962 resultados para Electromagnetic transient
Resumo:
This paper presents a method for electromagnetic torque ripple and copper losses reduction in (non-sinusoidal or trapezoidal) surface-mount permanent magnet synchronous machines (SM-PMSM). The method is based on an extension of classical dq transformation that makes it possible to write a vectorial model for this kind of machine (with a non-sinusoidal back-EMF waveform). This model is obtained by the application of that transformation in the classical machine per-phase model. That transformation can be applied to machines that have any type of back-EMF waveform, and not only trapezoidal or square-wave back-EMF waveforms. Implementation results are shown for an electrical converter, using the proposed vectorial model, feeding a non-sinusoidal synchronous machine (brushless DC motor). They show that the use of this vectorial mode is a way to achieve improvements in the performance of this kind of machine, considering the electromagnetic torque ripple and copper losses, if compared to a drive system that employs a classical six-step mode as a converter. Copyright (C) 2011 John Wiley & Sons, Ltd.
Resumo:
We describe the system of massive Weyl fields propagating in a background matter and interacting with an external electromagnetic field. The interaction with an electromagnetic field is due to the presence of anomalous magnetic moments. To canonically quantize this system first we develop the classical field theory treatment of Weyl spinors in frames of the Hamilton formalism which accounts for the external fields. Then, on the basis of the exact solution of the wave equation for a massive Weyl field in a background matter we obtain the effective Hamiltonian for the description of spin-flavor oscillations of Majorana neutrinos in matter and a magnetic field. Finally, we incorporate in our analysis the neutrino self-interaction which is essential when the neutrino density is sufficiently high. We also discuss the applicability of our results for the studies of collective effects in spin-flavor oscillations of supernova neutrinos in a dense matter and a strong magnetic field. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
The first measurement of neutron emission in electromagnetic dissociation of Pb-208 nuclei at the LHC is presented. The measurement is performed using the neutron zero degree calorimeters of the ALICE experiment, which detect neutral particles close to beam rapidity. The measured cross sections of single and mutual electromagnetic dissociation of Pb nuclei at root s(NN) = 2.76 TeV with neutron emission are sigma(singleEMD) = 187.4 +/- 0.2(stat)(-11.2)(+13.2) (syst) b and sigma(mutualEMD) = 5. 7 +/- 0.1(stat) +/- 0.4(syst) b, respectively. The experimental results are compared to the predictions from a relativistic electromagnetic dissociation model. DOI: 10.1103/PhysRevLett.109.252302
Resumo:
Background-Patients with acute coronary syndromes and history of stroke or transient ischemic attack (TIA) have an increased rate of recurrent cardiac events and intracranial hemorrhages. Methods and Results-We evaluated treatment effects of ticagrelor versus clopidogrel in patients with acute coronary syndrome with and without a history of prior stroke or TIA in the PLATelet inhibition and patient Outcomes (PLATO) trial. Of the 18 624 randomized patients, 1152 (6.2%) had a history of stroke or TIA. Such patients had higher rates of myocardial infarction (11.5% versus 6.0%), death (10.5% versus 4.9%), stroke (3.4% versus 1.2%), and intracranial bleeding (0.8% versus 0.2%) than patients without prior stroke or TIA. Among patients with a history of stroke or TIA, the reduction of the primary composite outcome and total mortality at 1 year with ticagrelor versus clopidogrel was consistent with the overall trial results: 19.0% versus 20.8% (hazard ratio, 0.87; 95% confidence interval, 0.66-1.13; interaction P=0.84) and 7.9% versus 13.0% (hazard ratio, 0.62; 95% confidence interval, 0.42-0.91). The overall PLATO-defined bleeding rates were similar: 14.6% versus 14.9% (hazard ratio, 0.99; 95% confidence interval, 0.71-1.37), and intracranial bleeding occurred infrequently (4 versus 4 cases, respectively). Conclusions-Patients with acute coronary syndrome with a prior history of ischemic stroke or TIA had higher rates of clinical outcomes than patients without prior stroke or TIA. However, the efficacy and bleeding results of ticagrelor in these high-risk patients were consistent with the overall trial population, with a favorable clinical net benefit and associated impact on mortality.
