983 resultados para Endosseous implant


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Overview and Aims: Several behavioral and biological factors can make adolescents particularly vulnerable to unwanted pregnancies and sexually transmitted diseases. The aim of this study was to evaluate sexual behavior and contraceptive use patterns of a population of adolescents. Study Design: Retrospective study. Population: 163 female adolescents attending an Adolescence Unit for the first time, during 2010. Methods: Analysis of clinical charts and assessment of demographic data, smoking and drinking habits, drug use, gynecologic and obstetric history, sexual behavior and contraceptive use. Results: The mean age was 16.04 years (±1.32). 71.7% were students (of these, 70% had failed one or more years and were behind in their studies), 2.5% were working and 23.9% were neither studying or working. 95.1% had already had sexual intercourse and the mean age of first coitus was 14.53 years (±1.24). There was a history of at least one previous pregnancy in 77.3% of the cases. Before the first appointment at the AU, the contraceptive methods used were: the pill (33.2%, but 41.3% of these reported inconsistent use), and the condom (23.9%, with inconsistent use in 28.3% of these cases). 19.6% did not use any contraceptive method.. After counseling at the AU, 54% of the teenagers chose the contraceptive implant and 35% preferred the pill. Adolescents who had already been pregnant preferred a long acting method (namely, the contraceptive implant)in 61.9% of cases; those who had never been pregnant decided to use an oral contraceptive in 67.6% of cases (p<0.001). Conclusions: After counseling the number of teenagers using contraception increased. In this population there were a high number of adolescents with a previous pregnancy. This factor seems to have influenced the choice of the contraceptive method, with most of these adolescents choosing a long-acting method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STUDY OBJECTIVE: The main aim of this study is to evaluate the impact of adolescent pregnancy in the future contraceptive choices. A secondary aim is to verify whether these choices differ from those made after an abortion. DESIGN: Retrospective study. SETTING:Adolescent Unit of a tertiary care center. PARTICIPANTS:212 pregnant teenagers. INTERVENTIONS: Medical records review. MAIN OUTCOME MEASURES:Intended pregnancy rate and contraceptive methods used before and after pregnancy. For contraceptive choices after pregnancy we considered: Group 1 - teenagers who continued their pregnancy to delivery (n = 106) and Group 2 - the same number of adolescents who chose to terminate their pregnancy. RESULTS: The intended pregnancy rate was 14.2%. Prior to a pregnancy continued to delivery, the most widely used contraceptive method was the male condom (50.9%), followed by oral combined contraceptives (28.3%); 18.9% of adolescents were not using any contraceptive method. After pregnancy, contraceptive implant was chosen by 70.8% of subjects (P < .001) and the oral combined contraceptives remained the second most frequent option (17.9%, P = .058). Comparing these results with Group 2, we found that the outcome of the pregnancy was the main factor in the choices that were made. Thus, after a pregnancy continued to delivery, adolescents prefer the use of LARC [78.4% vs 40.5%, OR: 5,958 - 95% (2.914-12.181), P < .001)], especially contraceptive implants [70.8% vs 38.7%, OR: 4.371 - 95% (2.224-8.591), P < .001], to oral combined contraceptives [17.9% vs 57.5%, OR: 0.118 - 95% CI (0.054-0.258), P < .001]. CONCLUSION:Adolescent pregnancy and its outcome constitute a factor of change in future contraceptive choice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The classic transvenous implantation of a permanent pacemaker in a pectoral location may be precluded by obstruction of venous access through the superior vena cava or recent infection at the implant site. When these barriers to the procedure are bilateral and there are also contraindications or technical difficulties to performing a thoracotomy for an epicardial approach, the femoral vein, although rarely used, can be a viable alternative. We describe the case of a patient with occlusion of both subclavian veins and a high risk for mini-thoracotomy or videothoracoscopy, who underwent implantation of a permanent single-chamber pacemaker via the right femoral vein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The demonstrated benefits of cardiac resynchronization therapy (CRT) in reducing mortality and hospitalizations for heart failure, improving NYHA functional class and inducing reverse remodeling have led to its increasing use in clinical practice. However, its potential contribution to complex ventricular arrhythmias is controversial.We present the case of a female patient with valvular heart failure and severe systolic dysfunction, in NYHA class III and under optimal medical therapy, without previous documented ventricular arrhythmias. After implantation of