948 resultados para Experimental Low Back Pain
Resumo:
Applications involving biosignals, such as Electrocardiography (ECG), are becoming more pervasive with the extension towards non-intrusive scenarios helping targeting ambulatory healthcare monitoring, emotion assessment, among many others. In this study we introduce a new type of silver/silver chloride (Ag/AgCl) electrodes based on a paper substrate and produced using an inkjet printing technique. This type of electrodes can increase the potential applications of biosignal acquisition technologies for everyday life use, given that there are several advantages, such as cost reduction and easier recycling, resultant from the approach explored in our work. We performed a comparison study to assess the quality of this new electrode type, in which ECG data was collected with three types of Ag/AgCl electrodes: i) gelled; ii) dry iii) paper-based inkjet printed. We also compared the performance of each electrode when acquired using a professional-grade gold standard device, and a low cost platform. Experimental results showed that data acquired using our proposed inkjet printed electrode is highly correlated with data obtained through conventional electrodes. Moreover, the electrodes are robust to high-end and low-end data acquisition devices. Copyright © 2014 SCITEPRESS - Science and Technology Publications. All rights reserved.
Resumo:
Visible range to telecom band spectral translation is accomplished using an amorphous SiC pi'n/pin wavelength selector under appropriate front and back optical light bias. Results show that background intensity works as selectors in the infrared region, shifting the sensor sensitivity. Low intensities select the near-infrared range while high intensities select the visible part according to its wavelength. Here, the optical gain is very high in the infrared/red range, decreases in the green range, stays close to one in the blue region and strongly decreases in the near-UV range. The transfer characteristics effects due to changes in steady state light intensity and wavelength backgrounds are presented. The relationship between the optical inputs and the output signal is established. A capacitive optoelectronic model is presented and tested using the experimental results. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Resumo:
The reduction of the power loss generated in mechanical transmissions and the use of low friction biodegradable lubricants has been attracting considerable attention in recent times. Therefore, it is necessary to develop methods to test and evaluate the performance of such lubricants and compare them with conventional ones. In this sense, a Four-Ball Machine was modified allowing the test of rolling bearings. A 51107 thrust ball bearing was used to test two different greases and the corresponding base oils. Friction torque and operating temperatures were continuously monitored to quantify the power loss and the heat evacuation for each lubricant tested. Copyright © 2010 John Wiley & Sons, Ltd.
Resumo:
Objective: Summarize all relevant findings in published literature regarding the potential dose reduction related to image quality using Sinogram-Affirmed Iterative Reconstruction (SAFIRE) compared to Filtered Back Projection (FBP). Background: Computed Tomography (CT) is one of the most used radiographic modalities in clinical practice providing high spatial and contrast resolution. However it also delivers a relatively high radiation dose to the patient. Reconstructing raw-data using Iterative Reconstruction (IR) algorithms has the potential to iteratively reduce image noise while maintaining or improving image quality of low dose standard FBP reconstructions. Nevertheless, long reconstruction times made IR unpractical for clinical use until recently. Siemens Medical developed a new IR algorithm called SAFIRE, which uses up to 5 different strength levels, and poses an alternative to the conventional IR with a significant reconstruction time reduction. Methods: MEDLINE, ScienceDirect and CINAHL databases were used for gathering literature. Eleven articles were included in this review (from 2012 to July 2014). Discussion: This narrative review summarizes the results of eleven articles (using studies on both patients and phantoms) and describes SAFIRE strengths for noise reduction in low dose acquisitions while providing acceptable image quality. Conclusion: Even though the results differ slightly, the literature gathered for this review suggests that the dose in current CT protocols can be reduced at least 50% while maintaining or improving image quality. There is however a lack of literature concerning paediatric population (with increased radiation sensitivity). Further studies should also assess the impact of SAFIRE on diagnostic accuracy.
Resumo:
Introduction: Pressure ulcers are a high cost, high volume issue for health and medical care providers, affecting patients’ recovery and psychological wellbeing. The current research of support surfaces on pressure as a risk factor in the development of pressure ulcers is not relevant to the specialised, controlled environment of the radiological setting. Method: 38 healthy participants aged 19-51 were placed supine on two different imaging surfaces. The XSENSOR pressure mapping system was used to measure the interface pressure. Data was acquired over a time of 20 minutes preceded by 6 minutes settling time to reduce measurement error. Qualitative information regarding participants’ opinion on pain and comfort was recorded using a questionnaire. Data analysis was performed using SPSS 22. Results: Data was collected from 30 participants aged 19 to 51 (mean 25.77, SD 7.72), BMI from 18.7 to 33.6 (mean 24.12, SD 3.29), for two surfaces, following eight participant exclusions due to technical faults. Total average pressure, average pressure for jeopardy areas (head, sacrum & heels) and peak pressure for jeopardy areas were calculated as interface pressure in mmHg. Qualitative data showed that a significant difference in experiences of comfort and pain was found in the jeopardy areas (P<0.05) between the two surfaces. Conclusion: A significant difference is seen in average pressure between the two surfaces. Pain and comfort data also show a significant difference between the surfaces, both findings support the proposal for further investigation into the effects of radiological surfaces as a risk factor for the formation of pressure ulcers.
