956 resultados para radioactive ion beam line


Relevância:

30.00% 30.00%

Publicador:

Resumo:

For more than 4 years, gaseous samples of 1-50 mu g carbon have been routinely measured with the gas ion source of the small AMS (Accelerator Mass Spectrometer) facility MICADAS (Mini CArbon DAting System) at ETH Zurich. The applied measurement technique offers a simple and fast way of C-14 measurements without the need of sample graphitization. A major drawback of gaseous C-14 measurements, however, is the relatively low negative ion current, which results in longer measurement times and lower precision compared to graphitized samples. In December 2009, a new, improved Cs sputter ion source was installed at MICADAS and we began to optimize conditions for the measurement of gaseous samples. C-12(-) currents from the new ion source were improved from initially 3 to 12-15 mu A for routine measurements and the negative ion yield was increased by a factor of 2, reaching 8 on average during routine operation. Moreover, the new measurement settings enable a doubled CO2 flow, thus substantially reducing measurement times. The achieved performance allows closing the sample size gap between gaseous and solid samples and makes the gas ion source a promising tool for dating with a measurement precision of 5 parts per thousand on samples as small as 50 mu g carbon. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In 2010 more than 600 radiocarbon samples were measured with the gas ion source at the MIni CArbon DAting System (MICADAS) at ETH Zurich and the number of measurements is rising quickly. While most samples contain less than 50 mu g C at present, the gas ion source is attractive as well for larger samples because the time-consuming graphitization is omitted. Additionally, modern samples are now measured down to 5 per-mill counting statistics in less than 30 min with the recently improved gas ion source. In the versatile gas handling system, a stepping-motor-driven syringe presses a mixture of helium and sample CO2 into the gas ion source, allowing continuous and stable measurements of different kinds of samples. CO2 can be provided in four different ways to the versatile gas interface. As a primary method. CO2 is delivered in glass or quartz ampoules. In this case, the CO2 is released in an automated ampoule cracker with 8 positions for individual samples. Secondly, OX-1 and blank gas in helium can be provided to the syringe by directly connecting gas bottles to the gas interface at the stage of the cracker. Thirdly, solid samples can be combusted in an elemental analyzer or in a thermo-optical OC/EC aerosol analyzer where the produced CO2 is transferred to the syringe via a zeolite trap for gas concentration. As a fourth method, CO2 is released from carbonates with phosphoric acid in septum-sealed vials and loaded onto the same trap used for the elemental analyzer. All four methods allow complete automation of the measurement, even though minor user input is presently still required. Details on the setup, versatility and applications of the gas handling system are given. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mass spectrometric analysis of elemental and isotopic compositions of several NIST standards is performed by a miniature laser ablation/ionisation reflectron-type time-of-flight mass spectrometer (LMS) using a fs-laser ablation ion source (775 nm, 190 fs, 1 kHz). The results of the mass spectrometric studies indicate that in a defined range of laser irradiance (fluence) and for a certain number of accumulations of single laser shot spectra, the measurements of isotope abundances can be conducted with a measurement accuracy at the per mill level and at the per cent level for isotope concentrations higher and lower than 100 ppm, respectively. Also the elemental analysis can be performed with a good accuracy. The LMS instrument combined with a fs-laser ablation ion source exhibits similar detection efficiency for both metallic and non-metallic elements. Relative sensitivity coefficients were determined and found to be close to one, which is of considerable importance for the development of standard-less instruments. Negligible thermal effects, sample damage and excellent characteristics of the fs-laser beam are thought to be the main reason for substantial improvement of the instrumental performance compared to other laser ablation mass spectrometers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Calcium ionophore, ionomycin, and phorbol myristate acetate (PMA) were used to activate rabbit peripheral blood B cells to study the role of increased intracellular calcium ion concentration ( (Ca$\sp2+\rbrack\sb{\rm i}$), protein kinase C (PKC) activation, and autocrine interleukin (IL-2) in inducing cell cycle entry and maintaining activation to DNA synthesis. When stimulated with a combination of ionomycin and PMA the B cells produced a soluble factor that supported the IL-2 dependent cell line, CTLL-2. The identity of the factor was established as IL-2 and its source was proved to be B cells in further experiments. Absorption studies and limiting dilution analysis indicated that IL-2 produced by B cells can act as an autocrine growth factor. Next, the effect of complete and incomplete signalling on B lymphocyte activation leading to cell cycle entry, IL-2 production, functional IL-2 receptor (IL-2R) expression, and DNA synthesis was examined. It was observed that cell cycle entry could be induced by signals provided by each reagent alone, but IL-2 production, IL-2R expression, and progression to DNA