946 resultados para spontaneous ventilation
Resumo:
We report a case of acute facial oedema in an elderly hospitalized patient which was initially misdiagnosed as angioedema secondary to antibiotics in a patient with an allergic diathesis. We describe the differential aetiologies and then the true cause of the oedema, which was an uncommon complication of a very common condition in the elderly: a pneumomediastinum with subcutaneous emphysema probably due to rupture of an emphysematous lung bulla during chronic obstructive pulmonary disease (COPD) exacerbation. Lastly, we focus on the therapeutic procedures instituted for the treatment of the pneumomediastinum.
Resumo:
Autoimmune hepatitis (AIH) is a disease of unknown aetiology with drug-induced AIH being the most complex and not fully understood type. We present the case of a 57-year-old female patient with acute icteric hepatitis after interferon-beta-1b (IFNβ-1b) administration for multiple sclerosis (MS). Based on liver autoimmune serology, histology and appropriate exclusion of other liver diseases, a diagnosis of AIH-related cirrhosis was established. Following discontinuation of IFNβ-1b, a complete resolution of biochemical activity indices was observed and the patient remained untreated on her own decision. However, 3 years later, after a course of intravenous methylprednisolone for MS, a new acute transaminase flare was recorded which subsided again spontaneously after 3 weeks. Liver biopsy and elastography showed significant fibrosis regression (F2 fibrosis). To our knowledge, this is the first report showing spontaneous cirrhosis regression in an IFNβ-1b-induced AIH-like syndrome following drug withdrawal, suggesting that cirrhosis might be reversible if the offending fibrogenic stimulus is withdrawn.
Resumo:
Indoor Air 2016 - The 14th International Conference of Indoor Air Quality and Climate
Resumo:
Non-invasive ventilation (NIV) is the application of a ventilatory support without resorting to invasive methods. Today it’s considered a credible therapeutic option, with enough scientiic evidence to support its application in various situations and clinical settings related to the treatment of acute respiratory disease, as well as chronic respiratory disease. Objectives: Characterize patients undergoing NIV admitted in Unit Intermediate Care (ICU) in the period from October 1st 2015 to June 30th 2016. Methods: Prospective study conducted in ICU between October 2015 and June 2016. In this study were included all patients hospitalized in this unit (ICU) and in that time period a sample of 57 participants was obtained. As data collection instruments we used a questionnaire for sociodemographic and clinical data and the Braden scale. Results: Participants were mostly male 38 (66.7%), the average age 69.5 ± 11.3 years, ranging between 43 and 92 years. They weighed on average 76.6 kg (52 and 150), with an average body mass index of 28.5 kg/m2 (20 to 58.5). With skin intact 28 (49.1%) with abnormal perfusion 12 (21.1%), with altered sensitivity 11 (19.3%) and a high risk of ulcer on the scale of Braden 37 (65%). The admission diagnosis was respiratory failure 33 (57.3%) and had different backgrounds. We used reused mask 53 (93.0%), the average time of NIV was 7.1 days (1-28), 4.8 days of hospitalization (1-18) and an average of 7.8 IPAP pressure. 11 (19.3%) of the participants developed face ulcer pressure.Conclusions: The NIV is used in patients with advanced age, obesity, respiratory failure and high risk of face ulcer development.
Resumo:
In this thesis project, a building in Vegagatan 12, Gävle has been analysed in order to see why it does consume more energy than it was expected. This building is a low energy building certified by Miljöbyggnad and it should use less than 55kWh/m2 year and nowadays it is using 62.23 kWh/m2. To get the needed data, some information about the building has been gathered, some measurements have been done in the building and some calculations have been done with those measurements. Finally, some possible solutions have been offered to reduce the energy use of the building. Insulating the floor, the pipes and the walls, reducing the indoor temperature in winter... All of these changes need the help of environmentally friendly attitudes, which is a very important fact in low energy buildings.
