998 resultados para panospheric image plane
Resumo:
Back-focal-plane interferometry is used to measure displacements of optically trapped samples with very high spatial and temporal resolution. However, the technique is closely related to a method that measures the rate of change in light momentum. It has long been known that displacements of the interference pattern at the back focal plane may be used to track the optical force directly, provided that a considerable fraction of the light is effectively monitored. Nonetheless, the practical application of this idea has been limited to counter-propagating, low-aperture beams where the accurate momentum measurements are possible. Here, we experimentally show that the connection can be extended to single-beam optical traps. In particular, we show that, in a gradient trap, the calibration product κ·β (where κ is the trap stiffness and 1/β is the position sensitivity) corresponds to the factor that converts detector signals into momentum changes; this factor is uniquely determined by three construction features of the detection instrument and does not depend, therefore, on the specific conditions of the experiment. Then, we find that force measurements obtained from back-focal-plane displacements are in practice not restricted to a linear relationship with position and hence they can be extended outside that regime. Finally, and more importantly, we show that these properties are still recognizable even when the system is not fully optimized for light collection. These results should enable a more general use of back-focal-plane interferometry whenever the ultimate goal is the measurement of the forces exerted by an optical trap.
Resumo:
Back-focal-plane interferometry is used to measure displacements of optically trapped samples with very high spatial and temporal resolution. However, the technique is closely related to a method that measures the rate of change in light momentum. It has long been known that displacements of the interference pattern at the back focal plane may be used to track the optical force directly, provided that a considerable fraction of the light is effectively monitored. Nonetheless, the practical application of this idea has been limited to counter-propagating, low-aperture beams where the accurate momentum measurements are possible. Here, we experimentally show that the connection can be extended to single-beam optical traps. In particular, we show that, in a gradient trap, the calibration product κ·β (where κ is the trap stiffness and 1/β is the position sensitivity) corresponds to the factor that converts detector signals into momentum changes; this factor is uniquely determined by three construction features of the detection instrument and does not depend, therefore, on the specific conditions of the experiment. Then, we find that force measurements obtained from back-focal-plane displacements are in practice not restricted to a linear relationship with position and hence they can be extended outside that regime. Finally, and more importantly, we show that these properties are still recognizable even when the system is not fully optimized for light collection. These results should enable a more general use of back-focal-plane interferometry whenever the ultimate goal is the measurement of the forces exerted by an optical trap.
Resumo:
The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.
Resumo:
A major problem with holographic optical tweezers (HOTs) is their incompatibility with laser-based position detection methods, such as back-focal-plane interferometry (BFPI). The alternatives generally used with HOTs, like high-speed video tracking, do not offer the same spatial and temporal bandwidths. This has limited the use of this technique in precise quantitative experiments. In this paper, we present an optical trap design that combines digital holography and back-focal-plane displacement detection. We show that, with a particularly simple setup, it is possible to generate a set of multiple holographic traps and an additional static non-holographic trap with orthogonal polarizations and that they can be, therefore, easily separated for measuring positions and forces with the high positional and temporal resolutions of laser-based detection. We prove that measurements from both polarizations contain less than 1% crosstalk and that traps in our setup are harmonic within the typical range. We further tested the instrument in a DNA stretching experiment and we discuss an interesting property of this configuration: the small drift of the differential signal between traps.
Resumo:
L'article aborde la façon dont la série BD Le Linceul (2003-2006) s'approprie, dans le cadre de la fiction et du récit d'action grand public, le contexte de la réception de l'image acheiropoïète du Saint Suaire, intégrant la référence à des enjeux théologiques et scientifiques au sein d'une histoire à suspense située à différentes époques et dont les nombreux rebondissements s'articulent autour d'une croyance progressive dans le statut sacré de la vera icon. L'examen détaillé de certains choix narratifs et graphiques de l'auteur Laurent Bidot permet de dégager les modalités d'une exploitation contemporaine et (a priori) laïcisée de la figure de Jésus qui, à l'ère des technologies numériques, conserve sa part de mystère. Dans une perspective narratologique, l'interprétation procède principalement de constats liés à l'organisation énonciative de cette production bédéique.
