977 resultados para Band pass filtering


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that for a large class of exchange-correlation functionals the local exchange-correlation potential obtained within an optimized effective potential severely underestimates the band gap. On the other hand, the corresponding nonlocal potential obtained from a generalized Kohn-Sham scheme provides a much better description of the band gap, in good agreement with experiments. These results strongly indicate that a local exchange-correlation potential, however good the exchange-correlation approximation, cannot capture the delicate interplay between correlation effects and spatial localization in the KS band structure, unless the (cumbersome) contribution from the derivative discontinuity of the exchange-correlation energy functional is considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Theoretically the Kohn-Sham band gap differs from the exact quasiparticle energy gap by the derivative discontinuity of the exchange-correlation functional. In practice for semiconductors and insulators the band gap calculated within any local or semilocal density approximations underestimates severely the experimental energy gap. On the other hand, calculations with an "exact" exchange potential derived from many-body perturbation theory via the optimized effective potential suggest that improving the exchange-correlation potential approximation can yield a reasonable agreement between the Kohn-Sham band gap and the experimental gap. The results in this work show that this is not the case. In fact, we add to the exact exchange the correlation that corresponds to the dynamical (random phase approximation) screening in the GW approximation. This accurate exchange-correlation potential provides band structures similar to the local density approximation with the corresponding derivative discontinuity that contributes 30%-50% to the energy gap. Our self-consistent results confirm substantially the results for Si and other semiconductors obtained perturbatively [R. W. Godby , Phys. Rev. B 36, 6497 (1987)] and extend the conclusion to LiF and Ar, a wide-gap insulator and a noble-gas solid. (c) 2006 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Children born very preterm, even when intelligence is broadly normal, often experience selective difficulties in executive function and visual-spatial processing. Development of structural cortical connectivity is known to be altered in this group, and functional magnetic resonance imaging (fMRI) evidence indicates that very preterm children recruit different patterns of functional connectivity between cortical regions during cognition. Synchronization of neural oscillations across brain areas has been proposed as a mechanism for dynamically assigning functional coupling to support perceptual and cognitive processing, but little is known about what role oscillatory synchronization may play in the altered neurocognitive development of very preterm children. To investigate this, we recorded magnetoencephalographic (MEG) activity while 7-8 year old children born very preterm and age-matched full-term controls performed a visual short-term memory task. Very preterm children exhibited reduced long-range synchronization in the alpha-band during visual short-term memory retention, indicating that cortical alpha rhythms may play a critical role in altered patterns functional connectivity expressed by this population during cognitive and perceptual processing. Long-range alpha-band synchronization was also correlated with task performance and visual-perceptual ability within the very preterm group, indicating that altered alpha oscillatory mechanisms mediating transient functional integration between cortical regions may be relevant to selective problems in neurocognitive development in this vulnerable population at school age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, we focus on the analysis of competitive gene set methods for detecting the statistical significance of pathways from gene expression data. Our main result is to demonstrate that some of the most frequently used gene set methods, GSEA, GSEArot and GAGE, are severely influenced by the filtering of the data in a way that such an analysis is no longer reconcilable with the principles of statistical inference, rendering the obtained results in the worst case inexpressive. A possible consequence of this is that these methods can increase their power by the addition of unrelated data and noise. Our results are obtained within a bootstrapping framework that allows a rigorous assessment of the robustness of results and enables power estimates. Our results indicate that when using competitive gene set methods, it is imperative to apply a stringent gene filtering criterion. However, even when genes are filtered appropriately, for gene expression data from chips that do not provide a genome-scale coverage of the expression values of all mRNAs, this is not enough for GSEA, GSEArot and GAGE to ensure the statistical soundness of the applied procedure. For this reason, for biomedical and clinical studies, we strongly advice not to use GSEA, GSEArot and GAGE for such data sets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Band excitation piezoresponse force microscopy enables local investigation of the nonlinear piezoelectric behavior of ferroelectric thin films. However, the presence of additional nonlinearity associated with the dynamic resonant response of the tip-surface junction can complicate the study of a material's nonlinearity. Here, the relative importance of the two nonlinearity sources was examined as a function of the excitation function. It was found that in order to minimize the effects of nonlinear tip-surface interactions but achieve good signal to noise level, an optimal excitation function must be used. