999 resultados para radiografia torácica


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The atlantoaxial subluxation or luxation is an instability of this articulation that produces excessive flexion of this joint causing the cranial aspect of the axis to rotate dorsally into the vertebral channel with subsequent spinal cord compression. This disorder is most commonly found in young small breed dogs. The diagnosis of this disease is done by survey radiographs, where there is a larger distance between the atlas dorsal arch and the axis spinal process characterize the atlantoaxial subluxation. Surgical stabilization is the treatment of choice and multiple implants show the best results to stabilize the atlantoaxial joint. The main complications are sudden death or implant failure. The sudden death happens because of cardiorespiratory arrest and it is most likely caused by brainstem iatrogenic trauma. However, a larger study comparing different surgical stabilization techniques should be performed to evaluate relative success rates in dogs that have the same initial neurologic status

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O uso de radiações ionizantes (R.I.), nas mais variadas atividades tem aumentado nas últimas décadas. Com o avanço tecnológico, novos e sofisticados equipamentos emissores de R.I. tem surgido no cenário nacional, o que torna imperativo a difusão do conhecimento sobre os conceitos de proteção radiológica junto à comunidade em geral, e neste sentido, o curso de física médica desenvolve um importante papel, quer seja no aspecto informativo quanto formativo de cidadãos e profissionais críticos e politicamente corretos, que possam contribuir com as Políticas Públicos dos órgãos normatizadores e fiscalizadores das atividades de vigilância sanitária. Conforme a legislação atual (Resolução SS-625 de 14/12/1994, da Secretaria de Estado da Saúde, e Portaria 453 de 01/06/1998 da Vigilância Sanitária do Ministério da Saúde), todos os serviços que utilizam radiações ionizantes devem realizar testes de avaliação dos parâmetros radiométricos dos equipamentos emissores de R.I., sendo exigidos as medidas de Levantamento Radiométrico das instalações, o Teste de Radiação de Fuga do cabeçote emissor e a implementação de Programa de Garantia de Qualidade dos equipamentos e dos procedimentos radiológicos. Este procedimento tem como objetivo principal a obtenção de imagens radiográficas com qualidade e a segurança de pacientes e profissionais, evitando a exposição desnecessária à radiação de pacientes e profissionais. A correta realização de procedimentos radiológicos além de reduzir a dose nos pacientes também promove significativa diminuição nos custos, por não haver necessidade da repetição dos exames. No Brasil, conforme dados da Secretaria de Atenção à Saúde SAS/MS, atualmente existem instalados 4.469 mamógrafos, 25.930 aparelhos de raios-x médicos, 39.438 aparelhos de raios-x odontológicos e...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Legg-Calvé-Perthes disease is a non-inflammatory aseptic necrosis of the head of the femur that is found in both young animals and humans before the gap in the femur head closes. In the fields of both human and veterinary medicine the cause of this condition is not known for certain. Various factors have been put forward in the literature as being responsible for the incidence of this condition such as: abnormalities in coagulation, changes in blood flow in the arteries, a septic obstruction in the draining of the epiphysis or the upper parts of the femur, trauma, growth cycle, hyperactivity in a child, genetic influences and dietary factors. Case histories in dogs show that the first stages of the condition progress slowly but that limping or putting weight on the limb worsens at 6 to 8 weeks. Some owners talk about a sharp onset in clinical lameness. Other clinical symptoms may include irritability, loss of appetite and knawing at the hair surrounding the affected hip. In the course of physical examination manipulating the hip joint will cause pain to the animal. The advanced stages of the disease may result in restricted amplitude of movement, muscular atrophy and fracturing. In humans the clinical signs are similar, although progression of the disease is slower so that it can be diagnosed at an earlier stage. In veterinary medicine the diagnosis is, in the main, based on case history, clinical symptoms, physical examination and certain related procedures such as radiography. The various diagnoses include physical trauma and dislocation of the medial patella. In human medicine many people have been correctly diagnosed. Whatsmore, there is a range of related procedures that are virtually not available to veterinary medicine such as magnetic nuclear resonance, that show up necroses with great clarity before radiography and cintilography do, and is considered... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to synthesize the manganese and zinc ferrite, by the polymeric precursor method, in order to obtain materials with appropriate characteristics for the application in medical diagnosis techniques. The manganese and zinc ferrite powders with the composition of Mn(1-x)ZnxFe2O4, where x=0,23, were prepared and calcined in air at different times and temperatures. The X-ray diffraction (XRD) data show that the sample calcined at 400°C crystallize as ferrite (monophase), but in an inverted spinel structure (high content of iron occupying manganese tetrahedral site and manganese occupying the iron octahedral site). The samples calcined at temperatures between 600°C and 900°C shows the secondary phase of hematite and the sample calcined at 1100oC shows to be monophase in ferrite with normal spinel structure. The monophase powders of ferrite showed a reduction in the surface area and an increasing in the pore size for higher calcination temperatures. The magnetic analysis show that the sample calcined at 400°C presents satisfactory magnetization at room temperature, however, it behaves as diamagnetic material at low temperatures (10K). The powder containing hematite, without the partial substitution of iron ions by manganese, showed to have low transition temperature, and consequently low magnetization at room temperature. The hematite, when partially substituted, provides materials with irregular magnetization at the saturation region. The powder calcined at 1100°C shows high magnetization either at room temperature or low temperature (10K)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Biosusceptometry AC (BAC) is a research tool that has been extensively explored by the group Biomagnetism IBB-UNESP for monitoring of the gastrointestinal tract, its response to a known drug or in vivo performance of solid dosage forms. During this period the BAC, which has the characteristics of high sensitivity and low cost, has been developed primarily for recording signals contraction of activity and traffic human gastrointestinal tract. With the possibility of producing images with this instrumentation, it was possible to evaluate different situations in vitro and in vivo for physiological studies and pharmaceuticals. Considering the good performance of this system to produce planar images, the first aim of the BAC system tomography (TBAC) was to evaluate the system performance of BAC to produce tomographic images of phantoms ferromagnetic for a single channel system. All these applications were only possible because of their sensitivity to materials of high magnetic suscepitibility as ferrite, which allow to produce an electrical signal proportional to the variation of the magnetic flux generated by the presence of magnetic marker next to a first-order gradiometer. Measuring this variation at various points was possible to generate planar images that recently came to be produced in systems with multiple detectors, said multi-channels. From planar images, also producing tomographic images of simulators BAC bars in a system of 13 channels using only the center channel, with good results when applied to simple objects as one and two bars. When testing the resolution of the system with more elaborate forms the quality and resolution of images reconstructed is not satisfactory, which would be solved by increasing the spatial sampling rate and hence the acquisition time. The present system works with an acquisition time of about five hours. Whereas this system will be applied for in vivo experiments, the acquisition time became a ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiography is currently an important method of diagnosis, both medical, dental and veterinary. The image in this type of survey is obtained using an X-ray beam, where the radiologist can possibly view structures of interest. It isn't always possible to get the desired images due to various factors, such as equipment limitations. The Administrative Law 453/98, the State Resolution SS 625/94, and other standards require testing and quality control acceptance limits that guarantee a good performance of the equipment for the security and quality of care, giving service users greater effectiveness in exams. This study were performed in the accompaniment of testing procedures for quality control established by Administrative Law 453/98 in several X-ray equipment to make a comparison and optimization in the descriptions of the procedures used by the Institute for Electrical Energy and the University of São Paulo (IEE / USP / SP).The optimization of the procedures were performed with the aid of a current literature, the Resolution 453/98, State Resolution SS 625/94 and other international standards. On this basis it was possible to observe the importance of regular monitoring of tests for an update, following the technological development of instruments used in the service

