956 resultados para fecal pH


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia e Ciência de Alimentos - IBILCE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temporary B deficiency can be triggered by liming of acid soils because of increased B adsorption at higher soil pH. Plants respond directly to the activity of B in soil solution and only indirectly to B adsorbed on soil constituents. Because the range between deficient and toxic B concentration is relatively narrow, this poses difficulty in maintaining appropriate B levels in soil solution. Thus, knowledge of the chemical behavior of B in the soil is particularly important. The present study investigated the effect of soil pH on B adsorption in four soils of Parana State, and to correlate these values with the physical and chemical properties of the soils. Surface samples were taken from a Rhodic Hapludox, Arenic Hapludalf, Arenic Hapludult, and one Typic Usthorthent. To evaluate the effect of pH on B adsorption, subsamples soil received the application of increasing rates of calcium carbonate. Boron adsorption was accomplished by shaking 2.0 g soil, for 24 h, with 20 mL of 0.01 mol L-1 NaCl solution containing different concentrations (0.0, 0.1, 0.2, 0.4, 0.8, 1.2, 1.6, 2.0, and 4.0 mg B L-1). Sorption was fitted to non-linear form of the Langmuir adsorption isotherm. Boron adsorption increased as concentration increased. Boron adsorption was dependent on soil pH, increasing as a function of pH in the range between 4.6 and 7.4, although the bonding energy has decreased. Maximum adsorption capacity (MAC) of B was observed in the Arenic Hapludalf (49.8 mg B kg(-1) soil) followed by Arenic Hapludult (22.5 mg kg(-1)), Rhodic Hapludox (17.4 mg kg(-1)), and Typic Usthorthent (7.0 mg kg(-1)). The organic matter content, clay content, and aluminum oxide content (Al2O3) were the soils properties that affecting the B adsorption on Parana soils.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study isolated and quantified intestinal bacteria of children with cleft palate before and after palatoplasty. A prospective study was conducted from May 2007 to September 2008 on 18 children with cleft palate, aged one to four years, of both genders, attending a tertiary cleft center in Brazil for palatoplasty, to analyze the effect of surgical palate repair on the concentration of anaerobes Bacteroides sp, Bifidobacterium sp and microaerophiles Lactobacillus sp in feces of infants with cleft palate before and 24 hours after treatment with cefazolin for palatoplasty. There was significant reduction of Lactobacillus sp (p < 0.002), Bacteroides sp (p < 0.001) and Bifidobacterium sp (p = 0.021) after palatoplasty, revealing that surgery and utilization of cefazolin significantly influenced the fecal microbiota comparing collections before and after surgery. However, due to study limitations, it was not possible to conclude that other isolated factors, such as surgical stress, anesthetics and other medications used in palatoplasty might have a significant influence on the microbiota. Considering the important participation of the intestinal microbiota on both local and systemic metabolic and immunological activities of the host, professionals should be attentive to the possible influence of these changes in patients submitted to cleft repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zymomonas mobilis was immobilized using a cell suspension fixed to 8.6 x 10(7) CFU mL(-1) by spectrophotometry. This biomass was suspended in sodium alginate solution (3%) that was dropped with a hypodermic syringe into 0.2 M calcium chloride solution. Was test two initial pH of fermentation medium (4 and 5) and different sucrose concentrations 15, 20, 25, 30 and 35% at 30 degrees C, without stirring for 24, 48, 72 and 96 hours. The levan production to pH 4 was high in sucrose 25% for 24 (16.51 g L-1) and 48 (15.31 g L-1) hours. The best values obtained to pH 5 was in sucrose 35% during 48 (22.39 g L-1) and 96 (23.5 g L-1) hours, respectively. The maximum levan yield was 40.8% and 22.47% in sucrose 15% to pH 4 and 5, respectively. Substrate consumption to pH 4 was bigger in sucrose 15 (56.4%) and 20% (59.4%) and to pH 5 was in 25 (68.85%) and 35% (64.64%). In relation to immobilization efficiency, Zymomonas mobilis showed high adhesion and colonization in support, indicated by cell growth increased from 107 to 10(9) CFU mL(-1) during fermentation time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural component failures due to cyclic loading are associated to surface damage of materials and its interaction with environment. Fatigue failure occurs with stresses below the yield strength of each material and is a result of crack initiation and propagation. In aeronautical components is an important parameter to be considered in project, as well as the corrosion and wear resistance. Thermally sprayed HVOF coatings have been considered to replace galvanic chromium deposits with comparable performance for wear and corrosion resistance. The aim of present research is to study the influence of WC-13Co-4Cr applied by HVOF, on the axial fatigue strength of 15-5 PH stainless steel. The shot peening treatment was used to restore fatigue performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atualmente o titânio é empregado como biomaterial devido à sua biocompatibilidade e resistência à corrosão. Entretanto, íons fluoretos, freqüentemente empregados em dentifrícios bucais, podem interferir no processo de corrosão. O objetivo deste estudo foi analisar a influência de um meio fluoretado com diferentes pH nas propriedades mecânicas e na resistência à corrosão dos conjuntos implantes/componentes protéticos à base de Ti c.p., a partir dos testes de fadiga, microscopia eletrônica de varredura (MEV) e dureza. Foram simulados cinco anos de uso regular de meios de higiene oral com conteúdo de 1500 ppm de NaF, com dois diferentes pH, 7,4 e 5,3, mediante imersão das amostras nesses meios durante 184 horas e também em água destilada, grupo controle. As amostras foram testadas num durômetro Micromet 2001 (500gf/30s). Os dados dos testes de dureza foram analisados pelo teste de Wilcoxon, demonstrando que as amostras sofreram influência negativa na dureza após a ação dos íons fluoreto. Entretanto, essa influência não ocorreu nos testes de fadiga realizados em uma máquina de ensaios mecânicos MTS-810, fixada a 100.000 ciclos, 15Hz e programada com força de fadiga a 150 N. Pela análise de MEV foram constatadas evidências de corrosão na superfície das amostras após ação de íons fluoretos, entretanto pelo EDS não se verificou incorporação de íons fluoretos sobre a superfície dos conjuntos. Concluiu-se que a concentração de flúor e o pH das soluções não exerceram influência nas propriedades mecânicas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar o pH e a densidade óptica das soluções de azul de metileno a 1% e 2% (tamponadas e não tamponadas) após a imersão de três cimentos endodônticos. Foram preparados oitenta espécimes de cada cimento endodôntico (Endofill, AH Plus e Sealapex), os quais foram imersos nas soluções corantes. As soluções foram analisadas antes e após a imersão dos materiais nos períodos de tempo de 0, 24, 48 e 72h. Foram realizadas avaliações do pH utilizando um pHmetro e da densidade óptica utilizando um espectofotômetro ajustado em 596nm. Os dados de pH foram analisados através de estatística descritiva e os dados da densidade óptica foram analisados pela ANOVA e teste de Tukey 5%. Pôde-se verificar que as soluções corantes de azul de metileno tamponadas e não tamponadas apresentaram pequena variação nos valores de pH e densidade óptica antes do contato com os cimentos endodônticos. As soluções corantes não tamponadas apresentaram valores de pH menores que as tamponadas, independentemente do contato com qualquer cimento endodôntico. Os cimentos endodônticos promoveram alterações nos valores de pH das soluções corantes, sendo que as maiores alterações ocorreram nas soluções não tamponadas. Ocorreram alterações nos valores da densidade óptica das soluções corantes tamponadas e não tamponadas nos diferentes períodos de tempo de análise, sendo diferentes para cada cimento endodôntico utilizado

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)