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3593138]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to describe the outcome of patients with filtering blebs who were fit with contact lenses. Methods: We retrospectively studied patients with filtering blebs secondary to glaucoma or cataract surgery who were fit with contact lenses. Eight eyes from seven patients were identified. Results: Five patients (six eyes) were fit with gas permeable contact lenses and two patients (two eyes) were fit with soft contact lenses. Successful fits were achieved in all patients. No complications were observed after a mean follow-up of 64.6±28.5 months. Conclusions: No significant complications were recorded in our series of patients with filtering blebs who were fit with contact lenses. We think that when indications for fitting contact lenses are justified, patients with filtering blebs are acceptable candidates for contact lens use. However, adequate selection of cases, careful contact lens fitting, patient education, and close follow-up are necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims. To evaluate the intraocular pressure (IOP) measurements in patients with band keratopathy or glued corneas obtained from affected and non-affected areas. Methods. 15 patients with band keratopathy or glued corneas were prospectively recruited. When both eyes were affected, only the right eye was analysed. Tono-Pen readings of IOP were obtained sequentially from the affected and non-affected corneal surface. Additionally, Goldmann applanation tonometry was attempted. Results. Determination of IOP with the Tono-Pen was possible in all cases, while Goldmann tonometry was not performed in three patients because of severe corneal irregularities. The average of the Tono-Pen readings obtained from the affected cornea (34.8 (SD 14.0) mmHg) was consistently and significantly higher (p <0.001) than mean IOP obtained by the Tono-Pen from the non-affected area (14.8 (4.3) mmHg). The average of Goldmann tonometry readings (14.4 (6.1) mmHg) did not differ significantly from the Tono-Pen values obtained from the non-affected corneal area (p = 0.47) but was significantly lower than the Tono-Pen measurements obtained from the affected area (p <0.001) Conclusion. In patients with band keratopathy or glued corneas determination of IOP by Tono-Pen tonometry varies from affected to non-affected area. The Tono-Pen overestimates the level of IOP when it is applied to areas with band keratopathy or with glue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Guarded filtration surgery is commonly used to control the intraocular pressure (IOP) in glaucomatous patients. Filtration surgery lowers the IOP by creating a fistula between the inner compartments of the eye and the subconjunctival space (i.e., filtering bleb). There are several options to improve the function of filtering blebs and to prevent their failure. However, improvement of IOP control after guarded filtration procedures is associated with a higher frequency of bleb-related complications. Early (e.g., bleb leak, excessive filtration, flat anterior chamber, filtration failure) and late (e.g., bleb leak, excessive filtration and hypotony, symptomatic blebs, bleb encapsulation, filtration failure, bleb infection) complications associated with filtering procedures should be managed adequately to prevent further problems. Techniques to improve the function of filtering blebs and to treat postoperative complications have progressed over the past decade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: To determine the frequency of encapsulated blebs after guarded filtration procedures with mitomycin-C. PATIENTS AND METHODS: The authors reviewed the charts of all patients who had undergone a guarded filtration procedure with mitomycin-C. There were 235 patients (283 cases) who had more than 1 month of follow-up. RESULTS: An encapsulated bleb developed in 7 eyes (2.47%) of 6 patients. Identification of bleb encapsulation occurred at a mean follow-up time of 29.7 ± 14.6 days after surgery. The mean intraocular pressure at that point was 24.2 ± 13.5 mm Hg in the affected eyes. Three eyes were treated medically, and needling was performed in 4 eyes. CONCLUSION: There is a low frequency of encapsulated bleb formation after guarded filtration procedures with adjunctive mitomycin- C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of a multi-band antenna consisting of a microstrip patch with two U-slots is designed and tested for use in aircraft cabin wireless access points. The objective of this paper is to evaluate this antenna that covers most of the current wireless bands from 1.7GHz to 5.85GHz.A specially designed wideband probe antenna is used for characterization
of field radiated from this antenna. This measurement setup gives room for future development like human presence in the cabin, the fading effects, and the path loss between transmitter and receiver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design of a two-stage differential cascode power amplifier (PA) for 81-86 GHz E-band applications is presented. The PA was realised in SiGe technology with fT/fmax 170/250 GHz. A broadband transformer with efficiency higher than 79.4% from 71 GHz to 96 GHz is used as a BALUN. The PA delivers a 4.5 dBm saturated output power and exhibits a 13.4 dB gain at 83.6 GHz. The input and output return losses agree well with the design specifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the design, implementation, and characterization of a new type of passive power splitting and combining structure for use in a differential four-way power-combining amplifier operating at E-band. In order to achieve lowest insertion loss, input and output coils inductances are resonated with shunt capacitances. Simple C-L-C and L-C networks are proposed in order to compensate inductive loading due to routing line that would otherwise introduce mismatch and increase loss. Across 78-86 GHz band, measured insertion loss is about 7 dB. Measured return losses are >10 dB from 73 GHz to 94 GHz at the input port and >9 dB from 60 GHz to 94 GHz at the output port. When integrated with driver and power amplifier cells, the simulated complete circuit exhibits 18.2 dB gain and 20.3 dBm saturated output power.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A V-band wide tuning-range VCO and high frequency divide-by-8 frequency divider using Infineon 0.35 µm SiGe HBT process are presented in this paper. An LC impedance peaking technique is introduced in the Miller divider to increase the sensitivity and operation frequency range of the frequency divider. Two static frequency dividers implemented using current mode logic are used to realize dividing by 4 in the circuit. The wide tuning range VCO operates from 51.9 to 64.1 GHz i.e. 20.3% frequency tuning range. The measured phase noise at the frequency divider output stage is around -98.5 dBc at 1 MHz. The circuit consumes 200mW and operates from a 3.5Vdc supply, and occupies 0.6×0.8 mm2 die area.