970 resultados para weld improvement method
Resumo:
Q-sort is a research method which allows defining profiles of attitudes toward a set of statements, ordered in relation to each other. Pertaining to the Q Methodology, the qualitative analysis of the Q-sorts is based on quantitative techniques. This method is of particular interest for research in health professions, a field in which attitudes of patients and professionals are very important. The method is presented in this article, along with an example of application in nursing in old age psychiatry.
Resumo:
In contemporary society, religious signification and secular systems mix and influence each other. Holistic conceptions of a world in which man is integrated harmoniously with nature meet representations of a world run by an immanent God. On the market of the various systems, the individual goes from one system to another, following his immediate needs and expectations without necessarily leaving any marks in a meaningful long term system. This article presents the first results of an ongoing research in Switzerland on contemporary religion focusing on (new) paths of socialization of modern that individuals and the various (non-) belief systems that they simultaneously develop
Resumo:
In recent years there has been extensive debate in the energy economics and policy literature on the likely impacts of improvements in energy efficiency. This debate has focussed on the notion of rebound effects. Rebound effects occur when improvements in energy efficiency actually stimulate the direct and indirect demand for energy in production and/or consumption. This phenomenon occurs through the impact of the increased efficiency on the effective, or implicit, price of energy. If demand is stimulated in this way, the anticipated reduction in energy use, and the consequent environmental benefits, will be partially or possibly even more than wholly (in the case of ‘backfire’ effects) offset. A recent report published by the UK House of Lords identifies rebound effects as a plausible explanation as to why recent improvements in energy efficiency in the UK have not translated to reductions in energy demand at the macroeconomic level, but calls for empirical investigation of the factors that govern the extent of such effects. Undoubtedly the single most important conclusion of recent analysis in the UK, led by the UK Energy Research Centre (UKERC) is that the extent of rebound and backfire effects is always and everywhere an empirical issue. It is simply not possible to determine the degree of rebound and backfire from theoretical considerations alone, notwithstanding the claims of some contributors to the debate. In particular, theoretical analysis cannot rule out backfire. Nor, strictly, can theoretical considerations alone rule out the other limiting case, of zero rebound, that a narrow engineering approach would imply. In this paper we use a computable general equilibrium (CGE) framework to investigate the conditions under which rebound effects may occur in the Scottish regional and UK national economies. Previous work has suggested that rebound effects will occur even where key elasticities of substitution in production are set close to zero. Here, we carry out a systematic sensitivity analysis, where we gradually introduce relative price sensitivity into the system, focusing in particular on elasticities of substitution in production and trade parameters, in order to determine conditions under which rebound effects become a likely outcome. We find that, while there is positive pressure for rebound effects even where (direct and indirect) demand for energy is very price inelastic, this may be partially or wholly offset by negative income and disinvestment effects, which also occur in response to falling energy prices.
Resumo:
This paper uses a computable general equilibrium (CGE) framework to investigate the conditions under which rebound effects may occur in response to increases in energy efficiency in the UK national economy. Previous work for the UK has suggested that rebound effects will occur even where key elasticities of substitution in production are set close to zero. The research reported in this paper involves carrying out a systematic sensitivity analysis, where relative price sensitivity is gradually introduced into the system, focusing specifically on elasticities of substitution in production and trade parameters, in order to determine conditions under which rebound effects become a likely outcome. The main result is that, while there is positive pressure for rebound effects even where (direct and indirect) demands for energy are very price inelastic, this may be partially or wholly offset by negative income, competitiveness and disinvestment effects, which also occur in response to falling energy prices. The occurrence of disinvestment effects is of particular interest. These occur where falling energy prices reduce profitability in domestic energy supply sectors, leading to a contraction in capital stock in these sectors, which may in turn lead to rebound effects that are smaller in the long run than in the short run, a result that runs contrary to the predictions of previous theoretical work in this area.
