896 resultados para results measure
Resumo:
The unique physical and movement characteristics of children necessitate the development of accelerometer equations and cut points that are population specific. The purpose of this study is to develop an ecologically valid cut point for the Biotrainer Pro monitor that reflects a threshold for moderate-intensity physical activity in elementary school children. A sample of 30 children (ages 8-12) wore a Biotrainer monitor while completing a series of 7 movement tasks (calibration phase) and while participating in an organized group activity (cross-validation phase). Videotapes from each session were processed using a computerized direct-observation technique to provide a criterion measure of physical activity. Analyses involved the use of mixed-model regression and receiver operator characteristic (ROC) curves. The results indicated that a cut point of 4 counts/min provides the optimal balance between the related needs for sensitivity (accurately detecting activity) and specificity (limiting misclassification of activity as inactivity). Results with the cross-validation data demonstrated that this value yielded the best overall kappa (.58) and a high classification agreement (84%) for activity determination. The specificity of 93% demonstrates that the proposed cut point can accurately detect activity; however, the lower sensitivity value of 61% suggests that some minutes of activity might be incorrectly classified as inactivity. The cut point of 4 counts/min provides an ecologically valid cut point to capture physical activity in children using the Biotrainer Pro activity monitor.
Resumo:
Purpose: To investigate the changes in axial length with the combined effect of accommodation and angle of gaze (convergence and downward gaze) over 5 minutes in groups of myopes and emmetropes. Methods: A total of 31 subjects (nine emmetropes, 10 low myopes, and 12 moderate to high myopes) aged from 18 to 31 years were recruited. To measure ocular biometrics in inferonasal gaze with accommodation, an optical biometer (Lenstar LS900) was inclined on a tilt and height adjustable stage, with the subject’s chinrest mounted on a rotary stage to induce various levels of convergence by rotation of the subject’s head in primary or downward gaze. Initially, the subjects performed a distance viewing task in primary gaze for 10 minutes to provide a ‘wash-out’ period for prior visual tasks, and then the subject’s axial length and ocular biometrics were measured in nine different combinations of gaze/accommodation over 5 minutes. These nine sessions for all gaze measurements (i.e. three levels of accommodation 9 three levels of convergence) were completed across 3 days of testing (one accommodation condition on each day).The nine combinations of gaze/accommodation were based on those required to view the centre, right and left edges of a distant TV at 6 m in primary gaze, an intermediate task (i.e. computer at 50 cm in 10° downward gaze) and a near task (i.e. reading A4 page at 20 cm in 20° downward gaze). Subjects were wearing a custom built three-axes head tracker throughout the experiment that monitored subjects’ relative head movements (roll, pitch and yaw) during measurements. Results: A significant increase in axial length occurred with the combined effect of accommodation, convergence and downward gaze (repeated measures ANOVA, p < 0.001), with the greatest axial elongation during the near task in downward gaze with convergence (i.e. downward 20°/inward 33°, with 5 D accommodation) (mean change 33 ± 13 lm, after 5 minutes task) followed by the intermediate task (i.e. downward 10°/inward 25°, with 2 D accommodation) (mean change 14 ± 11 lm, after 5 minutes task).Changes in axial length for the distance task (i.e. primary gaze/9° convergence, with 0.16 D accommodation) were not statistically significant (mean change 4 ± 8 lm, after 5 minutes task, p > 0.05). Moderate to high myopes had a greater change in the axial length (mean change 40 ± 11 lm after 5 minutes of near task) than that of emmetropes (mean change 29 ± 15 lm after 5 minutes of near task) and low myopes (mean change 29 ± 16 lm after 5 minutes of near task) associated with time (p = 0.02) and accommodation by time (p = 0.03). Conclusions: The combination of accommodation, convergence and downward angle has a significant short term effect on axial length over time. The near task in downward gaze with convergence caused a greater change in axial length than the intermediate and distant visual tasks. The greater axial elongation measured in the infero-nasal direction with accommodation is most likely associated with a combination of biomechanical factors such as, extraocular muscle forces and ciliary muscle contraction.