Resumo:
Current Electrocardiographic (ECG) signal acquisition methods are generally highly intrusive, as they involve the use of pre-gelled electrodes and cabled sensors placed directly on the person, at the chest or limbs level. Moreover, systems that make use of alternative conductive materials to overcome this issue, only provide heart rate information and not the detailed signal itself. We present a comparison and evaluation of two types of dry electrodes as interface with the skin, targeting wearable and low intrusiveness applications, which enable ECG measurement without the need for any apparatus permanently fitted to the individual. In particular, our approach is targeted at ECG biometrics using signals collected at the hand or finger level. A custom differential circuit with virtual ground was also developed for enhanced usability. Our work builds upon the current stateof-the-art in sensoring devices and processing tools, and enables novel data acquisition settings through the use of dry electrodes. Experimental evaluation was performed for Ag/AgCl and Electrolycra materials, and results show that both materials exhibit adequate performance for the intended application.
Resumo:
In this work we study the electro-rheological behaviour of a series of four liquid crystal (LC) cyanobiphenyls with a number of carbon atoms in the alkyl group, ranging from five to eight (5CB–8CB). We present the flow curves for different temperatures and under the influence of an external electric field, ranging from 0 to 3 kV/mm, and the viscosity as a function of the temperature, for the same values of electric field, obtained for different shear rates. Theoretical interpretation of the observed behaviours is proposed in the framework of the continuum theory of Leslie–Ericksen for low molecular weight nematic LCs. In our analysis, the director alignment angle is only a function of the ratio between the shear rate and the square of the electric field – boundary conditions are neglected. By fitting the theoretical model to the experimental data, we are able to determine some viscosity coefficients and the dielectric anisotropy as a function of temperature. To interpret the behaviour of the flow curves near the nematic–isotropic transitions, we apply the continuum theory of Olmsted–Goldbart, which extends the theory of Leslie–Ericksen to the case where the degree of alignment of the LC molecules can also vary.
Resumo:
The objective of this work was to study the influence of the boundary conditions on low-velocity impact behaviour of carbon-epoxy composite plates. Experimental work and numerical analysis were performed on [04,904]s laminates. The influence of different boundary conditions on the impacted plates was analysed considering rectangular and square plates. The X-radiography was used as a non-destructive technique to evaluate the internal damage caused by impact loading. A three-dimensional numerical analysis was also performed considering progressive damage modelling. The model includes three-dimensional solid elements and interface finite elements including a cohesive mixed-mode damage model, which allows simulating delamination between different oriented layers. It was verified that plate’s boundary conditions have influence on the delaminated area. Good agreement between experimental and numerical analysis for shape, orientation and size of the delamination was obtained.
Resumo:
In the western part of the State of Bahia Biomphalaria straminea and B. glabrata both occur, but in the majority of cases they do not share the same habitat. In the State of Ceará, however, B. straminea is the sole snail host of Schistosoma mansoni. In this survey, no naturally infected B. straminea was found among snails collected from Bahia and Ceará, evidently because of the very low infection rates. The susceptibility of laboratory-reared specimens to infection with a Puerto Rican strain of S. mansoni was then tested experimentally. In general, the snails showed very low susceptibility. The infection rates were 1.1% among snails from Redenção (Ceará); 2.3% in those from Pentecoste (Ceará); 2.9% in snails from São Desidério (Bahia), while they were very high among an albino strain (NIH) of B. glabrata used as control. Another group of B. straminea from São Desidério was exposed to a Bahian strain of S. mansoni and the infection rate was still very low (3.6%) Apparently, the very low susceptibility of B. straminea, despite high snail density, is correlated with moderate infection rates with S. mansoni among humans, as shown by the results of stool examinations conducted by SUCAM in the municipalities of Redenção and Pentecoste, in Ceará.
Resumo:
Coral snakes, the New World Elapidae, are included in the genera Micniroides and Micrurus. The genus Mlcrurus comprises nearly all coral snake species and those which are responsible for human snake-bite accidents. The following generalizations concerning the effects induced by their venoms, and their venom-properties can be made. Coral snake venoms are neurotoxic, producing loss of muscle strenght and death by respiratory paralysis. Local edema and necrosis are not induced nor blood coagulation or hemorrhages. Proteolysis activity is absent or of very low grade. They display phospholipase A2 activity. Nephrotoxic effects are not evoked. The main toxins from elapid venoms are postsynaptic and presynaptic neurotoxins and cardiotoxins. Phospholipases A2 endowed with myonecrotic or cardiotoxin-like properties are important toxic components from some elapid venoms. The mode of action of Micrurus frontalis, M. lemniscatus, M. corallinus and M. fulvius venoms has been investigated in isolated muscle preparations and is here discussed. It is shown that while M. frontalis and M. lemniscatus venoms must contain only neurotoxins that act at the cholinergic end-plate receptor (postsynaptic neurotoxins), M. corallinus venom also inhibits evoked acetylcholine release by the motor nerve endings (presynaptic neurotoxin-like effect) and M. fulvius induces muscle fiber membrane depolarization (cardiotoxin-like effect). The effects produced by M. corallinus and M. fulvius venoms in vivo in dogs and M. frontalis venom in dogs and monkeys are also reported.
