930 resultados para Error amplification
Resumo:
A novel distributed Raman amplification scheme for quasi-lossless transmission is presented. The scheme is able to keep signal power variations below 3 dB in a 100 km periodic cell and 0.36 dB in 60 km.
Resumo:
The existence of an optimal span length for 40 Gbit/s WDM transmission systems with hybrid Raman/EDFA amplification is demonstrated. Optimal lengths are obtained for specific amplifier configurations and different fibre arrangements based on SSMF/DCF and SLA/IDF implementation, using a simple nonlinearity management theory.
Resumo:
In this letter, we experimentally study the statistical properties of a received QPSK modulated signal and compare various bit error rate (BER) estimation methods for coherent optical orthogonal frequency division multiplexing transmission. We show that the statistical BER estimation method based on the probability density function of the received QPSK symbols offers the most accurate estimate of the system performance.
Resumo:
Background/aim: The technique of photoretinoscopy is unique in being able to measure the dynamics of the oculomotor system (ocular accommodation, vergence, and pupil size) remotely (working distance typically 1 metre) and objectively in both eyes simultaneously. The aim af this study was to evaluate clinically the measurement of refractive error by a recent commercial photoretinoscopic device, the PowerRefractor (PlusOptiX, Germany). Method: The validity and repeatability of the PowerRefractor was compared to: subjective (non-cycloplegic) refraction on 100 adult subjects (mean age 23.8 (SD 5.7) years) and objective autarefractian (Shin-Nippon SRW-5000, Japan) on 150 subjects (20.1 (4.2) years). Repeatability was assessed by examining the differences between autorefractor readings taken from each eye and by re-measuring the objective prescription of 100 eyes at a subsequent session. Results: On average the PowerRefractor prescription was not significantly different from the subjective refraction, although quite variable (difference -0.05 (0.63) D, p = 0.41) and more negative than the SRW-5000 prescription (by -0.20 (0.72) D, p<0.001). There was no significant bias in the accuracy of the instrument with regard to the type or magnitude of refractive error. The PowerRefractor was found to be repeatable over the prescription range of -8.75D to +4.00D (mean spherical equivalent) examined. Conclusion: The PowerRefractor is a useful objective screening instrument and because of its remote and rapid measurement of both eyes simultaneously is able to assess the oculomotor response in a variety of unrestricted viewing conditions and patient types.
Resumo:
Purpose. Whereas many previous studies have identified the association between sustained near work and myopia, few have assessed the influence of concomitant levels of cognitive effort. This study investigates the effect of cognitive effort on near-work induced transient myopia (NITM). Methods. Subjects comprised of six early onset myopes (EOM; mean age 23.7 yrs; mean onset 10.8 yrs), six late-onset myopes (LOM; mean age 23.2 yrs; mean onset 20.0 yrs) and six emmetropes (EMM; mean age 23.8 yrs). Dynamic, monocular, ocular accommodation was measured with the Shin-Nippon SRW-5000 autorefractor. Subjects engaged passively or actively in a 5 minute arithmetic sum checking task presented monocularly on an LCD monitor via a Badal optical system. In all conditions the task was initially located at near (4.50 D) and immediately following the task instantaneously changed to far (0.00 D) for a further 5 minutes. The combinations of active (A) and passive (P) cognition were randomly allocated as P:P; A:P; A:A; P:A. Results. For the initial near task, LOMs were shown to have a significantly less accurate accommodative response than either EOMs or EMMs (p < 0.001). For the far task, post hoc analyses for refraction identified EOMs as demonstrating significant NITM compared to LOMs (p < 0.05), who in turn showed greater NITM than EMMs (p < 0.001). The data show that for EOMs the level of cognitive activity operating during the near and far tasks determines the persistence of NITM; persistence being maximal when active cognition at near is followed by passive cognition at far. Conclusions. Compared with EMMs, EOMs and LOMs are particularly susceptible to NITM such that sustained near vision reduces subsequent accommodative accuracy for far vision. It is speculated that the marked NITM found in EOM may be a consequence of the crystalline lens thinning shown to be a developmental feature of EOM. Whereas the role of small amounts of retinal defocus in myopigenesis remains equivocal, the results show that account needs to be taken of cognitive demand in assessing phenomena such as NITM.
Resumo:
An approach to nonlinearity management in optical transmission lines with periodic dispersion compensation and distributed Raman amplification was presented. The optimization of a three-step dispersion map with forward and backward pumped distributed amplification was examined. The optimization was performed using the analytical solution obtained under the assumption of undepleted pumps and without inclusion of double Rayleigh Scattering (DRS), and by means of a full numerical approach accounting for all important effects. It was found that both procedures led to the same final solution.
