943 resultados para DC system efficiency


Relevância:

30.00% 30.00%

Publicador:

Resumo:

From a manufacturing perspective, the efficiency of manufacturing operations (such as process planning and production scheduling) are the key element for enhancing manufacturing competence. Process planning and production scheduling functions have been traditionally treated as two separate activities, and have resulted in a range of inefficiencies. These include infeasible process plans, non-available/overloaded resources, high production costs, long production lead times, and so on. Above all, it is unlikely that the dynamic changes can be efficiently dealt with. Despite much research has been conducted to integrate process planning and production scheduling to generate optimised solutions to improve manufacturing efficiency, there is still a gap to achieve the competence required for the current global competitive market. In this research, the concept of multi-agent system (MAS) is adopted as a means to address the aforementioned gap. A MAS consists of a collection of intelligent autonomous agents able to solve complex problems. These agents possess their individual objectives and interact with each other to fulfil the global goal. This paper describes a novel use of an autonomous agent system to facilitate the integration of process planning and production scheduling functions to cope with unpredictable demands, in terms of uncertainties in product mix and demand pattern. The novelty lies with the currency-based iterative agent bidding mechanism to allow process planning and production scheduling options to be evaluated simultaneously, so as to search for an optimised, cost-effective solution. This agent based system aims to achieve manufacturing competence by means of enhancing the flexibility and agility of manufacturing enterprises.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of Diagnosis Related Groups (DRG) as a mechanism for hospital financing is a currently debated topic in Portugal. The DRG system was scheduled to be initiated by the Health Ministry of Portugal on January 1, 1990 as an instrument for the allocation of public hospital budgets funded by the National Health Service (NHS), and as a method of payment for other third party payers (e.g., Public Employees (ADSE), private insurers, etc.). Based on experience from other countries such as the United States, it was expected that implementation of this system would result in more efficient hospital resource utilisation and a more equitable distribution of hospital budgets. However, in order to minimise the potentially adverse financial impact on hospitals, the Portuguese Health Ministry decided to gradually phase in the use of the DRG system for budget allocation by using blended hospitalspecific and national DRG casemix rates. Since implementation in 1990, the percentage of each hospitals budget based on hospital specific costs was to decrease, while the percentage based on DRG casemix was to increase. This was scheduled to continue until 1995 when the plan called for allocating yearly budgets on a 50% national and 50% hospitalspecific cost basis. While all other nonNHS third party payers are currently paying based on DRGs, the adoption of DRG casemix as a National Health Service budget setting tool has been slower than anticipated. There is now some argument in both the political and academic communities as to the appropriateness of DRGs as a budget setting criterion as well as to their impact on hospital efficiency in Portugal. This paper uses a twostage procedure to assess the impact of actual DRG payment on the productivity (through its components, i.e., technological change and technical efficiency change) of diagnostic technology in Portuguese hospitals during the years 1992–1994, using both parametric and nonparametric frontier models. We find evidence that the DRG payment system does appear to have had a positive impact on productivity and technical efficiency of some commonly employed diagnostic technologies in Portugal during this time span.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ultimate aim of this project was to design new biomaterials which will improve the efficiency of ocular drug delivery systems. Initially, it was necessary to review the information available on the nature of the tear fluid and its relationship with the eye. An extensive survey of the relevant literature was made. There is a common belief in the literature that the ocular glycoprotein, mucin, plays an important role in tear film stability, and furthermore, that it exists as an adherent layer covering the corneal surface. If this belief is true, the muco-corneal interaction provides the ideal basis for the development of sustained release drug delivery. Preliminary investigations were made to assess the ability of mucin to adhere to polymer surfaces. The intention was to develop a synthetic model which would mimic the supposed corneal/mucin interaction. Analytical procedures included the use of microscopy (phase contrast and fluorescence), fluorophotometry, and mucin-staining dyes. Additionally, the physical properties of tears and tear models were assessed under conditions mimicking those of the preocular environment, using rheological and tensiometric techniques. The wetting abilities of these tear models and opthalmic formulations were also investigated. Tissue culture techniques were employed to enable the surface properties of the corneal surface to be studied by means of cultured corneal cells. The results of these investigations enabled the calculation of interfacial and surface characteristics of tears, tear models, and the corneal surface. Over all, this work cast doubt on the accepted relationship of mucin with the cornea. A corneal surface model was designed, on the basis of the information obtained during this project, which would possess similar surface chemical properties (i.e. would be biomimetic) to the more complex original. This model, together with the information gained on the properties of tears and solutions intended for ocular instillation, could be valuable in the design of drug formulations with enhanced ocular retention times. Furthermore, the model itself may form the basis for the design of an effective drug-carrier.