987 resultados para Error detection
Resumo:
The objective of this study was to describe the circulation of caliciviruses in the West Central region of Brazil and its correlation with children's gender and age, as well as with the year and months of the sample collection. Reverse transcriptase-polymerase chain reaction was performed to detect the human calicivirus genome in 1006 fecal samples that were collected in Goiânia (n = 696) and Brasília (n = 310). Viral RNA was detected in 8.6% of the samples. No significant difference in viral prevalence was found regarding gender, age or year of the sample. However, it was observed that in Goiânia, there is a higher incidence of caliciviruses from September to March. The analysis employing three primer pairs demonstrated that the Ni/E3 or JV12/13 primer pairs, which detect norovirus (NoV), detected 41 positive samples while the 289/290 primer pair, which detects NoV or sapovirus, detected the remaining 46 samples. Calicivirus circulates in the West Central region of Brazil and for better detection of this virus it is important to use more than one primer pair. Also, we conclude that the seasonality presented by this virus is related to higher humidity in the period.
Resumo:
Immediate prevention of meningococcal disease relies in part on the prompt treatment with antibiotics of household and other close contacts of cases; however intervention with effective vaccination relies on identification of serogroup-causing strains. Parenteral antibiotic for patient with suspected meningococcal disease before hospital admission is currently recommended. Laboratory standard methods are hindered by failure to detect bacteria by this medical approach to improve patient prognosis. We assessed two polymerase chain reaction (PCR) assays to detect (crgA) and define the serogroups (siaD, orf-2, and ctrA) of Neisseria meningitidis in 120 cerebrospinal fluid (CSF) samples from positive cases (culture or antigen detection or direct smear). The PCR sensitivity for the identification of N. meningitidis was 100% (95% confidence interval, CI, 96-100%) compared to a sensitivity of 46% for culture (95% CI 37-55%), 61% for latex agglutination test (95% CI 52-70%), and 68% for Gram stain (95% CI 59-76%); PCR specificity was 97% (95% CI 82-100%). PCR correctly identified the serogroups A, B, C, W135, Y, and X in CSF samples with a sensitivity of 88% (95% CI 80-93%); the primer sets were 100% specific. The introduction of PCR-based assays shall increase laboratory confirmed cases, consequently enhancing surveillance of meningococcal disease.
Resumo:
Strains of enterotoxigenic Escherichia coli (ETEC) are responsible for significant rates of morbidity and mortality among children, particularly in developing countries. The majority of clinical and public health laboratories are capable of isolating and identifying Salmonella, Shigella, Campylobacter, and Escherichia coli O157:H7 from stool samples, but ETEC cannot be identified by routine methods. The method most often used to identify ETEC is polymerase chain reaction for heat-stable and heat-labile enterotoxin genes, and subsequent serotyping, but most clinical and public health laboratories do not have the capacity or resources to perform these tests. In this study, polyclonal rabbit and monoclonal mouse IgG2b antibodies against ETEC heat-labile toxin-I (LT) were characterized and the potential applicability of a capture assay was analyzed. IgG-enriched fractions from rabbit polyclonal and the IgG2b monoclonal antibodies recognized LT in a conformational shape and they were excellent tools for detection of LT-producing strains. These findings indicate that the capture immunoassay could be used as a diagnostic assay of ETEC LT-producing strains in routine diagnosis and in epidemiological studies of diarrhea in developing countries as enzyme linked immunosorbent assay techniques remain as effective and economical choice for the detection of specific pathogen antigens in cultures.
Resumo:
The detection of specific DNA sequences by polymerase chain reaction (PCR) has proved extremely valuable for the analysis of genetic disorders and the diagnosis of a variety of infectious disease pathogens. However, the application to the detection of Schistosoma mansoni is rare, despite a recommendation of the World Health Organization that a major focus of research on schistosomiasis should be on the development and evaluation of new strategies and tools for control of the disease. In this context, a few studies were published for the detection of the parasite in snails, monitoring of cercariae in water bodies, and diagnosis of human infection. The present minireview describes sensitive and specific PCR based systems to detect S. mansoni, indicating possible applications in the detection of snail infection, monitoring of transmission sites, and diagnosis of human infection.