Resumo:
Background: Recurrent spontaneous abortion is one of the diseases that can lead to physical, psychological, and, economical problems for both individuals and society. Recently a few numbers of genetic polymorphisms in kinase insert domain-containing receptor (KDR) gene are examined that can endanger the life of the fetus in pregnant women. Objective: The risk of KDR gene polymorphisms was investigated in Iranian women with idiopathic recurrent spontaneous abortion (RSA). Materials and Methods: A case controlled study was performed. One hundred idiopathic recurrent spontaneous abortion patients with at least two consecutive pregnancy losses before 20 weeks of gestational age with normal karyotypes were included in the study. Also, 100 healthy women with at least one natural pregnancy were studied as control group. Two functional SNPs located in KDR gene; rs1870377 (Q472H), and rs2305948 (V297I) as well as one tag SNP in the intron region (rs6838752) were genotyped by using PCR based restriction fragment length polymorphism (PCR-RFLP) technique. Haplotype frequency was determined for these three SNPs’ genotypes. Analysis of genetic STRUCTURE and K means clustering were performed to study genetic variation. Results: Functional SNP (rs1870377) was highly linked to tag SNP (rs6838752) (D´ value=0. 214; χ2 = 16.44, p<0. 001). K means clustering showed that k = 8 as the best fit for the optimal number of genetic subgroups in our studied materials. This result was in agreement with Neighbor Joining cluster analysis. Conclusion: In our study, the allele and genotype frequencies were not associated with RSA between patient and control individuals. Inconsistent results in different populations with different allele frequencies among RSA patients and controls may be due to ethnic variation and used sample size.
Resumo:
Le nettoyage des systèmes de Chauffage, Ventilation et Climatisation de l’Air est important pour assurer une bonne qualité d’air intérieur. Le déclenchement de leur nettoyage est basé sur une inspection visuelle qui ne tient pas compte du contenu en moisissures, lesquelles ont des effets sur le système respiratoire. Cette recherche vise à proposer une méthode d’évaluation du contenu en moisissures afin d’aider les gestionnaires d’immeuble. Cinq générations de poussières ont été effectuées pour simuler un conduit de ventilation. Une cassette modifiée 37 mm et un filtre CPV pré-pesés ont utilisés pour collecter les poussières déposées avec une pompe calibrée à 15L/min. Les pourcentages de collecte des cassettes et des filtres ont été calculés pour 54 échantillons. Dix générations supplémentaires de poussières ont été effectuées concomitamment avec la génération de spores. Soixante échantillons ont été analysés selon quatre méthodes : culture, comptage direct des spores par microscopie (CDSM), dosage de β-N-acétylhexosaminidase (NAHA), 18S-q-PCR. La limite de détection (LD), la réplicabilité, la répétabilité, le nombre de spores et le coefficient de corrélation (r) ont été déterminés. Les récupérations de poussières étaient supérieures à 84%. Selon la méthode analytique, les concentrations médianes de spores/100 cm² allaient de 10 000 à 815 000. Les LD variaient dépendamment de la méthode de 120 à 218 000 spores/100 cm² et r de -0,08 à 0,83. La réplicabilité et la répétabilité étaient de 1% et 1% pour PCR; 5% et 10% pour CDSM; 6% et 15% pour NAHA; 12% et 11% pour culture. La méthode de collecte a démontré une excellente efficacité de récupération. La PCR est la méthode analytique recommandée pour l’évaluation fongique des systèmes de ventilation. Une validation terrain est en cours.
