927 resultados para Endovascular Presence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gas sensors have been used widely in different important area including industrial control, environmental monitoring, counter-terrorism and chemical production. Micro-fabrication offers a promising way to achieve sensitive and inexpensive gas sensors. Over the years, various MEMS gas sensors have been investigated and fabricated. One significant type of MEMS gas sensors is based on mass change detection and the integration with specific polymer. This dissertation aims to make contributions to the design and fabrication of MEMS resonant mass sensors with capacitance actuation and sensing that lead to improved sensitivity. To accomplish this goal, the research has several objectives: (1) Define an effective measure for evaluating the sensitivity of resonant mass devices; (2) Model the effects of air damping on microcantilevers and validate models using laser measurement system (3) Develop design guidelines for improving sensitivity in the presence of air damping; (4) Characterize the degree of uncertainty in performance arising from fabrication variation for one or more process sequences, and establish design guidelines for improved robustness. Work has been completed toward these objectives. An evaluation measure has been developed and compared to an RMS based measure. Analytic models of air damping for parallel plate that include holes are compared with a COMSOL model. The models have been used to identify cantilever design parameters that maximize sensitivity. Additional designs have been modeled with COMSOL and the development of an analytical model for Fixed-free cantilever geometries with holes has been developed. Two process flows have been implemented and compared. A number of cantilever designs have been fabricated and the uncertainty in process has been investigated. Variability from processing have been evaluated and characterized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compares MRI and MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms (EVAR). Forty-three patients with previous EVAR underwent both MRI (2D T1-FFE unenhanced and contrast-enhanced; 3D triphasic contrast-enhanced) and 16-slice MDCT (unenhanced and biphasic contrast-enhanced) within 1 week of each other for endoleak detection. MRI was performed by using a high-relaxivity contrast medium (gadobenate dimeglumine, MultiHance). Two blinded, independent observers evaluated MRI and MDCT separately. Consensus reading of MRI and MDCT studies was defined as reference standard. Sensitivity, specificity, and accuracy were calculated and Cohen's k statistics were used to estimate agreement between readers. Twenty endoleaks were detected in 18 patients at consensus reading (12 type II and 8 indeterminate endoleaks). Sensitivity, specificity, and accuracy for endoleak detection were 100%, 92%, and 96%, respectively, for reader 1 (95%, 81%, 87% for reader 2) for MRI and 55%, 100%, and 80% for reader 1 (60%, 100%, 82% for reader 2) for MDCT. Interobserver agreement was excellent for MDCT (k = 0.96) and good for MRI (k = 0.81). MRI with the use of a high-relaxivity contrast agent is significantly superior in the detection of endoleaks after EVAR compared with MDCT. MRI may therefore become the preferred technique for patient follow-up after EVAR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direction-of-arrival (DOA) estimation is susceptible to errors introduced by the presence of real-ground and resonant size scatterers in the vicinity of the antenna array. To compensate for these errors pre-calibration and auto-calibration techniques are presented. The effects of real-ground constituent parameters on the mutual coupling (MC) of wire type antenna arrays for DOA estimation are investigated. This is accomplished by pre-calibration of the antenna array over the real-ground using the finite element method (FEM). The mutual impedance matrix is pre-estimated and used to remove the perturbations in the received terminal voltage. The unperturbed terminal voltage is incorporated in MUSIC algorithm to estimate DOAs. First, MC of quarter wave monopole antenna arrays is investigated. This work augments an existing MC compensation technique for ground-based antennas and proposes reduction in MC for antennas over finite ground as compared to the perfect ground. A factor of 4 decrease in both the real and imaginary parts of the MC is observed when considering a poor ground versus a perfectly conducting one for quarter wave monopoles in the receiving mode. A simulated result to show the compensation of errors direction of arrival (DOA) estimation with actual realization of the environment is also presented. Secondly, investigations for the effects on received MC of λ/2 dipole arrays placed near real-earth are carried out. As a rule of thumb, estimation of mutual coupling can be divided in two regions of antenna height that is very near ground 0

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Endovascular repair of the descending thoracic aorta is a very promising technique in elective and, particularly, emergency situations. This study assessed the impact of urgency of the procedure on outcome and mid-term quality of life in surviving patients. METHODS: Post hoc analysis of prospectively collected data of 58 consecutive patients (January 2001-December 2005) with surgical pathologies of the descending thoracic aorta treated by endovascular means. Six patients were excluded due to recent operations on the ascending aorta before thoracic endovascular repair. The remaining patients (n=52) were 69+/-10 years old, and 43 were men (83%). Twenty-seven had been treated electively, and 25 for emergency indications. Reasons for emergency were acute type B aortic dissections with or without malperfusion syndrome in 14, and aortic ruptures in 11 cases. Follow-up was 29+/-16 months. Endpoints were