Resumo:
We develop a theoretical method to calculate jitter statistics of interacting solitons. Applying this approach, we have derived the non-Gaussian probability density function and calculated the bit-error rate as a function of noise level, initial separation and phase difference between solitons.
Resumo:
Introduction: There is a growing public perception that serious medical error is commonplace and largely tolerated by the medical profession. The Government and medical establishment's response to this perceived epidemic of error has included tighter controls over practising doctors and individual stick-and-carrot reforms of medical practice. Discussion: This paper critically reviews the literature on medical error, professional socialization and medical student education, and suggests that common themes such as uncertainty, necessary fallibility, exclusivity of professional judgement and extensive use of medical networks find their genesis, in part, in aspects of medical education and socialization into medicine. The nature and comparative failure of recent reforms of medical practice and the tension between the individualistic nature of the reforms and the collegiate nature of the medical profession are discussed. Conclusion: A more theoretically informed and longitudinal approach to decreasing medical error might be to address the genesis of medical thinking about error through reforms to the aspects of medical education and professional socialization that help to create and perpetuate the existence of avoidable error, and reinforce medical collusion concerning error. Further changes in the curriculum to emphasize team working, communication skills, evidence-based practice and strategies for managing uncertainty are therefore potentially key components in helping tomorrow's doctors to discuss, cope with and commit fewer medical errors.
Resumo:
A transmission performance investigation using ultra-long Raman fibre laser based amplification with different co-pump power is presented. We attribute Q2 factor degradation to RIN of co-pump and induced fibre laser as well as increased SBS.
Resumo:
Glyceraldehyde-3-phosphate dehydrogenase (GAPDH) is an enzyme which catalyses the conversion of glyceraldehyde-3-phosphate to 1,3 diphosphoglycerate. It is considered to be constitutively expressed in all cells, and as such the gene for GAPDH (gapd) is commonly used as a benchmark reference in expression studies. However, previous investigations have demonstrated that gapd may show altered gene expression in a number of disease states and under certain experimental conditions, suggesting that results of experiments using gapd as a control should be interpreted with caution. Furthermore, consideration must be given to the potential co-amplification of pseudogenes of gapd during RT-PCR. Here, we describe a method to avoid the amplification of contaminating pseudogenes through the design of primers that bind only to genuine gapd mRNA transcript. © 2003 Elsevier Ltd. All rights reserved.
Resumo:
In this work, we determine the coset weight spectra of all binary cyclic codes of lengths up to 33, ternary cyclic and negacyclic codes of lengths up to 20 and of some binary linear codes of lengths up to 33 which are distance-optimal, by using some of the algebraic properties of the codes and a computer assisted search. Having these weight spectra the monotony of the function of the undetected error probability after t-error correction P(t)ue (C,p) could be checked with any precision for a linear time. We have used a programm written in Maple to check the monotony of P(t)ue (C,p) for the investigated codes for a finite set of points of p € [0, p/(q-1)] and in this way to determine which of them are not proper.
Resumo:
The emergence of digital imaging and of digital networks has made duplication of original artwork easier. Watermarking techniques, also referred to as digital signature, sign images by introducing changes that are imperceptible to the human eye but easily recoverable by a computer program. Usage of error correcting codes is one of the good choices in order to correct possible errors when extracting the signature. In this paper, we present a scheme of error correction based on a combination of Reed-Solomon codes and another optimal linear code as inner code. We have investigated the strength of the noise that this scheme is steady to for a fixed capacity of the image and various lengths of the signature. Finally, we compare our results with other error correcting techniques that are used in watermarking. We have also created a computer program for image watermarking that uses the newly presented scheme for error correction.
Resumo:
We experimentally study the generation and amplification of stable picosecond-short optical pulses by a master oscillator power-amplifier configuration consisting of a monolithic quantum-dot-based gain-guided tapered laser and amplifier emitting at 1.26 μm without pulse compression, external cavity, gain-or Q-switched operation. We report a peak power of 42 W and a figure-of-merit for second-order nonlinear imaging of 38.5 W2 at a repetition rate of 16 GHz and an associated pulse width of 1.37 ps.
Resumo:
We extend our previous work into error-free representations of transform basis functions by presenting a novel error-free encoding scheme for the fast implementation of a Linzer-Feig Fast Cosine Transform (FCT) and its inverse. We discuss an 8x8 L-F scaled Discrete Cosine Transform where the architecture uses a new algebraic integer quantization of the 1-D radix-8 DCT that allows the separable computation of a 2-D DCT without any intermediate number representation conversions. The resulting architecture is very regular and reduces latency by 50% compared to a previous error-free design, with virtually the same hardware cost.