999 resultados para FEA comparison
Resumo:
Three-dimensional free-breathing coronary magnetic resonance angiography was performed in eight healthy volunteers with use of real-time navigator technology. Images acquired with the navigator localized at the right hemidiaphragm and at the left ventricle were objectively compared. The diaphragmatic navigator was found to be superior for vessel delineation of middle to distal portions of the coronary arteries.
Resumo:
[spa] El estudio de los procesos a través de los cuales la economía política se ha transformado en una disciplina académica es un área de creciente interés en la historia del pensamiento económico. Dicho estudio se ha abordado a través del análisis de la importancia de la economía política en un conjunto de instituciones, consideradas clave en la expansión de la economía en las sociedades occidentales en la segunda mitad del siglo XIX y primeras décadas del XX: universidades, sociedades económicas, publicaciones periódicas de contenido económico y los parlamentos nacionales. Este papel presenta una comparación entre los desarrollos del proceso de institutionalización de la economía política en España e Italia, a través del estudio de la presencia de esta disciplina en las instituciones mencionadas para el periodo 1860-1900. El objetivo es medir la posible existencia de una vía común en la institucionalización de la economía política en ambos países, como un primer paso hacia la elaboración de un modelo supranacional de institucionalización de la economía en este periodo.
Resumo:
Background: Most patients miss occasional doses of antihypertensives. The use of 'forgiving' drugs (i.e. drugs with duration of action longer than the 24-h dosing interval) may allow an adequate blood pressure (BP) reduction to be maintained despite missed doses. Aim:To quantify the effects of adherence level and duration of action on estimated mean systolic BP (SBP) reduction and cardiovascular disease (CVD) risk. Method:For 1250 patients, we simulated 256-day dosing histories with realistically distributed drug holidays based on a study of electronically monitored dosing records. Adherence was set to the desired level by altering the proportion of doses missed. Mean office SBP-lowering effect (aliskiren 300 mg, -14.1 mmHg; irbesartan 300 mg, -13.3; ramipril 10 mg, -10.1 mmHg) and the rate of SBP increase after stopping treatment (off-rate; aliskiren, 1.0 mmHg/day; irbesartan, 3.6 mmHg/day; ramipril, 4.0 mmHg/day) were taken from the results of a randomised, double-blind trial. SBP was averaged over time and patient to estimate mean reductions in SBP and 10-year CVD risk (Framingham risk equation, baseline absolute 10-year CVD risk: 27%). Results:Predicted reductions in SBP and CVD risk with aliskiren were larger and less affected by imperfect adherence than the reductions with irbesartan or ramipril. For aliskiren, reducing adherence from 90% to 60% led to a predicted rise in SBP of 1.0 mmHg and three additional CVD events per 1000 treated patients; larger predicted differences were observed for irbesartan (2.5 mmHg; 7.5 events/1000 treated patients) and ramipril (2.2 mmHg; 6.7 events/1000 treated patients). Conclusion:To offset the effects of imperfect adherence, a common challenge with antihypertensives, for better BP management it may be prudent to prescribe 'forgiving' drugs.
Resumo:
We performed an analysis of a substudy of the randomized Tamoxifen Exemestane Adjuvant Multinational trial to determine the effects of exemestane (EXE) and tamoxifen (TAM) adjuvant treatment on bone mineral density (BMD) measured by dual-energy X-ray absorptiometry compared with the trabecular bone score, a novel grey-level texture measurement that correlates with 3-dimensional parameters of bone texture in postmenopausal women with hormone receptor-positive breast cancer for the first time. In total, 36 women were randomized to receive TAM (n = 17) or EXE (n = 19). Patients receiving TAM showed a mean increase of BMD in lumbar spine from baseline of 1.0%, 1.5%, and 1.9% and in trabecular bone score of 2.2%, 3.5%, and 3.3% at 6-, 12-, and 24-mo treatment, respectively. Conversely, patients receiving EXE showed a mean decrease from baseline in lumbar spine BMD of -2.3%, -3.6%, and -5.3% and in trabecular bone score of -0.9%, -1.7%, and -2.3% at 6-, 12-, and 24-mo treatment, respectively. Changes in trabecular bone score from baseline at spine were also significantly different between EXE and TAM: p = 0.05, 0.007, and 0.006 at 6, 12, and 24mo, respectively. TAM induced an increase in BMD and bone texture analysis, whereas EXE resulted in decreases. The results were independent from each other.