perioperative and late morbidity and mortality rates and long-term quality of life as assessed by the short form health survey (SF-36) and Hospital Anxiety and Depression Scale questionnaires. RESULTS: Cohorts were comparable regarding age, sex, cardiovascular risk factors, and comorbidities. Perioperative mortality was somewhat higher in emergency cases (12% vs 4%, p=0.34). Paraplegia occurred in one patient in each cohort (4%). Overall quality of life after two and a half years was similar in both treatment cohorts: 72 (58-124) after emergency, and 85 (61-105) after elective endovascular aortic repair (p=0.98). Normal scores range from 85 to 115. Anxiety and depression scores were in the normal range and comparable. CONCLUSIONS: Thoracic endovascular aortic repair is an excellent and safe treatment option for the diseased descending aorta, particularly in emergency situations. Early morbidity and mortality rates can be kept very low. Mid-term quality of life was not affected by the urgency of the procedure. Similarly, mid-term anxiety and depression scores were not increased after emergency situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Thoracic endovascular aortic repair (TEVAR) represents an attractive alternative to open aortic repair (OAR). The aim of this study was to assess outcome and quality of life in patients treated either by TEVAR or OAR for diseased descending thoracic aorta. METHODS: A post hoc analysis of a prospectively collected consecutive series of 136 patients presenting with surgical diseases of the descending aorta between January 2001 and December 2005 was conducted. Fourteen patients were excluded because of involvement of the ascending aorta. Assessed treatment cohorts were TEVAR (n = 52) and OAR (n = 70). Mean follow-up was 34 +/- 18 months. End points were perioperative and late mortality rates and long-term quality of life as assessed by the Short Form Health Survey (SF-36) and Hospital Anxiety and Depression Score questionnaires. RESULTS: Mean age was significantly higher in TEVAR patients (69 +/- 10 years versus 62 +/- 15 years; p = 0.002). Perioperative mortality rates were 9% (OAR) and 8% (TEVAR), respectively (p = 0.254). Accordingly, cumulative long-term mortality rates were similar in both cohorts. Overall quality-of-life scores were 93 (63-110, OAR) and 83 (60-112, TEVAR), respectively. Normal quality-of-life scores range from 85 to 115. Anxiety and depression scores were not increased after open surgery. CONCLUSIONS: Thoracic endovascular aortic repair and OAR both provide excellent long-term results in treatment of thoracic aortic disease. Long-term quality of life, however, is reduced after thoracic aortic repair. Interestingly, TEVAR patients did not score higher in overall quality of life despite all advantages of minimized access trauma. Similarly, anxiety and depression scores are not reduced by TEVAR, possibly reflecting a certain caution against the new technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rhenium properties offer many interesting possibilities, therefore any ores containing rhenium would be of considerable value. Its close relationship to manganese in the periodic table led to the belief that manganese ores would be an excellent place to search for the metal. Investigation of the literature of rhenium revealed that no ore was known to contain more than 0.001 per cent of rhenium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since 1880, when Wolcott Gibbs made the suggestion that mercury could be used as a cathode in gravimetric electroanalysis, many articles have appeared in literature either criticizing the method or citing successful results which have been obtained by it.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asbestos-contaminated vermiculite attic insulation (VAI) produced from a mine near Libby, Montana, may be present in millions of homes along with other commercial asbestos-containing materials (ACM). The primary goal of the research described here was to develop and test procedures that would allow for the safe and effective weatherization of low-income homes with asbestos. The presence of asbestos insulation was confirmed by bulk sampling of the suspect asbestos material. The homes were then tested for the presence of asbestos fibers in the living spaces. All 40 homes containing VAI revealed the presence of amphibole asbestos in bulk samples. Asbestos (primarily chrysotile) was confirmed in bulk samples of ACM collected from 18 homes. Amphibole asbestos was detected in the living space of 12 (26%) homes, while chrysotile asbestos was detected in the living space of 45 (98%) homes. These results suggest that asbestos sources in homes can contribute to living space contamination

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The traditional approach to stable blunt thoracic aortic injuries (TAI) is immediate repair, with delayed repair reserved for patients with major associated injuries. In recent years, there has been a trend toward delayed repair, even in low-risk patients. This study evaluates the current practices in the surgical community regarding the timing of aortic repair and its effects on outcomes. METHODS: This was a prospective, observational multicenter study sponsored by the American Association for the Surgery of Trauma. The study included patients with blunt TAI scheduled for aortic repair by open or endovascular procedure. Patients in extremis and those managed without aortic repair were excluded. The data collection included demographics, initial clinical presentation, Injury Severity Scores, type and site of aortic injury, type of aortic repair (open or endovascular repair), and time from injury to aortic repair. The study patients were divided into an early repair (< or = 24 hours) and delayed repair groups (> 24 hours). The outcome variables included survival, ventilator days, intensive care unit (ICU) and hospital lengths