988 resultados para image indexing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims - To study the interchangeability of the measurements of the optic disc topography obtained by one computerised image analyser and one confocal laser tomographic scanner. Methods - One eye of 28 patients with glaucoma or glaucoma suspects was studied. All cases had simultaneous stereoscopic disc photographs taken with the fundus camera Topcon TRC-SS and optic disc examination with the Heidelberg retina tomograph (HRT) during the same visit. The optic disc photographs were digitised and analysed with the Topcon ImageNet (TI) system. Three variables of the optic disc topography provided by the TI and the HRT were compared - cup volume (CV), rim area (RA), and cup area to disc area ratio (CA/DA). Results - The mean values of CV and RA provided by the TI (0.52 (SD 0.32) mm and 1.58 (0.39) mm , respectively) were greater (p <0.01) than the mean values of CV and RA determined by the HRT (0.32 (0.25) mm , and 1.33 (0.47) mm , respectively). The mean value of CA/DA provided by the TI (0.42 (0.14)) and the HRT (0.42 (0.18)) was similar (p = 0.93). Correlation coefficients between measurements obtained by the two methods ranged from 0.53 to 0.73. Conclusion - There was a significant discrepancy in the measurements of rim area and cup volume of the optic disc obtained by a computerised image analyser and a laser scanning tomograph.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study was designed to evaluate the clinical agreement in the detection of optic disc changes and the ability of computerized image analysis to detect glaucomatous deterioration of the optic disc. Methods: Pairs of stereophotographs of 35 glaucomatous optic discs taken 5 years apart and of 5 glaucomatous discs photographed twice on the same day. Two glaucoma specialists examined the pairs of stereophotographs (35 cases and 5 controls) in a masked manner and judged whether the optic disc showed changes in the optic disc compatible with progression of glaucomatous damage. The stereophotographs of the five optic discs photographed twice on the same day (which by definition did not change) and of five cases judged to have deteriorated by both glaucoma specialists were analyzed by computerized image analysis with the Topcon ImageNet system. Intra- and inter-observer agreement in the detection of optic disc changes (evaluated using kappa statistic), and changes in the rim area to disc area ratio (evaluated using descriptive statistics and paired t-test). Results: Intra-observer agreement had a kappa value of 0.75 for observer 1 and 0.60 for the observer 2. Inter-observer agreement between the glaucoma specialists had a kappa value of 0.60. The image analyzer did not discriminate between controls and cases with clinically apparent glaucomatous change of the optic disc. Conclusion: Clinical agreement in detecting changes in the optic disc was moderate to substantial. Computerized image analysis with the Topcon ImageNet system appeared not to be useful in detecting glaucomatous changes of the optic disc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, gradient vector flow (GVF) based algorithms have been successfully used to segment a variety of 2-D and 3-D imagery. However, due to the compromise of internal and external energy forces within the resulting partial differential equations, these methods may lead to biased segmentation results. In this paper, we propose MSGVF, a mean shift based GVF segmentation algorithm that can successfully locate the correct borders. MSGVF is developed so that when the contour reaches equilibrium, the various forces resulting from the different energy terms are balanced. In addition, the smoothness constraint of image pixels is kept so that over- or under-segmentation can be reduced. Experimental results on publicly accessible datasets of dermoscopic and optic disc images demonstrate that the proposed method effectively detects the borders of the objects of interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ambisonics is a scalable spatial audio technique that attempts to present a sound scene to listeners over as large an area as possi- ble. A localisation experiment was carried out to investigate the performance of a first and third order system at three listening positions - one in the centre and two off-centre. The test used a reverse target-pointer adjustment method to determine the error, both signed and absolute, for each combination of listening posi- tion and system. The signed error was used to indicate the direc- tion and magnitude of the shifts in panning angle introduced for the off-centre listening positions. The absolute error was used as a measure of the performance of the listening position and systems combinations for a comparison of their overall performance. A comparison was made between the degree of image shifting be- tween the two systems and the robustness of their off-centre per- formance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blind steganalysis of JPEG images is addressed by modeling the correlations among the DCT coefficients using K -variate (K = 2) p.d.f. estimates (p.d.f.s) constructed by means of Markov random field (MRF) cliques. The reasoning of using high variate p.d.f.s together with MRF cliques for image steganalysis is explained via a classical detection problem. Although our approach has many improvements over the current state-of-the-art, it suffers from the high dimensionality and the sparseness of the high variate p.d.f.s. The dimensionality problem as well as the sparseness problem are solved heuristically by means of dimensionality reduction and feature selection algorithms. The detection accuracy of the proposed method(s) is evaluated over Memon's (30.000 images) and Goljan's (1912 images) image sets. It is shown that practically applicable steganalysis systems are possible with a suitable dimensionality reduction technique and these systems can provide, in general, improved detection accuracy over the current state-of-the-art. Experimental results also justify this assertion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Barrett's oesophagus (BO) is a well recognized precursor of the majority of cases of oesophageal adenocarcinoma (OAC). Endoscopic surveillance of BO patients is frequently undertaken in an attempt to detect early OAC, high grade dysplasia (HGD) or low grade dysplasia (LGD). However histological interpretation and grading of dysplasia is subjective and poorly reproducible. The alternative flow cytometry and cytology-preparation image cytometry techniques require large amounts of tissue and specialist expertise which are not widely available for frontline health care.
Methods: This study has combined whole slide imaging with DNA image cytometry, to provide a novel method for the detection and quantification of abnormal DNA contents. 20 cases were evaluated, including 8 Barrett's specialised intestinal metaplasia (SIM), 6 LGD and 6 HGD. Feulgen stained oesophageal sections (1µm thickness) were digitally scanned in their entirety and evaluated to select regions of interests and abnormalities. Barrett’s mucosa was then interactively chosen for automatic nuclei segmentation where irrelevant cell types are ignored. The combined DNA content histogram for all selected image regions was then obtained. In addition, histogram measurements, including 5c exceeding ratio (xER-5C), 2c deviation index (2cDI) and DNA grade of malignancy (DNA-MG), were computed.
Results: The histogram measurements, xER-5C, 2cDI and DNA-MG, were shown to be effective in differentiating SIM from HGD, SIM from LGD, and LGD from HGD. All three measurements discriminated SIM from HGD cases successfully with statistical significance (pxER-5C=0.0041, p2cDI=0.0151 and pDNA-MG=0.0057). Statistical significance is also achieved differentiating SIM from LGD samples with pxER-5C=0.0019, p2cDI=0.0023 and pDNA-MG=0.0030. Furthermore the differences between LGD and HGD cases are statistical significant (pxER-5C=0.0289, p2cDI=0.0486 and pDNA-MG=0.0384).
Conclusion: Whole slide image cytometry is a novel and effective method for the detection and quantification of abnormal DNA content in BO. Compared to manual histological review, this proposed method is more objective and reproducible. Compared to flow cytometry and cytology-preparation image cytometry, the current method is low cost, simple to use and only requires a single 1µm tissue section. Whole slide image cytometry could assist the routine clinical diagnosis of dysplasia in BO, which is relevant for future progression risk to OAC.