994 resultados para ultra micro indentation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We experimentally demonstrate locking of a laser frequency to a resonance line of a micro disk resonator. Achieving 1±0.1 pm shifting detection, the approach can be applied for sensing enhancement and perturbation immune NSOM measurements. © OSA 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hot-pressed laminates with a [0/90]48 lay-up, consisting of 83% by volume of ultra high molecular-weight polyethylene (UHMWPE) fibres, and 17% by volume of polyurethane (PU) matrix, were cut into cantilever beams and subjected to transverse end-loading. The collapse mechanisms were observed both visually and by X-ray scans. Short beams deform elastically and collapse plastically in longitudinal shear, with a shear strength comparable to that observed in double notch, interlaminar shear tests. In contrast, long cantilever beams deform in bending and collapse via a plastic hinge at the built-in end of the beam. The plastic hinge is formed by two wedge-shaped microbuckle zones that grow in size and in intensity with increasing hinge rotation. This new mode of microbuckling under macroscopic bending involves both elastic bending and shearing of the plies, and plastic shear of the interface between each ply. The double-wedge pattern contrasts with the more usual parallel-sided plastic microbuckle that occurs in uniaxial compression. Finite element simulations and analytical models give additional insight into the dominant material and geometric parameters that dictate the collapse response of the UHMWPE composite beam in bending. Detailed comparisons between the observed and predicted collapse responses are used in order to construct a constitutive model for laminated UHMWPE composites. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of bicarbonate (HCO3-) on Microcystis aeruginosa FACHB 905 was assessed in this study. Growth curves, chlorophyll a fluorescence and ultrastructure were measured at two HCO3- concentrations, 2.3 mM and 12.4 mM. A treatment of sodium chloride (NaCl) was also conducted alongside to establish the influence level of sodium. It was found that upon treatment with elevated HCO3- concentrations of 2.3 mM and 12.4 mM, cell densities were 13% and 27% (respectively) higher than controls. In photosynthetic performance, elevated HCO3- concentration initially stimulated Fv/Fm at the prophase of culture and then subsequently inhibited it. The inhibition of 2.3mM was higher than that of 12.4mM HCO3-. The maximum relative electron transport rate (ETRmax) exhibited inhibition at elevated HCO3- concentrations. DI0/CS was decreased at 2.3 mM and increased at 12.4mM. In the case of both treatments. ABS/CSI TR0/CS, ET0/CS, RC/CS0 and RC/CSm were decreased by elevated HCO3- concentrations, which indicated damage to photosynthetic apparati and an inactivation of a fraction of reaction centers. This point was also proven by ultrastructural photos. High HCO3--exposed cells lost the characteristic photosynthetic membrane arrangement compared with the control and high salinity treated samples. At the 2.3mM concentration of HCO3-. damage to photosynthetic apparati caused decreased photosynthetic activity. These findings suggested that elevated HCO3- concentration stimulated the growth and photosynthesis of M. aeruginosa FACHB 905 in a short time. Exposure to high HCO3- concentrations for a longer period of time will damage photosynthetic apparatus. In addition, the ultrastructure indicated that elevated HCO3--concentration lead to photosynthetic apparati damage. In our experiment, it was observed that the inhibition effect of 2.3mM HCO3- was higher than that of 12.4mM HCO3-. We hypothesized that M. aeruginosa FACHB 905 induced a protective mechanism under high concentrations of HCO3-.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a high-resolution frequency-output MEMS tilt sensor based on resonant sensing principles. The tilt sensor measures orientation by sensing the component of gravitational acceleration along a specified input axis. A combination of design enhancements enables significantly higher sensitivity for this device as compared to previously reported prototype sensors. The MEMS tilt sensor is calibrated on a manual tilt table over tilt angles ranging over 0-90 degrees with a relatively linear response measured in the range of ±20°(linearity error <2.3%) with a scale factor of approximately 50.06 Hz/degree. The noise-limited resolution of the sensor is found to be approximately 250 nano-radians for an integration time of 0.8 s, which is over an order of magnitude better than previously reported results [1]. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