Resumo:
Background: TIDratio indirectly reflects myocardial ischemia and is correlated with cardiacprognosis. We aimed at comparing the influence of three different softwarepackages for the assessment of TID using Rb-82 cardiac PET/CT. Methods: Intotal, data of 30 patients were used based on normal myocardial perfusion(SSS<3 and SRS<3) and stress myocardial blood flow 2mL/min/g)assessed by Rb-82 cardiac PET/CT. After reconstruction using 2D OSEM (2Iterations, 28 subsets), 3-D filtering (Butterworth, order=10, ωc=0.5), data were automatically processed, and then manually processed fordefining identical basal and apical limits on both stress and rest images.TIDratio were determined with Myometrix®, ECToolbox® and QGS®software packages. Comparisons used ANOVA, Student t-tests and Lin concordancetest (ρc). Results: All of the 90 processings were successfullyperformed. TID ratio were not statistically different between software packageswhen data were processed automatically (P=0.2) or manually (P=0.17). There was a slight, butsignificant relative overestimation of TID with automatic processing incomparison to manual processing using ECToolbox® (1.07 ± 0.13 vs 1.0± 0.13, P=0.001)and Myometrix® (1.07 ± 0.15 vs 1.01 ± 0.11, P=0.003) but not using QGS®(1.02 ±0.12 vs 1.05 ± 0.11, P=0.16). The best concordance was achieved between ECToolbox®and Myometrix® manual (ρc=0.67) processing.Conclusion: Using automatic or manual mode TID estimation was not significantlyinfluenced by software type. Using Myometrix® or ECToolbox®TID was significantly different between automatic and manual processing, butnot using QGS®. Software package should be account for when definingTID normal reference limits, as well as when used in multicenter studies. QGS®software seemed to be the most operator-independent software package, whileECToolbox® and Myometrix® produced the closest results.
Resumo:
Summary
Resumo:
Ordering in a binary alloy is studied by means of a molecular-dynamics (MD) algorithm which allows to reach the domain growth regime. Results are compared with Monte Carlo simulations using a realistic vacancy-atom (MC-VA) mechanism. At low temperatures fast growth with a dynamical exponent x>1/2 is found for MD and MC-VA. The study of a nonequilibrium ordering process with the two methods shows the importance of the nonhomogeneity of the excitations in the system for determining its macroscopic kinetics.
Resumo:
Cyst-based ecotoxicological tests are simple and low-cost methods for assessing acute toxicity. Nevertheless, only a few comparative studies on their sensitivity are known. In the present study, the suitability of the use of two freshwater Anostracan species, Streptocephalus rubricaudatus and S. texanus, was assessed. The impact of 16 priority pollutants (4 heavy metals, 11 organic, and 1 organometallic compounds) on these two species, as well as on Artemia salina (Artoxkit M), Daphnia magna (International Organization for Standardization 6341), and S. proboscideus (Streptoxkit F) was assessed. For indicative comparison, bioassays using Brachionus calyciflorus (Rotoxkit F) and Photobacterium phosphoreum (Microtox) were also performed. For heavy metals (K2Cr2O7, Cd2+, Zn2+, Cu2+), the sensitivity of the two studied Streptocephalus species was slightly higher than that of D. magna. It was significantly more elevated than for the marine A. salina. For organic and organometallic micropollutants [phenol, 3,5-dichlorophenol, pentachlorophenol (PCP), hydroquinone, linear alkylbenzene sulfonate, sodium dodecyl sulfate, tributylphosphate, dimethylphthalate, atrazine, lindane, malathion, tributyltin chloride (TBT-Cl)], the sensitivity of the 4 anostracan species was of the same order of magnitude as that of D. magna. Artemia salina was slightly less sensitive to some organic compounds (PCP, hydroquinone, TBT-Cl). The sensitivity of S. rubricaudatus to organic solvents was low. On the other hand, this anostracan was quite sensitive to NaCl. Thus, its use is restricted to freshwater samples. The evaluation of global practicability of these two tests confirms that cyst-based freshwater anostracans may be used to perform low-cost tests at a sensitivity comparable to that of D. magna (24 h immobilization test).
