987 resultados para Extragalactic Distance Scale
Resumo:
The objective of the present study was to evaluate the factor structure of Bech's version of the Brief Psychiatric Rating Scale (BPRS), translated into Portuguese. The BPRS was administered to a heterogeneous group of psychiatric inpatients (N = 98) and outpatients (N = 62) in a University Hospital. Each patient was evaluated from one to eight times. The interval between consecutive interviews was one week for the inpatients and one month for the outpatients. The results were submitted to factorial analysis. The internal consistency of the total scale and of each factor was also estimated. Factorial analysis followed by normalized orthogonal rotation (Varimax) yielded four factors: Withdrawal-Retardation, Thinking Disorder, Anxious-Depression and Activation. Internal consistency measured by Cronbach's alpha coefficient ranged from 0.766 to 0.879. The data show that the factor structure of the present instrument is similar to that of the American version of the BPRS which contains 18 items, except for the absence of the fifth factor of the latter scale, Hostile-Suspiciousness.
Resumo:
The objective of the present study was to evaluate the reliability and clinical utility of a Portuguese version of the Abnormal Involuntary Movements Scale (AIMS). Videotaped interviews with 16 psychiatric inpatients treated with antipsychotic drugs for at least 5 years were evaluated. Reliability was assessed by the intraclass correlation coefficient (ICC) between three raters, two with and one without clinical training in psychopathology. Clinical utility was assessed by the difference between the scores of patients with (N = 11) and without (N = 5) tardive dyskinesia (TD). Patients with TD exhibited a higher severity of global evaluation by the AIMS (sum of scores: 4.2 ± 0.9 vs 0.4 ± 0.2; score on item 8: 2.3 ± 0.3 vs 0.4 ± 0.2, TD vs controls). The ICC for the global evaluation was fair between the two skilled raters (0.58-0.62) and poor between these raters and the rater without clinical experience (0.05-0.29). Thus, we concluded that the Portuguese version of the AIMS shows an acceptable inter-rater reliability, but only between clinically skilled raters, and that it is clinically useful.
Resumo:
The purpose of the present study was to translate and adapt the Berg balance scale, an instrument for functional balance assessment, to Brazilian-Portuguese and to determine the reliability of scores obtained with the Brazilian adaptation. Two persons proficient in English independently translated the original scale into Brazilian-Portuguese and a consensus version was generated. Two translators performed a back translation. Discrepancies were discussed and solved by a panel. Forty patients older than 65 years and 40 therapists were included in the cultural adaptation phase. If more than 15% of therapists or patients reported difficulty in understanding an item, that item was reformulated and reapplied. The final Brazilian version was then tested on 36 elderly patients (over age 65). The average age was 72 years. Reliability of the measure was assessed twice by one physical therapist (1-week interval between assessments) and once by one independent physical therapist. Descriptive analysis was used to characterize the patients. The intraclass correlation coefficient (ICC) and Pearson's correlation coefficient were computed to assess intra- and interobserver reliability. Six questions were modified during the translation stage and cultural adaptation phase. The ICC for intra- and interobserver reliability was 0.99 (P < 0.001) and 0.98 (P < 0.001), respectively. The Pearson correlation coefficient for intra- and interobserver reliability was 0.98 (P < 0.001) and 0.97 (P < 0.001), respectively. We conclude that the Brazilian version of the Berg balance scale is a reliable instrument to be used in balance assessment of elderly Brazilian patients.
Resumo:
We hypothesized that chronic oral administration of the phosphodiesterase-5 inhibitor sildenafil could improve the exercise capacity and pulmonary hemodynamics in patients with pulmonary arterial hypertension (PAH) on the basis of previous short-term studies. We tested this hypothesis in 14 subjects with PAH, including seven patients with the idiopathic form and seven patients with atrial septal defects, but no other congenital heart abnormalities. Patients were subjected to a 6-min walk test and dyspnea was graded according to the Borg scale. Pulmonary flow and pressures were measured by Doppler echocardiography. Patients were given sildenafil, 75 mg orally three times a day, and followed up for 1 year. Sildenafil therapy resulted in the following changes: increase in the 6-min walk distance from a median value of 387 m (range 0 to 484 m) to 462 m (range 408 to 588 m; P < 0.01), improvement of the Borg dyspnea score from 4.0 (median value) to 3.0 (P < 0.01), and increased pulmonary flow (velocity-time integral) from a median value of 0.12 (range 0.08 to 0.25) to 0.23 (range 0.11 to 0.40; P < 0.01) with no changes in pulmonary pressures. In one patient with pulmonary veno-occlusive disease diagnosed by a lung biopsy, sildenafil had a better effect on the pulmonary wedge pressure than inhaled nitric oxide (15 and 29 mmHg, respectively, acute test). He walked 112 m at baseline and 408 m at one year. One patient died at 11 months of treatment. No other relevant events occurred. Thus, chronic administration of sildenafil improves the physical capacity of PAH patients and may be beneficial in selected cases of veno-occlusive disease.
