993 resultados para mechanical separation
Resumo:
A comprehensive study was made of the flocculation of dispersed E. coli bacterial cells by the cationic polymer polyethyleneimine (PEI). The three objectives of this study were to determine the primary mechanism involved in the flocculation of a colloid with an oppositely charged polymer, to determine quantitative correlations between four commonly-used measurements of the extent of flocculation, and to record the effect of varying selected system parameters on the degree of flocculation. The quantitative relationships derived for the four measurements of the extent of flocculation should be of direct assistance to the sanitary engineer in evaluating the effectiveness of specific coagulation processes.
A review of prior statistical mechanical treatments of absorbed polymer configuration revealed that at low degrees of surface site coverage, an oppositely- charged polymer molecule is strongly adsorbed to the colloidal surface, with only short loops or end sequences extending into the solution phase. Even for high molecular weight PEI species, these extensions from the surface are theorized to be less than 50 Å in length. Although the radii of gyration of the five PEI species investigated were found to be large enough to form interparticle bridges, the low surface site coverage at optimum flocculation doses indicates that the predominant mechanism of flocculation is adsorption coagulation.
The effectiveness of the high-molecular weight PEI species 1n producing rapid flocculation at small doses is attributed to the formation of a charge mosaic on the oppositely-charged E. coli surfaces. The large adsorbed PEI molecules not only neutralize the surface charge at the adsorption sites, but also cause charge reversal with excess cationic segments. The alignment of these positive surface patches with negative patches on approaching cells results in strong electrostatic attraction in addition to a reduction of the double-layer interaction energies. The comparative ineffectiveness of low-molecular weight PEI species in producing E. coli flocculation is caused by the size of the individual molecules, which is insufficient to both neutralize and reverse the negative E.coli surface charge. Consequently, coagulation produced by low molecular weight species is attributed solely to the reduction of double-layer interaction energies via adsorption.
Electrophoretic mobility experiments supported the above conclusions, since only the high-molecular weight species were able to reverse the mobility of the E. coli cells. In addition, electron microscope examination of the seam of agglutination between E. coli cells flocculation by PEI revealed tightly- bound cells, with intercellular separation distances of less than 100-200 Å in most instances. This intercellular separation is partially due to cell shrinkage in preparation of the electron micrographs.
The extent of flocculation was measured as a function of PEl molecular weight, PEl dose, and the intensity of reactor chamber mixing. Neither the intensity of mixing, within the common treatment practice limits, nor the time of mixing for up to four hours appeared to play any significant role in either the size or number of E.coli aggregates formed. The extent of flocculation was highly molecular weight dependent: the high-molecular-weight PEl species produce the larger aggregates, the greater turbidity reductions, and the higher filtration flow rates. The PEl dose required for optimum flocculation decreased as the species molecular weight increased. At large doses of high-molecular-weight species, redispersion of the macroflocs occurred, caused by excess adsorption of cationic molecules. The excess adsorption reversed the surface charge on the E.coli cells, as recorded by electrophoretic mobility measurements.
Successful quantitative comparisons were made between changes in suspension turbidity with flocculation and corresponding changes in aggregate size distribution. E. coli aggregates were treated as coalesced spheres, with Mie scattering coefficients determined for spheres in the anomalous diffraction regime. Good quantitative comparisons were also found to exist between the reduction in refiltration time and the reduction of the total colloid surface area caused by flocculation. As with turbidity measurements, a coalesced sphere model was used since the equivalent spherical volume is the only information available from the Coulter particle counter. However, the coalesced sphere model was not applicable to electrophoretic mobility measurements. The aggregates produced at each PEl dose moved at approximately the same vlocity, almost independently of particle size.
PEl was found to be an effective flocculant of E. coli cells at weight ratios of 1 mg PEl: 100 mg E. coli. While PEl itself is toxic to E.coli at these levels, similar cationic polymers could be effectively applied to water and wastewater treatment facilities to enhance sedimentation and filtration characteristics.