Resumo:
Introduction: La ventilation non invasive (VNI) est un outil utilisé en soins intensifs pédiatriques (SIP) pour soutenir la détresse respiratoire aigüe. Un échec survient dans près de 25% des cas et une mauvaise synchronisation patient-ventilateur est un des facteurs impliqués. Le mode de ventilation NAVA (neurally adjusted ventilatory assist) est asservi à la demande ventilatoire du patient. L’objectif de cette étude est d’évaluer la faisabilité et la tolérance des enfants à la VNI NAVA et l’impact de son usage sur la synchronie et la demande respiratoire. Méthode: Étude prospective, physiologique, croisée incluant 13 patients nécessitant une VNI dans les SIP de l’hôpital Ste-Justine entre octobre 2011 et mai 2013. Les patients ont été ventilés successivement en VNI conventionnelle (30 minutes), en VNI NAVA (60 minutes) et en VNI conventionnelle (30 minutes). L’activité électrique du diaphragme (AEdi) et la pression des voies aériennes supérieures ont été enregistrées pour évaluer la synchronie. Résultats: La VNI NAVA est faisable et bien tolérée chez tous les enfants. Un adolescent a demandé l’arrêt précoce de l’étude en raison d’anxiété reliée au masque sans fuite. Les délais inspiratoires et expiratoires étaient significativement plus courts en VNI NAVA comparativement aux périodes de VNI conventionnelle (p< 0.05). Les efforts inefficaces étaient moindres en VNI NAVA (résultats présentés en médiane et interquartiles) : 0% (0 - 0) en VNI NAVA vs 12% (4 - 20) en VNI conventionnelle initiale et 6% (2 - 22) en VNI conventionnelle finale (p< 0.01). Globalement, le temps passé en asynchronie a été réduit à 8% (6 - 10) en VNI NAVA, versus 27% (19 - 56) et 32% (21 - 38) en périodes de VNI conventionnelle initiale et finale, respectivement (p= 0.05). Aucune différence en termes de demande respiratoire n’a été observée. Conclusion: La VNI NAVA est faisable et bien tolérée chez les enfants avec détresse respiratoire aigüe et permet une meilleure synchronisation patient-ventilateur. De plus larges études sont nécessaires pour évaluer l’impact clinique de ces résultats.
Resumo:
OBJECTIVE: To estimate the prevalence of spontaneous tinnitus in 11-year-old children. DESIGN: A prospective UK population-based study. STUDY SAMPLE: A total of 7092 children from the Avon longitudinal study of parents and children (ALSPAC) who attended the hearing session at age 11 years and answered questions about tinnitus. RESULTS: We estimated the prevalence of any spontaneous tinnitus as 28.1% (95% CI 27.1, 29.2%), and the prevalence of 'clinically significant' tinnitus as 3.1% (95% CI 2.7, 3.5%). Children were less likely to have clinically significant tinnitus if the tinnitus was 'soft' rather than 'loud' and if continuous rather than intermittent. Clinical significance was more likely if the tinnitus occurred more than once a week. Neither pitch nor length of history were important determinants of clinical significance. Small increases in mean hearing threshold (of up to 2.3 dB HL) were associated with clinically significant tinnitus. CONCLUSIONS: Although the prevalence of any tinnitus in 11-year-old children appears high, the small proportion in which this was found to be clinically significant implies that this does not necessarily indicate a large unmet clinical demand. We would expect approximately one child per class of 30 to have clinically significant tinnitus which is, by definition, problematic.
Resumo:
Le nettoyage des systèmes de Chauffage, Ventilation et Climatisation de l’Air est important pour assurer une bonne qualité d’air intérieur. Le déclenchement de leur nettoyage est basé sur une inspection visuelle qui ne tient pas compte du contenu en moisissures, lesquelles ont des effets sur le système respiratoire. Cette recherche vise à proposer une méthode d’évaluation du contenu en moisissures afin d’aider les gestionnaires d’immeuble. Cinq générations de poussières ont été effectuées pour simuler un conduit de ventilation. Une cassette modifiée 37 mm et un filtre CPV pré-pesés ont utilisés pour collecter les poussières déposées avec une pompe calibrée à 15L/min. Les pourcentages de collecte des cassettes et des filtres ont été calculés pour 54 échantillons. Dix générations supplémentaires de poussières ont été effectuées concomitamment avec la génération de spores. Soixante échantillons ont été analysés selon quatre méthodes : culture, comptage direct des spores par microscopie (CDSM), dosage de β-N-acétylhexosaminidase (NAHA), 18S-q-PCR. La limite de détection (LD), la réplicabilité, la répétabilité, le nombre de spores et le coefficient de corrélation (r) ont été déterminés. Les récupérations de poussières étaient supérieures à 84%. Selon la méthode analytique, les concentrations médianes de spores/100 cm² allaient de 10 000 à 815 000. Les LD variaient dépendamment de la méthode de 120 à 218 000 spores/100 cm² et r de -0,08 à 0,83. La réplicabilité et la répétabilité étaient de 1% et 1% pour PCR; 5% et 10% pour CDSM; 6% et 15% pour NAHA; 12% et 11% pour culture. La méthode de collecte a démontré une excellente efficacité de récupération. La PCR est la méthode analytique recommandée pour l’évaluation fongique des systèmes de ventilation. Une validation terrain est en cours.
