977 resultados para performance matrix
Resumo:
A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.
Resumo:
IEEE International Conference on Communications (IEEE ICC 2015). 8 to 12, Jun, 2015, IEEE ICC 2015 - Communications QoS, Reliability and Modeling, London, United Kingdom.
Resumo:
6th Graduate Student Symposium on Molecular Imprinting
Resumo:
This work presents the development of a low cost sensor device for the diagnosis of breast cancer in point-of-care, made with new synthetic biomimetic materials inside plasticized poly(vinyl chloride), PVC, membranes, for subsequent potentiometric detection. This concept was applied to target a conventional biomarker in breast cancer: Breast Cancer Antigen (CA15-3). The new biomimetic material was obtained by molecularly-imprinted technology. In this, a plastic antibody was obtained by polymerizing around the biomarker that acted as an obstacle to the growth of the polymeric matrix. The imprinted polymer was specifically synthetized by electropolymerization on an FTO conductive glass, by using cyclic voltammetry, including 40 cycles within -0.2 and 1.0 V. The reaction used for the polymerization included monomer (pyrrol, 5.0×10-3 mol/L) and protein (CA15-3, 100U/mL), all prepared in phosphate buffer saline (PBS), with a pH of 7.2 and 1% of ethylene glycol. The biomarker was removed from the imprinted sites by proteolytic action of proteinase K. The biomimetic material was employed in the construction of potentiometric sensors and tested with regard to its affinity and selectivity for binding CA15-3, by checking the analytical performance of the obtained electrodes. For this purpose, the biomimetic material was dispersed in plasticized PVC membranes, including or not a lipophilic ionic additive, and applied on a solid conductive support of graphite. The analytical behaviour was evaluated in buffer and in synthetic serum, with regard to linear range, limit of detection, repeatability, and reproducibility. This antibody-like material was tested in synthetic serum, and good results were obtained. The best devices were able to detect 5 times less CA15-3 than that required in clinical use. Selectivity assays were also performed, showing that the various serum components did not interfere with this biomarker. Overall, the potentiometric-based methods showed several advantages compared to other methods reported in the literature. The analytical process was simple, providing fast responses for a reduced amount of analyte, with low cost and feasible miniaturization. It also allowed the detection of a wide range of concentrations, diminishing the required efforts in previous sample pre-treating stages.
Resumo:
III Jornadas de Electroquímica e Inovação (Electroquímica e Nanomateriais), na Universidade de Trás-os-Montes e Alto Douro, Vila Real, 16 a 17 de Setembro de 2013
Resumo:
Graduate Student Symposium on Molecular Imprinting 2013, na Queen’s University, Belfast, United Kingdom, 15 a 17 de Agosto de 2013
Resumo:
Although the Giemsa-stained thick blood smear (GTS) remains the gold standard for the diagnosis of malaria, molecular methods are more sensitive and specific to detect parasites and can be used at reference centers to evaluate the performance of microscopy. The description of the Plasmodium falciparum, P. vivax, P. malariae and P. ovale ssrRNA gene sequences allowed the development of a polymerase chain reaction (PCR) that had been used to differentiate the four species. The objective of this study was to determine Plasmodium species through PCR in 190 positive smears from patients in order to verify the quality of diagnosis at SUCEN's Malaria Laboratory. Considering only the 131 positive results in both techniques, GTS detected 4.6% of mixed and 3.1% of P. malariae infections whereas PCR identified 19.1% and 13.8%, respectively.
Resumo:
RTUWO Advances in Wireless and Optical Communications 2015 (RTUWO 2015). 5-6 Nov Riga, Latvia.
Resumo:
This study aims to analyze and compare four micro-firms' organizational culture, evaluated through the Competing Values Framework (Quinn & Rohbaugh, 1983). Data was collected in 2011 and 2013 in firms selling the same type of software and providing the same kind of services, focusing on the years between 2008-2011. Findings point to somewhat different results of micro-firms, when comparing to other samples in the literature. Suggestions for future research are given.
Resumo:
Dissertação para Obtenção de Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
This study aims at investigating the influence that entrepreneurial orientation has on export performance of Portuguese footwear small and mediumenterprises (SMEs). Therefore, a quantitative methodological approach was used, conducting a descriptive, exploratory and transversal empirical study, having applied a questionnaire to a sample of Portuguese companies exporting footwear. The research results suggest that entrepreneurial orientation enhances export performance in the analysed SMEs, particularly innovation and proactiveness, through the amount of funds invested, human resources dedicated to this activity, number of new products or services introduced in the market and frequent change in product lines or services and materialization of a long-term perspective, which is accompanied by innovative activities or new businesses. Therefore, the findings sustain the necessity to invest in entrepreneurial orientation as a strategic determinant, which contributes to the growth of small firms in foreignmarkets. Finally, the main limitation of this study is related to the sample size, since it was difficult to find companies willing to collaborate with this kind of research.
Resumo:
Redundant manipulators have some advantages when compared with classical arms because they allow the trajectory optimization, both on the free space and on the presence of abstacles, and the resolution of singularities. For this type of manipulators, several kinetic algorithms adopt generalized inverse matrices. In this line of thought, the generalized inverse control scheme is tested through several experiments that reveal the difficulties that often arise. Motivated by theseproblems this paper presents a new method that ptimizes the manipulability through a least squre polynomialapproximation to determine the joints positions. Moreover, the article studies influence on the dynamics, when controlling redundant and hyper-redundant manipulators. The experiment confirm the superior performance of the proposed algorithm for redundant and hyper-redundant manipulators, revealing several fundamental properties of the chaotic phenomena, and gives a deeper insight towards the future development of superior trajectory control algorithms.
Resumo:
This paper presents the dynamic analysis of robotic biped systems. The main goal is to gain insight into the phenomena of walking and to evaluate its performance. In this study, we propose three methods to quantitatively measure the dynamic efficiency of walking: energy analysis, perturbation analysis and lowpass frequency analysis. In order to accomplish this goal, the prescribed motion of the biped is completely characterised in terms of a set of locomotion variables, namely: step lenght, hip height, hip ripple, hip offset, foot clearance and link lenghts. based on these variables and their influence, the performance measures aer discussed and the results compared with those observed in nature.
Resumo:
Assessment of surgical performance is a must for every surgical practice nowadays and can be done by using scientific methods imported mostly from the Quality control tools that have been in use for long in industry. Surgical performance comprises several dimensions including clinical activity (mortality and morbidity as end points), academic activities, research and, more and more, efficiency. Stable long time results (efficacy), reducing error (safety) and meeting patient expectations (patient satisfaction) are among other performance components. This paper focus on the precise definitions of mortality and morbidity related to surgical activities and on the tools to evaluate patient complexity and assess pre operative risk. Some graphic representations are suggested to compare performance profiles of surgeons and to define individual performance profiles. Strong emphasis is put on pre operative risk assessment and its crucial role to interpret divergent surgical results. Where risk assessment is not possible or is unavailable, observed / expected ratios (O/E) for a given endpoint , be it mortality, length of stay or morbidity, must be established and routinely used to refer results and to identify performance outliers. Morbidity is being pointed out as a most valuable performance indicator in surgery because it is sensitive and comprises efficiency, safety and quality, at large.