981 resultados para ENDOSSEOUS IMPLANTS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surface functionalization of hydroxyapatite (HA) and beta-tricalcium phosphate (TCP) bioceramics with chemical ligands containing a pyrrogallol moiety was developed to improve the adhesion of bone cell precursors to the biomaterials. Fast and biocompatible copper-free click reaction with azido-modified human fetal osteoblasts resulted in improved cell binding to both HA and TCP bioceramics, opening the way for using this methodology in the preparation of cell-engineered bone implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To study the dental status and treatment needs of institutionalized older adults with chronic mental illness compared to a non-psychiatric control sample. Study Design: The sample size was 100, in which 50 were psychogeriatric patients (study group; SG) classified according to DSM-IV, with a mean age of 69.6 ± 6.7 years, and 50 non-psychiatric patients (control group; CG), with a mean age of 68.3 ± 6.9 years. Clinical oral health examinations were conducted and caries were recorded clinically using the Decayed, Missing and Filled Teeth Index (DMFT). Results were analyzed statistically using the Student"s t-test or analysis of variance. Results: Caries prevalence was 58% and 62% in SG and CG, respectively. DMFT index was 28.3 ± 6.6 in SG and 21.4 ± 6.07 in CG (p < 0.01). Mean number of decayed teeth was higher in SG (3.1) compared to CG (1.8) (p=0.047). Mean number of missing teeth were 25.2 and 16.4 in SG and CG respectively (p<0.05). DMFT scores were higher in SG in all the age groups (p < 0.01). Mean number of teeth per person needing treatment was 3.4 in SG and 1.9 in CG (p= 0.037). The need for restorative dental care was significantly lower in the SG (0.8 teeth per person) than in the CG (1.7 teeth per person) (p = 0.043). Conclusions: Institutionalized psychiatric patients have significantly worse dental status and more dental treatment needs than non-psychiatric patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the safety and efficacy of 2 doses of dexamethasone intravitreal implant (DEX implant) for treatment of noninfectious intermediate or posterior uveitis. METHODS: In this 26-week trial, eyes with noninfectious intermediate or posterior uveitis were randomized to a single treatment with a 0.7-mg DEX implant (n = 77), 0.35-mg DEX implant (n = 76), or sham procedure (n = 76). MAIN OUTCOME MEASURE: The main outcome measure was the proportion of eyes with a vitreous haze score of 0 at week 8. RESULTS: The proportion of eyes with a vitreous haze score of 0 at week 8 was 47% with the 0.7-mg DEX implant, 36% with the 0.35-mg DEX implant, and 12% with the sham (P < .001); this benefit persisted through week 26. A gain of 15 or more letters from baseline best-corrected visual acuity was seen in significantly more eyes in the DEX implant groups than the sham group at all study visits. The percentage of eyes with intraocular pressure of 25 mm Hg or more peaked at 7.1% for the 0.7-mg DEX implant, 8.7% for the 0.35-mg DEX implant, and 4.2% for the sham (P > .05 at any visit). The incidence of cataract reported in the phakic eyes was 9 of 62 (15%) with the 0.7-mg DEX implant, 6 of 51 (12%) with the 0.35-mg DEX implant, and 4 of 55 (7%) with the sham (P > .05). CONCLUSIONS: In patients with noninfectious intermediate or posterior uveitis, a single DEX implant significantly improved intraocular inflammation and visual acuity persisting for 6 months. Application to Clinical Practice Dexamethasone intravitreal implant may be used safely and effectively for treatment of intermediate and posterior uveitis. Trial Registration clinicaltrials.gov Identifier: NCT00333814.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although prosthetic joint infection (PJI) is a rare event after arthroplasty, it represents a significant complication that is associated with high morbidity, need for complex treatment, and substantial healthcare costs. An accurate and rapid diagnosis of PJI is crucial for treatment success. Current diagnostic methods in PJI are insufficient with 10-30% false-negative cultures. Consequently, there is a need for research and development into new methods aimed at improving diagnostic accuracy and speed of detection. In this article, we review available conventional diagnostic methods for the diagnosis of PJI (laboratory markers, histopathology, synovial fluid and periprosthetic tissue cultures), new diagnostic methods (sonication of implants, specific and multiplex PCR, mass spectrometry) and innovative techniques under development (new laboratory markers, microcalorimetry, electrical method, reverse transcription [RT]-PCR, fluorescence in situ hybridization [FISH], biofilm microscopy, microarray identification, and serological tests). The results of highly sensitive diagnostic techniques with unknown specificity should be interpreted with caution. The organism identified by a new method may represent a real pathogen that was unrecognized by conventional diagnostic methods or