941 resultados para Biodosimetry errors


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The discharge pulse rates at different magnitude levels are often used as criteria for monitoring the partial-discharge aging of insulation systems. Use of suggested corrections for errors in cumulative probability counting leads to better use of available counters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The shear difference method which is commonly used for the separation of normal stresses using photoelastic techniques depends on the step-by-step integration of one of the differential equations of equilibrium. It is assumed that the isoclinic and the isochromatic parameters measured by the conventional methods pertain to the state of stress at the midpoint of the light path. In practice, a slice thin enough for the above assumption to be true and at the same time thick enough to give differences in the shear-stress values over the thickness is necessary. The paper discusses the errors introduced in the isoclinic and isochromatic values by the conventional methods neglecting the variation of stresses along the light path. It is shown that while the error introduced in the measurement of the isochromatic parameter may not be serious, the error caused in the isoclinic measurement may lead to serious errors. Since the shear-difference method involves step-by-step integration the error introduced will be of a cumulative nature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has long been thought that tropical rainfall retrievals from satellites have large errors. Here we show, using a new daily 1 degree gridded rainfall data set based on about 1800 gauges from the India Meteorology Department (IMD), that modern satellite estimates are reasonably close to observed rainfall over the Indian monsoon region. Daily satellite rainfalls from the Global Precipitation Climatology Project (GPCP 1DD) and the Tropical Rainfall Measuring Mission (TRMM) Multisatellite Precipitation Analysis (TMPA) are available since 1998. The high summer monsoon (June-September) rain over the Western Ghats and Himalayan foothills is captured in TMPA data. Away from hilly regions, the seasonal mean and intraseasonal variability of rainfall (averaged over regions of a few hundred kilometers linear dimension) from both satellite products are about 15% of observations. Satellite data generally underestimate both the mean and variability of rain, but the phase of intraseasonal variations is accurate. On synoptic timescales, TMPA gives reasonable depiction of the pattern and intensity of torrential rain from individual monsoon low-pressure systems and depressions. A pronounced biennial oscillation of seasonal total central India rain is seen in all three data sets, with GPCP 1DD being closest to IMD observations. The new satellite data are a promising resource for the study of tropical rainfall variability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper presents an innovative approach to modelling the causal relationships of human errors in rail crack incidents (RCI) from a managerial perspective. A Bayesian belief network is developed to model RCI by considering the human errors of designers, manufactures, operators and maintainers (DMOM) and the causal relationships involved. A set of dependent variables whose combinations express the relevant functions performed by each DMOM participant is used to model the causal relationships. A total of 14 RCI on Hong Kong’s mass transit railway (MTR) from 2008 to 2011 are used to illustrate the application of the model. Bayesian inference is used to conduct an importance analysis to assess the impact of the participants’ errors. Sensitivity analysis is then employed to gauge the effect the increased probability of occurrence of human errors on RCI. Finally, strategies for human error identification and mitigation of RCI are proposed. The identification of ability of maintainer in the case study as the most important factor influencing the probability of RCI implies the priority need to strengthen the maintenance management of the MTR system and that improving the inspection ability of the maintainer is likely to be an effective strategy for RCI risk mitigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Effects of cochannel interference and synchronization error of the carrier phase on the probability of error in binary communications are considered. Several bounds on the probability of error are proposed. The bounds are easy to compute and do not require complete statistical characterization of the errors. They turn out to be simple linear combinations of error probabilities with no cochannel interferences and no phase errors. Several illustrative examples are given which show that the bounds can be tight.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The time–history of the performance of a system is treated as a stochastic corrective process, in which deterioration due to aging is counteracted at brief maintenance checks. Using a diffusion approximation for the deterioration, simple models are proposed for describing maintenance either by component replacement or by performance restoration. Equilibrium solutions of the models show that the performance has a probability distribution with exponential tails: the uncritical use of Gaussians can grossly underestimate the probability of poor performance. The proposed models are supported by recent observational evidence on aircraft track-keeping errors, which are shown to follow the modified exponential distribution derived here. The analysis also brings out the relation between the deterioration characteristics of the system and the intensity of the maintenance effort required to achieve a given performance