989 resultados para sample correlation
Resumo:
A study was undertaken by the Bituminous Research Laboratory of the Engineering Research Institute at Iowa State University, under the sponsorship of the Iowa Highway Research Board, project HR 100, to ascertain the effects of a number of characteristics and properties of asphaltic concrete mixes upon the service behavior of the mixes as evaluated by the Traffic Simulator and by field observations. The study included: Investigations of the relations, of gradation, fraction and resistance to wear of aggregates; of stability, cohesion, per cent voids and asphalt content: of a number of laboratory and field mixes to service behavior as indicated by the Traffic Simulator under various test conditions. Based upon the results of the tests and the relationships noted, tentative criteria for the Traffic Simulator test were devised, subject to verification by observations and measurements of field service behavior of the mixes.
Resumo:
Transmission electron microscopy is a proven technique in the field of cell biology and a very useful tool in biomedical research. Innovation and improvements in equipment together with the introduction of new technology have allowed us to improve our knowledge of biological tissues, to visualizestructures better and both to identify and to locate molecules. Of all the types ofmicroscopy exploited to date, electron microscopy is the one with the mostadvantageous resolution limit and therefore it is a very efficient technique fordeciphering the cell architecture and relating it to function. This chapter aims toprovide an overview of the most important techniques that we can apply to abiological sample, tissue or cells, to observe it with an electron microscope, fromthe most conventional to the latest generation. Processes and concepts aredefined, and the advantages and disadvantages of each technique are assessedalong with the image and information that we can obtain by using each one ofthem.
Resumo:
The main scope of this work was to detect (Panicum maximum Jacq.) genotype differences as to morphoagronomic and seed quality indices, and to establish character correlations useful for determining vegetative and reproductive trends. Besides the flowering cycle, eight phenological and two seed quality traits were scored in a greenhouse randomized complete block experiment, as follows: plant height (PH), reproductive tiller number/overall tiller number (RTN/OTN), panicle number/reproductive tillers (PN/RT), leaf length (LL), leaf width (LW), panicle length (PL), fresh weight (FW), dry weight (DW), number of seeds/g (NS/G) and seed sample physical purity (SPP). Very-early and early-flowering hybrids consistently showed the highest correlation values among flowering cycle and RTN/OTN (r = -0.59**), PN/RT (r = -0.48**), NS/G (r = -0.88**) and SPP (r = -0.80**) (reproductive parameters) while intermediate and late-flowering hybrids presented the highest values for LL (r = 0.53**), LW (r = 0.60**), PL (r = 0.77**), FW (r = 0.78**) and DW (r = 0.85**) (vegetative traits). The implications of these results for plant breeding and forage management purposes are discussed.
Resumo:
In order to distinguish dysfunctional gait; clinicians require a measure of reference gait parameters for each population. This study provided normative values for widely used parameters in more than 1400 able-bodied adults over the age of 65. We also measured the foot clearance parameters (i.e., height of the foot above ground during swing phase) that are crucial to understand the complex relationship between gait and falls as well as obstacle negotiation strategies. We used a shoe-worn inertial sensor on each foot and previously validated algorithms to extract the gait parameters during 20 m walking trials in a corridor at a self-selected pace. We investigated the difference of the gait parameters between male and female participants by considering the effect of age and height factors. Besides; we examined the inter-relation of the clearance parameters with the gait speed. The sample size and breadth of gait parameters provided in this study offer a unique reference resource for the researchers.