Resumo:
The reliability and validity of a Portuguese version of the Young Mania Rating Scale were evaluated. The original scale was translated into and adapted to Portuguese by the authors. Definitions of clinical manifestations, a semi-structured anchored interview and more explicit rating criteria were added to the scale. Fifty-five adult subjects, aged 18 to 60 years, with a diagnosis of Current Manic Episode according to DSM-III-R criteria were assessed using the Young Mania Rating Scale as well as the Brief Psychiatric Rating Scale in two sessions held at intervals from 7 to 10 days. Good reliability ratings were obtained, with intra-class correlation coefficient of 0.97 for total scores, and levels of agreement above 0.80 (P < 0.001) for all individual items. Internal consistency analysis resulted in an alpha = 0.67 for the scale as a whole, and an alpha = 0.72 for each standardized item (P < 0.001). For the concurrent validity, a correlation of 0.78 was obtained by the Pearson coefficient between the total scores of the Young Mania Rating Scale and Brief Psychiatric Rating Scale. The results are similar to those reported for the English version, indicating that the Portuguese version of the scale constitutes a reliable and valid instrument for the assessment of manic patients.
Resumo:
The global interest towards renewable energy production such as wind and solar energy is increasing, which in turn calls for new energy storage concepts due to the larger share of intermittent energy production. Power-to-gas solutions can be utilized to convert surplus electricity to chemical energy which can be stored for extended periods of time. The energy storage concept explored in this thesis is an integrated energy storage tank connected to an oxy-fuel combustion plant. Using this approach, flue gases from the plant could be fed directly into the storage tank and later converted into synthetic natural gas by utilizing electrolysis-methanation route. This work utilizes computational fluid dynamics to model the desublimation of carbon dioxide inside a storage tank containing cryogenic liquid, such as liquefied natural gas. Numerical modelling enables the evaluation of the transient flow patterns caused by the desublimation, as well as general fluid behaviour inside the tank. Based on simulations the stability of the cryogenic storage and the magnitude of the key parameters can be evaluated.
Resumo:
The objective of the present study was to determine if there is a health-related quality of life (HRQL) instrument, generic or specific, that better represents functional capacity dysfunction in idiopathic pulmonary fibrosis (IPF) patients. HRQL was evaluated in 20 IPF patients using generic and specific questionnaires (Medical Outcomes Short Form 36 (SF-36) and Saint George's Respiratory Questionnaire (SGRQ), respectively). Functional status was evaluated by pulmonary function tests, 6-min walking distance test (6MWDT) and dyspnea indexes (baseline dyspnea index) at rest and after exercise (modified Borg scale). There was a restrictive pattern with impairment of diffusion capacity (total lung capacity, TLC = 71.5 ± 15.6%, forced vital capacity = 70.4 ± 19.4%, and carbon monoxide diffusing capacity = 41.5 ± 16.2% of predicted value), a reduction in exercise capacity (6MWDT = 435.6 ± 95.5 m) and an increase of perceived dyspnea score at rest and during exercise (6 ± 2.5 and 7.1 ± 1.3, respectively). Both questionnaires presented correlation with some functional parameters (TLC, forced expiratory volume in 1 s and carbon monoxide diffusing capacity) and the best correlation was with TLC. Almost all of the SGRQ domains presented a strong correlation with functional status, while in SF-36 only physical function and vitality presented a good correlation with functional status. Dyspnea index at rest and 6MWDT also presented a good correlation with HRQL. Our results suggest that a specific instead of a generic questionnaire is a more appropriate instrument for HRQL evaluation in IPF patients and that TLC is the functional parameter showing best correlation with HRQL.
