994 resultados para Application Availability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To develop and evaluate a practical method for the quantification of signal-to-noise ratio (SNR) on coronary MR angiograms (MRA) acquired with parallel imaging.Materials and Methods: To quantify the spatially varying noise due to parallel imaging reconstruction, a new method has been implemented incorporating image data acquisition followed by a fast noise scan during which radio-frequency pulses, cardiac triggering and navigator gating are disabled. The performance of this method was evaluated in a phantom study where SNR measurements were compared with those of a reference standard (multiple repetitions). Subsequently, SNR of myocardium and posterior skeletal muscle was determined on in vivo human coronary MRA.Results: In a phantom, the SNR measured using the proposed method deviated less than 10.1% from the reference method for small geometry factors (<= 2). In vivo, the noise scan for a 10 min coronary MRA acquisition was acquired in 30 s. Higher signal and lower SNR, due to spatially varying noise, were found in myocardium compared with posterior skeletal muscle.Conclusion: SNR quantification based on a fast noise scan is a validated and easy-to-use method when applied to three-dimensional coronary MRA obtained with parallel imaging as long as the geometry factor remains low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: There is little information regarding the impact of diet on disease incidence and mortality in Switzerland. Objectives: We aimed at assessing the associations between food availability and disease using ecological correlations. Methods: Time-trend ecologic study for period 1970 to 2009. Food availability was measured through the FAO food balance sheets. Standardized mortality rates (SMRs) were obtained from the Swiss Federal Office of Statistics. Cancer incidence data was obtained from the WHO Health for all database and the Vaud cancer registry. Association between food availability and mortality/incidence was assessed at lags 0, 5, 10 and 15 years by Spearman correlation. Results: Alcoholic beverages and fruit availability were positively associated with SMRs from all types of cardiovascular disease, while fish availability was negatively associated. Animal products, meat and animal fats were positively associated with SMR from ischemic heart disease only. For cancers, opposite results were found whether the association used SMRs or incidence rates. For all cancers, alcoholic beverages and fruits were positively associated with SMRs but negatively associated with incidence rates. Similar findings were obtained for all other foods, with the exception of vegetables, which were weakly and negatively associated with SMRs and incidence rates. Finally, a 15 years lag time reversed the association for animal and vegetal products, weakened the association for alcohol and fruits and strengthened the association for fish. Conclusion: Ecologic associations between food availability and disease vary considerably whether mortality or incidence rates are used. Great care should be taken when interpreting the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé Lors d'une recherche d'information, l'apprenant est très souvent confronté à des problèmes de guidage et de personnalisation. Ceux-ci sont d'autant plus importants que la recherche se fait dans un environnement ouvert tel que le Web. En effet, dans ce cas, il n'y a actuellement pas de contrôle de pertinence sur les ressources proposées pas plus que sur l'adéquation réelle aux besoins spécifiques de l'apprenant. A travers l'étude de l'état de l'art, nous avons constaté l'absence d'un modèle de référence qui traite des problématiques liées (i) d'une part aux ressources d'apprentissage notamment à l'hétérogénéité de la structure et de la description et à la protection en terme de droits d'auteur et (ii) d'autre part à l'apprenant en tant qu'utilisateur notamment l'acquisition des éléments le caractérisant et la stratégie d'adaptation à lui offrir. Notre objectif est de proposer un système adaptatif à base de ressources d'apprentissage issues d'un environnement à ouverture contrôlée. Celui-ci permet de générer automatiquement sans l'intervention d'un expert pédagogue un parcours d'apprentissage personnalisé à partir de ressources rendues disponibles par le biais de sources de confiance. L'originalité de notre travail réside dans la proposition d'un modèle de référence dit de Lausanne qui est basé sur ce que nous considérons comme étant les meilleures pratiques des communautés : (i) du Web en terme de moyens d'ouverture, (ii) de l'hypermédia adaptatif en terme de stratégie d'adaptation et (iii) de l'apprentissage à distance en terme de manipulation des ressources d'apprentissage. Dans notre modèle, la génération des parcours personnalisés se fait sur la base (i) de ressources d'apprentissage indexées et dont le degré de granularité en favorise le partage et la réutilisation. Les sources de confiance utilisées en garantissent l'utilité et la qualité. (ii) de