914 resultados para Binary panels
Resumo:
Nanocrystalline samples of Ba1-xCaxF2 prepared by high-energy milling show an unusually high F-ion conductivity, which exhibit a maximum in the magnitude and a minimum in the activation energy at x = 0.5. Here, we report an X-ray absorption spectroscopy (XAS) at the Ca and Sr K edges and the Ba L-3 edge and a molecular dynamics (MD) simulation study of the pure and mixed fluorides. The XAS measurements on the pure binary fluorides, CaF2, SrF2 and BaF2 show that high-energy ball-milling produces very little amorphous material, in contrast to the results for ball milled oxides. XAS measurements of Ba1-xCaxF2 reveal that for 0 < x < 1 there is considerable disorder in the local environments of the cations which is highest for x = 0.5. Hence the maximum in the conductivity corresponds to the composition with the maximum level of local disorder. The MD calculations also show a highly disordered structure consistent with the XAS results and similarly showing maximum disorder at x = 0.5.
Resumo:
The size of online image datasets is constantly increasing. Considering an image dataset with millions of images, image retrieval becomes a seemingly intractable problem for exhaustive similarity search algorithms. Hashing methods, which encodes high-dimensional descriptors into compact binary strings, have become very popular because of their high efficiency in search and storage capacity. In the first part, we propose a multimodal retrieval method based on latent feature models. The procedure consists of a nonparametric Bayesian framework for learning underlying semantically meaningful abstract features in a multimodal dataset, a probabilistic retrieval model that allows cross-modal queries and an extension model for relevance feedback. In the second part, we focus on supervised hashing with kernels. We describe a flexible hashing procedure that treats binary codes and pairwise semantic similarity as latent and observed variables, respectively, in a probabilistic model based on Gaussian processes for binary classification. We present a scalable inference algorithm with the sparse pseudo-input Gaussian process (SPGP) model and distributed computing. In the last part, we define an incremental hashing strategy for dynamic databases where new images are added to the databases frequently. The method is based on a two-stage classification framework using binary and multi-class SVMs. The proposed method also enforces balance in binary codes by an imbalance penalty to obtain higher quality binary codes. We learn hash functions by an efficient algorithm where the NP-hard problem of finding optimal binary codes is solved via cyclic coordinate descent and SVMs are trained in a parallelized incremental manner. For modifications like adding images from an unseen class, we propose an incremental procedure for effective and efficient updates to the previous hash functions. Experiments on three large-scale image datasets demonstrate that the incremental strategy is capable of efficiently updating hash functions to the same retrieval performance as hashing from scratch.
Resumo:
Background Many acute stroke trials have given neutral results. Sub-optimal statistical analyses may be failing to detect efficacy. Methods which take account of the ordinal nature of functional outcome data are more efficient. We compare sample size calculations for dichotomous and ordinal outcomes for use in stroke trials. Methods Data from stroke trials studying the effects of interventions known to positively or negatively alter functional outcome – Rankin Scale and Barthel Index – were assessed. Sample size was calculated using comparisons of proportions, means, medians (according to Payne), and ordinal data (according to Whitehead). The sample sizes gained from each method were compared using Friedman 2 way ANOVA. Results Fifty-five comparisons (54 173 patients) of active vs. control treatment were assessed. Estimated sample sizes differed significantly depending on the method of calculation (Po00001). The ordering of the methods showed that the ordinal method of Whitehead and comparison of means produced significantly lower sample sizes than the other methods. The ordinal data method on average reduced sample size by 28% (inter-quartile range 14–53%) compared with the comparison of proportions; however, a 22% increase in sample size was seen with the ordinal method for trials assessing thrombolysis. The comparison of medians method of Payne gave the largest sample sizes. Conclusions Choosing an ordinal rather than binary method of analysis allows most trials to be, on average, smaller by approximately 28% for a given statistical power. Smaller trial sample sizes may help by reducing time to completion, complexity, and financial expense. However, ordinal methods may not be optimal for interventions which both improve functional outcome
Resumo:
