968 resultados para Computed tomography, image quality, dose reduction, iterative reconstruction, model observer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulmonary embolism (PE) is traditionally treated in hospital. Growing evidence from non randomized prospective studies suggests that a substantial proportion of patients with non-massive PE might be safely treated in the outpatient setting using low molecular weight heparins. Based on this evidence, professional societies started to recommend outpatient care for selected patients with non-massive PE. Despite these recommendations, outpatient treatment of non-massive PE appears to be uncommon in clinical practice. The major barriers to PE outpatient care are, firstly, the uncertainty as how to identify low risk patients with PE who are candidates for outpatient care and secondly the lack of high quality evidence from randomized trials demonstrating the safety of PE outpatient care compared to traditional inpatient management. Also, although clinical prognostic models, echocardiography and cardiac biomarkers accurately identify low risk patients with PE in prospective studies, the benefit of risk stratification strategies based on these instruments should be demonstrated in prospective management studies and clinical trials before they can be implemented as decision aids to guide PE outpatient treatment. Before high quality evidence documenting the safety of an outpatient treatment approach is published, outpatient management of non-massive PE cannot be generally recommended.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To systematically review and meta-analyze published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the assessment of pleural abnormalities in cancer patients. METHODS: A comprehensive literature search of studies published through June 2013 regarding the role of (18)F-FDG-PET and PET/CT in evaluating pleural abnormalities in cancer patients was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odd ratio (DOR) of (18)F-FDG-PET or PET/CT on a per patient-based analysis were calculated. The area under the summary ROC curve (AUC) was calculated to measure the accuracy of these methods in the assessment of pleural abnormalities. Sub-analyses considering (18)F-FDG-PET/CT and patients with lung cancer only were carried out. RESULTS: Eight studies comprising 360 cancer patients (323 with lung cancer) were included. The meta-analysis of these selected studies provided the following results: sensitivity 86% [95% confidence interval (95%CI): 80-91%], specificity 80% [95%CI: 73-85%], LR+ 3.7 [95%CI: 2.8-4.9], LR- 0.18 [95%CI: 0.09-0.34], DOR 27 [95%CI: 13-56]. The AUC was 0.907. No significant improvement considering PET/CT studies only and patients with lung cancer was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of pleural abnormalities in cancer patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. The literature focusing on the use of (18)F-FDG-PET and PET/CT in this setting remains still limited and prospective studies are needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In locally advanced cervical cancer, (18)F-fluorodeoxyglucose (FDG) positron emission tomography - computed tomography (PET/CT) has become important in the initial evaluation of disease extent. It is superior to other imaging modalities for lymph node status and distant metastasis. PET-defined cervical tumor volume predicts progression-free and overall survival. Higher FDG uptake in both primary and regional lymph nodes is strongly predictive of worse outcome. FDG-PET is useful for assessing treatment response 3 months after completing concurrent chemo-radiotherapy (CRT) and predicting long-term survival, and in suspected disease recurrence. In the era of image-guided adaptive radiotherapy, accurately defining disease areas is critical to avoid irradiating normal tissue. Based on additional information provided by FDG-PET, radiation treatment volumes can be modified and higher doses to FDG-positive lymph nodes safely delivered. FDG-PET/CT has been used for image-guided brachytherapy of FDG-avid tumor volume, while respecting low doses to bladder and rectum. Despite survival improvements due to CRT in cervical cancer, disease recurrences continue to be a major problem. Biological rationale exists for combining novel non-cytotoxic agents with CRT, and drugs targeting specific molecular pathways are under clinical development. The integration of these targeted therapies in clinical trials, and the need for accurate predictors of radio-curability is essential. New molecular imaging tracers may help identifying more aggressive tumors. (64)Cu-labeled diacetyl-di(N(4)-methylthiosemicarbazone) is taken up by hypoxic tissues, which may be valuable for prognostication and radiation treatment planning. PET/CT imaging with novel radiopharmaceuticals could further impact cervical cancer treatment as surrogate markers of drug activity at the tumor microenvironment level. The present article reviews the current