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The suitability of a new plastic supporting medium for biofiltration was tested over a three year period. Tests were carried out on the stability, surface properties, mechanical strength, and dimensions of the medium. There was no evidence to suggest that the medium was deficient in any of these respects. The specific surface (320m2m-3) and the voidage (94%) of the new medium are unlike any other used in bio-filtration and a pilot plant containing two filters was built to observe its effects on ecology and performance. Performance was estimated by chemical analysis and ecology studied by film examination and fauna counts. A system of removable sampling baskets was designed to enable samples to be obtained from two intermediate depths of filter. One of the major operating problems of percolating filters is excessive accumulation of film. The amount of film is influenced by hydraulic and organic load and each filter was run at a different loading. One was operated at 1.2m3m-3day-1 (DOD load 0.24kgm-3day-1) judged at the time to be the lowest filtration rate to offer advantages over conventional media. The other filter was operated at more than twice this loading (2.4m3m-3day-lBOD load 0.55kgm-3day-1) giving a roughly 2.5x and 6x the conventional loadings recommended for a Royal Commission effluent. The amount of film in each filter was normally low (0.05-3kgm(3 as volatile solids) and did not affect efficiency. The evidence collected during the study indicated that the ecology of the filters was normal when compared with the data obtained from the literature relating to filters with mineral media. There were indications that full ecological stability was yet to be reached and this was affecting the efficiency of the filters. The lower rate filter produced an average 87% BOD removal giving a consistent Royal Commission effluent during the summer months. The higher rate filter produced a mean 83% BOD removal but at no stage a consistent Royal Commission effluent. From the data on ecology and performance the filters resembled conventional filters rather than high rate filters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computer-Based Learning systems of one sort or another have been in existence for almost 20 years, but they have yet to achieve real credibility within Commerce, Industry or Education. A variety of reasons could be postulated for this, typically: - cost - complexity - inefficiency - inflexibility - tedium Obviously different systems deserve different levels and types of criticism, but it still remains true that Computer-Based Learning (CBL) is falling significantly short of its potential. Experience of a small, but highly successful CBL system within a large, geographically distributed industry (the National Coal Board) prompted an investigation into currently available packages, the original intention being to purchase the most suitable software and run it on existing computer hardware, alongside existing software systems. It became apparent that none of the available CBL packages were suitable, and a decision was taken to develop an in-house Computer-Assisted Instruction system according to the following criteria: - cheap to run; - easy to author course material; - easy to use; - requires no computing knowledge to use (as either an author or student) ; - efficient in the use of computer resources; - has a comprehensive range of facilities at all levels. This thesis describes the initial investigation, resultant observations and the design, development and implementation of the SCHOOL system. One of the principal characteristics c£ SCHOOL is that it uses a hierarchical database structure for the storage of course material - thereby providing inherently a great deal of the power, flexibility and efficiency originally required. Trials using the SCHOOL system on IBM 303X series equipment are also detailed, along with proposed and current development work on what is essentially an operational CBL system within a large-scale Industrial environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis reports the development of a reliable method for the prediction of response to electromagnetically induced vibration in large electric machines. The machines of primary interest are DC ship-propulsion motors but much of the work reported has broader significance. The investigation has involved work in five principal areas. (1) The development and use of dynamic substructuring methods. (2) The development of special elements to represent individual machine components. (3) Laboratory scale investigations to establish empirical values for properties which affect machine vibration levels. (4) Experiments on machines on the factory test-bed to provide data for correlation with prediction. (5) Reasoning with regard to the effect of various design features. The limiting factor in producing good models for machines in vibration is the time required for an analysis to take place. Dynamic substructuring methods were adopted early in the project to maximise the efficiency of the analysis. A review of existing substructure- representation and composite-structure assembly methods includes comments on which are most suitable for this application. In three appendices to the main volume methods are presented which were developed