contamination during specimen sampling, transportation, or processing. For accurate interpretation, additional studies are needed, which would evaluate the long-term outcome (usually >2 years) with or without antimicrobial treatment. It is expected that new rapid, accurate, and fully automatic diagnostic tests will be developed soon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’ús generalitzat dels implants coclears ha possibilitat l’accés al món sonor a moltes persones amb sordesa pregona, facilitant la seva competència comunicativa en llenguatge oral. Objectiu: Amb aquest article pretenem realitzar una revisió de la descripció que tradicionalment ha caracteritzat la veu dels infants amb sordesa. Posteriorment, analitzem l’evolució de la qualitat vocal obtinguda amb una mostra de 12 infants (8 nenes i 4 nens) amb sordesa pregona congènita i una mitjana d’edat de 6 anys i 1 mes, usuaris d’Implant Coclear (IC), als quals vam realitzar una avaluació inicial de la seva qualitat vocal i una avaluació final, dos anys més tard. Els resultats es comparen amb els obtinguts per un grup control d’infants oients. Resultats i conclusions: Els resultats mostren com els perfils obtinguts pels infants sords usuaris d’IC evolucionen molt favorablement, essent els valors obtinguts més similars als del grup control en l’avaluació final que en la inicial. Finalment, ens qüestionem la validesa d’utilitzar alguns paràmetres acústics com a indicadors de la qualitat vocal dels infants amb pèrdua auditiva i sense problemes laringis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Systemic administration of cyclosporine A (CsA) is commonly used in the treatment of local ophthalmic conditions involving cytokines, such as corneal graft rejection, autoimmune uveitis and dry eye syndrome. Local administration is expected to avoid the various side effects associated with systemic delivery. However, the currently available systems using oils to deliver CsA topically are poorly tolerated and provide a low bioavailability. These difficulties may be overcome through formulations aimed at improving CsA water solubility (e.g. cyclodextrins), or those designed to facilitate tissue drug penetration using penetration enhancers. The use of colloidal carriers (micelles, emulsions, liposomes and nanoparticles) as well as the approach using hydrosoluble prodrugs of CsA have shown promising results. Solid devices such as shields and particles of collagen have been investigated to enhance retention time on the eye surface. Some of these topical formulations have shown efficacy in the treatment of extraocular diseases but were inefficient at reaching intraocular targets. Microspheres, implants and liposomes have been developed to be directly administered subconjunctivally or intravitreally in order to enhance CsA concentration in the vitreous. Although progress has been made, there is still room for improvement in CsA ocular application, as none of these formulations is ideal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To study prospectively the success rate and complications of deep sclerectomy with collagen implant (DSCI). SETTING: Glaucoma Unit, Department of Ophthalmology, Hôpital Ophtalmique Jules Gonin, University of Lausanne, Lausanne, Switzerland. METHODS: This nonrandomized prospective trial comprised 105 eyes of 105 patients with medically uncontrolled primary and secondary open-angle glaucoma. Visual acuity, intraocular pressure (IOP), and slitlamp examinations were performed before surgery and after surgery at 1 and 7 days, and 1, 3, 6, 9, 12, 18, 24, 30, 36, 48, 54, 60, 66, 72, 78, 84, 90, and 96 months. Visual field examinations were repeated every 6 months. RESULTS: Mean follow-up period was 64 months +/- 26.6 (SD). Mean preoperative IOP was 26.8 +/- 7.7 mm Hg, and mean postoperative IOP was 5.2 +/- 3.35 mm Hg at day 1 and 12 +/- 3 mm Hg at month 78. At 96 months, the qualified success rate (ie, patients who achieved IOP <21 mm Hg with and without medication) was 91%, and the complete success rate (ie, IOP <21 mm Hg without medication) was 57%. At 96 months, 34% of patients had an IOP <21 mm Hg with medication. Fifty-one patients (49%) achieved an IOP < or =15 mm Hg without medication. Neodymium:YAG goniopuncture was performed in 54 patients (51%); mean time of goniopuncture performance was 21 months, and mean IOP before goniopuncture was 20 mm Hg, dropping to 11 mm Hg after goniopuncture. No shallow or flat anterior chamber, endophthalmitis, or surgery-induced cataract was observed. However, 26 patients (25%) showed a progression of preexisting senile cataract (mean time 26 months; range 18 to 37 months). Injections of 5-fluorouracil were administered to 25 patients (23%) who underwent DSCI to salvage encysted blebs. Mean number of medications per patient was reduced from 2.3 +/- 0.7 to 0.5 +/- 0.7 (signed rank P<.0001). CONCLUSION: Deep sclerectomy with collagen implant appears to provide stable and reasonable control of IOP at long-term follow-up with few immediate postoperative complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the