将传统远程证明中信任链模型扩展为信任图,使得模型能够表达更为灵活的可信策略。还对可信策略的属性可信性判定问题以及可信评估过程终止性问题进行了讨论,给出了相关定理及证明,为可信策略的定义与检查提供了理论基础。基于该模型给出了实现可信网络接入时的可信策略定义,用实例验证了该模型在描述能力方面的增强。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

IEEE Comp Soc, IFIP, Tianjin Normal Univ

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Feature-based image watermarking schemes, which aim to survive various geometric distortions, have attracted great attention in recent years. Existing schemes have shown robustness against rotation, scaling, and translation, but few are resistant to cropping, nonisotropic scaling, random bending attacks (RBAs), and affine transformations. Seo and Yoo present a geometrically invariant image watermarking based on affine covariant regions (ACRs) that provide a certain degree of robustness. To further enhance the robustness, we propose a new image watermarking scheme on the basis of Seo's work, which is insensitive to geometric distortions as well as common image processing operations. Our scheme is mainly composed of three components: 1) feature selection procedure based on graph theoretical clustering algorithm is applied to obtain a set of stable and nonoverlapped ACRs; 2) for each chosen ACR, local normalization, and orientation alignment are performed to generate a geometrically invariant region, which can obviously improve the robustness of the proposed watermarking scheme; and 3) in order to prevent the degradation in image quality caused by the normalization and inverse normalization, indirect inverse normalization is adopted to achieve a good compromise between the imperceptibility and robustness. Experiments are carried out on an image set of 100 images collected from Internet, and the preliminary results demonstrate that the developed method improves the performance over some representative image watermarking approaches in terms of robustness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polyaniline-camphorsulfonic acid (PAN-CSA) composite film on platinum electrode surface has been synthesized via the electrochemical polymerization of aniline in the presence of camphorsulfonic acid (CSA). It was found that the doping of polyaniline (PAN) with CSA extends the electroactivity of PAN in neutral and even in alkaline media. The PAN-CSA composite film coated platinum electrodes are shown to be good electrocatalytic surfaces for the oxidation of ascorbic acid (AA) in phosphate buffer solution (PBS) of pH 7.0. The anodic peak potential of AA shifts from 0.63 V at the bare platinum electrode to 0.34 V at the PAN-CSA composite modified platinum electrode with a greatly enhanced current response. A linear calibration graph is obtained over the AA concentration range of 5-50 mM using cyclic voltammetry. The kinetics of the catalytic reaction are investigated using rotating disk electrode voltammetry and chronoamperometry. The results are explained using the theory of electrocatalytic reactions at chemically modified electrodes. The PAN-CSA composite on the electrode surface shows good reproducibility and stability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel edge degree f(i) for heteroatom and multiple bonds in molecular graph is derived on the basis of the edge degree delta(e(r)). A novel edge connectivity index F-m is introduced. The multiple linear regression by using the edge connectivity index F-m and alcohol-type parameter delta, alcohol-distance parameter L can provide high-quality QSPR models for the normal boiling points (BPs), molar volumes (MVs), molar refraction (MRs), water solubility(log(1/S)) and octanol/water partition (logP) of alcohols with up to 17 non-hydrogen atoms. The results imply that these physical properties may be expressed as a liner combination of the edge connectivity index and alcohol-type parameter, 6, alcohol-distance parameter, L. For the models of the five properties, the correlation coefficient r and the standard errors are 0.9969,3.022; 0.9993, 1.504; 0.9992, 0.446; 0.9924,0.129 and 0.9973,0.123 for BPs, MVs, MRs, log(1/S) and logP, respectively. The cross-validation by using the leave-one-out method demonstrates the models to be highly reliable from the point of view of statistics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is necessary to generate the automorphism group of a chemical graph in computer-aided structure elucidation. In this paper, an algorithm was developed by the all-paths topological symmetry algorithm to build the automorphism group of a chemical graph. A comparison of several topological symmetry algorithms reveals that the all-paths algorithm (APA) could yield the correct class of a chemical graph. It lays a foundation for the ESESOC system in computer-aided structure elucidation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is necessary to generate automorphism group of chemical graph in computer-aided structure eluciation. In this paper, an algorithm is developed by all-path topological symmetry algorithm to build automorphism group of chemical graph. A comparison of several topological symmetry algorithm reveals that all-path algorthm can yield correct of class of chemical graph. It lays a foundation for ESESOC system for computer-aided structure elucidation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with end-column electrochemical detection (EC) of barbituric acid (BA) and 2-thiobarbituric acid (TA) has been described. Under optimum condition, BA and TA were separated satisfactorily, and a response of high sensitivity and stability was obtained at a detection potential of 1.25 V versus Ag/AgCl. Optimized end-column detection provides detection limit as low as 0.5 and 0.1 mu M for BA and TA, respectively. The calibration graph was linear over three orders of magnitude. The relative standard deviations (n = 10) of peak currents and migration times obtained for both BA and TA were 3.4, 3.7, and 1.7, 1.2%, respectively. The proposed method has been applied to analyze water sample with satisfactory results. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