Resumo:
Compliant foams are usually characterized by a wide range of desirable mechanical properties. These properties include viscoelasticity at different temperatures, energy absorption, recoverability under cyclic loading, impact resistance, and thermal, electrical, acoustic and radiation-resistance. Some foams contain nano-sized features and are used in small-scale devices. This implies that the characteristic dimensions of foams span multiple length scales, rendering modeling their mechanical properties difficult. Continuum mechanics-based models capture some salient experimental features like the linear elastic regime, followed by non-linear plateau stress regime. However, they lack mesostructural physical details. This makes them incapable of accurately predicting local peaks in stress and strain distributions, which significantly affect the deformation paths. Atomistic methods are capable of capturing the physical origins of deformation at smaller scales, but suffer from impractical computational intensity. Capturing deformation at the so-called meso-scale, which is capable of describing the phenomenon at a continuum level, but with some physical insights, requires developing new theoretical approaches.
A fundamental question that motivates the modeling of foams is ‘how to extract the intrinsic material response from simple mechanical test data, such as stress vs. strain response?’ A 3D model was developed to simulate the mechanical response of foam-type materials. The novelty of this model includes unique features such as the hardening-softening-hardening material response, strain rate-dependence, and plastically compressible solids with plastic non-normality. Suggestive links from atomistic simulations of foams were borrowed to formulate a physically informed hardening material input function. Motivated by a model that qualitatively captured the response of foam-type vertically aligned carbon nanotube (VACNT) pillars under uniaxial compression [2011,“Analysis of Uniaxial Compression of Vertically Aligned Carbon Nanotubes,” J. Mech.Phys. Solids, 59, pp. 2227–2237, Erratum 60, 1753–1756 (2012)], the property space exploration was advanced to three types of simple mechanical tests: 1) uniaxial compression, 2) uniaxial tension, and 3) nanoindentation with a conical and a flat-punch tip. The simulations attempt to explain some of the salient features in experimental data, like
1) The initial linear elastic response.
2) One or more nonlinear instabilities, yielding, and hardening.
The model-inherent relationships between the material properties and the overall stress-strain behavior were validated against the available experimental data. The material properties include the gradient in stiffness along the height, plastic and elastic compressibility, and hardening. Each of these tests was evaluated in terms of their efficiency in extracting material properties. The uniaxial simulation results proved to be a combination of structural and material influences. Out of all deformation paths, flat-punch indentation proved to be superior since it is the most sensitive in capturing the material properties.
Resumo:
Advances in nano-scale mechanical testing have brought about progress in the understanding of physical phenomena in materials and a measure of control in the fabrication of novel materials. In contrast to bulk materials that display size-invariant mechanical properties, sub-micron metallic samples show a critical dependence on sample size. The strength of nano-scale single crystalline metals is well-described by a power-law function, σαD-n, where D is a critical sample size and n is a experimentally-fit positive exponent. This relationship is attributed to source-driven plasticity and demonstrates a strengthening as the decreasing sample size begins to limit the size and number of dislocation sources. A full understanding of this size-dependence is complicated by the presence of microstructural features such as interfaces that can compete with the dominant dislocation-based deformation mechanisms. In this thesis, the effects of microstructural features such as grain boundaries and anisotropic crystallinity on nano-scale metals are investigated through uniaxial compression testing. We find that nano-sized Cu covered by a hard coating displays a Bauschinger effect and the emergence of this behavior can be explained through a simple dislocation-based analytic model. Al nano-pillars containing a single vertically-oriented coincident site lattice grain boundary are found to show similar deformation to single-crystalline nano-pillars with slip traces passing through the grain boundary. With increasing tilt angle of the grain boundary from the pillar axis, we observe a transition from dislocation-dominated deformation to grain boundary sliding. Crystallites are observed to shear along the grain boundary and molecular dynamics simulations reveal a mechanism of atomic migration that accommodates boundary sliding. We conclude with an analysis of the effects of inherent crystal anisotropy and alloying on the mechanical behavior of the Mg alloy, AZ31. Through comparison to pure Mg, we show that the size effect dominates the strength of samples below 10 μm, that differences in the size effect between hexagonal slip systems is due to the inherent crystal anisotropy, suggesting that the fundamental mechanism of the size effect in these slip systems is the same.