Resumo:
This work focuses on the 159.5 kW solar photovoltaic power plant project installed at the Lappeenranta University of Technology in 2013 as an example of what a solar plant project could be in Finland. The project consists of a two row carport and a flat roof installation on the roof of the university laboratories. The purpose of this project is not only its obvious energy savings potential but also to serve as research and teaching laboratory tool. By 2013, there were not many large scale solar power plants in Finland. For this reason, the installation and data experience from the solar power plant at LUT has brought valuable information for similar projects in northern countries. This work includes a first part for the design and acquisition of the project to continue explaining about the components and their installation. At the end, energy produced by this solar power plant is studied and calculated to find out some relevant economical results. For this, the radiation arriving to southern Finland, the losses of the system in cold weather and the impact of snow among other aspects are taken into account.
Successful scale-up of human embryonic stem cell production in a stirred microcarrier culture system
Resumo:
Future clinical applications of human embryonic stem (hES) cells will require high-yield culture protocols. Currently, hES cells are mainly cultured in static tissue plates, which offer a limited surface and require repeated sub-culturing. Here we describe a stirred system with commercial dextran-based microcarriers coated with denatured collagen to scale-up hES cell production. Maintenance of pluripotency in the microcarrier-based stirred system was shown by immunocytochemical and flow cytometry analyses for pluripotency-associated markers. The formation of cavitated embryoid bodies expressing markers of endoderm, ectoderm and mesoderm was further evidence of maintenance of differentiation capability. Cell yield per volume of medium spent was more than 2-fold higher than in static plates, resulting in a significant decrease in cultivation costs. A total of 10(8) karyotypically stable hES cells were obtained from a unitary small vessel that needed virtually no manipulation during cell proliferation, decreasing risks of contamination. Spinner flasks are available up to working volumes in the range of several liters. If desired, samples from the homogenous suspension can be withdrawn to allow process validation needed in the last expansion steps prior to transplantation. Especially when thinking about clinical trials involving from dozens to hundreds of patients, the use of a small number of larger spinners instead of hundreds of plates or flasks will be beneficial. To our knowledge, this is the first description of successful scale-up of feeder- and Matrigel™-free production of undifferentiated hES cells under continuous agitation, which makes this system a promising alternative for both therapy and research needs.
Resumo:
We assessed the 6-min walk distance (6MWD) and body weight x distance product (6MWw) in healthy Brazilian subjects and compared measured 6MWD with values predicted in five reference equations developed for other populations. Anthropometry, spirometry, reported physical activity, and two walk tests in a 30-m corridor were evaluated in 134 subjects (73 females, 13-84 years). Mean 6MWD and 6MWw were significantly greater in males than in females (622 ± 80 m, 46,322 ± 10,539 kg.m vs 551 ± 71 m, 36,356 ± 8,289 kg.m, P < 0.05). Four equations significantly overestimated measured 6MWD (range, 32 ± 71 to 137 ± 74 m; P < 0.001), and one significantly underestimated it (-36 ± 86 m; P < 0.001). 6MWD significantly correlated with age (r = -0.39), height (r = 0.44), body mass index (r = -0.24), and reported physical activity (r = 0.25). 6MWw significantly correlated with age (r = -0.21), height (r = 0.66) and reported physical activity (r = 0.25). The reference equation devised for walk distance was 6MWDm = 622.461 - (1.846 x Ageyears) + (61.503 x Gendermales = 1; females = 0); r2 = 0.300. In an additional group of 85 subjects prospectively studied, the difference between measured and the 6MWD predicted with the equation proposed here was not significant (-3 ± 68 m; P = 0.938). The measured 6MWD represented 99.6 ± 11.9% of the predicted value. We conclude that 6MWD and 6MWw variances were adequately explained by demographic and anthropometric attributes. This reference equation is probably most appropriate for evaluating the exercise capacity of Brazilian patients with chronic diseases.