caractéristiques de l'utilisateur, compatibles avec les standards existants, permettant le passage de l'apprenant d'un environnement à un autre. (iii) d'une adaptation à la fois individuelle et sociale. Pour cela, le modèle de Lausanne propose : (i) d'utiliser ISO/MLR (Metadata for Learning Resources) comme formalisme de description. (ii) de décrire le modèle d'utilisateur avec XUN1 (eXtended User Model), notre proposition d'un modèle compatible avec les standards IEEE/PAPI et IMS/LIP. (iii) d'adapter l'algorithme des fourmis au contexte de l'apprentissage à distance afin de générer des parcours personnalisés. La dimension individuelle est aussi prise en compte par la mise en correspondance de MLR et de XUM. Pour valider notre modèle, nous avons développé une application et testé plusieurs scenarii mettant en action des utilisateurs différents à des moments différents. Nous avons ensuite procédé à des comparaisons entre ce que retourne le système et ce que suggère l'expert. Les résultats s'étant avérés satisfaisants dans la mesure où à chaque fois le système retourne un parcours semblable à celui qu'aurait proposé l'expert, nous sommes confortées dans notre approche.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS Colon capsule endoscopy (CCE) was developed for the evaluation of colorectal pathology. In this study, our aim was to assess if a dual-camera analysis using CCE allows better evaluation of the whole gastrointestinal (GI) tract compared to a single-camera analysis. PATIENTS AND METHODS We included 21 patients (12 males, mean age 56.20 years) submitted for a CCE examination. After standard colon preparation, the colon capsule endoscope (PillCam Colon™) was swallowed after reinitiation from its "sleep" mode. Four physicians performed the analysis: two reviewed both video streams at the same time (dual-camera analysis); one analyzed images from one side of the device ("camera 1"); and the other reviewed the opposite side ("camera 2"). We compared numbers of findings from different parts of the entire GI tract and level of agreement among reviewers. RESULTS A complete evaluation of the GI tract was possible in all patients. Dual-camera analysis provided 16% and 5% more findings compared to camera 1 and camera 2 analysis, respectively. Overall agreement was 62.7% (kappa = 0.44, 95% CI: 0.373-0.510). Esophageal (kappa = 0.611) and colorectal (kappa = 0.595) findings had a good level of agreement, while small bowel (kappa = 0.405) showed moderate agreement. CONCLUSION The use of dual-camera analysis with CCE for the evaluation of the GI tract is feasible and detects more abnormalities when compared with single-camera analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of Discriminant function analysis (DFA) is not a new idea in the studyof tephrochrology. In this paper, DFA is applied to compositional datasets of twodifferent types of tephras from Mountain Ruapehu in New Zealand and MountainRainier in USA. The canonical variables from the analysis are further investigated witha statistical methodology of change-point problems in order to gain a betterunderstanding of the change in compositional pattern over time. Finally, a special caseof segmented regression has been proposed to model both the time of change and thechange in pattern. This model can be used to estimate the age for the unknown tephrasusing Bayesian statistical calibration

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: : We describe a retinal endovascular fibrinolysis technique to directly reperfuse experimentally occluded retinal veins using a simple micropipette. METHODS: : Retinal vein occlusion was photochemically induced in 12 eyes of 12 minipigs: after intravenous injection of 10% fluorescein (1-mL bolus), the targeted retinal vein segment was exposed to thrombin (50 units) and to Argon laser (100-200 mW) through a pars plana approach. A beveled micropipette with a 30-μm-diameter sharp edge was used for micropuncture of the occluded vein and endovascular microinjection of tissue plasminogen activator (50 μg/mL) in 11 eyes. In one control eye, balanced salt solution was injected. The lesion site was examined histologically. RESULTS: : Retinal vein occlusion was achieved in all cases. Endovascular microinjection of tissue plasminogen activator or balanced salt solution led to reperfusion of the occluded retinal vein in all cases. Indicative of successful reperfusion were the following: continuous endovascular flow, unaffected collateral circulation, no optic disk ischemia, and no venous wall bleeding. However, balanced salt solution injection was accompanied by thrombus formation at the punctured site, whereas no thrombus was observed with tissue plasminogen activator injection. CONCLUSION: : Retinal endovascular fibrinolysis constitutes an efficient method of micropuncture and reperfusion of an experimentally occluded retinal vein. Thrombus formation at the punctured site can be prevented by injection of tissue plasminogen activator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Skin patch test is the gold standard