Resumo:
OBJECTIVES To describe protocol and interobserver agreements of an instrument to evaluate nutrition and physical activity environments at child care. METHODS Interobserver data were collected from 9 child care centers, through direct observation and document review (17 observer pairs). RESULTS Mean agreement between observer pairs was 87.26% and 79.29% for the observation and document review, respectively. Items with lower agreement were primarily staff behavior, counting across the day/week, and policy classifications. CONCLUSIONS Although some revisions are required, the interobserver agreement for the environment and policy assessment and observation (EPAO instrument) appears to be quite good for assessing the nutrition and physical activity environment of child care centers.
Resumo:
Purpose To test the effects of a community-based physical activity intervention designed to increase physical activity and to conduct an extensive process evaluation of the intervention. Design Quasi-experimental. Setting Two rural communities in South Carolina. One community received the intervention, and the other served as the comparison. Subjects Public school students who were in fifth grade at the start of the study (558 at baseline) were eligible to participate. A total of 436 students participated over the course of the study. Intervention The intervention included after-school and summer physical activity programs and home, school, and community components designed to increase physical activity in youth. The intervention took place over an 18-month period. Measures. Students reported after-school physical activity at three data collection points (prior to, during, and following the intervention) using the Previous Day Physical Activity Recall (PDPAR). They also completed a questionnaire designed to measure hypothesized psychosocial and environmental determinants of physical activity behavior The process evaluation used meeting records, documentation of program activities, interviews, focus groups, and heart rate monitoring to evaluate the planning and implementation of the intervention. Results There were no significant differences in the physical activity variables and few significant differences in the psychosocial variables between the intervention and comparison groups. The process evaluation indicated that the after-school and summer physical activity component of the intervention was implemented as planned, but because of resource and time limitations, the home, school, and community components were not implemented as planned. Conclusions The intervention did not have a significant effect on physical activity in the target population of children in the intervention community. This outcome is similar to that reported in other studies of community-based physical activity intervention.
Resumo:
To evaluate the validity of the ActiGraph accelerometer for the measurement of physical activity intensity in children and adolescents with cerebral palsy (CP) using oxygen uptake (VO 2) as the criterion measure. Thirty children and adolescents with CP (mean age 12.6 ± 2.0 years) wore an ActiGraph 7164 and a Cosmed K4b 2 portable indirect calorimeter during four activities; quiet sitting, comfortable paced walking, brisk paced walking and fast paced walking. VO 2 was converted to METs and activity energy expenditure and classiWed as sedentary, light or moderate-to-vigorous intensity according to the conventions for children. Mean ActiGraph counts min -1 were classiWed as sedentary, light or moderate-to-vigorous (MVPA) intensity using four diVerent sets of cut-points. VO 2 and counts min¡1 increased signiWcantly with increases in walking speed (P < 0.001). Receiver operating characteristic (ROC) curve analysis indicated that, of the four sets of cut-points evaluated, the Evenson et al. (J Sports Sci 26(14):1557-1565, 2008) cut-points had the highest classiWcation accuracy for sedentary (92%) and MVPA (91%), as well as the second highest classiWcation accuracy for light intensity physical activity (67%). A ROC curve analysis of data from our participants yielded a CP-speciWc cut-point for MVPA that was lower than the Evenson cut-point (2,012 vs. 2,296 counts min¡1), however, the diVerence in classiWcation accuracy was not statistically signiWcant 94% (95% CI = 88.2-97.7%) vs. 91% (95% CI = 83.5-96.5%). In conclusion, among children and adolescents with CP, the ActiGraph is able to diVerentiate between diVerent intensities of walking. The use of the Evenson cut-points will permit the estimation of time spent in MVPA and allows comparisons to be made between activity measured in typically developing adolescents and adolescents with CP. © 2011 Springer-Verlag.