Resumo:
Biological information storage and retrieval is a dynamic process that requires the genome to undergo dramatic structural rearrangements. Recent advances in single-molecule techniques have allowed precise quantification of the nano-mechanical properties of DNA [1, 2], and direct in vivo observation of molecules in action [3]. In this work, we will examine elasticity in protein-mediated DNA looping, whose structural rearrangement is essential for transcriptional regulation in both prokaryotes and eukaryotes. We will look at hydrodynamics in the process of viral DNA ejection, which mediates information transfer and exchange and has prominent implications in evolution. As in the case of Kepler's laws of planetary motion leading to Newton's gravitational theory, and the allometric scaling laws in biology revealing the organizing principles of complex networks [4], experimental data collapse in these biological phenomena has guided much of our studies and urged us to find the underlying physical principles.
Resumo:
Na Odontologia, ao se confeccionar peças restauradoras dentárias, pela técnica indireta, o processo mais rotineiramente empregado utiliza um modelo de gesso, obtido a partir de um molde de elastômero, tomado de um dente preparado. Vários fatores podem influenciar na boa precisão de ajustes destas peças como o escoamento do material de vazamento dentro da moldagem, a compatibilidade do material de vazamento com o da moldagem, o tempo de presa, a estabilidade dimensional, a resistência mecânica do material quando da separação moldagem/modelo, a resistência a abrasão e a fidelidade de reprodução de detalhes. Materiais foram introduzidos na odontologia para utilização na confecção de troquéis no intuito de minimizar as desvantagens do gesso, como baixa resistência a abrasão e ligeira expansão de presa. Dentre eles os troquéis metalizados e as resinas epóxicas, que tem vantagens em relação às propriedades mecânicas, porém o primeiro exige técnica demorada e de alto custo e o segundo apresenta contração. O presente trabalho se propõe a testar uma nova composição de poliéster insaturado com estireno adicionado ao carbonato de cálcio em diferentes proporções (10, 20, 30, 40, 50, 60 e 70%) e compará-la ao gesso tipo IV e a resina epoxídica com óxido de alumínio, através de ensaios mecânicos, de abrasão e de alteração dimensional, para avaliar a possibilidade de sua utilização como material de confecção de troquéis para a construção de restaurações indiretas. Para caracterização dos materiais foram feitas análises de espectrometria no infravermelho, Calorimetria de varredura diferencial, termogravimétrica e Microscopia eletrônica de varredura. O compósito a base de poliéster insaturado com 50% de carbonato de cálcio se mostrou viável para utilização como material para troquel. Quando comparado aos materiais de controle mostrou propriedades mecânicas próximas as da resina epoxídica e bem superiores ao gesso, resistência a abrasão superior ao gesso e inferior a resina epoxídica e alteração dimensional próxima a resina epoxídica e maior ao gesso. Sendo a formulação do poliéster/carbonato de cálcio apenas constituída de polímero, catalisador e carga, é possível melhorar a formulação modificando a carga e/ou acrescentando aditivos visando minimizar a contração de polimerização.
Resumo:
Quantum mechanics places limits on the minimum energy of a harmonic oscillator via the ever-present "zero-point" fluctuations of the quantum ground state. Through squeezing, however, it is possible to decrease the noise of a single motional quadrature below the zero-point level as long as noise is added to the orthogonal quadrature. While squeezing below the quantum noise level was achieved decades ago with light, quantum squeezing of the motion of a mechanical resonator is a more difficult prospect due to the large thermal occupations of megahertz-frequency mechanical devices even at typical dilution refrigerator temperatures of ~ 10 mK.
Kronwald, Marquardt, and Clerk (2013) propose a method of squeezing a single quadrature of mechanical motion below the level of its zero-point fluctuations, even when the mechanics starts out with a large thermal occupation. The scheme operates under the framework of cavity optomechanics, where an optical or microwave cavity is coupled to the mechanics in order to control and read out the mechanical state. In the proposal, two pump tones are applied to the cavity, each detuned from the cavity resonance by the mechanical frequency. The pump tones establish and couple the mechanics to a squeezed reservoir, producing arbitrarily-large, steady-state squeezing of the mechanical motion. In this dissertation, I describe two experiments related to the implementation of this proposal in an electromechanical system. I also expand on the theory presented in Kronwald et. al. to include the effects of squeezing in the presence of classical microwave noise, and without assumptions of perfect alignment of the pump frequencies.
