976 resultados para Free volume
Resumo:
Despite increasing numbers of women attaining higher level academic degrees, gender disparities remain among higher education and among university faculties. Some have posited that this may stem from inadequate academic identity development of women at the doctoral level. While existing gender differences may stem from multiple and variable origins, mentoring has been proposed as a viable means to promote academic identity development and address these gender gaps. This study used a qualitative, narrative case study design to evaluate "StartingDoc" a structured mentoring program launched among Swiss Universities aimed at promoting networking and academic identity development among female doctoral students. Herein we describe the 9 emergent themes which arose from the small-group mentoring program and suggest that such an approach is both feasible and beneficial for young female academics. Further work is needed to elucidate the most effective strategies for developing and retaining women in academia.
Resumo:
This letter discusses the detection and correction ofresidual motion errors that appear in airborne synthetic apertureradar (SAR) interferograms due to the lack of precision in the navigationsystem. As it is shown, the effect of this lack of precision istwofold: azimuth registration errors and phase azimuth undulations.Up to now, the correction of the former was carried out byestimating the registration error and interpolating, while the latterwas based on the estimation of the phase azimuth undulations tocompensate the phase of the computed interferogram. In this letter,a new correction method is proposed, which avoids the interpolationstep and corrects at the same time the azimuth phase undulations.Additionally, the spectral diversity technique, used to estimateregistration errors, is critically analyzed. Airborne L-bandrepeat-pass interferometric data of the German Aerospace Center(DLR) experimental airborne SAR is used to validate the method
Resumo:
Hypernatremia is defined as a serum sodium concentration above the upper laboratory reference range, usually > 145 mmol/l. It is a common electrolyte disorder in the very young and the very old patient. Hospitalization itself is a risk factor for developing hypernatremia. Free water deficit is the main cause of this condition. It induces hyperosmolality and an intracellular dehydration. Clinical manifestations are mostly neurological but non-specific. A blood sample analysis is needed to establish the diagnosis. Hypernatremia is associated with a high mortality and morbidity. Treatment consists of correcting the underlying cause and the volume deficit. A brief review of this condition is proposed.
Resumo:
OBJECTIVE: To assess the suitability of a hot-wire anemometer infant monitoring system (Florian, Acutronic Medical Systems AG, Hirzel, Switzerland) for measuring flow and tidal volume (Vt) proximal to the endotracheal tube during high-frequency oscillatory ventilation. DESIGN: In vitro model study. SETTING: Respiratory research laboratory. SUBJECT: In vitro lung model simulating moderate to severe respiratory distress. INTERVENTION: The lung model was ventilated with a SensorMedics 3100A ventilator. Vt was recorded from the monitor display (Vt-disp) and compared with the gold standard (Vt-adiab), which was calculated using the adiabatic gas equation from pressure changes inside the model. MEASUREMENTS AND MAIN RESULTS: A range of Vt (1-10 mL), frequencies (5-15 Hz), pressure amplitudes (10-90 cm H2O), inspiratory times (30% to 50%), and Fio2 (0.21-1.0) was used. Accuracy was determined by using modified Bland-Altman plots (95% limits of agreement). An exponential decrease in Vt was observed with increasing oscillatory frequency. Mean DeltaVt-disp was 0.6 mL (limits of agreement, -1.0 to 2.1) with a linear frequency dependence. Mean DeltaVt-disp was -0.2 mL (limits of agreement, -0.5 to 0.1) with increasing pressure amplitude and -0.2 mL (limits of agreement, -0.3 to -0.1) with increasing inspiratory time. Humidity and heating did not affect error, whereas increasing Fio2 from 0.21 to 1.0 increased mean error by 6.3% (+/-2.5%). CONCLUSIONS: The Florian infant hot-wire flowmeter and monitoring system provides reliable measurements of Vt at the airway opening during high-frequency oscillatory ventilation when employed at frequencies of 8-13 Hz. The bedside application could improve monitoring of patients receiving high-frequency oscillatory ventilation, favor a better understanding of the physiologic consequences of different high-frequency oscillatory ventilation strategies, and therefore optimize treatment.
