913 resultados para Endurance sports training.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest document pretén recollir aportacions teòriques i pràctiques sobre les pràctiques pedagògiques que incorporen i promouen l'ús de les TIC per tal d'aclarir, facilitar i fer coherent el disseny de la formació dels professors d'educació superior en les TIC. El seu propòsit és trobar alternatives de formació que compleixin amb les necessitats educatives del professor, així com per superar o atenuar les dificultats i/o la manca de voluntat a les quals s'enfronta en la pràctica educativa en introduir aplicacions de les TIC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the evolution of fear of falling, and its relationship with gait performance after a 10-week gait and balance training program. Population and methods: Participants (N=50) were community-dwelling elderly persons enrolled voluntarily in a 10-week, low intensity, gait and balance training program. At baseline, fear of falling was assessed using a previously validated version of Tinetti's Fall Efficacy Scale (FES, range 0-120, higher score indicating higher confidence), that assesses one's confidence in performing 12 activities of daily life without falling. Gait parameters were measured over a 20m walk at preferred gait speed, using the Physilog system (Aminian K, et al., J Biomechanics, 2002). This system uses 4 kinematics sensors attached to the lower limbs and a data logger carried by the subject. Follow-up data on fear of falling and gait were collected one week after completion of the program. Results: Overall, 43 (86%) of the participants completed the program. Mean age was 78.1 years, 79% were women. At baseline, mean FES score was 98.8 (range 58-120) and mean gait speed was 0.92 m/sec (range 0.43-1.47). At follow-up, participants modestly improved their FES score (98.8±17.0 vs 103.2±16.0, P=.04) and gait speed (0.92±0.27 vs 0.99±0.26 m/sec, P<.01). In secondary analyses stratified by subject's baseline FES, those with lower than average confidence (N=21) improved significantly both FES score (84.4±11.8 vs 94.5±17.9, P<.01) and gait speed (0.79±0.26 vs 0.90±0.28 m/sec, P<.01), while no similar improvement was observed in subjects (N=22) with higher baseline confidence (112.5±6.6 vs 111.5±7.5, P=.56 and 1.03±0.22 vs 1.07±0.21 m/sec, P=.41). After adjustment for age, gender and baseline gait speed, subjects with lower baseline confidence had higher odds than the others to improve their confidence (AdjOR=10.8, 95%CI 1.8- 64.8 P=.01) and gait speed (AdjOR=3.3, 95%CI 0.6-19.7, P=.19) at follow-up. Conclusions: This pilot program of low intensity exercise modestly improved participants' fear of falling and gait speed. Interestingly, subjects with higher baseline fear of falling seemed more likely to benefit. Despite methodological limitations (pre-post comparisons, small sample), these results suggest that measuring fear of falling might be useful to better target subjects most likely to benefit from similar programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reseña del congreso WePreserve 2009 que tuvo lugar los pasados 23 al 27 de marzo en Barcelona, organizadopor la Facultad de Biblioteconomía y Documentación de la Universitat de Barcelona, con la colaboración del Institut d'Estudis Catalans, la Biblioteca de Catalunya y el Consorci de Biblioteques de Barcelona. El seminario 2009 WePreserve se celebra anualmente desde el año 2007 y participan todas las figuras de referencia europeas en materia de investigación en sistemas y metodologías que garantizan la preservación digital de los documentos: Digital Preservation Europe (DPE), Preservation and Long-term Access Through Networked Services (Planets), Cultural Artistic and Scientific Knowledge for Preservation, Access and Retrieval (CASPAR), y Network of expertise in Digital long-term preservation (nestor).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article discusses the lessons learned from developing and delivering the Vocational Management Training for the European Tourism Industry (VocMat) online training programme, which was aimed at providing flexible, online distance learning for the European tourism industry. The programme was designed to address managers ‘need for flexible, senior management level training which they could access at a time and place which fitted in with their working and non-work commitments. The authors present two main approaches to using the Virtual Learning Environment, the feedback from the participants, and the implications of online Technology in extending tourism training opportunities