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Imaging diagnosis is a medical specialty that uses imaging techniques to perform diagnosis. In diagnostic imaging various methods are used such as direct absorption of photons - SPA and DPA, radiographic photometry, the dual-energy radiographic absorptiometry - DEXA, ultrasound, magnetic resonance imaging, computed tomography and optical densitometry in radiographic image. The dog can be considered one of the most widely used animals in the study of bone diseases and searching for a reliable diagnosis, although not an ideal model for the study of osteoporosis, because these animals tend not to develop a decrease in bone mineral density. The objective of this study was to analyze bone density in mongrel dogs from the determination of the variation of density along the radio-ulna bone and also the mean value related to gender, weight and age of individuals. The density analysis carried out showed that for this data set, there is a significant difference in the case of gender and age of the animal and may generalize according to these variables. The only significant difference was found in the weight, which increases bone mass is related to weight gain through the growth of the animal

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project aims the verification of doses in canines and felines to chest and coxal exams due to the transition from screen-film to computed radiography system. It also seeks a possible optimization of the new techniques employed in this new system. The study was carried out in Diagnostic Imaging service in Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo using a conventional x-ray equipment. Initially, data about the physical characteristics of animals and the technique currently used in computed radiography was collected for each of 80 chest and 16 coxal X-ray examinations. The animals were divided into different groups according to the body weight. For each group, were calculated the averages of each item: thickness of the region to be imaged, voltage, current, exposure time, current-time product, size of film used, presence or absence of bucky and focus (small or large). The techniques have been reproduced in phantoms (representative of the thickness of the animal) in order to collect the air kerma entrance. Based on the average of intermediate size M group (weights less than 5 kg for cats and from 10.1 kg and 20 kg for dogs) analysis of image quality using three devices test patterns were made consisting of the evaluation of spatial resolution, low-contrast resolution and contrast-detail. In general, the results showed the dose animals decreased with the use of computed radiography and was possible to preliminary optimization of some techniques used currently in CR