Resumo:
A determinação do volume máximo de escoamento superficial é fundamental para o dimensionamento de diversos tipos de obras hidráulicas, constituindo o parâmetro de maior importância no projeto de sistemas de terraceamento em nível. A determinação incorreta do volume escoado superficialmente gera imprecisões no dimensionamento destes sistemas que, quando superdimensionados, apresentam elevado custo de instalação. Tendo em vista esses aspectos, o presente trabalho teve por objetivo comparar os valores de volume máximo de escoamento superficial, obtidos por meio do método empírico do número da curva, desenvolvido pelo Serviço de Conservação de Solos dos Estados Unidos, com aqueles obtidos por meio do método desenvolvido por Pruski e colaboradores, baseado em princípios consagrados na hidrologia. O desempenho dos dois métodos foi analisado com base nas condições pluviométricas correspondentes a Belo Horizonte e Uberlândia, para período de retorno de 10 anos. Evidenciaram-se grandes diferenças entre os valores de volume de escoamento superficial obtidos pelos dois métodos, as quais se mostraram mais acentuadas para maiores velocidades de infiltração de água no solo, tendo o método proposto por Pruski e colaboradores apresentado comportamento mais condizente com a realidade.
Resumo:
The authors developed a free-breathing black-blood coronary magnetic resonance (MR) angiographic technique with a potential for exclusive visualization of the coronary blood pool. Results with the MR angiographic technique were evaluated in eight healthy subjects and four patients with coronary disease identified at conventional angiography. This MR angiographic technique accurately depicted luminal disease in the patients and permitted visualization of extensive continuous segments of the native coronary tree in both the healthy subjects and the patients. Black-blood coronary MR angiography provides an alternative source of contrast enhancement.
Resumo:
BACKGROUND: Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the effect of a T2 preparation prepulse (T2prep) for myocardial suppression and a shortened acquisition window on coronary definition. METHODS AND RESULTS: Eight healthy adult subjects and 5 patients with confirmed coronary artery disease (CAD) underwent free-breathing 3D MRA with and without T2prep and with 120- and 60-ms data-acquisition windows. The T2prep resulted in a 123% (P<0. 001) increase in contrast-to-noise ratio (CNR). Coronary edge definition was improved by 33% (P<0.001). Acquisition window shortening from 120 to 60 ms resulted in better vessel definition (11%; P<0.001). Among patients with CAD, there was a good correspondence with disease. CONCLUSIONS: Free-breathing, T2prep, 3D coronary MRA with a shorter acquisition window resulted in improved CNR and better coronary artery definition, allowing the assessment of coronary disease. This approach offers the potential for free-breathing, noninvasive assessment of the major coronary arteries.
Resumo:
OBJECTIVES: To evaluate morbidity associated with the radial forearm free flap donor site and to compare functional and aesthetic outcomes of ulnar-based transposition flap (UBTF) vs split-thickness skin graft (STSG) closure of the donor site.¦DESIGN: Case-control study.¦SETTING: Tertiary care institution.¦PATIENTS: The inclusion criteria were flap size not exceeding 30 cm(2), patient availability for a single follow-up visit, and performance of surgery at least 6 months previously. Forty-four patients were included in the study and were reviewed. Twenty-two patients had UBTF closure, and 22 had STSG closure.¦MAIN OUTCOME MEASURES: Variables analyzed included wrist mobility, Michigan Hand Outcomes Questionnaire scores, pinch and grip strength (using a dynamometer), and hand sensitivity (using monofilament testing over the radial nerve distribution). In analyses of operated arms vs nonoperated arms, variables obtained only for the operated arms included Vancouver Scar Scale scores and visual analog scale scores for Aesthetics and Overall Arm Function.¦RESULTS: The mean (SD) wrist extension was significantly better in the UBTF group (56.0° [10.4°] for nonoperated arms and 62.0° [9.7°] for operated arms) than in the STSG group (59.0° [7.1°] for nonoperated arms and 58.4° [12.1°] for operated arms) (P = .02). The improvement in wrist range of motion for the UBTF group approached statistical significance (P = .07). All other variables (Michigan Hand Outcomes Questionnaire scores, pinch and grip strength, hand sensitivity, and visual analog scale scores) were significantly better for nonoperated arms vs operated arms, but no significant differences were observed between the UBTF and STSG groups.¦CONCLUSIONS: The radial forearm free flap donor site carries significant morbidity. Donor site UBTF closure was associated with improved wrist extension and represents an alternative method of closure for small donor site defects.
