981 resultados para Diet therapy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose
Recent in vitro results have shown significant contributions to cell killing from signaling effects at doses that are typically used in radiation therapy. This study investigates whether these in vitro observations can be reconciled with in vivo knowledge and how signaling may have an impact on future developments in radiation therapy.
Methods and Materials
Prostate cancer treatment plans were generated for a series of 10 patients using 3-dimensional conformal therapy, intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy techniques. These plans were evaluated using mathematical models of survival following modulated radiation exposures that were developed from in vitro observations and incorporate the effects of intercellular signaling. The impact on dose-volume histograms and mean doses were evaluated by converting these survival levels into "signaling-adjusted doses" for comparison.
Results
Inclusion of intercellular communication leads to significant differences between the signalling-adjusted and physical doses across a large volume. Organs in low-dose regions near target volumes see the largest increases, with mean signaling-adjusted bladder doses increasing from 23 to 33 Gy in IMRT plans. By contrast, in high-dose regions, there is a small decrease in signaling-adjusted dose due to reduced contributions from neighboring cells, with planning target volume mean doses falling from 74 to 71 Gy in IMRT. Overall, however, the dose distributions remain broadly similar, and comparisons between the treatment modalities are largely unchanged whether physical or signaling-adjusted dose is compared. Conclusions Although incorporating cellular signaling significantly affects cell killing in low-dose regions and suggests a different interpretation for many phenomena, their effect in high-dose regions for typical planning techniques is comparatively small. This indicates that the significant signaling effects observed in vitro are not contradicted by comparison with clinical observations. Future investigations are needed to validate these effects in vivo and to quantify their ranges and potential impact on more advanced radiation therapy techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The dose delivery accuracy of 30 clinical step and shoot intensity modulated radiation therapy plans was investigated using the single integrated multileaf collimator controller of the Varian Truebeam linear accelerator (linac) (Varian Medical Systems, Palo Alto, CA) and compared with the dose delivery accuracy on a previous generation Varian 2100CD C-Series linac.

Methods and Materials: Ten prostate, 10 prostate and pelvic node, and 10 head-and-neck cases were investigated in this study. Dose delivery accuracy on each linac was assessed using Farmer ionization chamber point dose measurements, 2-dimensional planar ionization chamber array measurements, and the corresponding Varian dynamic log files. Absolute point dose measurements, fluence delivery accuracy, leaf position accuracy, and the overshoot effect were assessed for each plan.

Results: Absolute point dose delivery accuracy increased by 1.5% on the Truebeam compared with the 2100CD linac. No improvement in fluence delivery accuracy between the linacs, at a gamma criterion of 3%/3 mm was measured using the 2-dimensional ionization chamber array, with median (interquartile range) gamma passing rates of 98.99% (97.70%-99.72%) and 99.28% (98.26%-99.75%) for the Truebeam and 2100CD linacs, respectively. Varian log files also showed no improvement in fluence delivery between the linacs at 3%/3 mm, with median gamma passing rates of 99.97% (99.93%-99.99%) and 99.98% (99.94%-100%) for the Truebeam and 2100CD linacs, respectively. However, log files revealed improved leaf position accuracy and fluence delivery at 1%/1 mm criterion on the Truebeam (99.87%; 99.78%-99.94%) compared with the 2100CD linac (97.87%; 91.93%-99.49%). The overshoot effect, characterized on the 2100CD linac, was not observed on the Truebeam.

Conclusions: The integrated multileaf collimator controller on the Varian Truebeam improves clinical treatment delivery accuracy of step and shoot intensity modulated radiation therapy fields compared with delivery on a Varian C-series linac. © 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this work was to determine if volumetric modulated arc therapy (VMAT) plans, created for constant dose-rate (cdrVMAT) delivery are a viable alternative to step and shoot five-field intensity modulated radiation therapy (IMRT). Materials and methods: The cdrVMAT plans, inverse planned on a treatment planning system with no solution to account for couch top or rails, were created for delivery on a linear accelerator with no variable dose rate control system. A series of five-field IMRT and cdrVMAT plans were created using dual partial arcs (gantry rotating between 260° and 100°) with 4° control points for ten prostate patients with the average rectal constraint incrementally increased. Pareto fronts were compared for the planning target volume homogeneity and average rectal dose between the two techniques for each patient. Also investigated were tumour control probability and normal tissue complication probability values for each technique. The delivery parameters [monitor units (MU) and time] and delivery accuracy of the IMRT and VMAT plans were also compared. Results: Pareto fronts showed that the dual partial arc plans were superior to the five-field IMRT plans, particularly for the clinically acceptable plans where average rectal doses were less for rotational plans (p = 0·009) with no statistical difference in target homogeneity. The cdrVMAT plans had significantly more MU (p = 0·005) but the average delivery time was significantly less than the IMRT plans by 42%. All clinically acceptable cdrVMAT plans were accurate in their delivery (gamma 99·2 ± 1·1%, 3%3 mm criteria). Conclusions Accurate delivery of dual partial arc cdrVMAT avoiding the couch top and rails has been demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary Cardiovascular disease (CVD) is a major cause of morbidity and mortality in the Western world in older people. Diet and lifestyle change can reduce CVD risk in older people, and this evidence base is reviewed. For example, diets low in trans fats can reduce CVD risk, while for saturated fats the CVD-lowering effect depends on what is substituted for the saturated fat. Diets rich in fish reduce CVD risk, although n-3 supplements have not been shown to have a consistent effect on CVD end-points. Antioxidant and B-group vitamin supplementation are unlikely to reduce CVD risk, but diets rich in these micronutrients (e.g. rich in fruits and vegetables and the Mediterranean diet) are associated with lower CVD risk, while, for the Mediterranean diet, this has been supported by randomized controlled trials. Maintaining a healthy weight and being physically active reduce CVD risk factors and CVD incidence and mortality. © 2013 Cambridge University Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous revascularization of the renal arteries improves patency in atherosclerotic renovascular disease, yet evidence of a clinical benefit is limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Galactosemia is an inherited metabolic disease in which galactose is not properly metabolised. There are various theories to explain the molecular pathology, and recent experimental evidence strongly suggests that oxidative stress plays a key role. High galactose diets are damaging to experimental animals and oxidative stress also plays a role in this toxicity which can be alleviated by purple sweet potato colour (PSPC). This plant extract is rich in acetylated anthocyanins which have been shown to quench free radical production. The objective of this Commentary is to advance the hypothesis that PSPC, or compounds therefrom, may be a viable basis for a novel therapy for galactosemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cognitive decline has a profound impact on the health and quality of life of older people and their caregivers. Exploring mechanisms to delay cognitive decline has become an urgent economic priority, given the projected changes in population demographics. Systematic reviews and meta-analyses of observational studies suggest that adherence to a Mediterranean Diet (MD) is associated with reduced cognitive decline, but such an observation needs to be tested in randomised controlled trials. Intervention evidence is currently limited, and future studies need to be adequately powered, with careful attention given to choice of participants, outcomes being assessed, study duration and strategies to achieve compliance. Alongside these studies, consideration has to be given to how best promote and encourage dietary change in older people in general, and particularly in those experiencing the early stages of cognitive decline, as there may be specific factors that need to be considered when designing lifestyle behaviour change interventions in this group.