a CRT defibrillator, she suffered an arrhythmic storm with multiple episodes of monomorphic ventricular tachycardia (VT), requiring 12 shocks. Subsequently, a pattern of ventricular bigeminy was observed, as well as reproducible VT runs induced by biventricular pacing. Since no other vein of the coronary sinus system was accessible, it was decided to implant an epicardial lead to stimulate the left ventricle, positioned in the left ventricular mid-lateral wall. No arrhythmias were detected in the following six months. This case highlights the possible proarrhythmic effect of biventricular pacing with a left ventricular lead positioned in the coronary sinus venous system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fully comprehending brain function, as the scale of neural networks, will only be possi-ble with the development of tools by micro and nanofabrication. Regarding specifically silicon microelectrodes arrays, a significant improvement in long-term performance of these implants is essential. This project aims to create a silicon microelectrode coating that provides high-quality electrical recordings, while limiting the inflammatory response of chronic implants. To this purpose, a combined chitosan and gold nanoparticles coating was produced allied with electrodes modification by electrodeposition with PEDOT/PSS in order to reduce the im-pedance at 1kHz. Using a dip-coating mechanism, the silicon probe was coated and then charac-terized both morphologically and electrochemically, with focus on the stability of post-surgery performance in anesthetized rodents. Since not only the inflammatory response analysis is vital, the electrodes recording degradation over time was also studied. The produced film presented a thickness of approximately 50 μm that led to an increase of impedance of less than 20 kΩ in average. On a 3 week chronic implant, the impedance in-crease on the coated probe was of 641 kΩ, compared with 2.4 MΩ obtained for the uncoated probe. The inflammatory response was also significantly reduced due to the biocompatible film as proved by histological tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analyzed 37 patients who underwent segmental wide resection of bone tumors and reconstruction with a modular titanium endoprosthesis at the Orthopaedic Oncology Group, between 1992 and 1998. Twelve patients were male and 25 were female, with a mean age of 30 years (9 - 81). The mean follow-up was 14 months (2 - 48). The diagnoses were: osteosarcoma (14 cases), metastatic carcinoma (10), Ewing's sarcoma (4), giant cell tumor (4), malignant fibrous histiocytoma (3), chondrosarcoma (1), and aneurysmal bone cyst (1). Eleven articulated total knee, 8 partial proximal femur with bipolar acetabulum, 8 partial proximal humerus, 3 total femur, 2 partial proximal tibia, 2 diaphyseal femur, 2 diaphyseal humerus, and 1 total proximal femur with cementless acetabulum endoprosthesis implant procedures were done. The complications related to the procedure included: infection (5 cases), dislocation (3), module loosening (1), and ulnar nerve paresthesia (1). We used the following criteria for the clinical evaluation: presence of pain, range of motion, reconstruction stability, surgical and oncologic complications, and patient acceptance. The results were good in 56.8% of the cases, regular in 32.4% and poor in 10.8%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The weak fixation of biomaterials within the bone structure is one of the major reasons of implants failures. Calcium phosphate (CaP) coatings are used in bone tissue engineering to improve implant osseointegration by enhancing cellular adhesion, proliferation and differentiation, leading to a tight and stable junction between implant and host bone. It has also been observed that materials compatible with bone tissue either have a CaP coating or develop such a calcified surface upon implantation. Thus, the development of bioactive coatings becomes essential for further improvement of integration with the surrounding tissue. However, most of current applied CaP coatings methods (e.g. physical vapor deposition), cannot be applied to complex shapes and porous implants, provide poor structural control over the coating and prevent incorporation of bioactive organic compounds (e.g. antibiotics, growth factors) because of the used harsh processing conditions. Layer-by-layer (LbL) is a versatile technology that permits the building-up of multilayered polyelectrolyte films in mild conditions based on the alternate adsorption of cationic and anionic elements that can integrate bioactive compounds. As it is recognized in natureâ s biomineralization process the presence of an organic template to induce mineral deposition, this work investigate a ion based biomimetic method where all the process is based on LbL methodology made of weak natural-origin polyelectrolytes. A nanostructured multilayer component, with 5 or 10 bilayers, was produced initially using chitosan and chondroitin sulphate polyelectrolyte biopolymers, which possess similarities with