976 resultados para EIC,SiPM,dRICH,silicon photomultiplier


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pyro and hydrometallurgical processes were applied to the treatment of spent commercial zeolites (a molecular sieve and a ZSM-5 sample). Both catalysts were employed in pilot plant units. They were kept in their original shape, they were not regenerated and were not subjected neither to mechanical stress nor to overheating zones during their time on-stream. Two recycling processes were tested: (i) direct solubilization of samples in mixtures of HF + H2O2 (60 ºC, 1 h). Although silicon was solubilized, insoluble matter was found in both samples, particularly in the molecular sieve, due to its high amounts of alkaline and alkaline-earth metals; (ii) fusion with KHSO4 (5 h, 600 ºC) with KHSO4/zeolite mass ratio 6:1. After fusion the solid was solubilized in water (100 ºC), leaving silicon as SiO2 residue. In both processes, solubilized metals were isolated by conventional selective precipitation techniques. Analysis of final products by common analytical methods shows that metals present in the original catalysts were recovered with very high yields except when the molecular sieve was treated with HF + H2O2. This reactant mixture proved to be suitable for processing zeolites with a low alkaline and alkaline-earth metal content whereas fusion with KHSO4 appeared to be adequate for all types of zeolites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present work was to test the combination of non-esterified fatty acid (NEFA) isolation using fumed silicon dioxide with capillary gas-chromatography (C-GC) with splitless injection for the analysis of NEFAs in human plasma. Injection volume, solvent re-condensation and split purge flow-rate were the parameters evaluated for the analysis of fatty acid methyl esters by C-GC. The use of a solvent re-condensation technique, associated with 1.0 µL injection and a split purge flow rate of 80 mL/min resulted in satisfactory analysis of NEFAs. Fourteen fatty acids were identified in plasma samples, ranging from 2.03 to 184.0 µmol/L. The combination of both techniques proved useful for routine analyses of plasma NEFAs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Interlaboratorial programs are conducted for a number of purposes: to identify problems related to the calibration of instruments, to assess the degree of equivalence of analytical results among several laboratories, to attribute quantity values and its uncertainties in the development of a certified reference material and to verify the performance of laboratories as in proficiency testing, a key quality assurance technique, which is sometimes used in conjunction with accreditation. Several statistics tools are employed to assess the analytical results of laboratories participating in an intercomparison program. Among them are the z-score technique, the elypse of confidence and the Grubbs and Cochran test. This work presents the experience in coordinating an intercomparison exercise in order to determine Ca, Al, Fe, Ti and Mn, as impurities in samples of silicon metal of chemical grade prepared as a candidate for reference material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

From the perspective of the uncertainties in chemical measurements all uncertainty sources should be part of the uncertainty of the reference material. When the primary methods are not available, interlaboratorial comparisons are used as a means of certification. The material to be distributed to the laboratories should have its homogeneity confirmed. The uncertainty due to this factor will be added to the characterization uncertainty. This work presents a homogeneity study of a lot of silicon metal of chemical degree where the uncertainty due to inhomogeneity is obtained using analysis of variance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was developed with a soil contaminated by heavy metals, with the purpose of evaluating the action of silicon and phosphorus as protection agents through simple extractions by DTPA. The collected samples were prepared and incubated with five doses of silicon and five doses of phosphorus, with four replicates, amounting to 100 experimental units. After 30 and 60 days, samples of each treatment were collected, submitted to pH analyses and simple extraction by DTPA. The amounts of DTPA-extracted metals depended on the doses of silicon and phosphorus and on the pH. Treatments with silicon and phosphorus was efficient in decreasing the availability of heavy metals in soil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes a process for metal recovery from spent NiMo and CoMo/Al2O3 commercial hydrorefining catalysts. The samples were treated by fusion with potassium hydrogen sulfate (5 h, 600 ºC) with a KHSO4/catalyst mass ratio of 10:1. After fusion the solid was solubilized in water (100 ºC), leaving silicon compounds as residue. Losses of nickel and cobalt may reach 16 wt% of the amount present in the sample, depending on the silicon content. Soluble metals were isolated by selective precipitation techniques (nickel, cobalt, aluminum) or by solvent extraction with methyl-isobutyl ketone (molybdenum) in a hydrochloric acid medium. All metals were recovered in very good yields except for nickel and cobalt in the presence of considerable amounts of silicon. Soluble wastes consist of potassium/sodium sulfates/chlorides. Solid wastes correspond to about 4 wt% of the catalyst and can be discarded in industrial dumps.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En este trabajo se investiga la síntesis de estructuras SiC/Si mediante implantación iónica de carbono en Si. Las implantaciones se han realizado a energías entre 25 y 300 keV y las dosis en el rango lO^^ylO^^ cm , manteniendo el substrato a temperatura ambiente o 500°C. Algunas estructuras han sido recocidas a 1150°C. Los resultados indican que implantando a temperatura ambiente se forma una capa de SiC amorfa y de composición gradual, que recristaliza formando precipitados de ß-SiC con orientaciones aleatorias después del recocido. Además se forma un capa superficial rica en carbono, debida a la difusión del carbono hacia la superficie durante la implantación, y que desaparece con el recocido. Implantando a 500°C se forma directamente una capa con una muy alta densidad de precipitados de ß-SiC orientados preferencialmente con la matriz de silicio. Dada la estabilidad térmica y química de dicha capa se han realizado membranas de SiC mediante técnicas fotolitográficas y ataque químico selectivo, cuya rugosidad superficial es inferior a 6 nm. Estas membranas muestran unos gradientes de tensiones residuales, que prácticamente desaparecen después del recocido. Los resultados confirman la potencialidad de la implantación iónica para la formación de estructuras microme-cánicas de SiC sobre Si.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The process of hydrogen desorption from amorphous silicon (ɑ-Si) nanoparticles grown by plasmaenhanced chemical vapor deposition (PECVD) has been analyzed by differential scanning calorimetry (DSC), mass spectrometry, and infrared spectroscopy, with the aim of quantifying the energy exchanged. Two exothermic peaks centered at 330 and 410 °C have been detected with energies per H atom of about 50 meV. This value has been compared with the results of theoretical calculations and is found to agree with the dissociation energy of Si-H groups of about 3.25 eV per H atom, provided that the formation energy per dangling bond in ɑ-Si is about 1.15 eV. It is shown that this result is valid for ɑ-Si:H films, too