by the author to accelerate analyses. Despite significant advances in this area, the limiting factor in machine analyses is still time. The representation of individual machine components was addressed as another means by which the time required for an analysis could be reduced. This has resulted in the development of special elements which are more efficient than their finite-element counterparts. The laboratory scale experiments reported were undertaken to establish empirical values for the properties of three distinct features - lamination stacks, bolted-flange joints in rings and cylinders and the shimmed pole-yoke joint. These are central to the preparation of an accurate machine model. The theoretical methods are tested numerically and correlated with tests on two machines (running and static). A system has been devised with which the general electromagnetic forcing may be split into its most fundamental components. This is used to draw some conclusions about the probable effects of various design features.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A study on heat pump thermodynamic characteristics has been made in the laboratory on a specially designed and instrumented air to water heat pump system. The design, using refrigerant R12, was based on the requirement to produce domestic hot water at a temperature of about 50 °C and was assembled in the laboratory. All the experimental data were fed to a microcomputer and stored on disk automatically from appropriate transducers via amplifier and 16 channel analogue to digital converters. The measurements taken were R12 pressures and temperatures, water and R12 mass flow rates, air speed, fan and compressor input powers, water and air inlet and outlet temperatures, wet and dry bulb temperatures. The time interval between the observations could be varied. The results showed, as expected, that the COP was higher at higher air inlet temperatures and at lower hot water output temperatures. The optimum air speed was found to be at a speed when the fan input power was about 4% of the condenser heat output. It was also found that the hot water can be produced at a temperature higher than the appropriate R12 condensing temperature corresponding to condensing pressure. This was achieved by condenser design to take advantage of discharge superheat and by further heating the water using heat recovery from the compressor. Of the input power to the compressor, typically about 85% was transferred to the refrigerant, 50 % by the compression work and 35% due to the heating of the refrigerant by the cylinder wall, and the remaining 15% (of the input power) was rejected to the cooling medium. The evaporator effectiveness was found to be about 75% and sensitive to the air speed. Using the data collected, a steady state computer model was developed. For given input conditions s air inlet temperature, air speed, the degree of suction superheat , water inlet and outlet temperatures; the model is capable of predicting the refrigerant cycle, compressor efficiency, evaporator effectiveness, condenser water flow rate and system Cop.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Faced with a future of rising energy costs there is a need for industry to manage energy more carefully in order to meet its economic objectives. A problem besetting the growth of energy conservation in the UK is that a large proportion of energy consumption is used in a low intensive manner in organisations where they would be responsibility for energy efficiency is spread over a large number of personnel who each see only small energy costs. In relation to this problem in the non-energy intensive industrial sector, an application of an energy management technique known as monitoring and targeting (M & T) has been installed at the Whetstone site of the General Electric Company Limited in an attempt to prove it as a means for motivating line management and personnel to save energy. The objective energy saving for which the M & T was devised is very specific. During early energy conservation work at the site there had been a change from continuous to intermittent heating but the maintenance of the strategy was receiving a poor level of commitment from line management and performance was some 5% - 10% less than expected. The M & T is concerned therefore with heat for space heating for which a heat metering system was required. Metering of the site high pressure hot water system posed technical difficulties and expenditure was also limited. This led to a ‘tin-house' design being installed for a price less than the commercial equivalent. The timespan of work to achieve an operational heat metering system was 3 years which meant that energy saving results from the scheme were not observed during the study. If successful the replication potential is the larger non energy intensive sites from which some 30 PT savings could be expected in the UK.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Enhanced immune responses for DNA and subunit vaccines potentiated by surfactant vesicle based delivery systems outlined in the present study, provides proof of principle for the beneficial aspects of vesicle mediated vaccination. The dehydration-rehydration technique was used to entrap plasmid DNA or subunit antigens into lipid-based (liposomes) or non-ionic surfactant-based (niosomes) dehydration-rehydration vesicles (DRV). Using this procedure, it was shown that both these types of antigens can be effectively entrapped in DRV liposomes and DRV niosomes. The vesicle size of DRV niosomes was shown to be twice the diameter (~2µm) of that of their liposome counterparts. Incorporation of cryoprotectants such as sucrose in the DRV procedure resulted in reduced vesicle sizes while retaining high DNA incorporation efficiency (~95%). Transfection