952 resultados para performance testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In spite of their wide application in comminution circuits, hydrocyclones have at least one significant disadvantage in that their operation inherently tends to return the fine denser liberated minerals to the grinding mill. This results in unnecessary overgrinding which adds to the milling cost and can adversely affect the efficiency of downstream processes. In an attempt to solve this problem, a three-product cyclone has been developed at the Julius Kruttschnitt Mineral Research Centre (JKMRC) to generate a second overflow in which the fine dense liberated minerals can be selectively concentrated for further treatment. In this paper, the design and operation of the three-product cyclone are described. The influence of the length of the second vortex finder on the performance of a 150-mm unit treating a mixture of magnetite and silica is investigated. Conventional cyclone tests were also conducted under similar conditions. Using the operational performance data of the three-product and conventional cyclones, it is shown that by optimising the length of the second vortex finder, the amount of fine dense mineral particles that reports to the three-product cyclone underflow can be reduced. In addition, the three-product cyclone can be used to generate middlings stream that may be more suitable for flash flotation than the conventional cyclone underflow, or alternatively, could be classified with a microscreen to separate the valuables from the gangue. At the same time, a fines stream having similar properties to those of the conventional overflow can be obtained. Hence, if the middlings stream was used as feed for flash flotation or microscreening, the fines stream could be used in lieu of the conventional overflow without compromising the feed requirements for the conventional flotation circuit. Some of the other potential applications of the new cyclone are described. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As end-user computing becomes more pervasive, an organization's success increasingly depends on the ability of end-users, usually in managerial positions, to extract appropriate data from both internal and external sources. Many of these data sources include or are derived from the organization's accounting information systems. Managerial end-users with different personal characteristics and approaches are likely to compose queries of differing levels of accuracy when searching the data contained within these accounting information systems. This research investigates how cognitive style elements of personality influence managerial end-user performance in database querying tasks. A laboratory experiment was conducted in which participants generated queries to retrieve information from an accounting information system to satisfy typical information requirements. The experiment investigated the influence of personality on the accuracy of queries of varying degrees of complexity. Relying on the Myers–Briggs personality instrument, results show that perceiving individuals (as opposed to judging individuals) who rely on intuition (as opposed to sensing) composed queries more accurately. As expected, query complexity and academic performance also explain the success of data extraction tasks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose. This study evaluated an electromyographic technique for the measurement of muscle activity of the deep cervical flexor (DCF) muscles. Electromyographic signals were detected from the DCF, sternocleidomastoid (SCM), and anterior scalene (AS) muscles during performance of the craniocervical flexion (CCF) test, which involves performing 5 stages of increasing craniocervical flexion range of motion-the anatomical action of the DCF muscles. Subjects. Ten volunteers without known pathology or impairment participated in this study. Methods. Root-mean-square (RMS) values were calculated for the DCF, SCM, and AS muscles during performance of the CCF test. Myoelectric signals were recorded from the DCF muscles using bipolar electrodes placed over the posterior oropharyngeal wall. Reliability estimates of normalized RMS values were obtained by evaluating intraclass correlation coefficients and the normalized standard error of the mean (SEM). Results. A linear relationship was evident between the amplitude of DCF muscle activity and the incremental stages of the CCF test (F=239.04, df=36, P<.0001). Normalized SEMs in the range 6.7% to 10.3% were obtained for the normalized RMS values for the DCF muscles, providing evidence of reliability for these variables. Discussion and Conclusion. This approach for obtaining a direct measure of the DCF muscles, which differs from those previously used, may be useful for the examination of these muscles in future electromyographic applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A more efficient classifying cyclone (CC) for fine particle classification has been developed in recent years at the JKMRC. The novel CC, known as the JKCC, has modified profiles of the cyclone body, vortex finder, and spigot when compared to conventional hydrocyclones. The novel design increases the centrifugal force inside the cyclone and mitigates the short circuiting flow that exists in all current cyclones. It also decreases the probability of particle contamination in the place near the cyclone spigot. Consequently the cyclone efficiency is improved while the unit maintains a simple structure. An international patent has been granted for this novel cyclone design. In the first development stage-a feasibility study-a 100 mm JKCC was tested and compared with two 100 min commercial units. Very encouraging results were achieved, indicating good potential for the novel design. In the second development stage-a scale-up stage-the JKCC was scaled up to 200 mm in diameter, and its geometry was optimized through numerous tests. The performance of the JKCC was compared with a 150 nun commercial unit and exhibited sharper separation, finer separation size, and lower flow ratios. The JKCC is now being scaled up into a fill-size (480 mm) hydrocyclone in the third development stage-an industrial