reliability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Poor clinical handover has been associated with inaccurate clinical assessment and diagnosis, delays in diagnosis and test ordering, medication errors and decreased patient satisfaction in the acute care setting. Research on the handover process in the residential aged care sector is very limited. Purpose The aims of this study were to: (i) Develop an in-depth understanding of the handover process in aged care by mapping all the key activities and their information dynamics, (ii) Identify gaps in information exchange in the handover process and analyze implications for resident safety, (iii) Develop practical recommendations on how information communication technology (ICT) can improve the process and resident safety. Methods The study was undertaken at a large metropolitan facility in NSW with more than 300 residents and a staff including 55 registered nurses (RNs) and 146 assistants in nursing (AINs). A total of 3 focus groups, 12 interviews and 3 observation sessions were conducted over a period from July to October 2010. Process mapping was undertaken by translating the qualitative data via a five-category code book that was developed prior to the analysis. Results Three major sub-processes were identified and mapped. The three major stages are Handover process (HOP) I “Information gathering by RN”, HOP II “Preparation of preliminary handover sheet” and HOP III “Execution of handover meeting”. Inefficient processes were identified in relation to the handover including duplication of information, utilization of multiple communication modes and information sources, and lack of standardization. Conclusion By providing a robust process model of handover this study has made two critical contributions to research in aged care: (i) a means to identify important, possibly suboptimal practices; and (ii) valuable evidence to plan and improve ICT implementation in residential aged care. The mapping of this process enabled analysis of gaps in information flow and potential impacts on resident safety. In addition it offers the basis for further studies into a process that, despite its importance for securing resident safety and continuity of care, lacks research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A measure of stability of a given epitope is an important parameter in the exploration of the utility of a desired MAb. It defines the conditions necessary for using MAbs as an investigative tool in several research methodologies and therapeutic protocols. Despite these obvious interests the lack of simple and rapid assay systems for quantitating MAb-Ag interactions has largely hampered these studies. A single step MAb-Solid Phase Radioimmunoassay (SS-SPRIA), is described which eliminates errors that may arise with multistep sandwich assays. SS-SPRIA has been used to demonstrate the differential stability of the assembled epitopes on gonadotropins. Differential stability towards specific reagents can be exploited to identify aminoacid residues at the epitopic site. Inactivation of an epitopic region is indicative of the presence of the group modified, provided conformational relaxations are not induced due to modifications at distant sites. Here we provide evidence to validate these conclusions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present robust joint nonlinear transceiver designs for multiuser multiple-input multiple-output (MIMO) downlink in the presence of imperfections in the channel state information at the transmitter (CSIT). The base station (BS) is equipped with multiple transmit antennas, and each user terminal is equipped with one or more receive antennas. The BS employs Tomlinson-Harashima precoding (THP) for interuser interference precancellation at the transmitter. We consider robust transceiver designs that jointly optimize the transmit THP filters and receive filter for two models of CSIT errors. The first model is a stochastic error (SE) model, where the CSIT error is Gaussian-distributed. This model is applicable when the CSIT error is dominated by channel estimation error. In this case, the proposed robust transceiver design seeks to minimize a stochastic function of the sum mean square error (SMSE) under a constraint on the total BS transmit power. We propose an iterative algorithm to solve this problem. The other model we consider is a norm-bounded error (NBE) model, where the CSIT error can be specified by an uncertainty set. This model is applicable when the CSIT error is dominated by quantization errors. In this case, we consider a worst-case design. For this model, we consider robust (i) minimum SMSE, (ii) MSE-constrained, and (iii) MSE-balancing transceiver designs. We propose iterative algorithms to solve these problems, wherein each iteration involves a pair of semidefinite programs (SDPs). Further, we consider an extension of the proposed algorithm to the case with per-antenna power constraints. We evaluate the robustness of the proposed algorithms to imperfections in CSIT through simulation, and show that the proposed robust designs outperform nonrobust designs as well as robust linear transceiver designs reported in the recent literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we examine the major predictions made so far regarding the nature of climate change and its impacts on our region in the light of the known errors of the set of models and the observations over this century. The major predictions of the climate models about the impact of increased concentration of greenhouse gases ave at variance with the observations over the Indian region during the last century characterized by such increases and global warming. It is important to note that as far as the