Resumo:
Proyecto de investigación realizado a partir de una estancia en el Centro Internacional de Métodos Computacionales en Ingeniería (CIMEC), Argentina, entre febrero y abril del 2007. La simulación numérica de problemas de mezclas mediante el Particle Finite Element Method (PFEM) es el marco de estudio de una futura tesis doctoral. Éste es un método desarrollado conjuntamente por el CIMEC y el Centre Internacional de Mètodos Numèrics en l'Enginyeria (CIMNE-UPC), basado en la resolución de las ecuaciones de Navier-Stokes en formulación Lagrangiana. El mallador ha sido implementado y desarrollado por Dr. Nestor Calvo, investigador del CIMEC. El desarrollo del módulo de cálculo corresponde al trabajo de tesis de la beneficiaria. La correcta interacción entre ambas partes es fundamental para obtener resultados válidos. En esta memoria se explican los principales aspectos del mallador que fueron modificados (criterios de refinamiento geométrico) y los cambios introducidos en el módulo de cálculo (librería PETSc, algoritmo predictor-corrector) durante la estancia en el CIMEC. Por último, se muestran los resultados obtenidos en un problema de dos fluidos inmiscibles con transferencia de calor.
Resumo:
BACKGROUND: Nowadays, cognitive remediation is widely accepted as an effective treatment for patients with schizophrenia. In French-speaking countries, techniques used in cognitive remediation for patients with schizophrenia have been applied from those used for patients with cerebral injury. As cognitive impairment is a core feature of schizophrenia, the Département de psychiatrie du CHUV in Lausanne (DP-CHUV) intended to develop a cognitive remediation program for patients with a schizophrenia spectrum disease (Recos-Vianin, 2007). Numerous studies show that the specific cognitive deficits greatly differ from one patient to another. Consequently, Recos aims at providing individualized cognitive remediation therapy. In this feasibility trial, we measured the benefits of this individualized therapy for patients with schizophrenia. Before treatment, the patients were evaluated with a large battery of cognitive tests in order to determine which of the five specific training modules - Verbal memory, visuospatial memory and attention, working memory, selective attention, reasoning - could provide the best benefit depending on their deficit. OBJECTIVES: The study was designed to evaluate the benefits of the Recos program by comparing cognitive functioning before and after treatment. METHOD: Twenty-eight patients with schizophrenia spectrum disorders (schizophrenia [n=18], schizoaffective disorder [n=5], schizotypal disorder [n=4], schizophreniform disorder [n=1], DSM-IV-TR) participated in between one and three of the cognitive modules. The choice of the training module was based on the results of the cognitive tests obtained during the first evaluation. The patients participated in 20 training sessions per module (one session per week). At the end of the training period, the cognitive functioning of each patient was reevaluated by using the same neuropsychological battery. RESULTS: The results showed a greater improvement in the cognitive functions, which were specifically trained, compared to the cognitive functions, which were not trained. However, an improvement was also observed in both types of cognitive functions, suggesting an indirect cognitive gain. CONCLUSION: In our view, the great heterogeneity of the observed cognitive deficits in schizophrenia necessitates a detailed neuropsychological investigation as well as an individualized cognitive remediation therapy. These preliminary results need to be confirmed with a more extended sample of patients.
Resumo:
A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.
Resumo:
Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.