Resumo:
Buildings account for 40% of total energy consumption in the European Union. The reduction of energy consumption in the buildings sector constitute an important measure needed to reduce the Union's energy dependency and greenhouse gas emissions. The Portuguese legislation incorporate this principles in order to regulate the energy performance of buildings. This energy performance should be accompanied by good conditions for the occupants of the buildings. According to EN 15251 (2007) the four factors that affect the occupant comfort in the buildings are: Indoor Air Quality (IAQ), thermal comfort, acoustics and lighting. Ventilation directly affects all except the lighting, so it is crucial to understand the performance of it. The ventilation efficiency concept therefore earn significance, because it is an attempt to quantify a parameter that can easily distinguish the different options for air diffusion in the spaces. The two indicators most internationally accepted are the Air Change Efficiency (ACE) and the Contaminant Removal Effectiveness (CRE). Nowadays with the developed of the Computational Fluid Dynamics (CFD) the behaviour of ventilation can be more easily predicted. Thirteen strategies of air diffusion were measured in a test chamber through the application of the tracer gas method, with the objective to validate the calculation by the MicroFlo module of the IES-VE software for this two indicators. The main conclusions from this work were: that the values of the numerical simulations are in agreement with experimental measurements; the value of the CRE is more dependent of the position of the contamination source, that the strategy used for the air diffusion; the ACE indicator is more appropriate for quantifying the quality of the air diffusion; the solutions to be adopted, to maximize the ventilation efficiency should be, the schemes that operate with low speeds of supply air and small differences between supply air temperature and the room temperature.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Hand-off (or hand-over), the process where mobile nodes select the best access point available to transfer data, has been well studied in wireless networks. The performance of a hand-off process depends on the specific characteristics of the wireless links. In the case of low-power wireless networks, hand-off decisions must be carefully taken by considering the unique properties of inexpensive low-power radios. This paper addresses the design, implementation and evaluation of smart-HOP, a hand-off mechanism tailored for low-power wireless networks. This work has three main contributions. First, it formulates the hard hand-off process for low-power networks (such as typical wireless sensor networks - WSNs) with a probabilistic model, to investigate the impact of the most relevant channel parameters through an analytical approach. Second, it confirms the probabilistic model through simulation and further elaborates on the impact of several hand-off parameters. Third, it fine-tunes the most relevant hand-off parameters via an extended set of experiments, in a realistic experimental scenario. The evaluation shows that smart-HOP performs well in the transitional region while achieving more than 98 percent relative delivery ratio and hand-off delays in the order of a few tens of a milliseconds.
Resumo:
This paper aims to study the best way to express the parasitemia of Trypanosoma cruzi's experimentally infected animals. Individual scores may have a great variability, not emphasized by the majority of the authors. A group of 50 rats infected with 1x10(6) trypomastigotes of T. cruzi Y strain was used and the parasitemia was estimated by BRENER' s method. The results showed that the median can avoid false results due to very high or low parasitemias but it does not have the mathematic properties necessary for analysis of variance. The comparison of the means of the original and transformed data, with their respective coefficients of variability (CV), showed that the logarithmic mean (Mlog) have the minor value of CV. Therefore, the Mlog is the best way to express the parasitemia when the data show great variability. The number of the animal for group did not affect the variability of data when the Mlog and CV were used.
Resumo:
Experimental optoelectronic characterization of a p-i'(a-SiC:H)-n/pi(a-Si:H)-n heterostructure with low conductivity doped layers shows the feasibility of tailoring channel bandwidth and wavelength by optical bias through back and front side illumination. Front background enhances light-to-dark sensitivity of the long and medium wavelength range, and strongly quenches the others. Back violet background enhances the magnitude in short wavelength range and reduces the others. Experiments have three distinct programmed time slots: control, hibernation and data. Throughout the control time slot steady light wavelengths illuminate either or both sides of the device, followed by the hibernation without any background illumination. The third time slot allows a programmable sequence of different wavelengths with an impulse frequency of 6000Hz to shine upon the sensor. Results show that the control time slot illumination has an influence on the data time slot which is used as a volatile memory with the set, reset logical functions. © IFIP International Federation for Information Processing 2015.