Resumo:
OBJECTIVE: Diaphragmatic navigators are frequently used in free-breathing coronary MR angiography, either to gate or prospectively correct slice position or both. For such approaches, a constant relationship between coronary and diaphragmatic displacement throughout the respiratory cycle is assumed. The purpose of this study was to evaluate the relationship between diaphragmatic and coronary artery motion during free breathing. SUBJECTS AND METHODS: A real-time echoplanar MR imaging sequence was used in 12 healthy volunteers to obtain 30 successive images each (one per cardiac cycle) that included the left main coronary artery and the domes of both hemidiaphragms. The coronary artery and diaphragm positions (relative to isocenter) were determined and analyzed for effective diaphragmatic gating windows of 3, 5, and 7 mm (diaphragmatic excursions of 0-3, 0-5, and 0-7 mm from the end-expiratory position, respectively). RESULTS: Although the mean slope correlating the displacement of the right diaphragm and the left main coronary artery was approximately 0.6 for all diaphragmatic gating windows, we also found great variability among individual volunteers. Linear regression slopes varied from 0.17 to 0.93, and r2 values varied from .04 to .87. CONCLUSION: Wide individual variability exists in the relationship between coronary and diaphragmatic respiratory motion during free breathing. Accordingly, coronary MR angiographic approaches that use diaphragmatic navigator position for prospective slice correction may benefit from patient-specific correction factors. Alternatively, coronary MR angiography may benefit from a more direct assessment of the respiratory displacement of the heart and coronary arteries, using left ventricular navigators.
Resumo:
Résumé: Les environnements hémodynamiques, favorisant ou protégeant contre la formation de la plaque, induisent tout deux une augmentation de la production d'anion superoxide dans les cellules endothéliales (ECs). Par ailleurs, une régulation différente de l'expression des gènes a été décrite dans les cellules exposées à ces différentes conditions. Dans le but d'investiguer le rôle de l'augmentation du stress oxydatif dans l'expression des gènes régulée par le flux, nous avons d'abord exposé les EC à un flux unidirectionnel, non pulsé. Dans ces conditions, l'état oxydatif des cellules endothéliales est augmenté de façon transitoire. L'expression du gène de l'endothéline 1 (ET-1) est aussi induite de façon transitoire par un tel flux, alors que l'expression du gène de la nitiric oxyde synthase endothéliale (NOS III) est stimulé de façon durable. Au contraire, un flux unidirectionnel pulsé, qui induit une augmentation durable de la production d'anion superoxide, augmente aussi de façon durable l'expression des gènes de ET-1 comme de NOS III. Un flux oscillatoire (favorisant la plaque), qui lui aussi ,a des effets à long terme sur la production d'anion superoxide, a uniquement augmenté l'expression de ET-1. De plus, l'utilisation d'un antioxydant, a seulement partiellement inhibé la stimulation de l'expression du gène NOS III par le flux unidirectionnel pulsé, alors qu'il a complètement abrogé la stimulation de l'expression du gène ET-1 par le flux unidirectionnel pulsé et oscillatoire. Ceci suggère que les forces mécaniques régulent l'expression des gènes dans les EC par un double mécanisme dépendant et indépendant du stress oxidatif des cellules. Par ailleurs, ces résultats supportent ultérieurement l'hypothèse que la balance entre la réponse oxidative et anti-oxidante dans les cellules endothéliales exposées à un environnement hémodynamique est une des clés de la prédisposition à un dysfonctionnement endothélial observé dans des régions exposées à des flux perturbés. Abstract: Both plaque-free and plaque-prone hemodynamic environments induce an increase in the oxidative state of endothelial cells (ECs), whereas differential gene expression regulation was described in cells exposed to these conditions. In order to investigate the role of the increased oxidative state in flow-regulation of gene expression, we first exposed EC to non-pulsed unidirectional shear stress. These conditions only slightly increases ECs oxidative state and endothelin-1 (ET-1) mRNA expression, whereas endothelial nitric oxide synthase (NOS III) mRNA level were significantly up-regulated. On the contrary, both ET-1 and NOS III gene expression were significantly induced in EC exposed to pulsed-unidirectional flow (plaque-free). Only ET-1 gene expression was up-regulated by oscillatory flow (plaque-prone). Moreover, use of an antioxidant only partially inhibited NOS III gene up-regulation by unidirectional flow, whereas it completely abrogated ET-1 gene up-regulation by unidirectional and oscillatory flows. Thus suggesting that mechanical forces regulate gene expression in ECs both via oxidative stress-dependent and -independent mechanisms.