method in diagnosing contact allergy. Although used for more than 100 years, the patch test procedure is performed with variability around the world. A number of factors can influence the test results, namely the quality of reagents used, the timing of the application, the patch test series (allergens/haptens) that have been used for testing, the appropriate interpretation of the skin reactions or the evaluation of the patient's benefit. METHODS We performed an Internet -based survey with 38 questions covering the educational background of respondents, patch test methods and interpretation. The questionnaire was distributed among all representatives of national member societies of the World Allergy Organization (WAO), and the WAO Junior Members Group. RESULTS One hundred sixty-nine completed surveys were received from 47 countries. The majority of participants had more than 5 years of clinical practice (61 %) and routinely carried out patch tests (70 %). Both allergists and dermatologists were responsible for carrying out the patch tests. We could observe the use of many different guidelines regardless the geographical distribution. The use of home-made preparations was indicated by 47 % of participants and 73 % of the respondents performed 2 or 3 readings. Most of the responders indicated having patients with adverse reactions, including erythroderma (12 %); however, only 30 % of members completed a consent form before conducting the patch test. DISCUSSION The heterogeneity of patch test practices may be influenced by the level of awareness of clinical guidelines, different training backgrounds, accessibility to various types of devices, the patch test series (allergens/haptens) used for testing, type of clinical practice (public or private practice, clinical or research-based institution), infrastructure availability, financial/commercial implications and regulations among others. CONCLUSION There is a lack of a worldwide homogeneity of patch test procedures, and this raises concerns about the need for standardization and harmonization of this important diagnostic procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 2009-2010 Data Fusion Contest organized by the Data Fusion Technical Committee of the IEEE Geoscience and Remote Sensing Society was focused on the detection of flooded areas using multi-temporal and multi-modal images. Both high spatial resolution optical and synthetic aperture radar data were provided. The goal was not only to identify the best algorithms (in terms of accuracy), but also to investigate the further improvement derived from decision fusion. This paper presents the four awarded algorithms and the conclusions of the contest, investigating both supervised and unsupervised methods and the use of multi-modal data for flood detection. Interestingly, a simple unsupervised change detection method provided similar accuracy as supervised approaches, and a digital elevation model-based predictive method yielded a comparable projected change detection map without using post-event data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Measuring syringe availability and coverage is essential in the assessment of HIV/AIDS risk reduction policies. Estimates of syringe availability and coverage were produced for the years 1996 and 2006, based on all relevant available national-level aggregated data from published sources. METHODS: We defined availability as the total monthly number of syringes provided by harm reduction system divided by the estimated number of injecting drug users (IDU), and defined coverage as the proportion of injections performed with a new syringe, at national level (total supply over total demand). Estimates of supply of syringes were derived from the national monitoring system, including needle and syringe programmes (NSP), pharmacies, and medically prescribed heroin programmes. Estimates of syringe demand were based on the number of injections performed by IDU derived from surveys of low threshold facilities for drug users (LTF) with NSP combined with the number of IDU. This number was estimated by two methods combining estimates of heroin users (multiple estimation method) and (a) the number of IDU in methadone treatment (MT) (non-injectors) or (b) the proportion of injectors amongst LTF attendees. Central estimates and ranges were obtained for availability and coverage. RESULTS: The estimated number of IDU decreased markedly according to both methods. The MT-based method (from 14,818 to 4809) showed a much greater decrease and smaller size of the IDU population compared to the LTF-based method (from 24,510 to 12,320). Availability and coverage estimates are higher with the MT-based method. For 1996, central estimates of syringe availability were 30.5 and 18.4 per IDU per month; for 2006, they were 76.5 and 29.9. There were 4 central estimates of coverage. For 1996 they ranged from 24.3% to 43.3%, and for 2006, from 50.5% to 134.3%. CONCLUSION: Although 2006 estimates overlap 1996 estimates, the results suggest a shift to improved syringe availability and coverage over time.