Resumo:
The MRSA-Screen test (Denka Seiken Co., Ltd., Tokyo, Japan), consisting of a slide latex agglutination kit that detects PBP 2a with a monoclonal antibody, was blindly compared to the oxacillin disk diffusion test, the oxacillin-salt agar screen, and PCR of the mecA gene for the detection of methicillin resistance in Staphylococcus aureus. A total of 120 methicillin-susceptible S. aureus (MSSA) and 80 methicillin-resistant S. aureus (MRSA) isolates, defined by the absence or presence of the mecA gene, respectively, were tested. The MRSA-Screen test, the oxacillin disk diffusion test, and the oxacillin-salt agar screening test showed sensitivities of 100, 61.3, and 82.5% and specificities of 99.2, 96.7, and 98.3%, respectively. We conclude that the MRSA-Screen is a very accurate, reliable, and fast test (15 min) for differentiation of MRSA from MSSA colonies on agar plates.
Resumo:
Detection of Onchocerca volvulus in Simulium populations is of primary importance in the assessment of the effectiveness of onchocerciasis control programs. In Brazil, the main focus of onchocerciasis is in the Amazon region, in a Yanomami reserve. The main onchocerciasis control strategy in Brazil is the semi-annually mass distribution of the microfilaricide ivermectin. In accordance with the control strategy for the disease, polymerase chain reaction (PCR) was applied in pools of simuliids from the area to detect the helminth infection in the vectors, as recommended by the Onchocerciasis Elimination Program for the Americas and the World Health Organization. Systematic sampling was performed monthly from September 1998 to October 1999, and a total of 4942 blackflies were collected from two sites (2576 from Balawaú and 2366 from Toototobi). The molecular methodology was found to be highly sensitive and specific for the detection of infected and/or infective blackflies in pools of 50 blackflies. The results from the material collected under field conditions showed that after the sixth cycle of distribution of ivermectin, the prevalence of infected blackflies with O. volvulus had decreased from 8.6 to 0.3% in Balawaú and from 4 to 0.1% in Toototobi.
Resumo:
This study describes the genetic relationships of the first human astrovirus type-8 (HAstV-8) detected in Belém-Brazil, during a public hospital-based study. This strain was compared with other HAstV-8 strains identified elsewhere which have sequences available at GeneBank. The regions ORF1a (primers Mon348/Mon340) and ORF2 (primers Mon269/Mon270) were analyzed by nucleotide sequencing and a high similarity rate was observed among the Belém strain and other HAstV-8 strains. In ORF1a, homology values of 93-100% were detected, and in ORF2 96-99%. Considering the sequence variation (7%) observed in ORF2 region, it was suggested that HAstV-8 strains could be divided in three different lineages.
Resumo:
The misuse of human growth hormone (hGH) in sport is deemed to be unethical and dangerous because of various adverse effects. Thus, it has been added to the International Olympic Committee list of banned substances. Until now, the very low concentration of hGH in the urine made its measurement difficult using classical methodology. Indeed, for routine diagnosis, only plasma measurements were available. However, unlike blood samples, urine is generally provided in abundant quantities and is, at present, the only body fluid allowed to be analysed in sport doping controls. A recently developed enzyme-linked immunosorbent assay (Norditest) makes it now possible, without any extraction, to measure urinary hGH (u-hGH) in a dynamic range of 2-50 ng hGH/l. In our protocol, untreated and treated non-athlete volunteers were followed. Some of them received therapeutical doses of recombinant hGH (Norditropin) for one week either intramuscularly (three increasing doses) or subcutaneously (12 i.u. every day). The u-hGH excretion after treatment showed dramatic increases of 50-100 times the basal values and returned to almost the mean normal level after 24 h. u-hGH was also measured in samples provided by the anti-doping controls at major and minor competitions. Depending on the type of efforts made during the competition, the hGH concentration in urine was dramatically increased. Insulin-like growth factor binding proteins and beta 2-microglobulins in urine and/or in blood could be necessary for the correct investigation of any hGH doping test procedure.
