969 resultados para CORONARY-BYPASS SURGERY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the use of the intraaortic balloon (IAoB) in association with coronary angioplasty in high-risk patients. METHODS: Fourteen high-risk patients unresponsive to clinical therapy and with formal contraindication to surgical revascularization were treated by coronary angioplasty, most of which was followed by stenting. All procedures were performed with circulatory support with the IAoB. This study reports the early results and the late findings after 12 months of follow-up. Six patients had multivessel coronary disease; of these, four had left main equivalent lesions and two had unprotected left main coronary artery disease, one of whom had severe "end-vessel" stenosis and the other was a patient with Chagas' disease with single-vessel lesion. Eleven patients had a left ventricular ejection fraction <30%. RESULTS: In 100% of the patients, the procedures were initially successful. Two patients had severe bleeding during the withdrawal of the left femoral sheath. At the end of twelve months, 4 patients were asymptomatic and the others were clinically controlled. There were two late deaths in the 7th and 11th months. CONCLUSION: The combined use of the intraaortic balloon pump and percutaneous coronary angioplasty in high-risk patients with acute ischemic syndromes provides the necessary hemodynamic stability to successfully perform the procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 64-year-old female presented with pulmonary edema and cardiogenic shock after coronary arteriography that showed severe suboclusive lesion in the left main coronary artery (LMCA) in a dominant left coronary system. The patient succesfully underwent urgent angioplasty with stent deployment in the LMCA. After an uneventful period, the patient was discharged at day six.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 38-year-old male underwent coronary artery bypass grafting (CABG). A saphenous vein graft was attached to the left marginal branch. The left internal thoracic artery was anastomosed to the left anterior descending artery (LAD). The early recovery was uneventful and the patient was discharged on the 5th postoperative day. After three months, he came back to the hospital complaining of weight loss, weakness, and dyspnea on mild exertion. Chest X-rays showed left pleural effusion. On physical examination, a decreased vesicular murmur was detected. After six days, the diagnosis of chylothorax was made after a milky fluid was detected in the plural cavity and total pulmonary expansion did not occur. On the next day, both anterior and posterior pleural drainage were performed by videothoracoscopy, and prolonged parenteral nutrition (PPN) was instituted for ten days. After seven days the patient was put on a low-fat diet for 8 days. The fluid accumulation ceased, the drains were removed and the patient was discharged with normal pulmonary expansion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A patient with tertiary syphilis presenting with bilateral coronary ostial lesions and aortic regurgitation underwent surgical reconstruction of the coronary ostia by the anterior approach with autogenous saphenous vein grafting and substitution of the aortic valve with a bovine bioprosthesis. The procedure was easily performed and had good outcomes both early and late. The rarity of the association of a lesion in both coronary ostia with aortic regurgitation in syphilis and the surgical technique employed are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report here a case of coronary artery fistula in a neonate with clinical signs of heart failure. The electrocardiogram showed signs of left ventricular hypertrophy and diffuse alterations in ventricular repolarization. Chest X-ray showed an enlargement of the cardiac silhouette with an increase in pulmonary flow. After echocardiographic diagnosis and angiographic confirmation, closure of the fistulous trajectory was performed with a detachable balloon with an early and late successful outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Evaluation of inter and intraobserver reproducibility of by the visual method interpretation of cineangiogram in a clinically based context. METHODS: Five interventional cardiologists analyzed 11 segments of 8 coronary cineangiograms at a two month apart sessions. The percent luminal reduction by the lesions were analyzed by two different classifications: in one (A) the lesions were graded in 0% = absent, 1-50% = mild, 51 - 69 = moderate, and > or = 70% = severe; the other classification (B) was a dichotomic one : <70% = nonsignificant and > or = 70%=significant lesions. The agreement were measured by the kappa (k) index. RESULTS: Interobserver agreement was moderate for classification A (1st measurement, k = 0.36 -- 0.63, k m = 0.49; 2nd measurement, k = 0.39-0.68, k m = 0.52) and good for classification B (1st measurement, k = 0.55-0.73, k m = 0.63; 2nd measurement, k = 0.37-0.82, k m = 0.61). Intraobserver levels of agreement were k = 0.57-0.95 for classification A and 0.62-1.0 for classification B. CONCLUSION: The higher level of reproducibility obtained by adopting the dichotomous criteria usually considered for ischemic limits demonstrates that in the present clinical context, the reliability of the simple visual method is adequate for the identification of patients with clinically significant lesions and candidates for myocardial revascularization procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The best surgical approach for the treatment of patients with severe cerebral artery disease and simultaneous serious coronary artery disease still remains controversial. In this report we present a case of a 72-year-old female patient admitted to the hospital with unstable angina. Triple coronary artery obstructive disease and severe bilateral carotid artery stenosis were diagnosed. A combined, simultaneous surgical procedure was performed. After total circulatory by-pass with a membrane oxygenator, the patient's body temperature was lowered to 32°C. During the cool-down period, three proximal anastomoses of segments of autologous saphenous veins were performed in the ascending aorta. Immediately afterwards, bilateral carotid endarterectomy was performed, followed by three distal anastomoses to coronary arteries. The patient showed a satisfactory post-operative outcome. It was concluded that the combination of moderate hypothermia, hemodilution with appropriate hemodynamic control, as used in this patient, was an effective method of cerebral protection. The simultaneous approach of carotid endarterectomy and coronary artery by-pass surgery should be seen as a safe option for the treatment of this type of patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess safety and efficacy of coronary angioplasty with stent implantation in unstable coronary syndromes. METHODS: Retrospective analysis of in-hospital and late evolution of 74 patients with unstable coronary syndromes (unstable angina or infarction without elevation of the ST segment) undergoing coronary angioplasty with stent placement. These 74 patients were compared with 31 patients with stable coronary syndromes (stable angina or stable silent ischemia) undergoing the same procedure. RESULTS: No death and no need for revascularization of the culprit artery occurred in the in-hospital phase. The incidences of acute non-Q-wave myocardial infarction were 1.4% and 3.2% (p=0.6) in the unstable and stable coronary syndrome groups, respectively. In the late follow-up (11.2±7.5 months), the incidences of these events combined were 5.7% in the unstable coronary syndrome group and 6.9% (p=0.8) in the stable coronary syndrome group. In the multivariate analysis, the only variable with a tendency to significance as an event predictor was diabetes mellitus (p=0.07; OR=5.2; 95% CI=0.9-29.9). CONCLUSION: The in-hospital and late evolutions of patients with unstable coronary syndrome undergoing angioplasty with intracoronary stent implantation are similar to those of the stable coronary syndrome group, suggesting that this procedure is safe and efficacious when performed in unstable coronary syndrome patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary dissection occurs frequently and in several degrees during coronary angioplasty, which is one of the mechanisms for increasing the lumen diameter of a vessel. However the length of the dissection may affect the procedure, becoming the most frequent cause of total occlusion after coronary angioplasty. We report here a case of extensive dissection that occurred during the coronary angioplasty of a focused lesion, which we treated with two long stents.