study. The 480 mm diameter unit will be tested in an Australian coal preparation plant, and directly compared with a commercial CC operating under the same conditions. Classifying cyclone performance for fine coal could be further improved if the unit is installed in an inclined position. The study using the 200 mm JKCC has revealed that sharpness of separation improved and the flow ratio to underflow was decreased by 43% as the cyclone inclination was varied from the vertical position (0degrees) to the horizontal position (90degrees). The separation size was not affected, although the feed rate was slightly decreased. To ensure self-emptying upon shutdown, it is recommended that the JKCC be installed at an inclination of 75-80degrees. At this angle the cyclone performance is very similar to that at a horizontal position. Similar findings have been derived from the testing of a conventional hydrocyclone. This may be of benefit to operations that require improved performance from their classifying cyclones in terms of sharpness of separation and flow ratio, while tolerating slightly reduced feed rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of type of grain (wheat vs. sorghum) and oil supplement/kg diet [0, 20g olive oil (OL), 20g safflower oil (SO), 10 g OL plus 10 g SO (OLSO)], over a 12-week period on the performance, plasma and lipoproteins lipids [cholesterol (C), triglycerides (TG), phospholipid (P)], and yolk C and fatty acids concentrations of laying hens were studied. Hens fed on the sorghum diet had significantly (P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two experiments using a temporal occlusion paradigm (the first with expert and novice participants and the second with participants of intermediate skill) were conducted to examine the capability of tennis players to predict the direction of an opponent's service in situ. In both experiments two different response conditions, reflecting differing degrees of perception-action coupling, were employed. In a coupled condition players were required to make a movement-based response identical to that which they would use to hit a return of service in a game situation, whereas in an uncoupled condition a verbal prediction of service direction was required. Experiment 1 provided clear evidence of superior prediction accuracy under the coupled response condition when ball flight was available, plus some limited evidence to suggest that superior prediction accuracy under uncoupled response conditions might hold true if only advance (pre-contact) information was available. Experiment 2 showed the former finding to be a robust one, but was unable to reveal any support for the latter. Experiment 1 also revealed that expert superiority is more apparent for predictions made under natural (coupled) than uncoupled response-mode conditions. Collectively, these findings suggest that different perceptual processes may be in operation in anticipatory tasks which depend on skill level, the type of information presented, and degree of perception-action coupling inherent in the task requirements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined effects of body size and temperature on swimming performance in juvenile estuarine crocodiles, Crocodylus porosus, over the size range of 30-110 cm total body length. Swimming performance, expressed as maximum sustainable swimming speed, was measured in a temperature- and flow-controlled swimming flume. Absolute sustainable swimming speed increased with body length, but length-specific swimming performance decreased as body length increased. Sustained swimming speed increased with temperature between 15degreesC and 23degreesC, remained constant between 23degrees and 33degreesC, and decreased as temperature rose above 33degreesC. Q(10)-values of swimming speed were 2.60 (+/- 0.091 SE) between 18degreesC and 23degreesC, and there were no differences in Q(10) between crocodiles of different sizes. The broad plateau of thermal independence in swimming speed observed in C. porosus may be of adaptive significance by allowing dispersal of juvenile animals at suboptimal body temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concurrent programs are hard to test due to the inherent nondeterminism. This paper presents a method and tool support for testing concurrent Java components. Too[ support is offered through ConAn (Concurrency Analyser), a too] for generating drivers for unit testing Java classes that are used in a multithreaded context. To obtain adequate controllability over the interactions between Java threads, the generated driver contains threads that are synchronized by a clock. The driver automatically executes the calls in the test sequence in the prescribed order and compares the outputs against the expected outputs specified in the test sequence. The method and tool are illustrated in detail on an asymmetric producer-consumer monitor. Their application to testing over 20 concurrent components, a number of which are sourced from industry and were found to contain faults, is presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased professionalism in rugby has elicited rapid changes in the fitness profile of elite players. Recent research, focusing on the physiological and anthropometrical characteristics of rugby players, and the demands of competition are reviewed. The paucity of research on contemporary elite rugby players is highlighted, along with the need for standardised testing protocols. Recent data reinforce the pronounced differences in the anthropometric and physical characteristics of the forwards and backs. Forwards are typically heavier, taller, and have a greater proportion of body fat than backs. These characteristics are changing, with forwards developing greater total mass and higher muscularity. The forwards demonstrate superior absolute aerobic and anaerobic power, and Muscular strength. Results favour the backs when body mass is taken into account. The scaling of results to body mass can be problematic and future investigations should present results using power function ratios. Recommended tests for elite players include body mass and skinfolds, vertical jump, speed, and the multi-stage shuttle run. Repeat