Resumo:
OBJECTIVE: This study examined the respective roles of personal and environmental factors in youth violence in a nationally representative sample of 7548 postmandatory school students and apprentices ages 16-20 years in Switzerland. METHODS: Youth violence was defined as having committed at least one of the following in the previous 12 months: attacking an adult, snatching something, carrying a weapon, or using a weapon in a fight. Different ecological levels were tested, resulting in a three-level model only in males (individual, classroom, and school) as the low prevalence of female violence did not allow for a multilevel analysis. Dependent variables were attributed to each level. For males, the classroom level (10%) and the school level (24%) accounted for more than one third in interindividual variance. RESULTS: Factors associated with violence perpetration in females were being a victim of physical violence and sensation seeking at the individual level. In males, practicing unsafe sex, sensation seeking, being a victim of physical violence, having a poor relationship with parents, being depressed, and living in a single-parent household at the individual level; violence and antisocial acts at the classroom level; and being in a vocational school at the school level showed a correlation with violence perpetration. CONCLUSION: Interventions at the classroom level as well as an explicit school policy on violence and other risk behaviors should be considered a priority when dealing with the problem of youth violence. Furthermore, prevention should take into account gender differences.
Resumo:
A headspace solid-phase microextraction procedure (HS-SPME) was developed for the profiling of traces present in 3,4-methylenedioxymethylampethamine (MDMA). Traces were first extracted using HS-SPME and then analyzed by gas chromatography-mass spectroscopy (GC-MS). The HS-SPME conditions were optimized using varying conditions. Optimal results were obtained when 40 mg of crushed MDMA sample was heated at 80 °C for 15 min, followed by extraction at 80 °C for 15 min with a polydimethylsiloxane/divinylbenzene coated fibre. A total of 31 compounds were identified as traces related to MDMA synthesis, namely precursors, intermediates or by-products. In addition some fatty acids used as tabletting materials and caffeine used as adulterant, were also detected. The use of a restricted set of 10 target compounds was also proposed for developing a screening tool for clustering samples having close profile. 114 seizures were analyzed using an SPME auto-sampler (MultiPurpose Samples MPS2), purchased from Gerstel GMBH & Co. (Germany), and coupled to GC-MS. The data was handled using various pre-treatment methods, followed by the study of similarities between sample pairs based on the Pearson correlation. The results show that HS-SPME, coupled with the suitable statistical method is a powerful tool for distinguishing specimens coming from the same seizure and specimens coming from different seizures. This information can be used by law enforcement personnel to visualize the ecstasy distribution network as well as the clandestine tablet manufacturing.
Resumo:
Aims: Plasma concentrations of imatinib differ largely between patients despite same dosage, owing to large inter-individual variability in pharmacokinetic (PK) parameters. As the drug concentration at the end of the dosage interval (Cmin) correlates with treatment response and tolerability, monitoring of Cmin is suggested for therapeutic drug monitoring (TDM) of imatinib. Due to logistic difficulties, random sampling during the dosage interval is however often performed in clinical practice, thus rendering the respective results not informative regarding Cmin values.Objectives: (I) To extrapolate randomly measured imatinib concentrations to more informative Cmin using classical Bayesian forecasting. (II) To extend the classical Bayesian method to account for correlation between PK parameters. (III) To evaluate the predictive performance of both methods.Methods: 31 paired blood samples (random and trough levels) were obtained from 19 cancer patients under imatinib. Two Bayesian maximum a posteriori (MAP) methods were implemented: (A) a classical method ignoring correlation between PK parameters, and (B) an extended one accounting for correlation. Both methods were applied to estimate individual PK parameters, conditional on random observations and covariate-adjusted priors from a population PK model. The PK parameter estimates were used to calculate trough levels. Relative prediction errors (PE) were analyzed to evaluate accuracy (one-sample t-test) and to compare precision between the methods (F-test to compare variances).Results: Both Bayesian MAP methods allowed non-biased predictions of individual Cmin compared to observations: (A) - 7% mean PE (CI95% - 18 to 4 %, p = 0.15) and (B) - 4% mean PE (CI95% - 18 to 10 %, p = 0.69). Relative standard deviations of actual observations from predictions were 22% (A) and 30% (B), i.e. comparable to the intraindividual variability reported. Precision was not improved by taking into account correlation between PK parameters (p = 0.22).Conclusion: Clinical interpretation of randomly measured imatinib concentrations can be assisted by Bayesian extrapolation to maximum likelihood Cmin. Classical Bayesian estimation can be applied for TDM without the need to include correlation between PK parameters. Both methods could be adapted in the future to evaluate other individual pharmacokinetic measures correlated to clinical outcomes, such as area under the curve(AUC).