Resumo:
Coagulase-negative Staphylococcus spp. was considered nonpathogenic until the emergence of multiresistance and the demonstration of their participation as infectious agents. In Brazil, oxacillin resistance may be present in over 80% of isolates, and the Clinical and Laboratory Standards Institute standardized a disk-diffusion method to predict this resistance in Staphylococcus. The aim of this study was to evaluate the variability among commercial disks of oxacillin (1 µg) and cefoxitin (30 µg) widely used in clinical laboratories of microbiology, compared with mecA gene and minimum inhibitory concentration (MIC) of oxacillin. The use of oxacillin and cefoxitin disks simultaneously allowed the detection of important differences, particularly, in less frequent species such as S. cohnii, S. haemolyticus, S. saprophyticus, and S. sciuri. Disks of cefoxitin of the brand 2 displayed good correlation with the mecA gene (98.7%) and oxacillin MIC (97.8%), while major discrepancies were observed using disks of brand 1. One of the critical points in the diffusion disk test is the quality of the disks: the use of better quality disks associated with molecular methods lead to better results to define the best antibiotic therapy.
Resumo:
Seven swine were experimentally infected with Taenia solium eggs and blood samples from each animal were periodically collected. At the end of the experiment (t140) the animals did not show clinical aspects of cysticercosis or parasites in tongue inspection. All animals were slaughtered and cut into thin slices in searching for cysts. The number of cysts found in each animal varied from 1 to 85. Enzyme-linked immunosorbent assay (ELISA) tests for antibody (Ab) detection and for antigen (Ag) detection were performed, which presented respectively 71 and 57% of positivity. By immunoblot (IB), using 18/14(T. crassiceps Ag) or lentil-lectin-purified glycoproteins from T. solium Ag (LLGP) as Ag, five (71%) and six (86%) animals were positive, respectively. The association between Ag-ELISA with any IB (18/14 or LLGP) allowed the detection of all animals at 140 days post-experimental infection (days p.e.i.). The use of IB 18/14 combined to the Ag-ELISA allowed the detection of all animals since 70 days p.e.i., and the association between IB LLGP and Ag-ELISA allowed the detection of all animals since 112 days p.e.i. While all animals could be considered healthy by conventional screening tests, the use of immunoassays for detecting Ab and Ag showed better accuracy; therefore it would be more useful than usual clinical examination for screening cysticercosis in slightly infected pigs.
Resumo:
We identified different diarrheagenic (DEC) Escherichia coli pathotypes isolated from 1,207 children with and without acute endemic diarrhea in Salvador, Bahia, Brazil collected as part of a case-control study. Since the identification of DEC cannot be based on only biochemical and culture criteria, we used a multiplex polymerase chain reaction developed by combining five specific primer pairs for Enteropathogenic Escherichia coli (EPEC), Shiga toxin-producing E. coli/ Enterohaemorrhagic E. coli (STEC/EHEC), Enterotoxigenic E. coli (ETEC) and Enteroaggregative E. coli (EAEC) to detect these pathotypes simultaneously in a single-step reaction. In order to distinguish typical and atypical EPEC strains, these were tested for the presence of EAF plasmid. The prevalence of diarrheagenic E. coli in this sample of a global case-control study was 25.4% (259 patients) and 18.7% (35 patients) in the diarrhea group (1,020 patients) and the control group (187 patients), respectively. The most frequently isolated pathotype was EAEC (10.7%), followed by atypical EPEC (9.4%), ETEC (3.7%), and STEC (0.6%). Typical EPEC was detected only in one sample. The prevalence of the pathotypes studied in children with diarrhea was not significantly different from that in children without diarrhea.