Resumo:
A charged particle is considered in a complex external electromagnetic field. The field is a superposition of an Aharonov-Bohm field and some additional field. Here we describe all additional fields known up to the present time that allow exact solution of the Schrodinger equation in a complex field.
Resumo:
Background In ROCKET AF, rivaroxaban was non-inferior to adjusted-dose warfarin in preventing stroke or systemic embolism among patients with atrial fibrillation (AF). We aimed to investigate whether the efficacy and safety of rivaroxaban compared with warfarin is consistent among the subgroups of patients with and without previous stroke or transient ischaemic attack (TIA). Methods In ROCKET AF, patients with AF who were at increased risk of stroke were randomly assigned (1:1) in a double-blind manner to rivaroxaban 20 mg daily or adjusted dose warfarin (international normalised ratio 2-0-3.0). Patients and investigators were masked to treatment allocation. Between Dec 18,2006, and June 17,2009,14 264 patients from 1178 centres in 45 countries were randomly assigned. The primary endpoint was the composite of stroke or non-CNS systemic embolism. In this substudy we assessed the interaction of the treatment effects of rivaroxaban and warfarin among patients with and without previous stroke or TIA. Efficacy analyses were by intention to treat and safety analyses were done in the on-treatment population. ROCKET AF is registered with ClinicalTrials.gov, number NCT00403767. Findings 7468 (52%) patients had a previous stroke (n=4907) or TIA (n=2561) and 6796 (48%) had no previous stroke or TIA. The number of events per 100 person-years for the primary endpoint in patients treated with rivaroxaban compared with warfarin was consistent among patients with previous stroke or TIA (2.79% rivaroxaban vs 2.96% warfarin; hazard ratio [HR] 0-94,95% CI 0.77-1.16) and those without (1.44% vs 1.88%; 0.77, 0.58-1-01; interaction p=0.23). The number of major and non-major clinically relevant bleeding events per 100 person-years in patients treated with rivaroxaban compared with warfarin was consistent among patients with previous stroke or TIA (13.31% rivaroxaban vs 13.87% warfarin; HR 0.96,95% CI 0.87-1-07) and those without (16.69% vs 15.19%; 1.10, 0.99-1.21; interaction p=0.08). Interpretation There was no evidence that the relative efficacy and safety of rivaroxaban compared with warfarin was different between patients who had a previous stroke or TIA and those who had no previous stroke or TIA. These results support the use of rivaroxaban as an alternative to warfarin for prevention of recurrent as well as initial stroke in patients with AF.
Resumo:
Abstract Background Hemophilia A is a bleeding disorder caused by deficiency in coagulation factor VIII. Recombinant factor VIII (rFVIII) is an alternative to plasma-derived FVIII for the treatment of hemophilia A. However, commercial manufacturing of rFVIII products is inefficient and costly and is associated to high prices and product shortage, even in economically privileged countries. This situation may be solved by adopting more efficient production methods. Here, we evaluated the potential of transient transfection in producing rFVIII in serum-free suspension HEK 293 cell cultures and investigated the effects of different DNA concentration (0.4, 0.6 and 0.8 μg/106 cells) and repeated transfections done at 34° and 37°C. Results We observed a decrease in cell growth when high DNA concentrations were used, but no significant differences in transfection efficiency and in the biological activity of the rFVIII were noticed. The best condition for rFVIII production was obtained with repeated transfections at 34°C using 0.4 μg DNA/106 cells through which almost 50 IU of active rFVIII was produced six days post-transfection. Conclusion Serum-free suspension transient transfection is thus a viable option for high-yield-rFVIII production. Work is in progress to further optimize the process and validate its scalability.