Resumo:
Radioimmunotherapies with Zevalin® (RIT-Z) showed encouraging results in patients with relapsed/refractory follicular lymphoma (FL), leading frequently to failure-free intervals longer than those achieved by the last previous therapy. We compared time-to-event variables obtained before and after RIT-Z in patients with relapsed FL, previously exposed to rituximab. All patients with relapsed non-transformed, non-refractory, non-rituximab-naïve FL who have been treated with RIT-Z in two different centres in Europe were included. Staging and response were assessed by contrast-enhanced CT in all patients; PET/CT was performed according to local availability. Event-free survival (EFS) and time to next treatment (TTNT) following the last previous therapy and after RIT-Z were compared. Pre-therapy characteristics were tested in univariate analyses for prediction of outcomes. A description of the patterns of relapse was also provided. Among 70 patients treated, only 16 fulfilled the inclusion criteria. They were treated with a median of 3 prior lines of chemo-immunotherapies, including a median of 2 rituximab-containing regimens; 6 patients had undergone myeloablative chemotherapy with autologous stem cell rescue (ASCT). Overall response rates were 10 (62%) CR/CRu, 3 (19%) PR and 3 (19%) PD; response rates were similar in patients with prior ASCT. After RIT-Z only few patients obtained EFS and TTNT longer than after the last previous therapy. All four patients receiving rituximab maintenance were without progression 12 months after RIT-Z. Relapses occurred in both previously and newly involved sites; a significant association was found between the number of pathologic sites involved prior to RIT-Z and subsequent TTNT. Despite the excellent response rate, the duration of response was shorter than the previous one confirming the known trend of relapses to occur earlier after subsequent treatments. Rituximab maintenance after RIT-Z showed encouraging results in terms of prolonging EFS, warranting further studies. Copyright © 2010 John Wiley & Sons, Ltd.
Resumo:
Recently, modern cross-sectional imaging techniques such as multi-detector computed tomography (MDCT) have pioneered post mortem investigations, especially in forensic medicine. Such approaches can also be used to investigate bones non-invasively for anthropological purposes. Long bones are often examined in forensic cases because they are frequently discovered and transferred to medico-legal departments for investigation. To estimate their age, the trabecular structure must be examined. This study aimed to compare the performance of MDCT with conventional X-rays to investigate the trabecular structure of long bones. Fifty-two dry bones (24 humeri and 28 femora) from anthropological collections were first examined by conventional X-ray, and then by MDCT. Trabecular structure was evaluated by seven observers (two experienced and five inexperienced in anthropology) who analyzed images obtained by radiological methods. Analyses contained the measurement of one quantitative parameter (caput diameter of humerus and femur) and staging the trabecular structure of each bone. Preciseness of each technique was indicated by describing areas of trabecular destruction and particularities of the bones, such as pathological changes. Concerning quantitative parameters, the measurements demonstrate comparable results for the MDCT and conventional X-ray techniques. In contrast, the overall inter-observer reliability of the staging was low with MDCT and conventional X-ray. Reliability increased significantly when only the results of the staging performed by the two experienced observers were compared, particularly regarding the MDCT analysis. Our results also indicate that MDCT appears to be better suited to a detailed examination of the trabecular structure. In our opinion, MDCT is an adequate tool with which to examine the trabecular structure of long bones. However, adequate methods should be developed or existing methods should be adapted to MDCT.