of stay, blood transfusions, and complications. The outcomes in the two groups were compared with multivariate analysis after adjusting for age, Glasgow Coma Scale, hypotension, major associated injuries, and type of aortic repair. A second multivariate analysis compared outcomes between early and delayed repair, in patients with and patients without major associated injuries. RESULTS: There were 178 patients with TAI eligible for inclusion and analysis, 109 (61.2%) of which underwent early repair and 69 (38.8%) delayed repair. The two groups had similar epidemiologic, injury severity, and type of repair characteristics. The adjusted mortality was significantly higher in the early repair group (adjusted OR [95% CI] 7.78 [1.69-35.70], adjusted p value = 0.008). The adjusted complication rate was similar in the two groups. However, delayed repair was associated with significantly longer ICU and hospital lengths of stay. Analysis of the 108 patients without major associated injuries, adjusting for age, Glasgow Coma Scale, hypotension, and type of aortic repair, showed that in early repair there was a trend toward higher mortality rate (adjusted OR 9.08 [0.88-93.78], adjusted p value = 0.064) but a significantly lower complication rate (adjusted OR 0.4 [0.18-0.96], adjusted p value 0.040) and shorter ICU stay (adjusted p value = 0.021) than the delayed repair group. A similar analysis of the 68 patients with major associated injuries, showed a strong trend toward higher mortality in the early repair group (adjusted OR 9.39 [0.93-95.18], adjusted p value = 0.058). The complication rate was similar in both groups (adjusted p value = 0.239). CONCLUSIONS: Delayed repair of stable blunt TAI is associated with improved survival, irrespective of the presence or not of major associated injuries. However, delayed repair is associated with a longer length of ICU stay and in the group of patients with no major associated injuries a significantly higher complication rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to establish and validate a three-dimensional imaging protocol for the assessment of Computed Tomography (CT) scans of abdominal aortic aneurysms in UK EVAR trials patients. Quality control and repeatability of anatomical measurements is important for the validity of any core laboratory. METHODS: Three different observers performed anatomical measurements on 50 preoperative CT scans of aortic aneurysms using the Vitrea 2 three-dimensional post-imaging software in a core laboratory setting. We assessed the accuracy of intra and inter observer repeatability of measurements, the time required for collection of measurements, 3 different levels of automation and 3 different automated criteria for measurement of neck length. RESULTS: None of the automated neck length measurements demonstrated sufficient accuracy and it was necessary to perform checking of the important automated landmarks. Good intra and limited inter observer agreement were achieved with three-dimensional assessment. Complete assessment of the aneurysm and iliacs took an average (SD) of 17.2 (4.1) minutes. CONCLUSIONS: Aortic aneurysm anatomy can be assessed reliably and quickly using three-dimensional assessment but for scans of limited quality, manual checking of important landmarks remains necessary. Using a set protocol, agreement between observers is satisfactory but not as good as within observers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endovascular aneurysm repair has matured significantly over the last 20 years and is becoming increasingly popular as a minimally invasive treatment option for patients with abdominal aortic aneurysms (AAA). Long-term durability of this fascinating treatment, however, is in doubt as continuing aneurysmal degeneration of the aortoiliac graft attachment zones is clearly associated with late adverse sequelae. In recent years, our growing understanding of the physiopathology of AAA formation has facilitated scrutiny of various potential drug treatment concepts. In this article we review the mechanical and biological challenges associated with endovascular treatment of infrarenal AAAs and discuss potential approaches to ongoing aneurysmal degeneration, which hampers long-term outcomes of this minimally invasive therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report the application of a true lumen re-entry device in the bailout treatment of chronic total occlusions (CTO) of the superficial femoral artery (SFA) after failed angioplasty. METHODS: Nineteen patients (12 men; mean age 81 years, range 61-97) with 20 SFA CTOs and Rutherford category 2 to 5 ischemia were prospectively evaluated. All CTOs had unsuccessful recanalization using conventional techniques and were subsequently treated with the Outback LTD catheter. Follow-up at 3, 6, and 12 months included ankle/toe pressure measurement and pulse volume recordings. Endpoints were revascularization rate, target lesion revascularization, and limb salvage. RESULTS: Revascularization was achieved in 95% of the cases. There were 2 (10%) periprocedural complications unrelated to the re-entry device, which were resolved by endovascular or surgical treatment. The target lesion revascularization rate was 10%, with the 2 events occurring at 3 and 6 months, respectively, in patients with Rutherford category 4-5 ischemia. There was one below-the-knee amputation in the patient with failed revascularization. CONCLUSION: The acute failure of endovascular treatment of SFA CTOs is most often due to an inability to re-enter the true lumen after the occlusion is crossed in a subintimal plane. Bailout revascularization with the Outback LTD catheter is highly successful and shows a low device-related complication rate. This needle- and fluoroscopic-based re-entry device increases the endovascular success rate and is therefore expanding the minimally invasive treatment options for surgically unfit patients.