Resumo:
Summary : Forensic science - both as a source of and as a remedy for error potentially leading to judicial error - has been studied empirically in this research. A comprehensive literature review, experimental tests on the influence of observational biases in fingermark comparison, and semistructured interviews with heads of forensic science laboratories/units in Switzerland and abroad were the tools used. For the literature review, some of the areas studied are: the quality of forensic science work in general, the complex interaction between science and law, and specific propositions as to error sources not directly related to the interaction between law and science. A list of potential error sources all the way from the crime scene to the writing of the report has been established as well. For the empirical tests, the ACE-V (Analysis, Comparison, Evaluation, and Verification) process of fingermark comparison was selected as an area of special interest for the study of observational biases, due to its heavy reliance on visual observation and recent cases of misidentifications. Results of the tests performed with forensic science students tend to show that decision-making stages are the most vulnerable to stimuli inducing observational biases. For the semi-structured interviews, eleven senior forensic scientists answered questions on several subjects, for example on potential and existing error sources in their work, of the limitations of what can be done with forensic science, and of the possibilities and tools to minimise errors. Training and education to augment the quality of forensic science have been discussed together with possible solutions to minimise the risk of errors in forensic science. In addition, the time that samples of physical evidence are kept has been determined as well. Results tend to show considerable agreement on most subjects among the international participants. Their opinions on possible explanations for the occurrence of such problems and the relative weight of such errors in the three stages of crime scene, laboratory, and report writing, disagree, however, with opinions widely represented in existing literature. Through the present research it was therefore possible to obtain a better view of the interaction of forensic science and judicial error to propose practical recommendations to minimise their occurrence. Résumé : Les sciences forensiques - considérés aussi bien comme source de que comme remède à l'erreur judiciaire - ont été étudiées empiriquement dans cette recherche. Une revue complète de littérature, des tests expérimentaux sur l'influence du biais de l'observation dans l'individualisation de traces digitales et des entretiens semi-directifs avec des responsables de laboratoires et unités de sciences forensiques en Suisse et à l'étranger étaient les outils utilisés. Pour la revue de littérature, quelques éléments étudies comprennent: la qualité du travail en sciences forensiques en général, l'interaction complexe entre la science et le droit, et des propositions spécifiques quant aux sources d'erreur pas directement liées à l'interaction entre droit et science. Une liste des sources potentielles d'erreur tout le long du processus de la scène de crime à la rédaction du rapport a également été établie. Pour les tests empiriques, le processus d'ACE-V (analyse, comparaison, évaluation et vérification) de l'individualisation de traces digitales a été choisi comme un sujet d'intérêt spécial pour l'étude des effets d'observation, due à son fort recours à l'observation visuelle et dû à des cas récents d'identification erronée. Les résultats des tests avec des étudiants tendent à prouver que les étapes de prise de décision sont les plus vulnérables aux stimuli induisant des biais d'observation. Pour les entretiens semi-structurés, onze forensiciens ont répondu à des questions sur des sujets variés, par exemple sur des sources potentielles et existantes d'erreur dans leur travail, des limitations de ce qui peut être fait en sciences forensiques, et des possibilités et des outils pour réduire au minimum ses erreurs. La formation et l'éducation pour augmenter la qualité des sciences forensiques ont été discutées ainsi que les solutions possibles pour réduire au minimum le risque d'erreurs en sciences forensiques. Le temps que des échantillons sont gardés a été également déterminé. En général, les résultats tendent à montrer un grand accord sur la plupart des sujets abordés pour les divers participants internationaux. Leur avis sur des explications possibles pour l'occurrence de tels problèmes et sur le poids relatif de telles erreurs dans les trois étapes scène de crime;', laboratoire et rédaction de rapports est cependant en désaccord avec les avis largement représentés dans la littérature existante. Par cette recherche il était donc possible d'obtenir une meilleure vue de l'interaction des sciences forensiques et de l'erreur judiciaire afin de proposer des recommandations pratiques pour réduire au minimum leur occurrence. Zusammenfassung : Forensische Wissenschaften - als Ursache und als