studies in COS 7 cells demonstrated that the choice of cationic lipid, the helper lipid, and the method of preparation, all influenced transfection efficiency indicating a strong interdependency of these factors. This phenomenon has been further reinforced when 1,2-dioleoyl-sn-glycero-3-phosphoethanolamine (DOPE): cholesteryl 3b- [N-(N’ ,N’ -dimethylaminoethane)-carbamoyl] cholesterol (DC-Chol)/DNA complexes were supplemented with non-ionic surfactants. Morphological analysis of these complexes using transmission electron microscopy and environmental scanning electron microscopy (ESEM) revealed the presence of heterogeneous structures which may be essential for an efficient transfection in addition to the fusogenic properties of DOPE. In vivo evaluation of these DNA incorporated vesicle systems in BALB/c mice showed weak antibody and cell-mediated immune (CMI) responses. Subsequent mock challenge with hepatitis B antigen demonstrated that, 1-monopalmitoyl glycerol (MP) based DRV, is a more promising DNA vaccine adjuvant. Studying these DRV systems as adjuvants for the Hepatitis B subunit antigen (HBsAg) revealed a balanced antibody/CMI response profile on the basis of the HBsAg specific antibody and cytokine responses which were higher than unadjuvated antigen. The effect of addition of MP, cholesterol and trehalose 6,6’-dibehenate (TDB) on the stability and immuno-efficacy of dimethyldioctadecylammonium bromide (DDA) vesicles was investigated. Differential scanning calorimetry showed a reduction in transition temperature of DDA vesicles by ~12°C when incorporated with surfactants. ESEM of MP based DRV system indicated an increased vesicle stability upon incorporation of antigen. Adjuvant activity of these systems tested in C57BL/6j mice against three subunit antigens i.e., mycobacterial fusion protein- Ag85B-ESAT-6, and two malarial antigens - merozoite surface protein-1, (MSP1), and glutamate rich protein, (GLURP) revealed that while MP and DDA based systems induced comparable antibody responses, DDA based systems induced powerful CMI responses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The immunostimulatory capacities of cationic liposomes are well-documented and are attributed both to inherent immunogenicity of the cationic lipid and more physical capacities such as the formation of antigen depots and antigen delivery. Very few studies have however been conducted comparing the immunostimulatory capacities of different cationic lipids. In the present study we therefore chose to investigate three of the most well-known cationic liposome-forming lipids as potential adjuvants for protein subunit vaccines. The ability of 3ß-[N-(N',N'-dimethylaminoethane)carbomyl] cholesterol (DC-Chol), 1,2-dioleoyl-3-trimethylammonium propane (DOTAP), and dimethyldioctadecylammonium (DDA) liposomes incorporating immunomodulating trehalose dibehenate (TDB) to form an antigen depot at the site of injection (SOI) and to induce immunological recall responses against coadministered tuberculosis vaccine antigen Ag85B-ESAT-6 are reported. Furthermore, physical characterization of the liposomes is presented. Our results suggest that liposome composition plays an important role in vaccine retention at the SOI and the ability to enable the immune system to induce a vaccine specific recall response. While all three cationic liposomes facilitated increased antigen presentation by antigen presenting cells, the monocyte infiltration to the SOI and the production of IFN-? upon antigen recall was markedly higher for DDA and DC-Chol based liposomes which exhibited a longer retention profile at the SOI. A long-term retention and slow release of liposome and vaccine antigen from the injection site hence appears to favor a stronger Th1 immune response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the competitive challenge facing business today, the need to keep cost down and quality up is a matter of survival. One way in which wire manufacturers can meet this challenge is to possess a thorough understanding of deformation, friction and lubrication during the wire drawing process, and therefore to make good decisions regarding the selection and application of lubricants as well as the die design. Friction, lubrication and die design during wire drawing thus become the subject of this study. Although theoretical and experimental investigations have been being carried out ever since the establishment of wire drawing technology, many problems remain unsolved. It is therefore necessary to conduct further research on traditional and fundamental subjects such as the mechanics of deformation, friction, lubrication and die design in wire drawing. Drawing experiments were carried out on an existing bull-block under different cross-sectional area reductions, different speeds and different lubricants. The instrumentation to measure drawing load and drawing speed was set up and connected to the wire drawing machine, together with a data acquisition system. A die box connected to the existing die holder for using dry soap lubricant was designed and tested. The experimental results in terms of drawing stress vs percentage area reduction curves under different drawing conditions were analysed and compared. The effects on drawing stress of friction, lubrication, drawing speed and pressure die nozzle are discussed. In order to determine the flow stress of the material during deformation, tensile tests were performed on an Instron universal test machine, using the wires drawn under different area reductions. A polynomial function is used to correlate the flow stress of the material with the plastic strain, on which a general computer program has been written to find out the coefficients of the stress-strain function. The residual lubricant film on the steel wire after drawing