Background and Purpose—Vascular prevention trials mostly count “yes/no” (binary) outcome events, eg, stroke/no stroke. Analysis of ordered categorical vascular events (eg, fatal stroke/nonfatal stroke/no stroke) is clinically relevant and could be more powerful statistically. Although this is not a novel idea in the statistical community, ordinal outcomes have not been applied to stroke prevention trials in the past. Methods—Summary data on stroke, myocardial infarction, combined vascular events, and bleeding were obtained by treatment group from published vascular prevention trials. Data were analyzed using 10 statistical approaches which allow comparison of 2 ordinal or binary treatment groups. The results for each statistical test for each trial were then compared using Friedman 2-way analysis of variance with multiple comparison procedures. Results—Across 85 trials (335 305 subjects) the test results differed substantially so that approaches which used the ordinal nature of stroke events (fatal/nonfatal/no stroke) were more efficient than those which combined the data to form 2 groups (P0.0001). The most efficient tests were bootstrapping the difference in mean rank, Mann–Whitney U test, and ordinal logistic regression; 4- and 5-level data were more efficient still. Similar findings were obtained for myocardial infarction, combined vascular outcomes, and bleeding. The findings were consistent across different types, designs and sizes of trial, and for the different types of intervention. Conclusions—When analyzing vascular events from prevention trials, statistical tests which use ordered categorical data are more efficient and are more likely to yield reliable results than binary tests. This approach gives additional information on treatment effects by severity of event and will allow trials to be smaller. (Stroke. 2008;39:000-000.)
Resumo:
Isobaric vapor-liquid equilibria of binary mixtures of isopropyl acetate plus an alkanol (1-propanol, 2-propanol, 1-butanol, or 2-butanol) were measured at 101.32 kPa, using a dynamic recirculating still. An azeotropic behavior was observed only in the mixtures of isopropyl acetate + 2-propanol and isopropyl acetate + 1-propanol. The application of four thermodynamic consistency tests (the Herington test, the Van Ness test, the infinite dilution test, and the pure component test) showed the high quality of the experimental data. Finally, both NRTL and UNIQUAC activity coefficient models were successfully applied in the correlation of the measured data, with the average absolute deviations in vapor phase composition and temperature of 0.01 and 0.16 K, respectively.
Resumo:
Sequential panel selection methods (spsms — procedures that sequentially use conventional panel unit root tests to identify I(0)I(0) time series in panels) are increasingly used in the empirical literature. We check the reliability of spsms by using Monte Carlo simulations based on generating directly the individual asymptotic pp values to be combined into the panel unit root tests, in this way isolating the classification abilities of the procedures from the small sample properties of the underlying univariate unit root tests. The simulations consider both independent and cross-dependent individual test statistics. Results suggest that spsms may offer advantages over time series tests only under special conditions.
Resumo:
Doutoramento em Matemática.
Resumo:
Materials with new visual appearances have emerged over the last few years. In the automotive industry in particular there is a growing interest in materials with new effect finishes, such as metallic, pearlescent, sparkle, and graininess effects. Typically, for solid colours the mean of three measurements with repetitions is sufficient to obtain a representative measurement for colour characterisation. However, gonio-apparent panels have non-homogeneous colours, and there are no studies that recommend the minimum number of repetitions for colour, sparkle, and graininess characterisation of this type of panel. We assume that colour panels incorporating special-effect pigments in their colour recipes will require a higher minimum number of measurements than solid colour panels. Therefore, the purpose of this study is to verify this assumption by using a multiangle BYK-mac spectrophotometer, given that it is currently the only commercial device that can measure colour, sparkle, and graininess values simultaneously. In addition, a possible methodology is given for establishing the minimum number of measurements when characterising gonio-apparent materials using a specific instrument, able to be implemented in future instruments when determining multiple appearance attributes (colour, gloss, sparkle, etc.) for many coloration technologies. Thus, we studied the minimum number of measurements needed to characterise the colour, sparkle, and graininess of three types of sample with solid, metallic, and pearlescent coatings respectively. Twenty measurements were made at twenty random positions (different target areas) of 90 samples. The minimum number of measurements for all these variables was determined on the basis of the point at which the cumulative mean value became constant. Thus, applying new statistical tools, it is clearly shown that metallic and pearlescent panels require more colour measurements than solid panels, in particular when geometries are being measured in a specular direction. As regards texture (sparkle and graininess), more measurements are needed for graininess than for sparkle, and more for metallic panels than for pearlescent panels.