Resumo:
This paper proposes new methodologies for evaluating out-of-sample forecastingperformance that are robust to the choice of the estimation window size. The methodologies involve evaluating the predictive ability of forecasting models over a wide rangeof window sizes. We show that the tests proposed in the literature may lack the powerto detect predictive ability and might be subject to data snooping across differentwindow sizes if used repeatedly. An empirical application shows the usefulness of themethodologies for evaluating exchange rate models' forecasting ability.
Resumo:
The aim of this work is to present a new concept, called on-line desorption of dried blood spots (on-line DBS), allowing the direct analysis of a dried blood spot coupled to liquid chromatography mass spectrometry device (LC/MS). The system is based on an inox cell which can receive a blood sample (10 microL) previously spotted on a filter paper. The cell is then integrated into LC/MS system where the analytes are desorbed out of the paper towards a column switching system ensuring the purification and separation of the compounds before their detection on a single quadrupole MS coupled to atmospheric pressure chemical ionisation (APCI) source. The described procedure implies that no pretreatment is necessary in spite the analysis is based on whole blood sample. To ensure the applicability of the concept, saquinavir, imipramine, and verapamil were chosen. Despite the use of a small sampling volume and a single quadrupole detector, on-line DBS allowed the analyses of these three compounds over their therapeutic concentrations from 50 to 500 ng/mL for imipramine and verapamil and from 100 to 1000 ng/mL for saquinavir. Moreover, the method showed good repeatability with relative standard deviation (RSD) lower than 15% based on two levels of concentration (low and high). Function responses were found to be linear over the therapeutic concentration for each compound and were used to determine the concentrations of real patient samples for saquinavir. Comparison of the founded values with those of a validated method used routinely in a reference laboratory showed a good correlation between the two methods. Moreover, good selectivity was observed ensuring that no endogenous or chemical components interfered with the quantitation of the analytes. This work demonstrates the feasibility and applicability of the on-line DBS procedure for bioanalysis.
Resumo:
The presence of a calling and career development are assumed to be closely related. However, the nature of and reason for this relationship have not been thoroughly investigated. We hypothesized the existence of reciprocal effects between calling and three dimensions of career preparation and assessed the change of the presence of a calling, career planning, decidedness, and self-efficacy with three waves of a diverse sample of German university students (N = 846) over one year. Latent growth analyses revealed that the intercepts of calling showed a significant positive correlation with the intercepts of all career preparation measures. The slope of calling was positively related to those of decidedness and self-efficacy but not to planning. Cross-lagged analyses showed that calling predicted a subsequent increase in planning and self-efficacy. Planning and decidedness predicted an increase in the presence of a calling. The results suggest that calling and career preparation are related due to mutual effects but that effects differ for different career preparation dimensions.
Resumo:
Capillary electrophoresis has drawn considerable attention in the past few years, particularly in the field of chiral separations because of its high separation efficiency. However, its routine use in therapeutic drug monitoring is hampered by its low sensitivity due to a short optical path. We have developed a capillary zone electrophoresis (CZE) method using 2mM of hydroxypropyl-β-cyclodextrin as a chiral selector, which allows base-to-base separation of the enantiomers of mianserin (MIA), desmethylmianserin (DMIA), and 8-hydroxymianserin (OHMIA). Through the use of an on-column sample concentration step after liquid-liquid extraction from plasma and through the presence of an internal standard, the quantitation limits were found to be 5 ng/mL for each enantiomer of MIA and DMIA and 15 ng/mL for each enantiomer of OHMIA. To our knowledge, this is the first published CE method that allows its use for therapeutic monitoring of antidepressants due to its sensitivity down to the low nanogram range. The variability of the assays, as assessed by the coefficients of variation (CV) measured at two concentrations for each substance, ranged from 2 to 14% for the intraday (eight replicates) and from 5 to 14% for the interday (eight replicates) experiments. The deviations from the theoretical concentrations, which represent the accuracy of the method, were all within 12.5%. A linear response was obtained for all compounds within the range of concentrations used for the calibration curves (10-150 ng/mL for each enantiomer of MIA and DMIA and 20-300 ng/mL for each enantiomer of OHMIA). Good correlations were calculated between [(R) + (S)]-MIA and DMIA concentrations measured in plasma samples of 20 patients by a nonchiral gas chromatography method and CZE, and between the (R)- and (S)-concentrations of MIA and DMIA measured in plasma samples of 37 patients by a previously described chiral high-performance liquid chromatography method and CZE. Finally, no interference was noted from more than 20 other psychotropic drugs. Thus, this method, which is both sensitive and selective, can be routinely used for therapeutic monitoring of the enantiomers of MIA and its metabolites. It could be very useful due to the demonstrated interindividual variability of the stereoselective metabolism of MIA.
