909 resultados para hemodynamic measurements
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
OBJECTIVE: The objective of this study was to investigate the associations between phase angle, anthropometric measurements, and lipid profile in patients chronically infected with the hepatitis C virus. METHODS: A total of 160 consecutive patients chronically infected with the hepatitis C virus and who received treatment at the hepatitis C outpatient unit of our hospital from April 2010 to May 2011 were prospectively evaluated. Bioelectrical impedance analysis, anthropometric measurements, and serum lipid profile analysis were performed. RESULTS: Twenty-five patients were excluded. A total of 135 patients with a mean age of 49.8±11.4 years were studied. Among these patients, 60% were male. The phase angle and BMI means were 6.5±0.8° and 26.5±4.8 kg/m2, respectively. Regarding anthropometric variables, mid-arm circumference, mid-arm muscle circumference, and arm muscle area had a positive correlation with phase angle. In contrast, when analyzing the lipid profile, only HDL was inversely correlated with phase angle. However, in multiple regression models adjusted for age and gender, only mid-arm circumference (p = 0.005), mid-arm muscle circumference (p = 0.003), and arm muscle circumference (p = 0.001) were associated with phase angle in hepatitis C virus-infected patients. CONCLUSIONS: In conclusion, phase angle is positively correlated with anthropometric measures in our study. However, there is no association between phase angle and lipid profile in these patients. Our results suggest that phase angle is related to lean body mass in patients chronically infected with hepatitis C virus.
Resumo:
OBJECTIVE: To verify if the reference values of Sleep Apnea cephalometric analysis of North American individuals are similar to the ones of Brazilian individuals presenting no craniofacial anomalies. The study also aimed to identify craniofacial alterations in Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS) patients in relation to individuals without clinical characteristics of the disease through this cephalometric analysis. METHOD: It were used 55 lateral cephalograms consisting of 29 for the control group of adult individuals without clinical characteristics of OSAHS and 26 apneic adults. All radiographs were submitted to Sleep Apnea cephalometric analysis through Radiocef Studio 2.0. The standard values of this analysis were compared, by means of z test, to the ones obtained from the control group and these were compared to values from apneic group through Student's t test. RESULTS: There were no significant differences between values obtained from control group and standard values. On the group of OSAHS patients it was observed a decrease on the dimensions of upper airways and an increase on the soft palate length. CONCLUSIONS: The standard values of Sleep Apnea analysis can be used as reference in Brazilian individuals. Besides, through lateral cephalograms it was possible to identify craniofacial alterations in OSAHS patients.
Resumo:
This study evaluated the effect of different protein sources (soybean meal, cottonseed meal, peanut meal and sunflower meal) on dry matter and nutrient intake, productive performance and body measurements of dairy heifers, Holstein x Zebu, recreated in confinement. The experiment consisted in a randomized complete block design made up by 6 replications and 4 treatments. The mean values of ingestion of ether extract (EEI, kg day-1) were statistically different (p < 0.05). The neutral detergent fiber intake (NDFI, %BW) also presented differences (p < 0.05), with higher values in the diet containing sunflower meal (1.01% BW) in relation to the diet with soybean meal (0.84% BW). The average daily weight gain using the diet with soybean meal was superior (0.95 kg day-1) to the diet with sunflower meal (0.82 kg day-1), and considering the final body weight, the diet with soybean meal was superior to the other treatments (p < 0.05). The heart girth presented greater association with body weight (0.93). The soybean meal promoted the best productive performance of crossbred Holstein x Zebu heifers fed diets based on sugarcane. However, cottonseed meal, peanut meal and sunflower meal can be possible alternatives to soybean meal.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: To compare dental plaster model (DPM) and cone-beam computed tomography (CBCT) in the measurement of the dental arches, and investigate whether CBCT image artifacts compromise the reliability of such measurements.Materials and Methods: Twenty patients were divided into two groups based on the presence or absence of metallic restorations in the posterior teeth. Both dental arches of the patients were scanned with the CBCT unit i-CAT, and DPMs were obtained. Two examiners obtained eight arch measurements on the CBCT images and DPMs and repeated this procedure 15 days later. The arch measurements of each patient group were compared separately by the Wilcoxon rank sum (Mann-Whitney U) test, with a significance level of 5% (alpha = .05). Intraclass correlation measured the level of intraobserver agreement.Results: Patients with healthy teeth showed no significant difference between all DPM and CBCT arch measurements (P > .05). Patients with metallic restoration showed significant difference between DPM and CBCT for the majority of the arch measurements (P > .05). The two examiners showed excellent intraobserver agreement for both measuring methods with intraclass correlation coefficient higher than 0.95.Conclusion: CBCT provided the same accuracy as DPM in the measurement of the dental arches, and was negatively influenced by the presence of image artifacts.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Recalibration of U-doped standard glasses through uranium thin film for neutron-fluence measurements
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Sildenafil attenuates acute pulmonary embolism-induced pulmonary hypertension. However, the hemodynamic effects of sildenafil in combination with other vasodilators during acute pulmonary embolism have not been examined yet. In the present study, we examined the hemodynamic effects of combined sildenafil (0.25 mg/kg, i.v.) and L-arginine (100, 200, 500, and 1000 mg/kg/h, i.v.) in an anesthetized dog model of acute pulmonary embolism. Plasma nitrite/nitrate (NOx) and cGMP concentrations were determined using an ozone-based chemiluminescence assay and a commercial enzyme immunoassay, respectively. We found that L-arginine alone did not attenuate acute pulmonary embolism-induced pulmonary hypertension. However, significant decreases in mean pulmonary artery pressure were observed 30, 45, 60, and 75 min after the administration of sildenafil alone or after the combined administration of sildenafil and L-arginine (all P<0.05). No significant differences among groups were observed in the respiratory parameters. While L-arginine significantly increased NOx concentrations, cGMP concentrations increased only when sildenafil was administered (all P<0.05). These results suggest that while sildenafil attenuates acute pulmonary embolism-induced pulmonary hypertension, L-arginine does not enhance the beneficial hemodynamic effects of sildenafil. In addition, these findings suggest that stimulation of NO synthesis with L-arginine during acute pulmonary embolism does not produce beneficial effects. (c) 2005 Elsevier B.V. All rights reserved.