and emerging role of PET/CT in the management of cervical cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The objective of this experiment is to establish a continuous postmortem circulation in the vascular system of porcine lungs and to evaluate the pulmonary distribution of the perfusate. This research is performed in the bigger scope of a revascularization project of Thiel embalmed specimens. This technique enables teaching anatomy, practicing surgical procedures and doing research under lifelike circumstances. METHODS: After cannulation of the pulmonary trunk and the left atrium, the vascular system was flushed with paraffinum perliquidum (PP) through a heart-lung machine. A continuous circulation was then established using red PP, during which perfusion parameters were measured. The distribution of contrast-containing PP in the pulmonary circulation was visualized on computed tomography. Finally, the amount of leak from the vascular system was calculated. RESULTS: A reperfusion of the vascular system was initiated for 37 min. The flow rate ranged between 80 and 130 ml/min throughout the experiment with acceptable perfusion pressures (range: 37-78 mm Hg). Computed tomography imaging and 3D reconstruction revealed a diffuse vascular distribution of PP and a decreasing vascularization ratio in cranial direction. A self-limiting leak (i.e. 66.8% of the circulating volume) towards the tracheobronchial tree due to vessel rupture was also measured. CONCLUSIONS: PP enables circulation in an isolated porcine lung model with an acceptable pressure-flow relationship resulting in an excellent recruitment of the vascular system. Despite these promising results, rupture of vessel walls may cause leaks. Further exploration of the perfusion capacities of PP in other organs is necessary. Eventually, this could lead to the development of reperfused Thiel embalmed human bodies, which have several applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on a patient with Marfan syndrome who presented a Stanford type B dissection of the descending thoracic aorta in late pregnancy. After a cesarean section, the patient presented a severe obstruction of the mesenteric superior artery. An endovascular fenestration was performed (balloon and guidewire based fenestration). Computed tomography (CT) angiography revealed an intussusception 'like' image of the abdominal aortic layers as a consequence of the fenestration procedure. Because of aneurismal progression in the abdominal aorta, surgical repair of the abdominal aorta and intussusception material removal was achieved six weeks later. The patient is currently in good condition. We conclude that the intussusception could be induced by a guidewire. This fenestration procedure is not recommended in patients with structural aortic disorders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine dose thresholds, in term of CTDIvol, where subtle anatomical structures of pediatric CT images becomes no more detectable and compare them to the most recent Reference Dose Levels (DRL) proposed in the UK, Germany and Switzerland. Materials and methods: A GE LightSpeed-Ultra scanner (MSCT 8 slices) was used to perform chest and abdomen acquisitions on 8 patients (age range 2 to 16 years old) to provide a set of gold standard images. Dose reductions were then simulated by introducing image noise on raw data to provide simulated CT images with CTDIvol ranging from 2 to 22 mGy. All images were reviewed and scored independently by four experienced radiologists using the VGA methodology (Visual Grading Analysis) to determine the dose threshold where a significant loss of normal anatomy conspicuity appeared. Data were analyzed with ANOVA and Tukey HSD tests, a p >0.05 was considered to be significant. Results: No significant difference in VGA scoring appeared for CTDIvol leading to image noise levels lower than 10 and 25 HU for respectively abdominal and chest acquisitions. These data can thus be used to set the AEC (automatic exposure control) system of units having similar noise properties than the GE LightSpeed-Ultra used in this study. The present DRLs proposed for pediatric CT acquisitions are compatible with an excellent image quality level. Conclusion: The differences of DRL values proposed in Europe for pediatric acquisitions are marginal and assure a very good image quality level. The results of this study allow to further optimize the acquisition protocol by giving Noise Index value to set the AEC device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To review and update the evidence on predictors of poor outcome (death, persistent vegetative state or severe neurological disability) in adult comatose survivors of cardiac arrest, either treated or not treated with controlled temperature, to identify knowledge gaps and to suggest a reliable prognostication strategy. METHODS: GRADE-based systematic review followed by expert consensus achieved using Web-based Delphi methodology, conference calls and face-to-face meetings. Predictors