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of new medical devices, such as aortic valves, requires numerous preliminary studies on animals and training of personnel on cadavers before the devices can be used in patients. Postmortem circulation, a technique used for postmortem angiography, allows the vascular system to be reperfused in a way similar to that in living persons. This technique is used for postmortem investigations to visualize the human vascular system and to make vascular diagnoses. Specific material for reperfusing a human body was developed recently. Our aim was to investigate whether postmortem circulation that imitates in vivo conditions allows for the testing of medical materials on cadavers. We did this by delivering an aortic valve using minimally invasive methods. Postmortem circulation was established in eight corpses to recreate an environment as close as possible to in vivo conditions. Mobile fluoroscopy and a percutaneous catheterization technique were used to deliver the material to the correct place. Once the valve was implanted, the heart and primary vessels were extracted to confirm its position. Postmortem circulation proved to be essential in several of the cadavers because it helped the clinicians to deliver the material and improve their implantation techniques. Due to the intravascular circulation, sites with substantial arteriosclerotic stenosis could be bypassed, which would have been impossible without perfusion. Although originally developed for postmortem investigations, this reperfusion technique could be useful for testing new medical devices intended for living patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the validity and reliability of a sequential "Run-Bike-Run" test (RBR) in age-group triathletes. Eight Olympic distance (OD) specialists (age 30.0 ± 2.0 years, mass 75.6 ± 1.6 kg, run VO2max 63.8 ± 1.9 ml· kg(-1)· min(-1), cycle VO2peak 56.7 ± 5.1 ml· kg(-1)· min(-1)) performed four trials over 10 days. Trial 1 (TRVO2max) was an incremental treadmill running test. Trials 2 and 3 (RBR1 and RBR2) involved: 1) a 7-min run at 15 km· h(-1) (R1) plus a 1-min transition to 2) cycling to fatigue (2 W· kg(-1) body mass then 30 W each 3 min); 3) 10-min cycling at 3 W· kg(-1) (Bsubmax); another 1-min transition and 4) a second 7-min run at 15 km· h(-1) (R2). Trial 4 (TT) was a 30-min cycle - 20-min run time trial. No significant differences in absolute oxygen uptake (VO2), heart rate (HR), or blood lactate concentration ([BLA]) were evidenced between RBR1 and RBR2. For all measured physiological variables, the limits of agreement were similar, and the mean differences were physiologically unimportant, between trials. Low levels of test-retest error (i.e. ICC <0.8, CV<10%) were observed for most (logged) measurements. However [BLA] post R1 (ICC 0.87, CV 25.1%), [BLA] post Bsubmax (ICC 0.99, CV 16.31) and [BLA] post R2 (ICC 0.51, CV 22.9%) were least reliable. These error ranges may help coaches detect real changes in training status over time. Moreover, RBR test variables can be used to predict discipline specific and overall TT performance. Cycle VO2peak, cycle peak power output, and the change between R1 and R2 (deltaR1R2) in [BLA] were most highly related to overall TT distance (r = 0.89, p < 0. 01; r = 0.94, p < 0.02; r = 0.86, p < 0.05, respectively). The percentage of TR VO2max at 15 km· h(-1), and deltaR1R2 HR, were also related to run TT distance (r = -0.83 and 0.86, both p < 0.05).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During recovery from a maximal or submaximal aerobic exercise, augmentation of central (aortic) systolic pressure by reflected pressure waves is blunted in healthy humans. However, the extent to which reflected pressure waves modify the central pulse in diastole in these conditions remains unknown. We evaluated systolic and diastolic central reflected waves in 11 endurance-trained athletes on recovery from a maximal running test on a treadmill (treadmill-max) and a 4000 m run in field conditions. On both occasions in each subject, the radial pulse was recorded with applanation tonometry in the resting preexercise state and then 5, 15, 25, 35, and 45 min after exercise termination. From the central waveform, as reconstructed by application of a generalized transfer function, we computed a systolic (AIx) and a diastolic index (AId) of pressure augmentation by reflections. At 5 min, both indices were below preexercise. At further time-points, AIx remained low, while AId progressively increased, to overshoot above preexercise at 45 min. The same behavior was observed with both exercise types. Beyond the first few minutes of recovery following either maximal or submaximal aerobic exercise, reflected waves selectively augment the central pressure pulse in diastole, at least in endurance-trained athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Boletín semanal para profesionales sanitarios de la Secretaría General de Salud Pública y Participación Social de la Consejería de Salud