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The contamination level of silicon oil used as insulation liquid in high-voltage transformers by ascarel (PCBs) is above those permitted by the Brazilian law. Thus new techniques able to detect ascarel, with low operational costs, are very attractive. The present work proposes an analysis of the contamination levels of silicon oil using the following techniques: naphthalene anion radical reaction for ascarel dechlorination; and potentiometry with an ion-selective electrode for chloride ion determination. The data obtained with the proposed methodology agree well with those from the official methodology, (method IEC 61619).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For the construction of the phase diagrams, the method of the aqueous titration was used. There were prepared 5 ternary diagrams, varying the surfactant and the oil phase. The liquid-crystalline phases were identified by polarized light microscopy. The formulations prepared with silicon glycol copolymer, polyether functional siloxane (PFS) and water (S1) and with diisopropyl adipate, PFS and water (S4) presented liquid-crystalline phases with lamellar arrangement. Moreover, after 15 days in hot oven (37 ºC), the formulations presented hexagonal arrangement, evidencing the influence of the temperature in the organization of the system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Offretite T zeolite was synthesized using different source of Si (Ludox AS-30, Ludox LS-30 and Aerosil 200 Degussa). The obtained materials were characterized by different complementary techniques: XRD, textural analysis by N2 adsorption, IV, SEM and chemistry analysis. This zeolite has an intermediary structure between offretite and erionite zeolites. In all experiments offretite T phase was obtained. Offretite phase presenting better crystalility are obtained in synthesis with stirring and employing aerosil as silicon source. This zeolite presents a potencial application as catalyst for hydroisodewaxing process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intralaboratorial and interlaboratorial variabilities can be obtained by conducting an specially designed interlaboratory program. Using the analysis of variance technique one can calculate the r (repeatability) and R (reproducibility) indexes that can help participant laboratories to monitor their routine quality control procedures. An example is described using data obtained from an interlaboratory program where twelve laboratories determined total iron content in silicon metal sample by using flame atomic absorption spectrometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dendrochemistry is based on the determination of elements retained in tree rings, which can be useful to characterize environmental occurrences. This work shows elemental mappings obtained by EDXRF of the cross section of a tree stem. The tree is originated from a polluted area in Campinas, São Paulo. Some profiles, as the sulfur one, show variations that can be attributed to external contributions, whereas the silicon one can be inferred to a protection defense natural mechanism. Besides being simultaneous and multielementar, the main advantages here are its performance through a non-destructive sample treatment and the ease of operation of XRF equipments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Basic sodalite was successfully synthesized by hydrothermal method using kaolin waste as source of Aluminum and Silicon. This waste is mainly composed by kaolinite and is produced in large amount by kaolin processing industries for paper coating from the Amazon region. Initially, the waste has been calcined at 700 ºC for 2 h and then reacted with the following solutions: Na2CO3 and mixture of Na2CO3 + NaOH to 150 ºC with autogenous pressure for 24 h. The raw materials and transformed materials were characterized by XRD, FTIR and SEM. In both studied media, well-crystallized, basic sodalite was the only phase synthesized, while in the literature usually a mixture of zeolites is obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this work is the development and validation of an analytical method for fast quantification of sibutramine in pharmaceutical formulations, using diffuse reflectance infrared spectroscopy and partial least square regression. The multivariate model was elaborated from 22 mixtures containing sibutramine and excipients (lactose, microcrystalline cellulose, colloidal silicon dioxide and magnesium stearate) and using fragmented (750-1150/ 1350-1500/ 1850-1950/ 2600-2900 cm-1) and smoothing spectral data. Using 10 latent variables, excellent predictive capacity were observed in the calibration (n=20, RMSEC=0.004, R= 0.999) and external validation (n=5, RMSEC= 9.36, R=0.999) phases. In the analysis of synthetic mixtures the precision (SD=3,47%) was compatible with the rules of the Agencia Nacional de Vigilância Sanitária (ANVISA-Brazil). In the analysis of commercial drugs good agreement was observed between spectroscopic and chromatographic methods.