based on clinical examination, electrophysiology, biomarkers and imaging were included. RESULTS AND CONCLUSIONS: Evidence from a total of 73 studies was reviewed. The quality of evidence was low or very low for almost all studies. In patients who are comatose with absent or extensor motor response at ?72h from arrest, either treated or not treated with controlled temperature, bilateral absence of either pupillary and corneal reflexes or N20 wave of short-latency somatosensory evoked potentials were identified as the most robust predictors. Early status myoclonus, elevated values of neuron specific enolase at 48-72h from arrest, unreactive malignant EEG patterns after rewarming, and presence of diffuse signs of postanoxic injury on either computed tomography or magnetic resonance imaging were identified as useful but less robust predictors. Prolonged observation and repeated assessments should be considered when results of initial assessment are inconclusive. Although no specific combination of predictors is sufficiently supported by available evidence, a multimodal prognostication approach is recommended in all patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background/Purpose: Patient-reported outcomes (PROs) in patients with rheumatoid arthritis (RA) are critical in evaluating RA treatment effects on function and health-related quality of life (HR-QoL). Significant improvement in PROs has been reported in RA studies of biologic agents, including etanercept (ETN), but most studies have been conducted in patients with established disease. In addition to assessing treatment effects in early RA, there is interest in therapeutic strategies that allow dose reduction or withdrawal of biologic therapy (biologic-free) after induction of response. The PRIZE trial is an ongoing, 3-period study to evaluate the efficacy of combined ETN and methotrexate (MTX) therapy in patients with early, moderate-to-severe RA and to assess whether efficacy (remission) can be maintained with ETN dose reduction or biologic-free (Period 2) or drug-free (Period 3). Herein we report PROs associated with ETN 50 mg QW plus MTX (ETN50/MTX) therapy administered for 52 wks in Period 1 (induction) of the PRIZE trial. Methods: In Period 1, MTX- and biologic-naı‥ve patients with early, active RA (symptom onset 12 mo from enrollment; DAS28 _3.2) received open-label ETN50/MTX for 52 wks. The starting dose of MTX was 10 mg QW; at the discretion of the investigator, titration was permitted up to a maximum of 25 mg QW to achieve remission. Corticosteroid boosts were administered to patients not achieving low disease state at wks 13 and 26, unless contraindicated or not tolerated. PROs were assessed using the Health Assessment Questionnaire (HAQ) total score; Patient Acceptable Symptom State (PASS); EuroQol-5 Dimensions (EQ-5D) total index; Short Form Health Survey (SF-36); Functional Assessment of Chronic Illness Therapy (FACIT)-Fatigue; Work Instability Scale for Rheumatoid Arthritis (RAWIS); and Work Productivity and Activity Impairment Questionnaire: Rheumatoid Arthritis (WPAI:RA). Results: A total of 306 patients received treatment in Period 1 (mITT population); 222 (73%) patients completed the period. The majority of patients were female (70%), with a mean age of 50 y, mean DAS28 of 6.0 (median, 6.0), and duration of disease symptoms from onset of 6.5 months (median, 6.3 mo). Significant and clinically meaningful improvements in PROs, including in HAQ, EQ-5D, SF-36, and FACIT-Fatigue, were demonstrated with ETN50/MTX therapy from baseline to the final on therapy visit (Table; P_0.0001). Similar improvements were observed in all dimensions of RA-WIS and WPAI:RA (Table; P_0.0001). Conclusion: Combination therapy with ETN50/MTX for 52 wks in patients with _12 mo of symptomatic, active RA resulted in significant, clinically important improvements in measures of physical function, including normal HAQ (66.6% of patients), HR-QoL, fatigue, and work productivity. These outcomes are consistent with those reported in prior studies in patients with more established disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Preoperative imaging for resection of chest wall malignancies is generally performed by computed tomography (CT). We evaluated the role of (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in planning full-thickness chest wall resections for malignancies. We retrospectively included 18 consecutive patients operated from 2004 to 2006 at our institution. Tumor extent was measured by CT and PET, using the two largest perpendicular tumor extensions in the chest wall plane to compute the tumor surface assuming an elliptical shape. Imaging measurements were compared to histopathology assessment of tumor borders. CT assessment consistently overestimated the tumor size as compared to PET (+64% vs. +1%, P<0.001). Moreover, PET was significantly better than CT at defining the size of lesions >24 cm(2) corresponding to a mean diameter >5.5 cm or an ellipse of >4 cm x 7.6 cm (positive predictive