Resumo:
BACKGROUND: We investigated whether the free β-human chorionic gonadotropin (free β-hCG) would provide additional information to that provided by total hCG alone and thus be useful in future epidemiological studies relating hCG to maternal breast cancer risk. MATERIALS & METHODS: Cases (n = 159) and controls (n = 286) were a subset of our previous study within the Northern Sweden Maternity Cohort on total hCG during primiparous pregnancy and breast cancer risk. RESULTS: The associations between total hCG (hazard ratio: 0.79; 95% CI: 0.49-1.27), free β-hCG (hazard ratio: 0.85; 95% CI: 0.33-2.18) and maternal risk of breast cancer were very similar in all analyses and mutual adjustment for either one had minor effects on the risk estimates. CONCLUSION: In the absence of a reliable assay on intact hCG, total hCG alone can be used in epidemiological studies investigating hCG and breast cancer risk, as free β-hCG does not appear to provide any additional information.
Resumo:
A produtividade das culturas agrícolas, associada às condições climáticas e edáficas, depende da disponibilidade de água e nutrientes no solo em época e quantidades apropriadas. A falta ou excesso de água no solo são fatores limitantes ao crescimento vegetal e podem diminuir a produtividade. Portanto, estudos que levem a um melhor entendimento de como a água se comporta na zona radicular de uma cultura agrícola no campo são de importância indiscutível ao adequado manejo agrícola. O objetivo do presente trabalho foi avaliar o método do balanço de água no solo aplicado ao volume de solo explorado pelo sistema radicular de uma planta de citros, considerando cinco profundidades de solo e cinco distâncias horizontais do tronco em duas direções a partir do tronco (uma ao longo e outra perpendicular à linha de plantas) e, então, verificar a contribuição de cada uma das camadas de solo avaliadas à evapotranspiração real da planta. O experimento foi realizado num Latossolo Vermelho-Amarelo distrófico argissólico em um pomar de citros, no município de Piracicaba (SP), durante dois períodos, um seco (40 dias) e um chuvoso (37 dias). Para atender ao objetivo proposto, um conjunto de 25 tensiômetros (cinco profundidades x cinco distâncias do tronco) foi instalado ao longo da linha e um outro, idêntico, perpendicular à linha, em direção à entrelinha. A armazenagem foi calculada a partir das leituras dos dois conjuntos de 25 tensiômetros cujos potenciais mátricos determinados foram convertidos em umidades volumétricas pelas curvas de retenção da água no solo. A drenagem interna e a ascensão capilar foram estimadas a partir das leituras diárias dos tensiômetros e da função K(fim) (condutividade hidráulica em função do potencial mátrico), por meio da equação de Darcy-Buckingham. Esta função K(fim) para cada profundidade foi determinada pelo método do perfil instantâneo realizado em área adjacente. A precipitação pluvial foi medida por pluviômetro com aquisição automática de dados instalado na área. Os resultados obtidos mostraram que o método do balanço de água proposto foi adequado para avaliar quanto cada camada de solo da zona radicular da planta contribuiu para o consumo total de água (evapotranspiração real) da planta, nos dois períodos estudados. Nesse sentido, a camada de 0,00 a 0,60 m de profundidade mostrou ser a que a planta deva apresentar maior volume de raízes ativas, de acordo com sua maior contribuição ao consumo de água pela planta.