Resumo:
Introduction: La ventilation non invasive (VNI) est un outil utilisé en soins intensifs pédiatriques (SIP) pour soutenir la détresse respiratoire aigüe. Un échec survient dans près de 25% des cas et une mauvaise synchronisation patient-ventilateur est un des facteurs impliqués. Le mode de ventilation NAVA (neurally adjusted ventilatory assist) est asservi à la demande ventilatoire du patient. L’objectif de cette étude est d’évaluer la faisabilité et la tolérance des enfants à la VNI NAVA et l’impact de son usage sur la synchronie et la demande respiratoire. Méthode: Étude prospective, physiologique, croisée incluant 13 patients nécessitant une VNI dans les SIP de l’hôpital Ste-Justine entre octobre 2011 et mai 2013. Les patients ont été ventilés successivement en VNI conventionnelle (30 minutes), en VNI NAVA (60 minutes) et en VNI conventionnelle (30 minutes). L’activité électrique du diaphragme (AEdi) et la pression des voies aériennes supérieures ont été enregistrées pour évaluer la synchronie. Résultats: La VNI NAVA est faisable et bien tolérée chez tous les enfants. Un adolescent a demandé l’arrêt précoce de l’étude en raison d’anxiété reliée au masque sans fuite. Les délais inspiratoires et expiratoires étaient significativement plus courts en VNI NAVA comparativement aux périodes de VNI conventionnelle (p< 0.05). Les efforts inefficaces étaient moindres en VNI NAVA (résultats présentés en médiane et interquartiles) : 0% (0 - 0) en VNI NAVA vs 12% (4 - 20) en VNI conventionnelle initiale et 6% (2 - 22) en VNI conventionnelle finale (p< 0.01). Globalement, le temps passé en asynchronie a été réduit à 8% (6 - 10) en VNI NAVA, versus 27% (19 - 56) et 32% (21 - 38) en périodes de VNI conventionnelle initiale et finale, respectivement (p= 0.05). Aucune différence en termes de demande respiratoire n’a été observée. Conclusion: La VNI NAVA est faisable et bien tolérée chez les enfants avec détresse respiratoire aigüe et permet une meilleure synchronisation patient-ventilateur. De plus larges études sont nécessaires pour évaluer l’impact clinique de ces résultats.
Resumo:
Indoor environmental conditions in classrooms, in particular temperature and indoor air quality, influence students’ health, attitude and performance. In recent years, several studies regarding indoor environmental quality of classrooms were published and natural ventilation proved to have great potential, particularly in southern European climate. This research aimed to evaluate indoor environmental conditions in eight schools and to assess their improvement potential by simple natural ventilation strategies. Temperature, relative humidity and carbon dioxide concentration were measured in 32 classrooms. Ventilation performance of the classrooms was characterized using two techniques, first by fan pressurization measurements of the envelope airtightness and later by tracer gas measurements of the air change rate assuming different envelope conditions. A total of 110 tracer gas measurements were made and the results validated ventilation protocols that were tested afterward. The results of the ventilation protocol implementation were encouraging and, overall, a decrease on the CO2 concentration was observed without modifying the comfort conditions. Nevertheless, additional measurements must be performed for winter conditions.