(A) novel chemiluminescence (CL) system was evaluated for the determination of hydrogen peroxide, glucose and ascorbic acid based on hydrogen peroxide, which has a catalytic-cooxidative effect on the oxidation of luminol by KIO4. Hydrogen peroxide can be directly determined by luminol-KIO4 -H2O2 CL system. The detection limit was 3.0 x 10(-8) mol l(-1) and the calibration graph was linear over the range of 2.0 x 10(-7)-6.0 x 10(-4) mol l(-1). The relative standard deviation of H2O2 was 1.1% for 2.0 x 10(-6) mol l(-1) (N = 11). Glucose was indirectly determined through measuring the H2O2 generated by the oxidation of glucose in the presence of glucose oxidase at pH 7.6. The present method provides a source for H2O2, which, in turn, coupled with the luminol-KIO4-H2O2 CL reaction system. The CL was linearly correlated with glucose concentration of 0.6-110 mu g ml(-1). The relative standard deviation was 2.1% for 10 mu g ml(-1) (N = 11). Detection limit of glucose was 0.08 mu g ml(-1). Ascorbic acid was also indirectly determined by the suppression of luminol-KIO4-H2O2 CL system. The calibration curve was linear over the range of 1.0 x 10(-7)-1.0 x 10(-5) mol l(-1) of ascorbic acid. The relative standard deviation was 1.0% for 8.0 x 10(-7) mol l(-1) (N = 11). Detection limit of ascorbic acid was 6.0 x 10(=8) mol l(-1). These proposed methods have been applied to determine glucose, ascorbic acid in tablets and injection. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with end-column electrochemical detection (EC) of sulfadiazine (SDZ) and sulfamethoxazole (SMZ) is described. Under the optimum conditions, SDZ and SMZ were separated satisfactorily, and a highly sensitive and stable response was obtained at a potential of 1.1 V versus Ag/AgCl. Optimized end-column detection provides detection limits as low as 0.1 mu M for both compounds, which corresponds to 0.024 and 0.021 fmol with peak efficiencies of 394000 and 335000 theoretical plates for SDZ arid SMZ, respectively. The calibration graph was linear over three orders of magnitude. The relative standard deviations (n = 12) of peak currents and migration times were 2.3 and 2.7%, and 0.8 and 1.3%, respectively, for the two compounds. The proposed method was applied to the analysis of tablets and human urine samples with satisfactory results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method to assign a single number representation for each atom (node) in a molecular graph, Atomic IDentification (AID) number, is proposed based on the counts of weighted paths terminated on that atom. Then, a new topological index, Molecular IDentification (MID) number is developed from AID. The MID is tested systematically, over half a million of structures are examined, and MID shows high discrimination for various structural isomers. Thus it can be used for documentation in the Changchun Institute of Chemistry C-13 NMR information system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An electrochemical pretreatment regime for a cylindrical carbon fibre microelectrode was optimized for the determination of aminopyrine (AM) and its metabolite 4-aminoantipyrine (AAN) by capillary electrophoresis (CE)-electrochemical detection (ED). Under optimized conditions, a response of high sensitivity and stability was obtained for AM and AAN at a detection voltage as low as 0.9 V following CE-ED, by which AM and AAN were separated satisfactorily. The calibration graph was linear over three orders of magnitude and the limits of detection for AM and AAN were in the femtomole range.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A reversed-phase high-performance liquid chromatographic method with amperometric detection is described for the separation and quantification of uric acid, guanine, hypoxanthine and xanthine. The isocratic separation of a standard mixture of the compounds was achieved in 5 min on a Spherisorb 5 C-18 reversed-phase column, with a mobile phase of NaH2PO4 (300 mmol dm(-3) pH 3.0)-methanol-acetonitrile-tetrahydrofuran (97.8 + 0.5 + 1.5 + 0.2). Uric acid, guanine, hypoxanthine and xanthine were completely separated, with detection limits in the range 2-20 pmol per injection. The effect of pH and the composition of the mobile phase on the separation are described. The hydrodynamic voltammograms of these compounds were recorded at a glassy carbon electrode. The linear range of the calibration graph for each compound was: uric acid; 1-5000 mu mol dm(-3); guanine, 0.5-2000 mu mol dm(-3); hypoxanthine, 0.1-500 mu mol dm(-3) and xanthine, 0.5-5000 mu mol dm(-3). The within- and between-day precision was good. The uric acid and hypoxanthine content in human plasma was measured using the proposed method. Good recoveries of uric acid (97.9-103%), hypoxanthine (98.0-99.2%), guanine (96.0-98.3%) and xanthine (96.0-102%) were obtained from human plasma. The results of electrochemical detection were in good agreement with those of UV detection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new algorithm for deriving canonical numbering of atoms in a molecular graph has been developed. Some graph invariants, such as node properties, degree (connectivity), topological path, the smallest node ring index, etc., are encoded together to partit