In the first experiment, we produce a squeezed thermal state using the method of Kronwald et. al.. We perform back-action evading measurements of the mechanical squeezed state in order to probe the noise in both quadratures of the mechanics. Using this method, we detect single-quadrature fluctuations at the level of 1.09 +/- 0.06 times the quantum zero-point motion.
In the second experiment, we measure the spectral noise of the microwave cavity in the presence of the squeezing tones and fit a full model to the spectrum in order to deduce a quadrature variance of 0.80 +/- 0.03 times the zero-point level. These measurements provide the first evidence of quantum squeezing of motion in a mechanical resonator.
Resumo:
Computation technology has dramatically changed the world around us; you can hardly find an area where cell phones have not saturated the market, yet there is a significant lack of breakthroughs in the development to integrate the computer with biological environments. This is largely the result of the incompatibility of the materials used in both environments; biological environments and experiments tend to need aqueous environments. To help aid in these development chemists, engineers, physicists and biologists have begun to develop microfluidics to help bridge this divide. Unfortunately, the microfluidic devices required large external support equipment to run the device. This thesis presents a series of several microfluidic methods that can help integrate engineering and biology by exploiting nanotechnology to help push the field of microfluidics back to its intended purpose, small integrated biological and electrical devices. I demonstrate this goal by developing different methods and devices to (1) separate membrane bound proteins with the use of microfluidics, (2) use optical technology to make fiber optic cables into protein sensors, (3) generate new fluidic devices using semiconductor material to manipulate single cells, and (4) develop a new genetic microfluidic based diagnostic assay that works with current PCR methodology to provide faster and cheaper results. All of these methods and systems can be used as components to build a self-contained biomedical device.
Resumo:
The cataphoretic purification of helium was investigated for binary mixtures of He with Ar, Ne, N2, O2, CO, and CO2 in DC glow discharge. An experimental technique was developed to continuously measure the composition in the anode end-bulb without sample withdrawal. Discharge currents ranged from 10 ma to 100 ma. Total gas pressure ranged from 2 torr to 9 torr. Initial compositions of the minority component in He ranged from 1.2 mole percent to 7.5 mole percent.
The cataphoretic separation of Ar and Ne from He was found to be in agreement with previous investigators. The cataphoretic separation of N2, O2, and CO from He was found to be similar to noble gas systems in that the steady-state separation improved with (1) increasing discharge current, (2) increasing gas pressure, and (3) decreasing initial composition of the minority component. In the He-CO2 mixture, the CO2 dissociated to CO plus O2. The fraction of CO2 dissociated was directly proportional to the current and pressure and independent of initial composition.
The experimental results for the separation of Ar, Ne, N2, O2, and CO from He were interpreted in the framework of a recently proposed theoretical model involving an electrostatic Peclet number. In the model the electric field was assumed to be constant. This assumption was checked experimentally and the maximum variation in electric field was 35% in time and 30% in position. Consequently, the assumption of constant electric field introduced no more than 55% variation in the electrostatic Peclet number during a separation.
To aid in the design of new cataphoretic systems, the following design criteria were developed and tested in detail: (1) electric field independent of discharge current, (2) electric field directly proportional to total pressure, (3) ion fraction of impurity directly proportional to discharge current, and (4) ion fraction of impurity independent of total pressure. Although these assumptions are approximate, they enabled the steady-state concentration profile to be predicted to within 25% for 75% of the data. The theoretical model was also tested with respect to the characteristic time associated with transient cataphoresis. Over 80% of the data was within a factor of two of the calculated characteristic times.
The electrostatic Peclet number ranged in value from 0.13 to 4.33. Back-calculated ion fractions of the impurity component ranged in value from 4.8x10-6 to 178x10-6.