Indian region is concerned, the impact of year-to-year variation of the monsoon will continue to be dominant over longer period changes even in the presence of global warming. Recent studies have also brought out the uncertainties in the yields simulated by crop models. It is suggested that a deeper understanding of the links between climate and agricultural productivity is essential for generating reliable predictions of impact of climate change. Such an insight is also required for identifying cropping patterns and management practices which are tailored for sustained maximum yield in the face of the vagaries of the monsoon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although various strategies have been developed for scheduling parallel applications with independent tasks, very little work exists for scheduling tightly coupled parallel applications on cluster environments. In this paper, we compare four different strategies based on performance models of tightly coupled parallel applications for scheduling the applications on clusters. In addition to algorithms based on existing popular optimization techniques, we also propose a new algorithm called Box Elimination that searches the space of performance model parameters to determine the best schedule of machines. By means of real and simulation experiments, we evaluated the algorithms on single cluster and multi-cluster setups. We show that our Box Elimination algorithm generates up to 80% more efficient schedule than other algorithms. We also show that the execution times of the schedules produced by our algorithm are more robust against the performance modeling errors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Refractive errors, especially myopia, seem to increase worldwide. Concurrently, the number of surgical refractive corrections has increased rapidly, with several million procedures performed annually. However, excimer laser surgery was introduced after a limited number of studies done with animals and to date there still are only few long-term follow-up studies of the results. The present thesis aims to evaluate the safety and functional outcome of, as well as to quantify the cellular changes and remodelling in the human cornea after, photorefractive keratectomy (PRK) and laser assisted in situ keratomileusis (LASIK). These procedures are the two most common laser surgical refractive methods. In Study I, myopic ophthalmic residents at Helsinki University Eye Hospital underwent a refractive correction by PRK. Five patients were followed up for 6 months to assess their subjective experience in hospital work and their performance in car driving simulator and in other visuomotor functions. Corneal morphological changes were assessed by in vivo confocal microscopy (ivCM). Study II comprised 14 patients who had undergone a PRK operation in 1993-1994. Visual acuity was examined and ivCM examinations performed 5 years postoperatively. In Study III 15 patients received LASIK refractive correction for moderate to high myopia (-6 - -12 D). Their corneal recovery was followed by ivCM for 2 years. Diffuse lamellar keratitis (DLK) is a common but variable complication of LASIK. Yet, its aetiology remains unknown. In Study IV we examined six patients who had developed DLK as a consequence of formation of an intraoperative or post-LASIK epithelial defect, to assess the corneal and conjunctival inflammatory reaction. In the whole series, the mean refractive correction was -6.46 diopters. The best spectacle corrected visual acuity (BSCVA) improved in 30 % of patients, whereas in four patients BSCVA decreased slightly. The mean achieved refraction was 0.35 D undercorrected. After PRK, the stromal scar formation was highest at 2 to 3 months postoperatively and subsequently decreased. At 5 years increased reflectivity in the subepithelial stroma was observed in all patients. Interestingly, no Bowman s layer was detected in any patient. Subbasal nerve fiber bundle(snfb) regeneration could be observed already at 2 months in 2 patients after PRK. After 5 years, all corneas presented with snfb, the density of which, however, was still lower than in control corneas. LASIK induced a hypocellular area on both sides of the flap interface. A decrease of the most anterior keratocyte density was also observed. In the corneas that developed DLK, inflammatory cell-type objects were present in the flap interface in half of the patients. The other patients presented only with keratocyte activation and highly reflective extracellular matrix. These changes resolved completely with medication and time. Snfb regeneration was first detected at one month post-LASIK, but still after two years the density of snfb, however, was only 64 % of the preoperative values. The performance of ophthalmological examinations and microsurgery without spectacles was easier postoperatively, which was appreciated by the residents. Both PRK and LASIK showed moderate to good accuracy and high safety. In terms of visual perception and subjective evaluation, few patients stated any complaints in the whole series of studies. Instead, the majority of patients experienced a marked improvement in everyday life and work performance. PRK and LASIK have shown similar results, with good long term morphological healing. It seems evident that, even without the benefit of over-20-year follow-up results, these procedures are sufficiently safe and accurate for refractive corrections and corneal reshaping.