931 resultados para voltage follower
Resumo:
The electrical and optical characteristics of a cylindrical alumina insulator (94% Al203) have been measured under ultra-high vacuum (P < 10-8 mBar) conditions. A high-resolution CCD camera was used to make real-time optical recordings of DC prebreakdown luminescence from the ceramic, under conditions where DC current magnitudes were limited to less than 50μA. Two concentric metallized rings formed a pair of co-axial electrodes, on the end-face of the alumina tube; a third 'transparent' electrode was employed to study the effect of an orthogonal electric field upon the radial conduction processes within the metallized alumina specimen. The wavelength-spectra of the emitted light was quantified using a high-speed scanning monochromator and photo-multiplier tube detector. Concurrent electrical measurements were made alongside the recording of optical-emission images. An observed time-dependence of the photon-emission is correlated with a time-variation observed in the DC current-voltage characteristics of the alumina. Optical images were also recorded of pulsed-field surface-flashover events on the alumina ceramic. An intensified high-speed video technique provided 1ms frames of surface-flashover events, whilst 100ns frames were achieved using an ultra high-speed fast-framing camera. By coupling this fast-frame camera to a digital storage oscilloscope, it was possible to establish a temporal correlation between the application of a voltage-pulse to the ceramic and the evolution of photonic emissions from the subsequent surface-flashover event. The electro-optical DC prebreakdown characteristics of the alumina are discussed in terms of solid-state photon-emission processes, that are believed to arise from radiative electron-recombination at vacancy-defects and substitutional impurity centres within the surface-layers of the ceramic. The physical nature of vacancy-defects within an alumina dielectric is extensively explored, with a particular focus placed upon the trapped electron energy-levels that may be present at these defect centres. Finally, consideration is given to the practical application of alumina in the trigger-ceramic of a sealed triggered vacuum gap (TVG) switch. For this purpose, a physical model describing the initiation of electrical breakdown within the TVG regime is proposed, and is based upon the explosive destabilisation of trapped charge within the alumina ceramic, triggering the onset of surface-flashover along the insulator. In the main-gap prebreakdown phase, it is suggested that the electrical-breakdown of the TVG is initiated by the low-field 'stripping' of prebreakdown electrons from vacancy-defects in the ceramic under the influence of an orthogonal main-gap electric field.
Resumo:
The following research project investigated the mediating effects of individual trust in the relationships between eight leadership dimensions and follower motivation and efficacy. The research comprised of a total of three studies of which two are individual level analyses investigating the above relationship for individual followers, while the final study established the relationship between the eight dimensions and collective efficacy and group cohesion. A new measure of trust — collective vertical trust — was developed and tested and formed the mediator for the final study. The findings showed that leadership is indeed mediated through trust on both individual and collective level in the majority of relationships. In addition it was shown that individual and collective vertical trust are significantly related. Finally, the final study showed an absence of a significant relationship between trust on both the individual and collective level and organizational performance. The findings contributed to existing research in various ways: 1) the mediating effect of individual trust was established for eight separate leadership dimensions; 2) the studies established that while the indirect effects of leadership on follower motivation are similar amongst all age groups and levels of work experience, more work experienced individuals draw their beliefs in their abilities (i.e., self-efficacy) from alternative sources than leadership or trust in the leader; 3) a new measure of collective trust —collective vertical trust was established; 4) the mediating effect of collective trust was shown to be crucial in leadership effects on collective efficacy and group cohesion; and finally 5) a leadership measure initially designed for executive leaders was refined and tested for non-executive leaders.
Resumo:
More-electric vehicle technology is becoming prevalent in a number of transportation systems because of its ability to improve efficiency and reduce costs. This paper examines the specific case of an Uninhabited Autonomous Vehicle (UAV), and the system topology and control elements required to achieve adequate dc distribution voltage bus regulation. Voltage control methods are investigated and a droop control scheme is implemented on the system. Simulation results are also presented.
Resumo:
Infection is a major clinical problem associated with the use of intravenous catheters.The efficacy of a direct electric current (10µA, 9V) via electrode-conducting carbon impregnated catheters to prevent colonisation of catheters by micro-organisms was investigated. The range of organisms susceptible to 10µA was determined by a zone of inhibition test. The catheters acting as the anode and the cathode were inserted into a nutrient agar plate inoculated with a lawn of bacteria. There was no zone of inhibition observed around the anode. Organisms susceptible to 10µA at the cathode were Staphylococcus aureus (2 strains), Staphylococcus epidermidis (5 strains), Escherichia coli and Klebsiella pneumoniae (2 strains each), and one strain of the following micro-organisms: Staphylococcus hominis, Proteus mirabilis, Pseudomonas aeruginosa and Candida albicans. The zones ranged from 6 to 16 mm in diameter according to the organisms under test. The zone size was proportional to the amperage (10 - 100 µA) and the number of organisms on the plate. Ten µA did not prevent adhesion of staphylococci to the cathode nor did it affect their growth in nutrient broth. However, it was bactericidal to adherent bacteria on the cathodal catheter and significantly reduced the number of bacteria on the catheter after 4 to 24 h application of electricity. The antimicrobial activity of low amperage electric current under anaerobic conditions and in the absence of chloride ions against bacteria attached to the surface of a current carrying electrode was also investigated.The mechanisms of the bactericidal activity associated with the cathode were investigated with S. epidermidis and S. aureus. The inhibition zone was greatly reduced in the presence of catalase. There was no zone around the cathode when the test was carried out under anaerobic conditions. Hydrogen peroxide was produced at the cathode surface under aerobic conditions, but not in the absence of oxygen. A salt-bridge apparatus was used to demonstrate further that hydrogen peroxide was produced at the cathode, and chlorine at the anode. The antimicrobial activity of low amperage electric current under anaerobic conditions and in the absence of chloride ions against bacteria attached to the surface of a current carrying electrode was also investigated. Antibacterial activity was reduced under anaerobic conditions, which is compatible with the role of hydrogen peroxide as a primary bactericidal agent of electricity associated with the cathode. A reduction in chloride ions did not significantly reduce the antibacterial activity suggesting chlorine plays only a minor role in the bactericidal activity against organisms attached to anodal electrode surfaces. The bactericidal activity of electric current associated with the cathode and H202 was greatly reduced in the presence of 50 μM to 0.5 mM magnesium ions in the test menstrum. Ten μA applied via the catheters did not prevent the initial biofilm growth by the adherent bacteria but reduced the number of bacteria in the biofilm by 2 log order aiter 24 h. The results suggested that 10 μA may prevent the colonisation of catheters by both the extra~ and intra-luminal routes. The localised production of hydrogen peroxide and chlorine and the intrinsic activity due to electric current may offer a useful method for the eradication of bacteria from catheter surfaces.