Resumo:
The research activity carried out during the PhD course in Electrical Engineering belongs to the branch of electric and electronic measurements. The main subject of the present thesis is a distributed measurement system to be installed in Medium Voltage power networks, as well as the method developed to analyze data acquired by the measurement system itself and to monitor power quality. In chapter 2 the increasing interest towards power quality in electrical systems is illustrated, by reporting the international research activity inherent to the problem and the relevant standards and guidelines emitted. The aspect of the quality of voltage provided by utilities and influenced by customers in the various points of a network came out only in recent years, in particular as a consequence of the energy market liberalization. Usually, the concept of quality of the delivered energy has been associated mostly to its continuity. Hence the reliability was the main characteristic to be ensured for power systems. Nowadays, the number and duration of interruptions are the “quality indicators” commonly perceived by most customers; for this reason, a short section is dedicated also to network reliability and its regulation. In this contest it should be noted that although the measurement system developed during the research activity belongs to the field of power quality evaluation systems, the information registered in real time by its remote stations can be used to improve the system reliability too. Given the vast scenario of power quality degrading phenomena that usually can occur in distribution networks, the study has been focused on electromagnetic transients affecting line voltages. The outcome of such a study has been the design and realization of a distributed measurement system which continuously monitor the phase signals in different points of a network, detect the occurrence of transients superposed to the fundamental steady state component and register the time of occurrence of such events. The data set is finally used to locate the source of the transient disturbance propagating along the network lines. Most of the oscillatory transients affecting line voltages are due to faults occurring in any point of the distribution system and have to be seen before protection equipment intervention. An important conclusion is that the method can improve the monitored network reliability, since the knowledge of the location of a fault allows the energy manager to reduce as much as possible both the area of the network to be disconnected for protection purposes and the time spent by technical staff to recover the abnormal condition and/or the damage. The part of the thesis presenting the results of such a study and activity is structured as follows: chapter 3 deals with the propagation of electromagnetic transients in power systems by defining characteristics and causes of the phenomena and briefly reporting the theory and approaches used to study transients propagation. Then the state of the art concerning methods to detect and locate faults in distribution networks is presented. Finally the attention is paid on the particular technique adopted for the same purpose during the thesis, and the methods developed on the basis of such approach. Chapter 4 reports the configuration of the distribution networks on which the fault location method has been applied by means of simulations as well as the results obtained case by case. In this way the performance featured by the location procedure firstly in ideal then in realistic operating conditions are tested. In chapter 5 the measurement system designed to implement the transients detection and fault location method is presented. The hardware belonging to the measurement chain of every acquisition channel in remote stations is described. Then, the global measurement system is characterized by considering the non ideal aspects of each device that can concur to the final combined uncertainty on the estimated position of the fault in the network under test. Finally, such parameter is computed according to the Guide to the Expression of Uncertainty in Measurements, by means of a numeric procedure. In the last chapter a device is described that has been designed and realized during the PhD activity aiming at substituting the commercial capacitive voltage divider belonging to the conditioning block of the measurement chain. Such a study has been carried out aiming at providing an alternative to the used transducer that could feature equivalent performance and lower cost. In this way, the economical impact of the investment associated to the whole measurement system would be significantly reduced, making the method application much more feasible.
Resumo:
The Ph.D. thesis describes the simulations of different microwave links from the transmitter to the receiver intermediate-frequency ports, by means of a rigorous circuit-level nonlinear analysis approach coupled with the electromagnetic characterization of the transmitter and receiver front ends. This includes a full electromagnetic computation of the radiated far field which is used to establish the connection between transmitter and receiver. Digitally modulated radio-frequency drive is treated by a modulation-oriented harmonic-balance method based on Krylov-subspace model-order reduction to allow the handling of large-size front ends. Different examples of links have been presented: an End-to-End link simulated by making use of an artificial neural network model; the latter allows a fast computation of the link itself when driven by long sequences of the order of millions of samples. In this way a meaningful evaluation of such link performance aspects as the bit error rate becomes possible at the circuit level. Subsequently, a work focused on the co-simulation an entire link including a realistic simulation of the radio channel has been presented. The channel has been characterized by means of a deterministic approach, such as Ray Tracing technique. Then, a 2x2 multiple-input multiple-output antenna link has been simulated; in this work near-field and far-field coupling between radiating elements, as well as the environment factors, has been rigorously taken into account. Finally, within the scope to simulate an entire ultra-wideband link, the transmitting side of an ultrawideband link has been designed, and an interesting Front-End co-design technique application has been setup.