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Scoliosis is a three-dimensional deformity and it can be influenced by the use of shoe lifts and lateral inclination in order to correct postural asymmetries. OBJECTIVE: To verify the effect of the use of the shoe lifts (lower and high) unilateral (right and left) during the movement of lateral inclination (right and left) for an evaluation of the postural angles in patients with idiopathic scoliosis. METHODS: A control group with ten participants without scoliosis and an experimental group with 10 participants with idiopathic scoliosis of double curves (thoracic right and lumbar to the left). Ten reflexive markers were fixed in the spine to determine the postural angles (alpha 1=T2T4-T4T6, alpha 2=T6T8-T8T10, alpha 3=T10T12-T12L2 and alpha 4=L2L4-L4S1)... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Computed Radiography (CR) is a term used to describe the system that electronically records a radiographic image. CR systems use receivers or IP (imaging plate) to capture the analog signals and then allow the readers to do the image processing and converted into digital information. With the increasing expansion of the CR for medical diagnostics it is necessary that these systems receive the same type of monitoring related to Quality Control and Acceptance to the conventional processing systems. The current legislation fails to specify the parameters and procedures to be tested, allowing that somehow, some equipment is not fully able to use in clinical routine. In this project we used the standard AAPM Report Number 93, which is already fully established outside the country and displays all test parameters in CR. From there were chosen three types of tests that were performed in a satisfactory sampling of IP´s. With this procedure it was possible to establish which of those IP's should be out of use, which reveals the important purpose of the study, demonstrating the need for Quality Control Testing and Acceptance in Computerized Radiography as soon as possible are included in the legislation regulator in the country

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A proposta desse trabalho surgiu da possibilidade de unir metodologias eficientes para estabelecer valores mais precisos de densitometria óssea. A densidade óssea é um parâmetro biofísico de grande importância experimental e clínica, que permite avaliar o processo de mineralização óssea. O objetivo deste trabalho foi determinar a densidade óssea e o coeficiente de atenuação de massa da radiação gama com o radioisótopo 241Am com fotopico de 59,6 keV em rádios de cães SRD (Sem Raça Definida). Conclui-se a que a densidade média das amostras foi de 1,91 g/cm³ com um desvio padrão de 0,0599. Para o coeficiente de atenuação de massa, o valor médio foi de 0,241 cm2/g, com desvio padrão de 0,0151. Para ambos os parâmetros o coeficiente de variação foi pequeno implicando em uma baixa dispersão. Isso também demonstra que os métodos aplicados foram eficientes e de fácil aplicabilidade

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study analyzed contours of the thoracic region of patients undergoing radiotherapy of breast tumors in Hospital Manuel de Abreu of Bauru (institution 1) and the Hospital da Faculdade de Medicina of Botucatu (Institution 2). Were prepared isodose curves corresponding to the contours of the patient, which were presented for radiotherapists doctors both hospital services that enabled the choice of the curve isodose that provides the best distribution of radiation dose in the irradiated volume. Some boundaries were digitized in one institution and sent for preparation of isodose lines in the institution 2, both curves plotted in each of the institutions and for the same contour, were compared, showing that the methodology of Curves of distance is feasible and reliable, while optimizing the routine procedures regarding the handling of isodose plans provided by different radiation equipment. It compares the calculation of the exposure time determined using the isodose curve selected by calculating the value obtained considering the PDP at the point of the middle line of separation between the internal and external fields, the difference between the two methods for determining exposure time was around 2.4%. A study on the angle of the radiation beam at the input field (region breast-air) was conducted showing that, once known a tangent angle of the input beam, one can estimate the angle of the wedge filter used in some procedures for uniformity of dose within the irradiated volume compensation and the lack of tissue in the treatment volume. A comparative study between the isodose curves produced manually with the curves obtained in a two-dimensional computer system, the computer system showed that provides further information regarding the dose gradient within the irradiated volume, in addition to reducing the time spent in preparing the curves isodose

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study was performed to verify if there are changes in salivary pH in patients with hyperhidrosis who were treated by Videothoracoscopic Sympathectomy. Twelve patients underwent sympathectomy with clamping the sympathetic chain along the vertebrae T2, T3 and T4, under inhalation and intravenous general anesthesia and with drainage of pneumothorax through probe N° 16. These patients had their saliva collected 1 day before and 7 days after surgery for measurement of pH by the colorimetric method with indicator paper. All patients showed no sign or symptom of hyperhidrosis in the immediate postoperative period, which demonstrates the success of sympathetic denervation on these levels. No patient had compensatory sweating and there was no post-operatively surgical complication. No drug or substance has been administered to patients for the study. The pH results obtained were analyzed using test ´´t´´ Student. Although the average pH in samples obtained after surgery was lower than the preoperative, the test revealed no statistically significant difference (p = 0.181). It is concluded that sympathectomy, an excellent therapeutic and definitive method for hyperhidrosis, does not alter the salivary pH, and so, did not influence the cariogenic process