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accurately quantifying total greenhouse gas emissions (e.g. methane) from natural systems such as lakes, reservoirs and wetlands requires the spatial-temporal measurement of both diffusive and ebullitive (bubbling) emissions. Traditional, manual, measurement techniques provide only limited localised assessment of methane flux, often introducing significant errors when extrapolated to the whole-of-system. In this paper, we directly address these current sampling limitations and present a novel multiple robotic boat system configured to measure the spatiotemporal release of methane to atmosphere across inland waterways. The system, consisting of multiple networked Autonomous Surface Vehicles (ASVs) and capable of persistent operation, enables scientists to remotely evaluate the performance of sampling and modelling algorithms for real-world process quantification over extended periods of time. This paper provides an overview of the multi-robot sampling system including the vehicle and gas sampling unit design. Experimental results are shown demonstrating the system’s ability to autonomously navigate and implement an exploratory sampling algorithm to measure methane emissions on two inland reservoirs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magnetotransport measurements in pulsed fields up to 15 T have been performed on mercury cadmium telluride (Hg1-xCdxTe, x similar to 0.2) bulk as well as liquid phase epitaxially grown samples to obtain the resistivity and conductivity tensors in the temperature range 220-300 K. Mobilities and densities of various carriers participating in conduction have been extracted using both conventional multicarrier fitting (MCF) and mobility spectrum analysis. The fits to experimental data, particularly at the highest magnetic fields, were substantially improved when MCF is applied to minimize errors simultaneously on both resistivity and conductivity tensors. The semiclassical Boltzmann transport equation has been solved without using adjustable parameters by incorporating the following scattering mechanisms to fit the mobility: ionized impurity, polar and nonpolar optical phonons, acoustic deformation potential, and alloy disorder. Compared to previous estimates based on the relaxation time approximation with outscattering only, polar optical scattering and ionized impurity scattering limited mobilities are shown to be larger due to the correct incorporation of the inscattering term taking into account the overlap integrals in the valence band.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Visual acuities at the time of referral and on the day before surgery were compared in 124 patients operated on for cataract in Vaasa Central Hospital, Finland. Preoperative visual acuity and the occurrence of ocular and general disease were compared in samples of consecutive cataract extractions performed in 1982, 1985, 1990, 1995 and 2000 in two hospitals in the Vaasa region in Finland. The repeatability and standard deviation of random measurement error in visual acuity and refractive error determination in a clinical environment in cataractous, pseudophakic and healthy eyes were estimated by re-examining visual acuity and refractive error of patients referred to cataract surgery or consultation by ophthalmic professionals. Altogether 99 eyes of 99 persons (41 cataractous, 36 pseudophakic and 22 healthy eyes) with a visual acuity range of Snellen 0.3 to 1.3 (0.52 to -0.11 logMAR) were examined. During an average waiting time of 13 months, visual acuity in the study eye decreased from 0.68 logMAR to 0.96 logMAR (from 0.2 to 0.1 in Snellen decimal values). The average decrease in vision was 0.27 logMAR per year. In the fastest quartile, visual acuity change per year was 0.75 logMAR, and in the second fastest 0.29 logMAR, the third and fourth quartiles were virtually unaffected. From 1982 to 2000, the incidence of cataract surgery increased from 1.0 to 7.2 operations per 1000 inhabitants per year in the Vaasa region. The average preoperative visual acuity in the operated eye increased by 0.85 logMAR (in decimal values from 0.03to 0.2) and in the better eye 0.27 logMAR (in decimal values from 0.23 to 0.43) over this period. The proportion of patients profoundly visually handicapped (VA in the better eye <0.1) before the operation fell from 15% to 4%, and that of patients less profoundly visually handicapped (VA in the better eye 0.1 to <0.3) from 47% to 15%. The repeatability visual acuity measurement estimated as a coefficient of repeatability for all 99 eyes was ±0.18 logMAR, and the standard deviation of measurement error was 0.06 logMAR. Eyes with the lowest visual acuity (0.3-0.45) had the largest variability, the coefficient of repeatability values being ±0.24 logMAR and eyes with a visual acuity of 0.7 or better had the smallest, ±0.12 logMAR. The repeatability of refractive error measurement was studied in the same patient material as the repeatability of visual acuity. Differences between measurements 1 and 2 were calculated as three-dimensional vector values and spherical equivalents and expressed by coefficients of repeatability. Coefficients of repeatability for all eyes for vertical, torsional and horisontal vectors were ±0.74D, ±0.34D and ±0.93D, respectively, and for spherical equivalent for all eyes ±0.74D. Eyes with lower visual acuity (0.3-0.45) had larger variability in vector and spherical equivalent values (±1.14), but the difference between visual acuity groups was not statistically significant. The difference in the mean defocus equivalent between measurements 1 and 2 was, however, significantly greater in the lower visual acuity group. If a change of ±0.5D (measured in defocus equivalents) is accepted as a basis for change of spectacles for eyes with good vision, the basis for eyes in the visual acuity range of 0.3 - 0.65 would be ±1D. Differences in repeated visual acuity measurements are partly explained by errors in refractive error measurements.