synthesis required activation with both reagents. Incomplete activation with ionomycin or PMA alone altered the responsiveness of B cells to further stimulation only in the case of ionomycin, and the unresponsiveness of these cells was apparently due to a lack of functional IL-2R expression on these cells, even though IL-2 production was maintained. The requirement of IL-2 for maintenance of activation to DNA synthesis was then investigated. The hypothesis that IL-2, acts in late G$\sb1$ and is required for DNA synthesis in B cells was supported by comparing IL-2 production and DNA synthesis in peripheral blood cells and purified B cells, kinetic analysis of these events in B cells, effects of anti-IL-2 antibody and PKC inhibitors, and by the response of G$\sb1$ B cells. Additional signals transduced by the interaction of autocrine IL-2 and functional IL-2 receptor on rabbit B cells were found to be necessary to drive these cells to S phase, after initial activation caused by simultaneous increase in (Ca$\sp2+\rbrack\sb{\rm i}$ and PKC activation had induced cell cycle entry, IL-2 production, and functional IL-2 receptor expression. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A three-dimensional model has been proposed that uses Monte Carlo and fast Fourier transform convolution techniques to calculate the dose distribution from a fast neutron beam. This method transports scattered neutrons and photons in the forward, lateral, and backward directions and protons, electrons, and positrons in the forward and lateral directions by convolving energy spread kernels with initial interaction available energy distributions. The primary neutron and photon spectrums have been derived from narrow beam attenuation measurements. The positions and strengths of the effective primary neutron, scattered neutron, and photon sources have been derived from dual ion chamber measurements. The size of the effective primary neutron source has been measured using a copper activation technique. Heterogeneous tissue calculations require a weighted sum of two convolutions for each component since the kernels must be invariant for FFT convolution. Comparisons between calculations and measurements were performed for several water and heterogeneous phantom geometries. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Parameningeal rhabdomyosarcomas (PM-RMSs) represent approximately 25% of all rhabdomyosarcoma (RMS) cases. These tumors are associated with early recurrence and poor prognosis. This study assessed the clinical outcome and late toxicity of pencil beam scanning (PBS) proton therapy (PT) in the treatment of children with PM-RMS. PROCEDURES Thirty-nine children with PM-RMS received neoadjuvant chemotherapy followed by PBS-PT at the Paul Scherrer Institute, with concomitant chemotherapy. The median age was 5.8 years (range, 1.2-16.1). Due to young age, 25 patients (64%) required general anesthesia during PT. The median time from the start of chemotherapy to PT was 13 weeks (range, 3-23 weeks). Median prescription dose was 54 Gy (relative biologic effectiveness, RBE). RESULTS With a mean follow-up of 41 months (range, 9-106 months), 10 patients failed. The actuarial 5-year progression-free survival (PFS) was 72% (95% CI, 67-94%) and the 5-year overall survival was 73% (95% CI, 69-96%). On univariate analysis, a delay in the initiation of PT (>13 weeks) was a significant detrimental factor for PFS. Three (8%) patients presented with grade 3 radiation-induced toxicity. The estimated actuarial 5-year toxicity ≥grade 3 free survival was 95% (95% CI, 94-96%). CONCLUSIONS Our data contribute to the growing body of evidence demonstrating the safety and effectiveness of PT for pediatric patients with PM-RMS. These preliminary results are encouraging and in line with other combined proton-photon and photons series; observed toxicity was acceptable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of this study was to test the hypothesis that the aggregated state of natural marine particles constrains the sensitivity of optical beam attenuation to particle size. An instrumented bottom tripod was deployed at the 12-m node of the Martha's Vineyard Coastal Observatory to monitor particle size distributions, particle size-versus-settling-velocity relationships, and the beam attenuation coefficient (c(p)) in the bottom boundary layer in September 2007. An automated in situ filtration system on the tripod collected 24 direct estimates of suspended particulate mass (SPM) during each of five deployments. On a sampling interval of 5 min, data from a Sequoia Scientific LISST 100x Type B were merged with data from a digital floc camera to generate suspended particle volume size distributions spanning diameters from approximately 2 mu m to 4 cm. Diameter-dependent densities were calculated from size-versus-settling-velocity data, allowing conversion of the volume size distributions to mass distributions, which were used to estimate SPM every 5 min. Estimated SPM and measured c(p) from the LISST 100x were linearly correlated throughout the experiment, despite wide variations in particle size. The slope of the line, which is the ratio of c(p) to SPM, was 0.22 g m(-2). Individual estimates of c(p):SPM were between 0.2 and 0.4 g m(-2) for volumetric median particle diameters ranging from 10 to 150 mu m. The wide range of values in c(p):SPM in the literature likely results from three factors capable of producing factor-of-two variability in the ratio: particle size, particle composition, and the finite acceptance angle of commercial beam-transmissometers.