the extracellular matrix and good biocompatibility. The multilayers are then rinsed with a sequential passing of solutions containing Ca2+ and PO43- ions. The formation of CaP over the polyelectrolyte multilayers was confirmed by QCM-D, SEM and EDX. The outcomes show that 10 polyelectrolyte bilayer condition behaved as a  better site for initiating the formation of CaP as the precipitation occur at earlier stages than in 5 polyelectrolyte bilayers one. This denotes that higher number of bilayers could hold the CaP crystals more efficiently. This work achieved uniform coatings that can be applied to any surface with access to the liquid media in a low-temperature method, which potentiates the manufacture of effective bioactive biomaterials with great potential in orthopedic applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e Computadores

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Among the various possible embodiements of Advanced Therapies and in particular of Tissue Engineering the use of temporary scaffolds to regenerate tissue defects is one of the key issues. The scaffolds should be specifically designed to create environments that promote tissue development and not merely to support the maintenance of communities of cells. To achieve that goal, highly functional scaffolds may combine specific morphologies and surface chemistry with the local release of bioactive agents. Many biomaterials have been proposed to produce scaffolds aiming the regeneration of a wealth of human tissues. We have a particular interest in developing systems based in nanofibrous biodegradable polymers1,2. Those demanding applications require a combination of mechanical properties, processability, cell-friendly surfaces and tunable biodegradability that need to be tailored for the specific application envisioned. Those biomaterials are usually processed by different routes into devices with wide range of morphologies such as biodegradable fibers and meshes, films or particles and adaptable to different biomedical applications. In our approach, we combine the temporary scaffolds populated with therapeutically relevant communities of cells to generate a hybrid implant. For that we have explored different sources of adult and also embryonic stem cells. We are exploring the use of adult MSCs3, namely obtained from the bone marrow for the development autologous-based therapies. We also develop strategies based in extra-embryonic tissues, such as amniotic fluid (AF) and the perivascular region of the umbilical cord4 (Whartonâ s Jelly, WJ). Those tissues offer many advantages over both embryonic and other adult stem cell sourcess. These tissues are frequently discarded at parturition and its extracorporeal nature facilitates tissue donation by the patients. The comparatively large volume of tissue and ease of physical manipulation facilitates the isolation of larger numbers of stem cells. The fetal stem cells appear to have more pronounced immunomodulatory properties than adult MSCs. This allogeneic escape mechanism may be of therapeutic value, because the transplantation of readily available allogeneic human MSCs would be preferable as opposed to the required expansion stage (involving both time and logistic effort) of autologous cells. Topics to be covered: This talk will review our latest developments of nanostructured-based biomaterials and scaffolds in combination with stem cells for bone and cartilage tissue engineering.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia de Materiais

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The biventricular pacing (BVP) approach has good results in the treatment of congestive heart failure (CHF) in patients (pts) with disorders of intraventricular conduction. METHODS: We have applied BVP to 28 pts, with left ventricular pacing using minitoracotomy in 3 pts and the transvenous aproach via coronary sinus in 25 pts. The mean duration of the QRS complexes was 187 ms, in the presence of the left branch block in 22 pts, and right branch block + divisional hemiblock in 6 pts. All pts had been considerated candidates to cardiac transplantation, and were under optimized drug therapy. Sixteen pts were in Functional Class (NYHA) IV, and 12 in class III. The ejection fraction varied from 22 to 46% (average = 34%). The pacing mode employed was biventricular triple-chamber in 22 pts, and bi-ventricular dual-chamber in 6 pts (one with ICD). RESULTS: The pts were followed up for a period that ranged from 10 days to 14 months (mean 5 months). All pts presented clinical improvement after implant, chaging the NYHA Functional Class at the end of follow-up to Class I (9pts), Class II (10 pts) and Class III (6 pts). The initial mean ejection fraction have-raised to 37%. Two pts died suddenly. One patient died due to a pulmonary fungal infection. CONCLUSION: Ventricular resynchronization through BVP, improved significantly the Functional Class and, therefore, the quality of life. Assessments of myocardial function acutely performed do not reflect the clinical improvement observed.