Resumo:
Objective The present study aimed to develop accelerometer cut points to classify physical activities (PA) by intensity in preschoolers and to investigate discrepancies in PA levels when applying various accelerometer cut points. Methods To calibrate the accelerometer, 18 preschoolers (5.8 +/- 0.4 years) performed eleven structured activities and one free play session while wearing a GT1M ActiGraph accelerometer using 15 s epochs. The structured activities were chosen based on the direct observation system Children's Activity Rating Scale (CARS) while the criterion measure of PA intensity during free play was provided using a second-by-second observation protocol (modified CARS). Receiver Operating Characteristic (ROC) curve analyses were used to determine the accelerometer cut points. To examine the classification differences, accelerometer data of four consecutive days from 114 preschoolers (5.5 +/- 0.3 years) were classified by intensity according to previously published and the newly developed accelerometer cut points. Differences in predicted PA levels were evaluated using repeated measures ANOVA and Chi Square test. Results Cut points were identified at 373 counts/15 s for light (sensitivity: 86%; specificity: 91%; Area under ROC curve: 0.95), 585 counts/15 s for moderate (87%; 82%; 0.91) and 881 counts/15 s for vigorous PA (88%; 91%; 0.94). Further, applying various accelerometer cut points to the same data resulted in statistically and biologically significant differences in PA. Conclusions Accelerometer cut points were developed with good discriminatory power for differentiating between PA levels in preschoolers and the choice of accelerometer cut points can result in large discrepancies.
Resumo:
Dietitians have reported a lack of confidence in counselling clients with mental health issues. Standardised tools are needed to evaluate programs aiming to improve confidence. The Dietetic Confidence Scale (DCS) was developed to assess dietitians’perception of their capability about working with clients experiencing depression. Exploratory research revealed a 13-item, two-factor model. Dietetic confidence was associated with: 1) Confidence using the Nutrition Care Process; and 2) Confidence in Advocacy for Self-care and Client-care. This study aimed to validate the DCS using this two-factor model.The DCS was administered to 458 dietitians. Confirmatory factor analysis (CFA) assessed the scale’s psychometric validity. Reliability was measured using Cronbach’s alpha (α) co-efficient. CFA results supported the hypothesised two-factor, 13-item model. The Good Fit Index (GFI = 0.95) indicated a strong fit. Item-factor correlations ranged from r = 0.50 to 0.89. The overall scale and subscales showed good reliability (α = 0.93 to 0.76). This is the first study to validate an instrument that measures dietetic confidence about working with clients experiencing depression. The DCS can be used to measure changes in perceived confidence and identify where further training, mentoring or experience is needed. The findings also suggest that initiatives aimed at building dietitians' confidence about working with clients experiencing depression, should focus on improving client-focused nutrition care, foster advocacy, reflective practice, mentoring and encourage professional support networks. Avenues for future research include further validity and reliability testing to expand the generalisability of results; and modifying the scale for other disease or client populations.
Resumo:
In the TREC Web Diversity track, novelty-biased cumulative gain (α-NDCG) is one of the official measures to assess retrieval performance of IR systems. The measure is characterised by a parameter, α, the effect of which has not been thoroughly investigated. We find that common settings of α, i.e. α=0.5, may prevent the measure from behaving as desired when evaluating result diversification. This is because it excessively penalises systems that cover many intents while it rewards those that redundantly cover only few intents. This issue is crucial since it highly influences systems at top ranks. We revisit our previously proposed threshold, suggesting α be set on a query-basis. The intuitiveness of the measure is then studied by examining actual rankings from TREC 09-10 Web track submissions. By varying α according to our query-based threshold, the discriminative power of α-NDCG is not harmed and in fact, our approach improves α-NDCG's robustness. Experimental results show that the threshold for α can turn the measure to be more intuitive than using its common settings.