value 80% vs. 44% and specificity 93% vs. 64%, respectively). Metabolic PET imaging was superior to CT for defining the extent of chest wall tumors, particularly for tumors with a diameter >5.5 cm. PET can complement CT in planning full-thickness chest wall resection for malignancies, but its true value remains to be determined in larger, prospective studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Intraabdominal adipose tissue (IAAT) is the body fat depot most strongly related to disease risk. Weight reduction is advocated for overweight people to reduce total body fat and IAAT, although little is known about the effect of weight loss on abdominal fat distribution in different races. OBJECTIVE: We compared the effects of diet-induced weight loss on changes in abdominal fat distribution in white and black women. DESIGN: We studied 23 white and 23 black women, similar in age and body composition, in the overweight state [mean body mass index (BMI; in kg/m(2)): 28.8] and the normal-weight state (mean BMI: 24.0) and 38 never-overweight control women (mean BMI: 23.4). We measured total body fat by using a 4-compartment model, trunk fat by using dual-energy X-ray absorptiometry, and cross-sectional areas of IAAT (at the fourth and fifth lumbar vertebrae) and subcutaneous abdominal adipose tissue (SAAT) by using computed tomography. RESULTS: Weight loss was similar in white and black women (13.1 and 12.6 kg, respectively), as were losses of total fat, trunk fat, and waist circumference. However, white women lost more IAAT (P < 0.001) and less SAAT (P < 0.03) than did black women. Fat patterns regressed toward those of their respective control groups. Changes in waist circumference correlated with changes in IAAT in white women (r = 0.54, P < 0.05) but not in black women (r = 0.19, NS). CONCLUSIONS: Despite comparable decreases in total and trunk fat, white women lost more IAAT and less SAAT than did black women. Waist circumference was not a suitable surrogate marker for tracking changes in the visceral fat compartment in black women.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: Nasopalatine duct cysts (NPDCs) are the most common developmental, epithelial and non-odontogenic cysts of the maxillae. The present study describes the clinicopathological characteristics of 22 NPDCs and discusses their etiology, incidence, treatment and prognosis, with a review of the literature on the subject. Study design: A retrospective observational study was made comprising a period of 36 years (1970-2006), and yielding a series of 22 patients with histopathological confirmation of NPDC. Surgical treatment was carried out under local anesthesia and comprised the dissection and removal of the cyst adopting a usually palatine approach, with the preparation of an enveloping flap from 1.4 to 2.4. Results: No statistically significant correlation was observed between the size of the lesion and patient age, although the size of the cyst differed according to patient gender, with a mean NPDC diameter of 16 mm in males and 12 mm in females. In no case did we observe root reabsorption or loss of vitality of the upper incisors following surgery. The X-ray image was rounded in 15 cases and heart-shaped in the remaining 7 cases. In the majority of cases panoramic X-rays and periapical and occlusal X-rays sufficed to identify the lesion, though computed tomography was used in cases of doubt. Conclusions: The etiology of NPDC is unclear. Simple surgical resection is recommended, followed by clinical and radiological control to ensure correct resolution of the case.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To report a single-center experience treating patients with squamous- cell carcinoma of the anal canal using helical Tomotherapy (HT) and concurrent chemotherapy (CT).Materials/Methods: From October 2007 to February 2011, 55 patients were treated with HT and concurrent CT (5-fluorouracil/capecitabin and mitomycin) for anal squamous-cell carcinoma. All patients underwent computed- tomography-based treatment planning, with pelvic and inguinal nodes receiving 36 Gy in 1.8 Gy/fraction. Following a planned 1-week break, primary tumor site and involved nodes were boosted to a total dose 59.4 Gy in 1.8 Gy/fraction. Dose-volume histograms of several organs at risk (OAR; bladder, small intestine, rectum, femoral heads, penile bulb, external genitalia) were assessed in terms of conformal avoidance. All toxicity was scored according to the CTCAE, v.3.0. HT plans and treatment were implemented using the Tomotherapy, Inc. software and hardware. For dosimetric comparisons, 3D RT and/or IMRT plans were also computed for some of the patients using the CMS planning system, for treatment with 6-18 MV photons and/or electrons with suitable energies from a Siemens Primus linear accelerator equipped with a multileaf collimator.Locoregional control and survival curves were compared with the log-rank test, and multivariate analysis by the Cox model.Results: With 360-degree-of-freedom beam