sprint testing is a possible avenue for more specific evaluation of players. During competition, high-intensity efforts are often followed by periods of incomplete recovery. The total work over the duration of a game is lower in the backs compared with the forwards; forwards spend greater time in physical contact with the opposition while the backs spend more time in free running, allowing them to cover greater distances. The intense efforts undertaken by rugby players place considerable stress on anaerobic energy sources, while the aerobic system provides energy during repeated efforts and for recovery. Training should focus on repeated brief high-intensity efforts with short rest intervals to condition players to the demands of the game. Training for the forwards should emphasise the higher work rates of the game, while extended rest periods can be provided to the backs. Players should not only be prepared for the demands of competition, but also the stress of travel and extreme environmental conditions. The greater professionalism of rugby union has increased scientific research in the sport; however, there is scope for significant refinement of investigations on the physiological demands of the game, and sports-specific testing procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the cycling performance of cyclists and triathletes. Each week for 3 weeks, and on different days, 25 highly trained male cyclists and 18 highly trained male triathletes performed: (1) an incremental exercise test on a cycle ergometer for the determination of peak oxygen consumption ((V) over dot O-2peak), peak power output and the first and second ventilatory thresholds, followed 15 min later by a sprint to volitional fatigue at 150% of peak power output; (2) a cycle to exhaustion test at the (V) over dot O-2peak power output; and (3) a 40-km cycle time-trial. There were no differences in (V) over dot O-2peak, peak power output, time to volitional fatigue at 150% of peak power output or time to exhaustion at (V) over dot O-2peak power output between the two groups. However, the cyclists had a significantly faster time to complete the 40-km time-trial (56:18 +/- 2:31 min:s; mean +/- s) than the triathletes (58:57 +/- 3:06 min:s; P < 0.01), which could be partially explained (r = 0.34-0.51; P < 0.05) by a significantly higher first (3.32 +/- 0.36 vs 3.08 +/- 0.36 l . min(-1)) and second ventilatory threshold (4.05 +/- 0.36 vs 3.81 +/- 0.29 l . min(-1); both P < 0.05) in the cyclists compared with the triathletes. In conclusion, cyclists may be able to perform better than triathletes in cycling time-trial events because they have higher first and second ventilatory thresholds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of the present study was to investigate the between-days reliability of electromyographic (EMG) measurement of 6 bilateral trunk muscles and also the torque output in 3 planes during isometric right and left axial rotation at different exertion levels. Methods: Ten healthy subjects performed isometric right and left axial rotation at 100, 70, 50 and 30% maximum voluntary contractions in two testing sessions at least 7 days apart. EMG amplitude and frequency analyses of the recorded surface EMG signals were performed for rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum and multifidus bilaterally. The primary torque in the transverse plane and the coupling torques in sagittal and coronal planes were measured. Results: For both EMG amplitude and frequency values, good (intraclass correlation coefficient, ICC = 0.75-0.89) to excellent (ICC greater than or equal to 0.90) reliability was found in the 6 trunk muscles at different exertion levels during axial rotation. The reliability of both maximal isometric axial rotation torque and coupling torques in sagittal and coronal planes were found to be excellent (ICC greater than or equal to 0.93). Conclusions: Good to excellent reliability of EMG measures of trunk muscles and torque measurements during isometric axial rotation was demonstrated. This provides further confidence of using EMG and triaxial torque assessment as outcome measures in rehabilitation and in the evaluation of the human performance in the work place. (C) 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Helicobacter pylori infection is common among adults with intellectual disability. The acceptabilities and accuracies of different diagnostic tests in this population are unknown. We aimed to determine (i) patient acceptability and (ii) performance characteristics of serology, fecal-antigen, and urea breath tests among adults with intellectual disability. One hundred sixty-eight such adults underwent H. pylori testing with serology and fecal-antigen tests, and a portion underwent treatment. One year later, the participants were retested with fecal-antigen, serology, and urea breath tests. The numbers of specimens obtained and difficulties in collection reported by caregivers were noted. Test performance characteristics were assessed among participants and 65 of their caregivers, using serology as the reference. All participants provided at least one specimen, despite reported collection difficulties for 23% of fecal and 27% of blood specimens. Only 25% of the participants provided breath specimens; failure to perform this test was associated with lower intellectual ability and higher maladaptive behavior. The sensitivity, specificity, and positive and negative predictive values of the fecal test (baseline and 12 months versus caregivers) were 70 and 63 versus 81, 93 and 95 versus 98, 96 and 92 versus 93, and 53 and 74 versus 93%, respectively; those of the urea breath test (12 months versus caregivers) were 86 versus 100, 88 versus 95, 75 versus 89, and 94 versus 100%, respectively. With assistance, fecal or blood specimens for H. pylori assessment can be provided by most patients with intellectual disability regardless of their level of function or behavior. Only those with greater ability can perform the urea breath test. Using serology as the reference test, the limitations of performance characteristics of the fecal-antigen and urea breath tests are similar to those among a control group of caregivers.