Resumo:
The aim of this study was to explore two of the mechanisms by which transformational leaders have a positive influence on followers. It examined the mediating role of follower's leader and group identification on the associations among different transformational leader behaviours and follower job satisfaction and supervisor-rated job performance. One hundred and seventy-nine healthcare employees and 44 supervisors participated in the study. The results from multilevel structural equation modelling provided results that partially supported the predicted model. Identification with the leader significantly mediated the positive associations between supportive leadership, intellectual stimulation, personal recognition, in the prediction of job satisfaction and job performance. Leader identification also mediated the relationship between supportive leadership, intellectual stimulation, personal recognition, and group identification. However, group identification did not mediate the associations between vision leadership and inspirational communication, in the prediction of job satisfaction and job performance. The results highlight the role of individualized forms of leadership and leader identification in enhancing follower outcomes.
Resumo:
A simple and cost-effective technique for generating a flat, square-shaped multi-wavelength optical comb with 42.6 GHz line spacing and over 0.5 THz of total bandwidth is presented. A detailed theoretical analysis is presented, showing that using two concatenated modulators driven with voltages of 3.5 Vp are necessary to generate 11 comb lines with a flatness below 2dB. This performance is experimentally demonstrated using two cascaded Versawave 40 Gbit/s low drive voltage electro-optic polarisation modulators, where an 11 channel optical comb with a flatness of 1.9 dB and a side-mode-suppression ratio (SMSR) of 12.6 dB was obtained.
Resumo:
Guided by theory in both the trust and leadership domains, the overarching aim of this thesis was to answer a fundamental question. Namely, how and when does trust-building between leaders and followers enhance leader-member exchange (LMX) development and organisational trust? Although trust is considered to be at the crux of the leader-follower relationship, surprisingly little theoretical or empirical attention has been devoted to understanding the precise nature of this relationship. By integrating both a typology of trustworthy behaviour and a process model of trust development with LMX theory, study one developed and tested a new model of LMX development with leader-follower trust-building as the primary mechanism. In a three wave cross-lagged design, 294 student dyads in a business simulation completed measures of trust perceptions and LMX across the first 6 months of the LMX relationship. Trust-building was found to account for unexplained variance in the LMX construct over time, while controlling for initial relationship quality, thus confirming the critical role of the trust-building process in LMX development. The strongest evidence was found for the role of integrity-based trust-building behaviour, albeit only when such behaviour was not attributed to insincere motives. The results for ability and benevolence-based trustworthy behaviour revealed valued insights into the developmental nature of trustworthiness perceptions within LMX relationships. Thus, the pattern of results in study one provided a more comprehensive and nuanced understanding of the dynamic interplay between trust and LMX. In study two, leader trust-building was investigated cross-sectionally within an organisational sample of 201 employees. The central aim of this study was to investigate whether leader trust-building within leader-follower relationships could be leveraged for organisational trust. As expected, the trust-building process instigated by members in study one was replicated for leaders in study two. In addition, the results were most consistent for benevolence-based trust building, whereas both integrity- and ability-based trust-building were moderated by the position of the leader within the organisation’s hierarchy. Overall, the findings of this thesis shed considerable light on the richness of trusting perceptions in organisations, and the critical role of trust-building in LMX development and organisational trust.
Resumo:
A status report of the modelling and simulation work that is being undertaken as part of the TIMES (Totally Integrated More Electric Systems) project is presented. Dynamic power quality simulations have been used to asses the performance of the electrical system of a EMA based actuation system for an Airbus A330 size aircraft, for both low voltage 115 V, and high voltage 230 V three-phase AC systems. The high voltage system is shown to have benefits in terms of power quality and reduced size and weight of equipment.
Resumo:
A proposal to increase the existing residential LV grid voltage from 230 V to 300 V has been made in order to increase existing network capacity. A power-electronic AC-AC converter is then used to provide 230 V at each property. The equipment can also provide power-quality improvements to the network and load. Several constraints such as temperature rise at the converter location lead to a converter design requiring very high efficiency. In this paper different AC/AC converter topologies are presented which compares the power quality benefits, size and efficiency of each converter. The design and the control technique of the most suitable topology are verified using simulation and preliminary experimentally results of prototype hardware are also included. © 2013 IEEE.
Resumo:
VSC converters are becoming more prevalent for HVDC applications. Two circuits are commercially available at present, a traditional six-switch, PWM inverter, implemented using series connected IGBTs - ABBs HVDC Light®, and the other a modular multi-level converter (MMC) - Siemens HVDC-PLUS. This paper presents an alternative MMC topology, which utilises a novel current injection technique, and exhibits several desirable characteristics.