Resumo:
Few studies show patient outcomes over time in chronic obstructive pulmonary disease (COPD). In the present study, we monitored forced expiratory volume in the first second (FEV1) and other manifestations of the disease over 3 years in 133 COPD patients (69% males, age = 65 ± 9 years, FEV1 = 59 ± 25%) evaluated at baseline. During follow-up, 15 patients (11%) died and 23 (17%) dropped out. Measurements for 95 (72%) COPD patients alive after 3 years were analyzed. FEV1, body mass index (BMI), 6-min walking distance (6MWD), Medical Research Council scale (MRC), Saint Georges Respiratory Questionnaire (SGRQ), Charlson Comorbidity index, and BODE index were obtained at baseline and after 3 years. At baseline, 17 patients (18%) presented mild, 39% moderate, 19% severe, and 24% very severe COPD. Predicted FEV1 % and BMI did not change over the period (P > 0.05). FEV1 in liters [1.25 (0.96-1.72) vs 1.26 (0.88-1.60) L; P < 0.001], 6MWD (438 ± 86 vs 412 ± 100 m; P < 0.001), MRC [1 (1-2) vs 2 (1-3); P = 0.002], Charlson index [3 (3-4) vs4 (3-5); P = 0.009], BODE index (2.2 ± 1.8 vs 2.6 ± 2.3; P = 0.008), and total SGRQ (42 ± 19 vs 44 ± 19%; P = 0.041) worsened after 3 years compared to baseline measurements. These data show that COPD patients deteriorated during the 3-year follow-up despite the fact that they had only minor modifications in airway obstruction and body composition. They support the need for comprehensive patient assessment to better identify disease progression.
Severity score system for progressive myelopathy: development and validation of a new clinical scale
Resumo:
Progressive myelopathies can be secondary to inborn errors of metabolism (IEM) such as mucopolysaccharidosis, mucolipidosis, and adrenomyeloneuropathy. The available scale, Japanese Orthopaedic Association (JOA) score, was validated only for degenerative vertebral diseases. Our objective is to propose and validate a new scale addressing progressive myelopathies and to present validating data for JOA in these diseases. A new scale, Severity Score System for Progressive Myelopathy (SSPROM), covering motor disability, sphincter dysfunction, spasticity, and sensory losses. Inter- and intra-rater reliabilities were measured. External validation was tested by applying JOA, the Expanded Disability Status Scale (EDSS), the Barthel index, and the Osame Motor Disability Score. Thirty-eight patients, 17 with adrenomyeloneuropathy, 3 with mucopolysaccharidosis I, 3 with mucopolysaccharidosis IV, 2 with mucopolysaccharidosis VI, 2 with mucolipidosis, and 11 with human T-cell lymphotropic virus type-1 (HTLV-1)-associated myelopathy participated in the study. The mean ± SD SSPROM and JOA scores were 74.6 ± 11.4 and 12.4 ± 2.3, respectively. Construct validity for SSPROM (JOA: r = 0.84, P < 0.0001; EDSS: r = -0.83, P < 0.0001; Barthel: r = 0.56, P < 0.002; Osame: r = -0.94, P < 0.0001) and reliability (intra-rater: r = 0.83, P < 0.0001; inter-rater: r = 0.94, P < 0.0001) were demonstrated. The metric properties of JOA were similar to those found in SSPROM. Several clinimetric requirements were met for both SSPROM and JOA scales. Since SSPROM has a wider range, it should be useful for follow-up studies on IEM myelopathies.
Resumo:
This study reviewed the use of the Strengths and Weaknesses of Attention-Deficit/Hyperactivity-symptoms and Normal-behaviors (SWAN) rating scale in diagnostic and evolutive approaches to attention deficit hyperactivity disorder (ADHD) and in correlational studies of the disorder. A review of articles published in indexed journals from electronic databases was conducted and 61 articles on the SWAN scale were analyzed. From these, 27 were selected to a) examine use of SWAN in research on attention disorders and b) verify evidence of its usefulness in the areas of genetics, neuropsychology, diagnostics, psychiatric comorbidities, neuroimaging, pharmacotherapy, and to examine its statistical reliability and validity in studies of diverse populations. This review of articles indicated a growing use of the SWAN scale for diagnostic purposes, for therapy, and in research on areas other than ADHD, especially when compared with other reliable scales. Use of the scale in ADHD diagnosis requires further statistical testing to define its psychometric properties.