Resumo:
The major objective of this project is to evaluate image analysis for characterizing air voids in Portland cement contract (PCC) and asphalt concrete (AC) and aggregate gradation in asphalt concrete. Phase 1 of this project has concentrated on evaluation and refinement of sample preparation techniques, evaluation of methods and instruments for conducting image analysis, and finally, analysis and comparison of a select portion of samples. Preliminary results suggest a strong correlation between the results obtained from the linear traverse method and image analysis methods for determining percent air voids in concrete. Preliminary work with asphalt samples has shown that damage caused by a high vacuum of the conventional scanning electron microscope (SEM) may too disruptive. Alternative solutions have been explored, including confocal microscopy and low vacuum electron microscopy. Additionally, a conventional high vacuum SEM operating at a marginal operating vacuum may suffice.
Resumo:
The major features in eating disorders are a preoccupation with food and its consumption and body dissatisfaction. Diagnostic manuals provide clusters of criteria according to which affected individuals can be categorized into one or other group of eating disorder. Yet, when considering the high proportion of comorbidities and ignoring the content of the symptoms (food, body), the major features seem to yield obsessional-compulsive, addictive, and impulsive qualities. In the present article, we review studies from the neuroscientific literature (mainly lesion studies) on eating disorder, obsessive-compulsive disorder, impulse control disorder, and addiction to investigate the possibility of a wider phenotype that can be related to a common brain network. The literature localizes this network to the right frontal lobe and its connectivities. This network, when dysfunctional, might result in a behavior that favors the preoccupation with particular thoughts, behaviors, anxieties, and uncontrollable urges that are accompanied by little scope for ongoing behavioral adjustments (e.g., impulse control). We reason that this network may turn out to be equally involved in understudied mental conditions of dysfunctional body processing such as muscle dysmorphia, body dysmorphic disorder (including esthetic surgery), and xelomelia. We finally consider previous notions of a wider phenotype approach to current diagnostic practice (using DSM), such as the possibility of a model with a reduced number of diagnostic categories and primary and secondary factors, and to etiological models of mental health conditions.
Resumo:
Inference of Markov random field images segmentation models is usually performed using iterative methods which adapt the well-known expectation-maximization (EM) algorithm for independent mixture models. However, some of these adaptations are ad hoc and may turn out numerically unstable. In this paper, we review three EM-like variants for Markov random field segmentation and compare their convergence properties both at the theoretical and practical levels. We specifically advocate a numerical scheme involving asynchronous voxel updating, for which general convergence results can be established. Our experiments on brain tissue classification in magnetic resonance images provide evidence that this algorithm may achieve significantly faster convergence than its competitors while yielding at least as good segmentation results.
Resumo:
PURPOSE: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. METHODS: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectors and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). RESULTS: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290μSv for an adult and 200 μSv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. CONCLUSIONS: As a summary, the estimated effective dose was 290μSv for an adult; the image quality remains comparable to conventional systems.
Resumo:
PURPOSE: To implement real-time myocardial strain-encoding (SENC) imaging in combination with tracking the tissue displacement in the through-plane direction. MATERIALS AND METHODS: SENC imaging was combined with the slice-following technique by implementing three-dimensional (3D) selective excitation. Certain adjustments were implemented to reduce scan time to one heartbeat. A total of 10 volunteers and five pigs were scanned on a 3T MRI scanner. Spatial modulation of magnetization (SPAMM)-tagged images were acquired on planes orthogonal to the SENC planes for comparison. Myocardial infarction (MI) was induced in two pigs and the resulting SENC images were compared to standard delayed-enhancement (DE) images. RESULTS: The strain values computed from SENC imaging with slice-following showed significant difference from those acquired without slice-following, especially during systole (P < 0.01). The strain curves computed from the SENC images with and without slice-following were similar to those computed from the orthogonal SPAMM images, with and without, respectively, tracking the tag line displacement in the strain direction. The resulting SENC images showed good agreement with the DE images in identifying MI in infarcted pigs. CONCLUSION: Correction of through-plane motion in real-time cardiac functional imaging is feasible using slice-following. The strain measurements are more accurate than conventional SENC measurements in humans and animals, as validated with conventional MRI tagging.