Resumo:
We analyzed the initial adhesion and biofilm formation of Staphylococcus aureus (ATCC 29213) and S. epidermidis RP62A (ATCC 35984) on various bone grafts and bone graft substitutes under standardized in vitro conditions. In parallel, microcalorimetry was evaluated as a real-time microbiological assay in the investigation of biofilm formation and material science research. The materials beta-tricalcium phosphate (beta-TCP), processed human spongiosa (Tutoplast) and poly(methyl methacrylate) (PMMA) were investigated and compared with polyethylene (PE). Bacterial counts (log(10) cfu per sample) were highest on beta-TCP (S. aureus 7.67 +/- 0.17; S. epidermidis 8.14 +/- 0.05) while bacterial density (log(10) cfu per surface) was highest on PMMA (S. aureus 6.12 +/- 0.2, S. epidermidis 7.65 +/- 0.13). Detection time for S. aureus biofilms was shorter for the porous materials (beta-TCP and processed human spongiosa, p < 0.001) compared to the smooth materials (PMMA and PE), with no differences between beta-TCP and processed human spongiosa (p > 0.05) or PMMA and PE (p > 0.05). In contrast, for S. epidermidis biofilms the detection time was different (p < 0.001) between all materials except between processed human spongiosa and PE (p > 0.05). The quantitative analysis by quantitative culture after washing and sonication of the material demonstrated the importance of monitoring factors like specific surface or porosity of the test materials. Isothermal microcalorimetry proved to be a suitable tool for an accurate, non-invasive and real-time microbiological assay, allowing the detection of bacterial biomass without removing the biofilm from the surface.
Resumo:
A large variety of techniques have been used to measure soil CO2 released from the soil surface, and much of the variability observed between locations must be attributed to the different methods used by the investigators. Therefore, a minimum protocol of measurement procedures should be established. The objectives of this study were (a) to compare different absorption areas, concentrations and volumes of the alkali trapping solution used in closed static chambers (CSC), and (b) to compare both, the optimized alkali trapping solution and the soda-lime trapping using CSC to measure soil respiration in sugarcane areas. Three CO2 absorption areas were evaluated (7; 15 and 20 % of the soil emission area or chamber); two volumes of NaOH (40 and 80 mL) at three concentrations (0.1, 0.25 and 0.5 mol L-1). Three different types of alkaline traps were tested: (a), 80 mL of 0.5 mol L-1 NaOH in glass containers, absorption area 15 % (V0.5); (b) 40 mL of 2 mol L-1 NaOH retained in a sponge, absorption area 80 % (S2) and (c) 40 g soda lime, absorption area 15 % (SL). NaOH concentrations of 0.5 mol L-1 or lower underestimated the soil CO2-C flux or CO2 flux. The lower limit of the alkali trap absorption area should be a minimum of 20 % of the area covered by the chamber. The 2 mol L-1 NaOH solution trap (S2) was the most efficient (highest accuracy and highest CO2 fluxes) in measuring soil respiration.
Resumo:
Landfill gas emissions are one of the main sources of anthropogenic methane (CH4), a major greenhouse gas. In this paper, an economically attractive alternative to minimize greenhouse gas emissions from municipal solid waste landfills was sought. This alternative consists in special biofilters as landfill covers with oxidative capacity in the presence of CH4. To improve the quality/cost ratio of the project, compost was chosen as one of the cover substrates and soil (Typic red yellow-silt-clay Podzolic) as the other. The performance of four substrates was studied in laboratory experiments: municipal solid waste (MSW) compost, soil, and two soil-compost at different proportions. This study aimed to evaluate the suitability and environmental compatibility as a means of CH4 oxidation in biofilters. Four biofilters were constructed in 60 cm PVC tubes with an internal diameter of 10 cm. Each filter contained 2.3 L of oxidizing substrate at the beginning of the experiment. The gas used was a mixture of CH4 and air introduced at the bottom of each biofilter, at a flow of 150 mL min-1, by a flow meter. One hundred days after the beginning of the experiment, the best biofilter was the MSW compost with an oxidation rate of 990 g m-3 day-1 , corresponding to an efficiency of 44 %. It can be concluded that the four substrates studied have satisfactory oxidative capacity, and the substrates can be used advantageously as cover substrate of MSW landfills.