Hilfsmittel gegen Fehler, die möglicherweise zu Justizirrtümern führen könnten - sind hier empirisch erforscht worden. Die eingestzten Methoden waren eine Literaturübersicht, experimentelle Tests über den Einfluss von Beobachtungseffekten (observer bias) in der Individualisierung von Fingerabdrücken und halbstandardisierte Interviews mit Verantwortlichen von kriminalistischen Labors/Diensten in der Schweiz und im Ausland. Der Literaturüberblick umfasst unter anderem: die Qualität der kriminalistischen Arbeit im Allgemeinen, die komplizierte Interaktion zwischen Wissenschaft und Recht und spezifische Fehlerquellen, welche nicht direkt auf der Interaktion von Recht und Wissenschaft beruhen. Eine Liste möglicher Fehlerquellen vom Tatort zum Rapportschreiben ist zudem erstellt worden. Für die empirischen Tests wurde der ACE-V (Analyse, Vergleich, Auswertung und Überprüfung) Prozess in der Fingerabdruck-Individualisierung als speziell interessantes Fachgebiet für die Studie von Beobachtungseffekten gewählt. Gründe sind die Wichtigkeit von visuellen Beobachtungen und kürzliche Fälle von Fehlidentifizierungen. Resultate der Tests, die mit Studenten durchgeführt wurden, neigen dazu Entscheidungsphasen als die anfälligsten für Stimuli aufzuzeigen, die Beobachtungseffekte anregen könnten. Für die halbstandardisierten Interviews beantworteten elf Forensiker Fragen über Themen wie zum Beispiel mögliche und vorhandene Fehlerquellen in ihrer Arbeit, Grenzen der forensischen Wissenschaften und Möglichkeiten und Mittel um Fehler zu verringern. Wie Training und Ausbildung die Qualität der forensischen Wissenschaften verbessern können ist zusammen mit möglichen Lösungen zur Fehlervermeidung im selben Bereich diskutiert worden. Wie lange Beweismitten aufbewahrt werden wurde auch festgehalten. Resultate neigen dazu, für die meisten Themen eine grosse Übereinstimmung zwischen den verschiedenen internationalen Teilnehmern zu zeigen. Ihre Meinungen über mögliche Erklärungen für das Auftreten solcher Probleme und des relativen Gewichts solcher Fehler in den drei Phasen Tatort, Labor und Rapportschreiben gehen jedoch mit den Meinungen, welche in der Literatur vertreten werden auseinander. Durch diese Forschungsarbeit war es folglich möglich, ein besseres Verständnis der Interaktion von forensischen Wissenschaften und Justizirrtümer zu erhalten, um somit praktische Empfehlungen vorzuschlagen, welche diese verringern. Resumen : Esta investigación ha analizado de manera empírica el rol de las ciencias forenses como fuente y como remedio de potenciales errores judiciales. La metodología empleada consistió en una revisión integral de la literatura, en una serie de experimentos sobre la influencia de los sesgos de observación en la individualización de huellas dactilares y en una serie de entrevistas semiestructuradas con jefes de laboratorios o unidades de ciencias forenses en Suiza y en el extranjero. En la revisión de la literatura, algunas de las áreas estudiadas fueron: la calidad del trabajo en ciencias forenses en general, la interacción compleja entre la ciencia y el derecho, así como otras fuentes de error no relacionadas directamente con la interacción entre derecho y ciencia. También se ha establecido una lista exhaustiva de las fuentes potenciales de error desde la llegada a la escena del crimen a la redacción del informe. En el marco de los tests empíricos, al analizar los sesgos de observación dedicamos especial interés al proceso de ACE-V (análisis, comparación, evaluación y verificación) para la individualización de huellas dactilares puesto que este reposa sobre la observación visual y ha originado varios casos recientes de identificaciones erróneas. Los resultados de las experimentaciones realizadas con estudiantes sugieren que las etapas en las que deben tornarse decisiones son las más vulnerables a lös factores que pueden generar sesgos de observación. En el contexto de las entrevistas semi-estructuradas, once científicos forenses de diversos países contestaron preguntas sobre varios temas, incluyendo las fuentes potenciales y existehtes de error en su trabajo, las limitaciones propias a las ciencias forenses, las posibilidades de reducir al mínimo los errores y las herramientas que podrían ser utilizadas para ello. Se han sugerido diversas soluciones para alcanzar este objetivo, incluyendo el entrenamiento y la educación para aumentar la calidad de las ciencias forenses. Además, se ha establecido el periodo de conservación de las muestras judiciales. Los resultados apuntan a un elevado grado de consenso entre los entrevistados en la mayoría de los temas. Sin embargo, sus opiniones sobre las posibles causas de estos errores y su importancia relativa en las tres etapas de la investigación -la escena del crimen, el laboratorio y la redacción de informe- discrepan con las que predominan ampliamente en la literatura actual. De este modo, esta investigación nos ha permitido obtener una mejor imagen de la interacción entre ciencias forenses y errores judiciales, y comenzar a formular una serie de recomendaciones prácticas para reducirlos al minimo.