Resumo:
BACKGROUND: A single infusion of intravenous zoledronic acid decreases bone turnover and improves bone density at 12 months in postmenopausal women with osteoporosis. We assessed the effects of annual infusions of zoledronic acid on fracture risk during a 3-year period. METHODS: In this double-blind, placebo-controlled trial, 3889 patients (mean age, 73 years) were randomly assigned to receive a single 15-minute infusion of zoledronic acid (5 mg) and 3876 were assigned to receive placebo at baseline, at 12 months, and at 24 months; the patients were followed until 36 months. Primary end points were new vertebral fracture (in patients not taking concomitant osteoporosis medications) and hip fracture (in all patients). Secondary end points included bone mineral density, bone turnover markers, and safety outcomes. RESULTS: Treatment with zoledronic acid reduced the risk of morphometric vertebral fracture by 70% during a 3-year period, as compared with placebo (3.3% in the zoledronic-acid group vs. 10.9% in the placebo group; relative risk, 0.30; 95% confidence interval [CI], 0.24 to 0.38) and reduced the risk of hip fracture by 41% (1.4% in the zoledronic-acid group vs. 2.5% in the placebo group; hazard ratio, 0.59; 95% CI, 0.42 to 0.83). Nonvertebral fractures, clinical fractures, and clinical vertebral fractures were reduced by 25%, 33%, and 77%, respectively (P<0.001 for all comparisons). Zoledronic acid was also associated with a significant improvement in bone mineral density and bone metabolism markers. Adverse events, including change in renal function, were similar in the two study groups. However, serious atrial fibrillation occurred more frequently in the zoledronic acid group (in 50 vs. 20 patients, P<0.001). CONCLUSIONS: A once-yearly infusion of zoledronic acid during a 3-year period significantly reduced the risk of vertebral, hip, and other fractures. (ClinicalTrials.gov number, NCT00049829.)
Resumo:
An ELISA Inhibition Method (EIM) was proposed for the serologic diagnosis of dengue, comparing its results with the Hemagglutination Inhibition (HI) and the IgM capture-ELISA (MAC-ELISA). Advantages and disadvantages of both methods are discussed according to sensitivity, specificity, performance and usefulness. As a conclusion we recommend the complementary inclusion of the EIM and MAC-ELISA substituting the HI for laboratories engaged in the diagnosis and surveillance of dengue.
Resumo:
A rapid and simple technique for the purification of Toxoplasma gondii tachyzoites was developed. Highly purified parasites were obtained from the peritoneal exudates of infected mice by means of two consecutive discontinous sucrose gradients run at low speed (10,000xg, 30 min). Parasites obtained by this method conserved its biological activity. Hybridizations tudies with DNA from healthy mice and from purified tachyzoites preparations demonstrated that Toxoplasma gondii tachyzoites DNA could be obtained with better than 90 per cents purity. Preliminary studies with DNA endonucleases showed the presence in the tachyzoites genome of highly repetitives sequences.
Resumo:
PURPOSE: To assess the safety and efficacy of treatment of macular edema secondary to central retinal vein occlusion (CRVO) with intravitreal bevacizumab. PATIENTS AND METHOD: The ongoing prospective study included 8 consecutive patients (8 eyes) with macular edema secondary to CRVO (6 non ischemic and 2 ischemic), treated with intravitreal injection of 1.25 mg (0.05 mL) of bevacizumab. Main outcome was best corrected visual acuity (BCVA) and central foveal thickness (CFT) measured by optical coherence tomography monthly during one year. Retreatment criteria include decrease of BCVA, persistence of macular edema on angiograms and increase of CFT. RESULTS: Mean age of the eight patients was 68 years (range: 50-82 years). Mean duration of symptoms before injection was 98 days (range: 3-289). Mean follow-up was 3.25 months. At baseline, mean BCVA was 0.84 logMar and mean baseline CFT was 771 microm. Mean BCVA was 0.36 and mean CFT thickness was 275 microm (n = 8) at month 1, 0.41 and 411 microm at month 2 (n = 7), 0.3 and 344 microm at month 3 (n = 6), 0.3 and 397 microm at month 4 (n = 5), respectively. In 75 % of patients, a single injection was not sufficient, and retreatment needed. No serious adverse events were observed. CONCLUSIONS: Treatment of macular edema secondary to CRVO with intravitreal bevacizumab injection of 1.25 mg was well tolerated and associated with marked macular thickness reduction and BCVA improvement in all patients. A trend towards reduction of foveal thickness and improvement of visual acuity was observed in both acute and chronic CRVO.
Resumo:
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.