912 resultados para side illumination fluorescence


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study describes the use of micro synchrotron radiation X-ray fluorescence (µSR-XRF) to investigate citrus greening disease in sweet orange (Citrus sinensis) plants. An experiment using healthy plants as control and plants of the same variety infected with Candidatus Liberibacter asiaticus (CLas) was performed to verify variations of the mineral composition of citrus leaves. A µSR-XRF system using the D09B X-ray fluorescence beam line at the Brazilian Synchrotron Light Source (LNLS, Campinas, São Paulo State) was employed for this purpose. The data were analyzed using a chemometric tool called soft independent modelling of class analogy (SIMCA). The promising results from SIMCA models reinforce the evidence that plants infected by citrus greening (both asymptomatic and symptomatic) undergo alterations in their micro- and macronutrient compositions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Covalent “click” cycloaddition was used to functionalize silica substrates with pH-sensitive nanoparticles, thus producing uniform and highly luminescent analytical devices usable in both commercial fluorimeters and fluorescence microscopes. Quantitative and spatially-resolved extracellular pH measurements were successfully achieved on live cardiac fibroblasts with these novel ion-sensitive surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. Materials and Methods: A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen's weighted kappa values. Results: For permanent teeth, the LFpen cut‑off were 0– 27 (sound), 28– 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0– 7 (sound), 8– 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW) for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth. Conclusion: LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This manuscript describes the use of a tooth indicated for extraction due
to orthodontic reasons as an anchorage aid to receive undesirable side effects caused by orthodontic uprighting of a contralateral molar tooth. The mandibular right second molar was mesially tipped as a result of loss of the adjacent first molar. Since the treatment plan involved extraction of the mandibular left first premolar, undesirable side effects associated with the molar uprighting movement were transferred to this tooth. Once the second molar was vertical, the premolar was extracted and the treatment continued. The results suggest that treatment time can be reduced if undesirable orthodontic mechanical side effects can be directed to a tooth whose extraction is indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human dentition is naturally translucent, opalescent and fluorescent. Differences between the level of fluorescence of tooth structure and restorative materials may result in distinct metameric properties and consequently perceptible disparate esthetic behavior, which impairs the esthetic result of the restorations, frustrating both patients and staff. In this study, we evaluated the level of fluorescence of different composites (Durafill in tones A2 (Du), Charisma in tones A2 (Ch), Venus in tone A2 (Ve), Opallis enamel and dentin in tones A2 (OPD and OPE), Point 4 in tones A2 (P4), Z100 in tones A2 ( Z1), Z250 in tones A2 (Z2), Te-Econom in tones A2 (TE), Tetric Ceram in tones A2 (TC), Tetric Ceram N in tones A1, A2, A4 (TN1, TN2, TN4), Four seasons enamel and dentin in tones A2 (and 4SD 4SE), Empress Direct enamel and dentin in tones A2 (EDE and EDD) and Brilliant in tones A2 (Br)). Cylindrical specimens were prepared, coded and photographed in a standardized manner with a Canon EOS digital camera (400 ISO, 2.8 aperture and 1/ 30 speed), in a dark environment under the action of UV light (25 W). The images were analyzed with the software ScanWhite©-DMC/Darwin systems. The results showed statistical differences between the groups (p < 0.05), and between these same groups and the average fluorescence of the dentition of young (18 to 25 years) and adults (40 to 45 years) taken as control. It can be concluded that: Composites Z100, Z250 (3M ESPE) and Point 4 (Kerr) do not match with the fluorescence of human dentition and the fluorescence of the materials was found to be affected by their own tone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Elderly patients generally use several types of medication, some of which may cause oral side effects. Aim: To investigate the oral side effects caused by medication in an elderly sample. Methods: Three hundred patients were interviewed about their use of medication and were divided in two groups: institutionalized (n=150) and community-dwelling (n=150) elderly. Results: The most used drugs were antihypertensives (53%) for community-dwelling elders and antiulceratives (76%) for the institutionalized ones. The more prevalent side effects were taste alterations that occurred in 19%, dry mouth in 17% and teeth staining in 2%. Conclusions: A high prevalence of oral side effects from medications used by the elderly was found in this study. The health professionals should be aware of the possible side effects caused by prescribed medications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The steady-state average run length is used to measure the performance of the recently proposed synthetic double sampling (X) over bar chart (synthetic DS chart). The overall performance of the DS X chart in signaling process mean shifts of different magnitudes does not improve when it is integrated with the conforming run length chart, except when the integrated charts are designed to offer very high protection against false alarms, and the use of large samples is prohibitive. The synthetic chart signals when a second point falls beyond the control limits, no matter whether one of them falls above the centerline and the other falls below it; with the side-sensitive feature, the synthetic chart does not signal when they fall on opposite sides of the centerline. We also investigated the steady-state average run length of the side-sensitive synthetic DS X chart. With the side-sensitive feature, the overall performance of the synthetic DS X chart improves, but not enough to outperform the non-synthetic DS X chart. Copyright (C) 2014 John Wiley &Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chlorophyll fluorescence is currently used as a rapid diagnostic and nondestructive method to detect and quantify damage on the photosynthetic apparatus of leaves on weeds, crops and ornamental/coniferous trees in response to both environmental stress and herbicides. This study aimed to evaluate chlorophyll fluorescence in guanandi plants (Calophyllum brasiliense) after application of different postemergence herbicides. The experiment was performed in a completely randomized design, with six treatments (control, bentazon, sulfentrazone, isoxaflutole, atrazine and glyphosate) and five replications. The herbicide treatments were applied with a stationary sprayer, and electron transport rate (ETR) was subsequently analyzed with OS5p Multi-Mode Chlorophyll Fluorometer. In the monitored period, guanandi plants subjected to atrazine showed higher sensitivity to chlorophyll fluorescence than the other treatments. Although bentazon is a photosystem II inhibitor, it showed no major changes in electron transport for the studied species and in the monitored period. In summary, ETR is a good parameter to evaluate the effect of some herbicides on Calophyllum brasiliense plants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accidents or diseases can affect the peripheral part of the nervous system, which raises clinical and surgical therapies, among others. In this context, the technique of end-to-side neurorrhaphy is a treatment option, yet its modification loop needs some additional efficacy studies. The purpose of this study was to compare, among rats, stereological results (axons volume density) after end-to-side neurorrhaphy and after end-to-side loop neurorrhaphy. Thirty Wistar rats were used, divided into six groups (five animals per group), consisting of two control groups (for the fibular and tibial nerves), two study groups for the fibular nerve (one with an end-to-side neurorrhaphy, and the other with an end-to-side loop neurorrhaphy) and two study groups for the tibial nerve (with an endto- side neurorrhaphy and the other one with an end-to-side loop neurorrhaphy). After 180 days, all groups were sacrificed for axonal stereological analysis (volume density) in distal nerve stumps. There was significant maintenance of neuronal-axonal density in the distal stumps to neurorrhaphy (p< 0.005) compared with the normal stumps. The end-to-side loop neurorrhaphy is a therapeutic option as suture technique after complete nerve section, in order to restore most of the axonal functional integrity.