Resumo:
A luminescent bacterial biosensor was used to quantify bioavailable arsenic in artificial groundwater. Its light production above the background emission was proportional to the arsenite concentration in the toxicologically relevant range of 0 to 0.5 mu M. Effects of the inorganic solutes phosphate, Fe(II) and silicate on the biosensor signal were studied. Phosphate at a concentration of 0.25 g L-1 phosphate slightly stimulated the light emission, but much less than toxicologically relevant concentrations of the much stronger inducer arsenite. No effect of phosphate was oberved in the presence of arsenite. Freshly prepared sodium silicate solution at a concentration of 10 g L-1 Si reduced the arsenite-induced light production by roughly 37%, which can be explained by transient polymerization leading to sequestration of some arsenic. After three days of incubation, silicate did not have this effect anymore, probably because depolymerization occurred. In the presence of 0.4 g L-1 Fe(II), the arsenite-induced light emission was reduced by up to 90%, probably due to iron oxidation followed by arsenite adsorption on the less soluble Fe(III) possibly along with some oxidation to the stronger adsorbing As(V). Addition of 100 mu M EDTA was capable of releasing all arsenic from the precipitate and to transform it into the biologically measurable, dissolved state. The biosensor also proved valuable for monitoring the effectiveness of an arsenic removal procedure based on water filtration through a mixture of sand and iron granules.
Resumo:
The frequency and severity of human infections associated with Corynebacterium ulcerans appear to be increasing in different countries. Here, we describe the first C. ulcerans strain producing a diphtheria-like toxin isolated from an elderly woman with a fatal pulmonary infection and a history of leg skin ulcers in the Rio de Janeiro metropolitan area.
Resumo:
Elevation of the biliary CEA level in patients with liver metastases from colorectal carcinoma has been reported. The aim of this study is to determine the potential value of biliary CEA assay in the early detection of liver metastases. Biliary and serum CEA levels were determined in patients operated on for a colorectal cancer and in control groups. Among 13 patients with liver metastases from colorectal carcinomas, biliary CEA levels were markedly elevated (> 40 ng/ml) in nine, moderately elevated (5-40 ng/ml) in two and normal (arbitrarily defined as < 5 ng/ml) in two. Of 28 patients with primary colorectal carcinoma without detectable hepatic secondaries, three had marked CEA elevation in the bile, 10 had moderate CEA elevation and 15 had normal levels. Among nine patients with non-malignant hepatobiliary pathology, there was one marked biliary CEA elevation, one moderate elevation and seven normal levels. None of the 13 individuals with no identified hepatobiliary pathology had elevated biliary CEA levels. The follow-up of patients with a primary colorectal tumour, no evidence of hepatic secondaries and a biliary CEA elevation is of particular interest. If subsequent appearance of liver metastases is found in such cases, intra-operative biliary CEA assay could be considered a valuable diagnostic test. Further studies will then have to prove the possible benefit of a specific treatment for this group of patients.