Resumo:
Mechanisms contributing to pulmonary and systemic injury induced by high tidal volume (VT) mechanical ventilation are not well known. We tested the hypothesis that increased peroxynitrite formation is involved in organ injury and dysfunction induced by mechanical ventilation. Male Sprague-Dawley rats were subject to low- (VT, 9 mL/kg; positive end-expiratory pressure, 5 cmH2O) or high- (VT, 25 mL/kg; positive end-expiratory pressure, 0 cmH2O) VT mechanical ventilation for 120 min, and received 1 of 3 treatments: 3-aminobenzamide (3-AB, 10 mg/kg, intravenous, a poly adenosine diphosphate ribose polymerase [PARP] inhibitor), or the metalloporphyrin manganese(III) tetrakis(1-methyl-4-pyridyl)porphyrin (MnTMPyP, 5 mg/kg intravenous, a peroxynitrite scavenger), or no treatment (control group), 30 min before starting the mechanical ventilation protocol (n = 8 per group, 6 treatment groups). We measured mean arterial pressure, peak inspiratory airway pressure, blood chemistry, and gas exchange. Oxidation (fluorescence for oxidized dihydroethidium), protein nitration (immunofluorescence and Western blot for 3-nitrotyrosine), PARP protein (Western blot) and gene expression of the nitric oxide (NO) synthase (NOS) isoforms (quantitative real-time reverse transcription polymerase chain reaction) were measured in lung and vascular tissue. Lung injury was quantified by light microscopy. High-VT mechanical ventilation was associated with hypotension, increased peak inspiratory airway pressure, worsened oxygenation; oxidation and protein nitration in lung and aortic tissue; increased PARP protein in lung; up-regulation of NOS isoforms in lung tissue; signs of diffuse alveolar damage at histological examination. Treatment with 3AB or MnTMPyP attenuated the high-VT mechanical ventilation-induced changes in pulmonary and cardiovascular function; down-regulated the expression of NOS1, NOS2, and NOS3; decreased oxidation and nitration in lung and aortic tissue; and attenuated histological changes. Increased peroxynitrite formation is involved in mechanical ventilation-induced pulmonary and vascular dysfunction.
Resumo:
The benefits of prone position ventilation are well demonstrated in the severe forms of acute respiratory distress syndrome, but not in the milder forms. We investigated the effects of prone position on arterial blood gases, lung inflammation, and histology in an experimental mild acute lung injury (ALI) model. ALI was induced in Wistar rats by intraperitoneal Escherichia coli lipopolysaccharide (LPS, 5 mg/kg). After 24 h, the animals with PaO2/FIO2 between 200 and 300 mmHg were randomized into 2 groups: prone position (n = 6) and supine position (n = 6). Both groups were compared with a control group (n = 5) that was ventilated in the supine position. All of the groups were ventilated for 1 h with volume-controlled ventilation mode (tidal volume = 6 ml/kg, respiratory rate = 80 breaths/min, positive end-expiratory pressure = 5 cmH2O, inspired oxygen fraction = 1). Significantly higher lung injury scores were observed in the LPS-supine group compared to the LPS-prone and control groups (0.32 ± 0.03; 0.17 ± 0.03 and 0.13 ± 0.04, respectively) (p < 0.001), mainly due to a higher neutrophil infiltration level in the interstitial space and more proteinaceous debris that filled the airspaces. Similar differences were observed when the gravity-dependent lung regions and non-dependent lung regions were analyzed separately (p < 0.05). The BAL neutrophil content was also higher in the LPS-supine group compared to the LPS-prone and control groups (p < 0.05). There were no significant differences in the wet/dry ratio and gas exchange levels. In this experimental extrapulmonary mild ALI model, prone position ventilation for 1 h, when compared with supine position ventilation, was associated with lower lung inflammation and injury.