safety and efficacy of an intravitreal fluocinolone acetonide (FA) implant compared with standard therapy in subjects with noninfectious posterior uveitis (NIPU). DESIGN: Randomized, controlled, phase 2b/3, open-label, multicenter superiority trial. PARTICIPANTS: Subjects with unilateral or bilateral NIPU. METHODS: One hundred forty subjects received either a 0.59-mg FA intravitreal implant (n = 66) or standard of care (SOC; n = 74) with either systemic prednisolone or equivalent corticosteroid as monotherapy (> or =0.2 mg/kg daily) or, if judged necessary by the investigator, combination therapy with an immunosuppressive agent plus a lower dose of prednisolone or equivalent corticosteroid (> or =0.1 mg/kg daily). MAIN OUTCOME MEASURES: Time to first recurrence of uveitis. RESULTS: Eyes that received the FA intravitreal implant experienced delayed onset of observed recurrence of uveitis (P<0.01) and a lower rate of recurrence of uveitis (18.2% vs. 63.5%; P< or =0.01) compared with SOC study eyes. Adverse events frequently observed in implanted eyes included elevated intraocular pressure (IOP) requiring IOP-lowering surgery (occurring in 21.2% of implanted eyes) and cataracts requiring extraction (occurring in 87.8% of phakic implanted eyes). No treatment-related nonocular adverse events were observed in the implant group, whereas such events occurred in 25.7% of subjects in the SOC group. CONCLUSIONS: The FA intravitreal implant provided better control of inflammation in patients with uveitis compared with systemic therapy. Intraocular pressure and lens clarity of implanted eyes need close monitoring in patients receiving the FA intravitreal implant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS: A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS: Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION: Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The implantable loop recorder developed by Medtronic (Reveal plus) is a small device inserted subcutaneously under local anesthesia in patients with syncope of unexplained origin. This device enables a single lead-ECG recording and has autonomy of two years. Memories are activated during episodes of bradycardia or tachycardia, either automatically or manually. Several studies have shown a high diagnostic rate reaching 50% and demonstrated its cost-effectiveness. There is also a significant reduction in syncopal episodes and a higher quality of life score in patients with syncope of unexplained origin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La luxation d'une prothèse totale de la hanche est une complication majeure en termes de morbidité pour le patient et des coûts pour le système de santé. Cette complication est retrouvée entre 2 à 3% selon les séries (1-3) pour des prothèses primaires, et beaucoup plus élevée suite à des révisions. Pour remédier à ce problème, des systèmes de prothèses contraintes sont une option, cependant associés à des descellements fréquents entre 10 à 26 % selon les séries (4-6). Ces échecs étant en partie expliqués par une usure rapide des surfaces de frottements due aux fortes contraintes, mais également par les contraintes cupule-os occasionnant des descellements mécaniques (7). Par conséquent, pour augmenter la stabilité, tout en évitant les contraintes sur le couple de frottement, Bousquet développe, en 1976, une prothèse totale de hanche « à double mobilité ». Ce système consiste à combiner deux articulations apparentes, premièrement une tête métallique dans un insert de polyéthylène, articulé lui- même dans la concavité d'une cupule métallique fixée au bassin. En tant que tel, ce système biomécanique réduirait en théorie le risque de luxation. Dès lors, on aperçoit depuis environ 15 ans une augmentation progressive de l'utilisation de ce type d'implants que ce soit comme implant primaire ou secondaire, chez des patients jeunes ou âgés. Cependant, des études in vitro, ont montré que des grandes surfaces de friction sont associées à une augmentation de l'usure du polyéthylène (8). En revanche, les données sur la cinématique et l'usure, in vivo, de ce type d'implant étaient jusqu'alors limitées. Depuis quelques années, un certain nombre d'études cliniques avec un follow up significatif ont été publiées. CONCLUSIONS ET PERSPECTIVES FUTURES La prothèse totale de hanche à double mobilité, développée par Bousquet dans les années 1970, est un concept novateur dans l'arthroplastie totale de hanche. Depuis sa première conception, de nombreuses améliorations ont été adoptées. Cependant, ses effets à long terme sur la survie de l'implant doivent encore être effectué. Certes, des études ont montré un net effet sur la réduction du taux de luxation des prothèses primaires, lors de révision ou après résection tumorale. Toutefois, compte tenu des données limitées à long terme sur le taux d'usure et le descellement aseptique, il convient d'utiliser ce type d'implant avec prudence, en particulier lors d'arthroplastie primaire chez des patients jeunes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reconstruction