1000 resultados para microvascular network
Resumo:
The integrated absorption cross section Sigma(abs), I peak emission cross section sigma(cmi), Judd-Ofeld intensity parameters Omega(iota) ( t = 2,4,6), and spontaneous emission probability A(R) of Er3+ ions were determined for Erbium doped alkali and alkaline earth phosphate glasses. It is found the compositional dependence of sigma(emi) 5 almost similar to that of Sigma(abs), which is determined by the sum, of Omega(1) (3 Omega(2) + 10 Omega(4) + 21 Omega(6)). In addition, the compositional dependence of Omega(1) was studied in these glass systems. As a result, compared with. Omega(4) and Omega(6) the Omega(2) has a stronger compositional dependence on the ionic radius and content of modifers. The covalency of Er-O bonds in phosphate glass is weaker than that in silicate glass, germanate glass, aluminate glass, and tellurate glass, since Omega(6) of phosphate glass is relatively large. A(R) is affected by the covalency of the Er3+ ion sites and corresponds to the Omega(6) value.
Resumo:
FSodium phosphate tellurite glasses in the system (NaPO3)(x)(TeO2)(1-x) were prepared and structurally characterized by thermal analysis, vibrational spectroscopy, X-ray photoelectron spectroscopy (XPS) and a variety of complementary solid-state nuclear magnetic resonance (NMR) techniques. Unlike the situation in other mixed-network-former glasses, the interaction between the two network formers tellurium oxide and phosphorus oxide produces no new structural units, and no sharing of the network modifier Na2O takes place. The glass structure can be regarded as a network of interlinked metaphosphate-type P(2) tetrahedral and TeO4/2 antiprismotic units. The combined interpretation of the O 1s XPS data and the P-31 solid-state NMR spectra presents clear quantitative evidence for a nonstatistical connectivity distribution. Rather the formation of homootomic P-O-P and Te-O-Te linkages is favored over mixed P-O-Te connectivities. As a consequence of this chemical segregation effect, the spatial sodium distribution is not random, as also indicated by a detailed analysis of P-31/No-23 rotational echo double-resonance (REDOR) experiments. ACHTUNGTRENUNG(TeO2)1 x were prepared and structurally characterized by thermal analysis,vibrat ional spectroscopy,X-ray photoelectron spectroscopy (XPS) and a variety of complementary solid-state nuclear magnetic resonance (NMR) techniques. Unlike the situation in other mixed-network-former glasses,the interaction between the two network formers tellurium oxide and phosphorus oxide produces no new structural units,and no sharing of the network modifier Na2O takes place. The glass structure can be regarded as a network of interlinked metaphosphate-type P(2) tetrahedral and TeO4/2 antiprismatic units. The combined interpretation of the O 1s XPS data and the 31P solid-state NMR spectra presents clear quantitative evidence for a nonstatistical connectivity distribution. Rather,the formation of homoatomic P O P and Te O Te linkages is favored over mixed P O Te connectivities. As a consequence of this chemical segregation effect,the spatial sodium distribution is not random,as also indicated by a detailed analysis of 31P/23Na rotational echo double-resonance (REDOR) experiments.
Resumo:
Smart Grids are becoming a reality all over the world. Nowadays, the research efforts for the introduction and deployment of these grids are mainly focused on the development of the field of Smart Metering. This emerging application requires the use of technologies to access the significant number of points of supply (PoS) existing in the grid, covering the Low Voltage (LV) segment with the lowest possible costs. Power Line Communications (PLC) have been extensively used in electricity grids for a variety of purposes and, of late, have been the focus of renewed interest. PLC are really well suited for quick and inexpensive pervasive deployments. However, no LV grid is the same in any electricity company (utility), and the particularities of each grid evolution, architecture, circumstances and materials, makes it a challenge to deploy Smart Metering networks with PLC technologies, with the Smart Grid as an ultimate goal. This paper covers the evolution of Smart Metering networks, together with the evolution of PLC technologies until both worlds have converged to project PLC-enabled Smart Metering networks towards Smart Grid. This paper develops guidelines over a set of strategic aspects of PLC Smart Metering network deployment based on the knowledge gathered on real field; and introduces the future challenges of these networks in their evolution towards the Smart Grid.
Resumo:
As mudanças nos hábitos alimentares têm causado efeitos impressionantes na saúde pública, diretamente relacionados ao aumento da ingestão de refeições ricas em gorduras, principalmente gorduras saturadas. A principal consequência desse consumo é o estado prolongado e excessivo da lipemia pós-prandial (LPP), considerada um dos fatores relacionados às anormalidades metabólicas e aos danos vasculares. O objetivo do estudo foiavaliar o efeito da sobrecarga lipídica na reatividade microvascular em mulheres obesas. Das 41 participantes deste estudo, 21 apresentavam o diagnóstico de obesidade, com IMC de 32,41,6 kg/m2 (média SD) e idade 31,65 anos e 20 mulheres saudáveis, com IMC de 21,91,7 kg/m2 e idade 27,25,5 anos. Após a avaliação clínica e laboratorial, as participantes tiveram a microcirculação examinada por dois métodos: a dinâmica do leito periungueal, para avaliação da densidade capilar funcional (DCF), velocidade de deslocamento das hemácias no basal (VDH) e após uma isquemia de 1 min (VDHmax) e tempo de reperfusão (TVDHmax). A segunda técnica foi a do dorso do dedo para avaliação da DCF no repouso, durante a hiperemia reativa e após oclusão venosa. Foi feita a coleta de sangue para avaliação do colesterol total (CT), triglicerídeos (TG), HDL-c e ácidos graxos livres (AGL), glicose, insulina e viscosidade plasmática em 30 e 50 rotações por minuto (rpm). Também foram medidas a pressão arterial sistólica (PAS), diastólica (PAD) e frequência cardíaca (FC). Após essas análises no repouso, todas as participantes receberam uma refeição rica em lipídios, e após 30, 60, 120 e 180 minutos da ingestão da refeição, os exames de videocapilaroscopia e a coleta de sangue foram novamente realizados.As participantes com obesidade apresentaram, após a sobrecarga lipídica, valores significativamente menores do que no jejum para: DCF basal do dorso do dedo (p=0,02); DCF durante hiperemia reativa (p=0,02), DCF pós-oclusão venosa (p=0,02), HDL-c (p<0,0001), LDL-C (p<0,0001) e AGL (p<0,0001) e valores elevados para: VDH (p<0,0001), VDHmax(p=0,003), TVDHmax (p=0,004), glicose (p<0,0001), insulina (p<0,001), CT (p=0,03), TG (p<0,0001) e FC (p=0,03). Alterações na viscosidade não foram observadas no grupo OB após a refeição quando comparado aos seus valores basais em 30 e 50 rpm (p=0,87 e p=0,42, respectivamente). A PAS foi elevada nas participantes OB após a sobrecarga quando comparada às saudáveis em todo tempo de estudo. Concluímos que alimentos ricos em lipídios podem aumentar ainda mais a disfunção microcirculatória e as alterações metabólicas já presentes em mulheres obesas.
Resumo:
Artículo científico Inorg. Chem. 2013, 52, 8074−8081
Resumo:
Abstract de congreso: Póster presentado en 12th International Conference on Materials Chemistry (MC12), 20 - 23 July 2015, York, United Kingdom
Resumo:
Poster presentado en el congreso: Third International Conference on Multifunctional, Hybrid and Nanomaterials (3-7 March 2013, Sorrento, Italy)