Resumo:
The 2007 Indigent Defense Act provides that each county must elect its representative(s) from the active licensed attorneys who reside within each county to serve on its Circuit Public Defender Selection Panel. The procedures included in this document have been adopted by the Commission on Indigent Defense for the Election of the Circuit Public Defender Selection Panels and the Nomination of Circuit Public Defenders.
Resumo:
In Portugal, Veterinary Pathology is developing rapidly, and in recent years we assist to the emergence of private laboratories and the restructuring of universities,polytechnics and public laboratories.The Portuguese Society of Animal Pathology,through its actions and its associates has been keeping the discussion among its peers in order to standardizethe criteria of description,classification and evaluation of cases which are the subject of our daily work.One of the last challenges is associated with the use of routine histochemical techniques and immunohistochemistry, in an effort to establish standardized panels for tumour diagnosis, which could eventually reduce each analysis cost.For this purpose a simple survey was built, in which all collaborators answered questions about the markers used for carcinoma, sarcoma and round cell tumour diagnosis, as well as general questions related with the subject. We obtained twenty-one answered to the questions, from public and private laboratories.In general, in most cases immunohistochemical and histochemical methods are used for diagnosis.The wide spectrum cytokeratins are universally used to confirm carcinoma, and vimentin for sarcoma. The CD3 marker is used by all laboratories to identify T lymphocytes. For the diagnosis of B-cell lymphoma, the marker used is not consensual. In each laboratory there are different markers for more specific situations and only two labs perform PCR techniques for diagnosis. These data will be presented to promote extended discussion,namely to reach a consensus when different markers are used.
Resumo:
Shockley diode equation is basic for single diode model equation, which is overly used for characterizing the photovoltaic cell output and behavior. In the standard equation, it includes series resistance (Rs) and shunt resistance (Rsh) with different types of parameters. Maximum simulation and modeling work done previously, related to single diode photovoltaic cell used this equation. However, there is another form of the standard equation which has not included Series Resistance (Rs) and Shunt Resistance (Rsh) yet, as the Shunt Resistance is much bigger than the load resistance and the load resistance is much bigger than the Series Resistance. For this phenomena, very small power loss occurs within a photovoltaic cell. This research focuses on the comparison of two forms of basic Shockley diode equation. This analysis describes a deep understanding of the photovoltaic cell, as well as gives understanding about Series Resistance (Rs) and Shunt Resistance (Rsh) behavior in the Photovoltaic cell. For making estimation of a real time photovoltaic system, faster calculation is needed. The equation without Series Resistance and Shunt Resistance is appropriate for the real time environment. Error function for both Series resistance (Rs) and Shunt resistances (Rsh) have been analyzed which shows that the total system is not affected by this two parameters' behavior.
Resumo:
This paper assesses and compares the performances of two daylight collection strategies, one passive and one active, for large-scale mirrored light pipes (MLP) illuminating deep plan buildings. Both strategies use laser cut panels (LCP) as the main component of the collection system. The passive system comprises LCPs in pyramid form, whereas the active system uses a tiled LCP on a simple rotation mechanism that rotates 360° in 24 hours. Performance is assessed using scale model testing under sunny sky conditions and mathematical modelling. Results show average illuminance levels for the pyramid LCP ranging from 50 to 250 lux and 150 to 200 lux for the rotating LCPs. Both systems improve the performance of a MLP. The pyramid LCP increases the performance of a MLP by 2.5 times and the rotating LCP by 5 times, when compared to an open pipe particularly for low sun elevation angles.