InGaN micro-light emitting diodes on Si substrates have been fabricated and characterized. Their abilities for micro-display, high modulation bandwidth of 270 MHz and data transmission rate of up to 400 Mbit/s have been demonstrated. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the fabrication of a mechanically-flexible 16×16 array of thin-film, micron-size LEDs emitting at 480 nm. Devices were transfer-printed onto a mechanically-flexible ITO backplane using a modified, high-precision (placement accuracy ±25 nm) assembly system. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human cervix is an important mechanical barrier in pregnancy which must withstand the compressive and tensile forces generated from the growing fetus. Premature cervical shortening resulting from premature cervical remodeling and alterations of cervical material properties are known to increase a woman׳s risk of preterm birth (PTB). To understand the mechanical role of the cervix during pregnancy and to potentially develop indentation techniques for in vivo diagnostics to identify women who are at risk for premature cervical remodeling and thus preterm birth, we developed a spherical indentation technique to measure the time-dependent material properties of human cervical tissue taken from patients undergoing hysterectomy. In this study we present an inverse finite element analysis (IFEA) that optimizes material parameters of a viscoelastic material model to fit the stress-relaxation response of excised tissue slices to spherical indentation. Here we detail our IFEA methodology, report compressive viscoelastic material parameters for cervical tissue slices from nonpregnant (NP) and pregnant (PG) hysterectomy patients, and report slice-by-slice data for whole cervical tissue specimens. The material parameters reported here for human cervical tissue can be used to model the compressive time-dependent behavior of the tissue within a small strain regime of 25%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate the tunability of a silicon nitride micro-resonator using the concept of Digital Microfluidics. Our system allows driving micro-droplets on-chip, enabling the control of the effective refractive index at the vicinity of the resonator. © 2010 OSA/FiO/LS 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We experimentally demonstrate an ultra-thin silicon nitride microring resonator operating at wavelength of 970nm that is favorable for large variety of biophotonic applications. Optimization parameters for improved sensitivity and light-mater interaction are presented. © 2010 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new Enzyme ImmunoAssay (EIA) for PCDD/F TEQ measurement in extracts of environmental samples was described. The bioassay TEQ which derived from EIA and EROD were compared with each other and with results from chemical analysis. For all environmental samples, the EROD-TEQ is higher than the value from chemical analysis. However, the EIA-TEQ is much more identical with the value from chemical analysis. Our results indicate that the EIA assay is a complementary method to the EROD assay and should be useful as a rapid and sensitive screening tool for environmental samples in many situations. (C) 1999 Elsevier Science Ltd. All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We theoretically simulate and experimentally demonstrate ultra-large through-port extinctions in silicon-based asymmetrically-coupled add-drop microring resonators (MRs). Through-port responses in an add-drop MR are analyzed by simulations and large extinctions are found when the MR is near-critically coupled. Accurate fabrication techniques are applied in producing a series of 20 mu m-radii add-drop microrings with drop-side gap-widths in slight differences. A through-port extinction of about 42.7 dB is measured in an MR with through-and drop-side gap-width to be respectively 280 nm and 295 nm. The large extinction suggests about a 20.5 dB improvement from the symmetrical add-drop MR of the same size and the through-side gap-width. The experimental results are finally compared with the post-fabrication simulations, which show a gap-width tolerance of > 30 nm for the through-port extinction enhancement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a sub-nanosecond electro-optical switch with low crosstalk in a silicon-on-insulator (SOI) dual-coupled micro-ring embedded with p-i-n diodes. A crosstalk of -23 dB is obtained in the 20-mu m-radius micro-ring with the well-designing asymmetric dual-coupling structure. By optimizations of the doping profiles and the fabrication processes, the sub-nanosecond switch-on/off time of < 400 ps is finally realized under an electrical pre-emphasized driving signal. This compact and fast-response micro-ring switch, which can be fabricated by complementary metal oxide semiconductor (CMOS) compatible technologies, have enormous potential in optical interconnects of multicore networks-on-chip.