Resumo:
Extended abstract.
Resumo:
This article reports on a lossless data hiding scheme for digital images where the data hiding capacity is either determined by minimum acceptable subjective quality or by the demanded capacity. In the proposed method data is hidden within the image prediction errors, where the most well-known prediction algorithms such as the median edge detector (MED), gradient adjacent prediction (GAP) and Jiang prediction are tested for this purpose. In this method, first the histogram of the prediction errors of images are computed and then based on the required capacity or desired image quality, the prediction error values of frequencies larger than this capacity are shifted. The empty space created by such a shift is used for embedding the data. Experimental results show distinct superiority of the image prediction error histogram over the conventional image histogram itself, due to much narrower spectrum of the former over the latter. We have also devised an adaptive method for hiding data, where subjective quality is traded for data hiding capacity. Here the positive and negative error values are chosen such that the sum of their frequencies on the histogram is just above the given capacity or above a certain quality.
Resumo:
This letter presents a lossless data hiding scheme for digital images which uses an edge detector to locate plain areas for embedding. The proposed method takes advantage of the well-known gradient adjacent prediction utilized in image coding. In the suggested scheme, prediction errors and edge values are first computed and then, excluding the edge pixels, prediction error values are slightly modified through shifting the prediction errors to embed data. The aim of proposed scheme is to decrease the amount of modified pixels to improve transparency by keeping edge pixel values of the image. The experimental results have demonstrated that the proposed method is capable of hiding more secret data than the known techniques at the same PSNR, thus proving that using edge detector to locate plain areas for lossless data embedding can enhance the performance in terms of data embedding rate versus the PSNR of marked images with respect to original image.
Resumo:
Peer-reviewed
Resumo:
Background: We examined one's own body image perception and its association with reported weight-related behavior among adolescents of a rapidly developing country in the African region. Methods: We conducted a school-based survey of 1432 students aged 11-17 years in the Seychelles. Weight and height were measured, and thinness, normal weight and overweight were assessed along standard criteria. A self-administered and anonymous questionnaire was administered. Perception of body image was assessed using both a closed-ended question (CEQ) and the Stunkard's pictorial silhouettes (SPS). Finally, a question assessed voluntary attempts to change weight. Results: Overall, 14.1% of the students were thin, 63.9% were normal-weight, and 22.0% were overweight or obese. There was fair agreement between actual weight status and self-perceived body image based on either CEQ or SPS. However, a substantial proportion of the overweight students did not consider themselves as overweight (SPS: 24%, CEQ: 34%) and, inversely, a substantial proportion of the normal-weight students considered themselves as too thin (SPS: 29%, CEQ: 15%). Among the overweight students, an adequate attempt to lose weight was reported more often by boys and girls who perceived themselves as overweight vs. not overweight (72-88% vs. 40-71%, p <0.05 for most comparisons). Among the normal-weight students, an inadequate attempt to gain weight was reported more often by boys and girls who perceived themselves as thin vs. not thin (27-68% vs. 11-19%, p <0.05). Girls had leaner own body ideals than boys. Conclusions: We found that substantial proportions of overweight students did not perceive themselves as overweight and/or did not want to lose weight and, inversely, that many normalweight students perceived themselves as too thin and/or wanted to gain weight: this points to forces that can drive the upwards overweight trends. Appropriate perception of one's weight was associated with adequate weight-control behavior, although not strongly, emphasizing that appropriate weight perception is only one of several factors driving adequate weight-related behavior. These findings emphasize the need to address appropriate perception of one's own weight and adequate weight-related behavior in adolescents for both individual and community weight-related interventions.