Resumo:
A simple method determining airborne monoethanolamine has been developed. Monoethanolamine determination has traditionally been difficult due to analytical separation problems. Even in recent sophisticated methods, this difficulty remains as the major issue often resulting in time-consuming sample preparations. Impregnated glass fiber filters were used for sampling. Desorption of monoethanolamine was followed by capillary GC analysis and nitrogen phosphorous selective detection. Separation was achieved using a specific column for monoethanolamines (35% diphenyl and 65% dimethyl polysiloxane). The internal standard was quinoline. Derivatization steps were not needed. The calibration range was 0.5-80 μg/mL with a good correlation (R(2) = 0.996). Averaged overall precisions and accuracies were 4.8% and -7.8% for intraday (n = 30), and 10.5% and -5.9% for interday (n = 72). Mean recovery from spiked filters was 92.8% for the intraday variation, and 94.1% for the interday variation. Monoethanolamine on stored spiked filters was stable for at least 4 weeks at 5°C. This newly developed method was used among professional cleaners and air concentrations (n = 4) were 0.42 and 0.17 mg/m(3) for personal and 0.23 and 0.43 mg/m(3) for stationary measurements. The monoethanolamine air concentration method described here was simple, sensitive, and convenient both in terms of sampling and analytical analysis.
Resumo:
Understanding the influence of pore space characteristics on the hydraulic conductivity and spectral induced polarization (SIP) response is critical for establishing relationships between the electrical and hydrological properties of surficial unconsolidated sedimentary deposits, which host the bulk of the world's readily accessible groundwater resources. Here, we present the results of laboratory SIP measurements on industrial-grade, saturated quartz samples with granulometric characteristics ranging from fine sand to fine gravel, which can be regarded as proxies for widespread alluvial deposits. We altered the pore space characteristics by changing (i) the grain size spectra, (ii) the degree of compaction, and (iii) the level of sorting. We then examined how these changes affect the SIP response, the hydraulic conductivity, and the specific surface area of the considered samples. In general, the results indicate a clear connection between the SIP response and the granulometric as well as pore space characteristics. In particular, we observe a systematic correlation between the hydraulic conductivity and the relaxation time of the Cole-Cole model describing the observed SIP effect for the entire range of considered grain sizes. The results do, however, also indicate that the detailed nature of these relations depends strongly on variations in the pore space characteristics, such as, for example, the degree of compaction. The results of this study underline the complexity of the origin of the SIP signal as well as the difficulty to relate it to a single structural factor of a studied sample, and hence raise some fundamental questions with regard to the practical use of SIP measurements as site- and/or sample-independent predictors of the hydraulic conductivity.
Resumo:
Intraclass correlation (ICC) is an established tool to assess inter-rater reliability. In a seminal paper published in 1979, Shrout and Fleiss considered three statistical models for inter-rater reliability data with a balanced design. In their first two models, an infinite population of raters was considered, whereas in their third model, the raters in the sample were considered to be the whole population of raters. In the present paper, we show that the two distinct estimates of ICC developed for the first two models can both be applied to the third model and we discuss their different interpretations in this context.