projection, HT has an advantage over other RT techniques (3D or 5-field step-and-shot IMRT). There is significant improvement over 3D or 5-field IMRT plans in terms of dose conformity around the PTV, and dose gradients are steeper outside the target volume, resulting in reduced doses to OARs. Using HT, acute toxicity was acceptable, and seemed to be better than historical standards.Conclusions: Our results suggest that HT combined with concurrent CT for anal cancer is effective and tolerable. Compared to 3D RT or 5-field step-andshot IMRT, there is better conformity around the PTV, and better OAR sparing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nationwide surveys on radiation dose to the population from medical radiology are recommended in order to follow the trends in population exposure and ensure radiation protection. The last survey in Switzerland was conducted in 1998, and the annual effective dose from medical radiology was estimated to be 1 mSv y(-1) per capita. The purpose of this work was to follow the trends in diagnostic radiology between 1998 and 2008 in Switzerland and determine the contribution of different modalities and types of examinations to the collective effective dose from medical x-rays. For this reason, an online database (www.raddose.ch) was developed. All healthcare providers who hold a license to run an x-ray unit in the country were invited to participate in the survey. More than 225 examinations, covering eight radiological modalities, were included in the survey. The average effective dose for each examination was reassessed. Data from about 3,500 users were collected (42% response rate). The survey showed that the annual effective dose was 1.2 mSv/capita in 2008. The most frequent examinations are conventional and dental radiographies (88%). The contribution of computed tomography was only 6% in terms of examination frequency but 68% in terms of effective dose. The comparison with other countries showed that the effective dose per capita in Switzerland was in the same range as in other countries with similar healthcare systems, although the annual number of examinations performed in Switzerland was higher.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Leptomeningeal collaterals improve outcome after stroke, including reduction of hemorrhagic complications after thrombolytic or endovascular therapy, smaller infarct size, and reduction in symptoms at follow-up evaluation. The purpose of this study was to determine the demographic and clinical variables that are associated with a greater degree of cerebral collaterals. METHODS: Clinical data of patients presenting with M1 occlusions of the middle cerebral artery (MCA) and associated computed tomography angiography studies after admission from 3 separate institutions were retrospectively compiled (n = 82). Occluded hemispheres were evaluated against the intact hemisphere for degree of collateralization in the MCA territory. Regression analysis of variance was conducted between clinical variables and collateral score to determine which variables associate with greater collateral development. RESULTS: Smaller infarct size corresponded to greater collateral scores, whereas older age and statin use corresponded to lower collateral scores (P < .001). CONCLUSIONS: Cerebral collateralization is influenced by age and statin use and influences infarct size.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Despite dramatic advances in all medical era, cerebral vasospasm is still the major complication in patients with subarachnoid hemorrhage (SAH). The purpose of this study was to assess the influence of intraarterial (IA) nimodipine in the treatment of symptomatic vasospasm and in preventing neurological disabilities. MATERIALS AND METHODS: We retrospectively reviewed 10 patients of SAH who received IA nimodipine in 15 procedures. The decision to perform angiography and endovascular treatment was based on the neurological examination, brain computed tomography (CT) and CT-angiography. The procedure reports, anesthesia records, neurological examination before and after the procedure, brain imaging and short- and long-term outcome were studied. RESULTS: The average dose of nimodipine was 2 mg. The median change in mean arterial pressure at 10 min was -10 mmHg. No significant change of heart rate was observed at 10 min. There was radiological improvement in 80% of the procedures. Neurological improvement was noted after eight out of 12 procedures when nimodipine was used as the sole treatment and after 10 out of 15, overall. Six patients clinically improved after the treatment and had good outcome. In one patient, an embolus caused fatal anterior and middle cerebral arteries infarction. There was no other neurological deficit or radiological abnormality due to the nimodipine treatment itself. CONCLUSION: Low-dose IA nimodipine is a valid adjunct for the endovascular treatment of cerebral vasospasm. Beneficial effects are achieved in some patients, prompting a prospective control study.