893 resultados para lumped-element filter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The proto-oncogene c-Myc is involved in early neoplastic transformations. Two consensus Lef/Tcf binding elements (TBE) were found to be prerequisite for transcriptional transactivation by the armadillo proteins beta-catenin and plakoglobin (PG) together with Tcf4 in human neoplastic cells. In epidermal keratinocytes, c-Myc was reported to be repressed by Lef-1 and PG. Using reporter gene assays, here we demonstrate that deletion of the two consensus TBE fails to abrogate transcriptional regulation by Lef-1/PG in wildtype and beta-catenin-/- keratinocytes, while it reduces transcription in pre-neoplastic PG-/- keratinocytes. We identified a TBE sequence variant downstream of the major transcriptional initiation site that binds Lef-1 in vitro and in vivo, and its mutation compromised transcriptional regulation by Lef-1/PG. Collectively, this study demonstrates that the two consensus TBE's reported in neoplastic cells are dispensable for c-Myc regulation in normal keratinocytes, which instead use a novel TBE sequence variant. This unprecedented finding may have important implications for armadillo target genes involved in carcinogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to propose a general numerical analysis methodology to evaluate the magnetic resonance imaging (MRI)-safety of active implants. Numerical models based on the finite element (FE) technique were used to estimate if the normal operation of an active device was altered during MRI imaging. An active implanted pump was chosen to illustrate the method. A set of controlled experiments were proposed and performed to validate the numerical model. The calculated induced voltages in the important electronic components of the device showed dependence with the MRI field strength. For the MRI radiofrequency fields, significant induced voltages of up to 20 V were calculated for a 0.3T field-strength MRI. For the 1.5 and 3.0T MRIs, the calculated voltages were insignificant. On the other hand, induced voltages up to 11 V were calculated in the critical electronic components for the 3.0T MRI due to the gradient fields. Values obtained in this work reflect to the worst case situation which is virtually impossible to achieve in normal scanning situations. Since the calculated voltages may be removed by appropriate protection circuits, no critical problems affecting the normal operation of the pump were identified. This study showed that the proposed methodology helps the identification of the possible incompatibilities between active implants and MR imaging, and can be used to aid the design of critical electronic systems to ensure MRI-safety

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSES: To evaluate the safety of inferior vena cava (IVC) filter retrieval in therapeutically anticoagulated patients in comparison to prophylactically or not therapeutically anticoagulated patients with respect to retrieval-related hemorrhagic complications. MATERIALS AND METHODS: This was a retrospective study of 115 consecutive attempted IVC filter retrievals in 110 patients. Filter retrievals were stratified as performed in patients who were therapeutically anticoagulated (group 1), prophylactically anticoagulated (group 2), or not therapeutically anticoagulated (group 3). The collected data included anticoagulant and antiplatelet medications (type, form and duration of administration, dosage) at the time of retrieval. Phone interviews and chart review was performed for the international normalized ratio (INR), activated partial thromboplastin time, platelet count, infusion of blood products, and retrieval-related hemorrhagic complications. RESULTS: Group 1 included 65 attempted filter retrievals in 61 therapeutically anticoagulated patients by measured INR or dosing when receiving low-molecular-weight heparin (LMWH). Four retrievals were not successful. In patients receiving oral anticoagulation, the median INR was 2.35 (range, 2 to 8). Group 2 comprised 23 successful filter retrievals in 22 patients receiving a prophylactic dose of LMWH. Group 3 included 27 attempted filter retrievals in 27 patients not receiving therapeutic anticoagulation. Six retrievals were not successful. Five patients were receiving oral anticoagulation with a subtherapeutic INR (median, 1.49; range, 1.16 to 1.69). No anticoagulation medication was administered in 22 patients. In none of the groups were hemorrhagic complications related to the retrieval procedures identified. CONCLUSIONS: These results suggest that retrieval of vena cava filters in anticoagulated patients is safe. Interruption or reversal of anticoagulation for the retrieval of vena cava filters is not indicated.