Resumo:
Background Promoting participation physical activity (PA) is an important means of promoting healthy growth and development in children with cerebral palsy (CP). The ActiGraph is a uniaxial accelerometer that provides a realtime measure of PA intensity, duration and frequency. Its small, light weight design makes it a promising measure of activity in children with CP. To date no study has validated the use of accelerometry as a measure of PA in ambulant adolescents with CP. Objectives To evaluate the validity of the ActiGraph accelerometer for measuring PA intensity in adolescents with CP, using oxygen consumption (VO2), measured using portable indirect calorimetry (Cosmed K4b2), as the criterion measure. Design Validation Study Participants/Setting: Ambulant adolescents with CP aged 10–16 years, GMFCS rating of I-III. The recruitment target is 30 (10 in each GMFCS level). Materials/Methods Participants wore the ActiGraph (counts/min) and a Cosmed K4b2 indirect calorimeter (mL/kg/min) during six activity trials: quiet sitting (QS), comfortable paced walking (CPW), brisk paced walking (BPW), fast paced walking (FPW), a ball-kicking protocol (KP) and a ball-throwing protocol (TP). MET levels (multiples of resting metabolism) for each activity were predicted from ActiGraph counts using the Freedson age-specific equation (Freedson et al. 2005) and compared with actual MET levels measured by the Cosmed. Predicted and measured METs for each activity trial were classified as light (> 1.5 METs and <4.6 METs) or moderate to vigorous intensity (≥ 4.6 METs). Results To date 36 bouts of activity have been completed (6 participants x 6 activities). Mean VO2 increased linearly as the intensity of the walking activity increased (CPW=9.47±2.16, BPW=14.06±4.38, FPW=19.21±5.68 ml/kg/min) and ActiGraph counts reflected this pattern (CPW=1099±574, BPW=2233±797 FPW=4707±1013 counts/min). The throwing protocol recording the lowest VO2 (TP=7.50±3.86 ml/kg/min) and lowest overall counts/min (TP=31±27 counts/min). When each of the 36 bouts were classified as either light or moderate to vigorous intensity using measured VO2 as the criterion measure, the Freedson equation correctly classified 28 from 36 bouts (78%). Conclusion/Clinical Implications These preliminary findings suggest that there is a relationship between the intensity of PA and direct measure of oxygen consumption and that therefore the ActiGraph may be a promising tool for accurately measuring free living PA in the community. Further data collection of the complete sample will enable secondary analysis of the relationship between PA and severity of CP (GMFCS level).
Resumo:
PURPOSE Accurate monitoring of prevalence and trends in population levels of physical activity is fundamental to the planning of health promotion and disease-prevention strategies. Test-retest reliability (repeatability) was assessed for four self-report measures of physical activity commonly used in population surveys: the Active Australia survey (AA, N=356), the short form of the International Physical Activity Questionnaire (IPAQ-S, N=104), the physical activity items in the Behavioral Risk Factor Surveillance System (BRFSS, N=127) and the physical activity items in the Australian National Health Survey (NHS, N=122). METHODS Percent agreement and Kappa statistics were used to assess the reliability of classification of activity status (where ‘active’= 150 minutes of activity per week) and sedentariness (where ‘sedentary’ = reporting no physical activity). Intraclass correlations (ICCs) were used to assess agreement on minutes of activity reported for each item of each survey and on total minutes reported in each survey. RESULTS Percent agreement scores for both activity status and sedentariness were very good on all four instruments. Overall the percent agreement between repeated surveys was between 73% (NHS) and 87% (IPAQ) for the criterion measure of achieving 150 minutes per week, and between 77% (NHS) and 89% (IPAQ) for the criterion of being sedentary. Corresponding Kappa statistics ranged from 0.46 (NHS) to 0.61 (AA) for activity status and from 0.20 (BRFSS) to 0.52 (AA) for sedentariness. For the individual items ICCs were highest for walking (0.45 to 0.56) and vigorous activity (0.22 to 0.64) and lowest for the moderate questions (0.16 to 0.44). CONCLUSION All four measures provide acceptable levels of test-retest reliability for assessing both activity status and sedentariness, and moderate reliability for assessing total minutes of activity. Supported by the Australian Commonwealth Department of Health and Ageing.