of defects in the craniomaxillofacial (CMF) area has mainly been based on bone grafts or metallic fixing plates and screws. Particularly in the case of large calvarial and/or craniofacial defects caused by trauma, tumours or congenital malformations, there is a need for reliable reconstruction biomaterials, because bone grafts or metallic fixing systems do not completely fulfill the criteria for the best possible reconstruction methods in these complicated cases. In this series of studies, the usability of fibre-reinforced composite (FRC) was studied as a biostable, nonmetallic alternative material for reconstructing artificially created bone defects in frontal and calvarial areas of rabbits. The experimental part of this work describes the different stages of the product development process from the first in vitro tests with resin-impregnated fibrereinforced composites to the in vivo animal studies, in which this FRC was tested as an implant material for reconstructing different size bone defects in rabbit frontal and calvarial areas. In the first in vitro study, the FRC was polymerised in contact with bone or blood in the laboratory. The polymerised FRC samples were then incubated in water, which was analysed for residual monomer content by using high performance liquid chromatography (HPLC). It was found that this in vitro polymerisation in contact with bone and blood did not markedly increase the residual monomer leaching from the FRC. In the second in vitro study, different adhesive systems were tested in fixing the implant to bone surface. This was done to find an alternative implant fixing system to screws and pins. On the basis of this study, it was found that the surface of the calvarial bone needed both mechanical and chemical treatments before the resinimpregnated FRC could be properly fixed onto it. In three animal studies performed with rabbit frontal bone defects and critical size calvarial bone defect models, biological responses to the FRC implants were evaluated. On the basis of theseevaluations, it can be concluded that the FRC, based on E-glass (electrical glass) fibres forming a porous fibre veil enables the ingrowth of connective tissues to the inner structures of the material, as well as the bone formation and mineralization inside the fibre veil. Bone formation could be enhanced by using bioactive glass granules fixed to the FRC implants. FRC-implanted bone defects healed partly; no total healing of defects was achieved. Biological responses during the follow-up time, at a maximum of 12 weeks, to resin-impregnated composite implant seemed to depend on the polymerization time of the resin matrix of the FRC. Both of the studied resin systems used in the FRC were photopolymerised and the heat-induced postpolymerisation was used additionally.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the clinical outcome of patients who received a Baerveldt implant for refractory glaucoma and to identify factors which may influence the outcome. METHODS: Retrospective study including 51 eyes of 51 patients with medically uncontrolled glaucoma who underwent Baerveldt implant surgery between June 1994 and December 1998. Criteria for success were intraocular pressure (IOP) < or = 21 mmHg and > 6 mmHg, necessity of further antiglaucoma medications, absence of additional glaucoma surgery and no loss of light perception. RESULTS: Over a mean follow-up of 37.6 (SD: +/-18.8) months, the mean intraocular pressure decreased from 34.8 (+/-12.5) mmHg to 14.0 (+/-4.3) mmHg at month 60. Qualified success rate, achieved when IOP was below 21 mmHg and higher than 6 mmHg with medications was 25/48 (52%), complete success rate (same IOP limits without medication) was 14/48 (29%). Seven eyes had major complications or lost light perception. Postoperative visual acuity improved or remained within one Snellen line of the preoperative visual acuity in 35 patients (73%). Factors associated with a better prognosis were a preoperative visual acuity better than 20/400 and etiology of glaucoma. CONCLUSION: The Baerveldt implant is effective in lowering intraocular pressure in most patients with refractory glaucoma. Long-term results are promising with satisfactory IOP control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fractures of the proximal femur are common in the elderly population. Intramedullary nailing has become the standard treatment for intertrochanteric fractures although several extramedullary implants (e.g. dynamic hip screw (DHS), blade plate, locking compression plate (LCP), etc.) exist. However, despite this being a very common operation in traumatology, there are numerous associated complications. We report the rare complication of the migration of the medial lag screw into the pelvis at five and a half weeks postoperatively. The implant was removed and replaced by a total hip arthroplasty with simultaneous grafting of the acetabular defect and strapping of the greater trochanter. The evolution was favourable. We also present a review of the literature and analyze our case.