was examined both radially and longitudinally using an SEM and optical microscope. The lubricant film on the drawn wire was clearly observed. Therefore, the micro-analysis by SEM provides a way of friction and lubrication assessment in wire drawing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Desalination of groundwater is essential in arid regions that are remote from both seawater and freshwater resources. Desirable features of a groundwater desalination system include a high recovery ratio, operation from a sustainable energy source such as solar, and high water output per unit of energy and land. Here we propose a new system that uses a solar-Rankine cycle to drive reverse osmosis (RO). The working fluid such as steam is expanded against a power piston that actuates a pump piston which in turn pressurises the saline water thus passing it through RO membranes. A reciprocating crank mechanism is used to equalise the forces between the two pistons. The choice of batch mode in preference to continuous flow permits maximum energy recovery and minimal concentration polarisation in the vicinity of the RO membrane. This study analyses the sizing and efficiency of the crank mechanism, quantifies energy losses in the RO separation and predicts the overall performance. For example, a system using a field of linear Fresnel collectors occupying 1000 m2 of land and raising steam at 200 °C and 15.5 bar could desalinate 350 m3/day from saline water containing 5000 ppm of sodium chloride with a recovery ratio of 0.7.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: We introduced a series of computer-supported workshops in our undergraduate statistics courses, in the hope that it would help students to gain a deeper understanding of statistical concepts. This raised questions about the appropriate design of the Virtual Learning Environment (VLE) in which such an approach had to be implemented. Therefore, we investigated two competing software design models for VLEs. In the first system, all learning features were a function of the classical VLE. The second system was designed from the perspective that learning features should be a function of the course's core content (statistical analyses), which required us to develop a specific-purpose Statistical Learning Environment (SLE) based on Reproducible Computing and newly developed Peer Review (PR) technology. Objectives: The main research question is whether the second VLE design improved learning efficiency as compared to the standard type of VLE design that is commonly used in education. As a secondary objective we provide empirical evidence about the usefulness of PR as a constructivist learning activity which supports non-rote learning. Finally, this paper illustrates that it is possible to introduce a constructivist learning approach in large student populations, based on adequately designed educational technology, without subsuming educational content to technological convenience. Methods: Both VLE systems were tested within a two-year quasi-experiment based on a Reliable Nonequivalent Group Design. This approach allowed us to draw valid conclusions about the treatment effect of the changed VLE design, even though the systems were implemented in successive years. The methodological aspects about the experiment's internal validity are explained extensively. Results: The effect of the design change is shown to have substantially increased the efficiency of constructivist, computer-assisted learning activities for all cohorts of the student population under investigation. The findings demonstrate that a content-based design outperforms the traditional VLE-based design. © 2011 Wessa et al.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The multiterminal dc wind farm is a promising topology with a voltage-source inverter (VSI) connection at the onshore grid. Voltage-source converters (VSCs) are robust to ac-side fault conditions. However, they are vulnerable to dc faults on the dc side of the converter. This paper analyzes dc faults, their transients, and the resulting protection issues. Overcurrent faults are analyzed in detail and provide an insight into protection system design. The radial wind farm topology with star or string connection is considered. The outcomes may be applicable for VSCs in the multi-VSC dc wind farm collection grid and VSC-based high-voltage direct current (HVDC) offshore transmission systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of high-power voltage-source converters (VSCs) to multiterminal dc networks is attracting research interest. The development of VSC-based dc networks is constrained by the lack of operational experience, the immaturity of appropriate protective devices, and the lack of appropriate fault analysis techniques. VSCs are vulnerable to dc-cable short-circuit and ground faults due to the high discharge current from the dc-link capacitance. However, faults occurring along the interconnecting dc cables are most likely to threaten system operation. In this paper, cable faults in VSC-based dc networks are analyzed in detail with the identification and definition of the most serious stages of the fault that need to be avoided. A fault location method is proposed because this is a prerequisite for an effective design of a fault protection scheme. It is demonstrated that it is relatively easy to evaluate the distance to a short-circuit fault using voltage reference comparison. For the more difficult challenge of locating ground faults, a method of estimating both the ground resistance and the distance to the fault is proposed by analyzing the initial stage of the fault transient. Analysis of the proposed method is provided and is based on simulation results, with a range of fault resistances, distances, and operational conditions considered.