997 resultados para estimated parameters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 4πβ-γ coincidence counting method and its close relatives are widely used for the primary standardization of radioactivity. Both the general formalism and specific implementation of these methods have been well-documented. In particular, previous papers contain the extrapolation equations used for various decay schemes, methods for determining model parameters and, in some cases, tabulated uncertainty budgets. Two things often lacking from experimental reports are both the rationale for estimating uncertainties in a specific way and the details of exactly how a specific component of uncertainty was estimated. Furthermore, correlations among the components of uncertainty are rarely mentioned. To fill in these gaps, the present article shares the best-practices from a few practitioners of this craft. We explain and demonstrate with examples of how these approaches can be used to estimate the uncertainty of the reported massic activity. We describe uncertainties due to measurement variability, extrapolation functions, dead-time and resolving-time effects, gravimetric links, and nuclear and atomic data. Most importantly, a thorough understanding of the measurement system and its response to the decay under study can be used to derive a robust estimate of the measurement uncertainty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intravoxel incoherent motion (IVIM) MRI is a method to extract microvascular blood flow information out of diffusion-weighted images acquired at multiple b-values. We hypothesized that IVIM can identify the muscles selectively involved in a specific task, by measuring changes in activity-induced local muscular perfusion after exercise. We tested this hypothesis using a widely used clinical maneuver, the lift-off test, which is known to assess specifically the subscapularis muscle functional integrity. Twelve shoulders from six healthy male volunteers were imaged at 3 T, at rest, as well as after a lift-off test hold against resistance for 30 s, 1 and 2 min respectively, in three independent sessions. IVIM parameters, consisting of perfusion fraction (f), diffusion coefficient (D), pseudo-diffusion coefficient D* and blood flow-related fD*, were estimated within outlined muscles of the rotator cuff and the deltoid bundles. The mean values at rest and after the lift-off tests were compared in each muscle using a one-way ANOVA. A statistically significant increase in fD* was measured in the subscapularis, after a lift-off test of any duration, as well as in D. A fD* increase was the most marked (30 s, +103%; 1 min, +130%; 2 min, +156%) and was gradual with the duration of the test (in 10(-3) mm(2) /s: rest, 1.41 ± 0.50; 30 s, 2.86 ± 1.17; 1 min, 3.23 ± 1.22; 2 min, 3.60 ± 1.21). A significant increase in fD* and D was also visible in the posterior bundle of the deltoid. No significant change was consistently visible in the other investigated muscles of the rotator cuff and the other bundles of the deltoid. In conclusion, IVIM fD* allows the demonstration of a task-related microvascular perfusion increase after a specific task and suggests a direct relationship between microvascular perfusion and the duration of the effort. It is a promising method to investigate non-invasively skeletal muscle physiology and clinical perfusion-related muscular disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapid manufacturing is an advanced manufacturing technology based on layer-by-layer manufacturing to produce a part. This paper presents experimental work carried out to investigate the effects of scan speed, layer thickness, and building direction on the following part features: dimensional error, surface roughness, and mechanical properties for DMLS with DS H20 powder and SLM with CL 20 powder (1.4404/AISI 316L). Findings were evaluated using ANOVA analysis. According to the experimental results, build direction has a significant effect on part quality, in terms of dimensional error and surface roughness. For the SLM process, the build direction has no influence on mechanical properties. Results of this research support industry estimating part quality and mechanical properties before the production of parts with additive manufacturing, using iron-based powders

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Reference intervals for many laboratory parameters determined in 24-h urine collections are either not publicly available or based on small numbers, not sex specific or not from a representative sample. METHODS: Osmolality and concentrations or enzymatic activities of sodium, potassium, chloride, glucose, creatinine, citrate, cortisol, pancreatic α-amylase, total protein, albumin, transferrin, immunoglobulin G, α1-microglobulin, α2-macroglobulin, as well as porphyrins and their precursors (δ-aminolevulinic acid and porphobilinogen) were determined in 241 24-h urine samples of a population-based cohort of asymptomatic adults (121 men and 120 women). For 16 of these 24 parameters creatinine-normalized ratios were calculated based on 24-h urine creatinine. The reference intervals for these parameters were calculated according to the CLSI C28-A3 statistical guidelines. RESULTS: By contrast to most published reference intervals, which do not stratify for sex, reference intervals of 12 of 24 laboratory parameters in 24-h urine collections and of eight of 16 parameters as creatinine-normalized ratios differed significantly between men and women. For six parameters calculated as 24-h urine excretion and four parameters calculated as creatinine-normalized ratios no reference intervals had been published before. For some parameters we found significant and relevant deviations from previously reported reference intervals, most notably for 24-h urine cortisol in women. Ten 24-h urine parameters showed weak or moderate sex-specific correlations with age. CONCLUSIONS: By applying up-to-date analytical methods and clinical chemistry analyzers to 24-h urine collections from a large population-based cohort we provide as yet the most comprehensive set of sex-specific reference intervals calculated according to CLSI guidelines for parameters determined in 24-h urine collections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Ski mountaineering is an increasingly popular winter sport and leisure activity. Elite athletes practice this sport with a high level of professionalism, but so far little scientific evidence was available to support their approach. The main aim of this work was to develop a specific knowledge about ski mountaineering, allowing providing specific recommendations for the practice. Methods: First we investigated energy cost (EC) and vertical energy cost (ECv). These two parameters were estimated with oxygen uptake, at different gradients (7 to 33%) and different speeds (2 to 7 km·∙h-­‐1) on treadmill with roller skis and on snow with ski mountaineering gear. Then we assessed energy expenditure (EE) during a long duration ski mountaineering event by measuring heart rate and altitude all along the race and associating them with an EE. The EE was compared with the energy intake during the race. Hydration level was estimated by comparing body weight immediately before and after the race. The energy intake during the 4 days preceding the race was estimated with food diaries and compared with the guidelines. Results/discussion: EC and ECv of ski mountaineering were very high and varied with gradient and speed. ECv decreased between 7 and 33% and with increasing speed at steep gradients. For a 5 h 51 ± 53 min race, the mean EE was 22.6 ± 2.6 MJ. The energy intake covered 20 ± 7% of the EE and was about 14% lower than the recommendations. No significant dehydration was observed. For the longest (53 km) race, we can extrapolate the EE as about 40 MJ. Before the race the energy intake and especially the carbohydrate intake were far under the guidelines (83 ± 17% and 46 ± 13% of the recommendations). Conclusions: EC and EE of ski mountaineering are very high. To minimize the EE to reach the top of a mountain and optimize the performance, the skier should choose a steep gradient and combine this steep gradient with a fast speed. The CHO intake should be increased during but, also before the race while the fluid intake seemed to be adequate. -- Introduction : Le ski-­‐alpinisme est un sport d'hiver qui s'est particulièrement développé durant les dernières décennies : de plus en plus de personnes pratiquent cette activité dans un cadre de loisirs et de plus en plus d'athlètes d'élite prennent part à des compétitions qu'ils préparent avec un haut degré de professionnalisme. Cependant, les connaissances scientifiques restent limitées et les athlètes ne disposent pas de recommandations précises et spécifiques. Le but principal de ce travail est donc de développer un savoir spécifique sur le ski-­‐alpinisme, ce qui devrait permettre d'établir des recommandations pour la pratique. Méthode : Le coût énergétique (CE) et le coût énergétique vertical (CEv) du ski-­‐alpinisme ont été calculés en mesurant la consommation d'oxygène à différentes pentes (7 à 33%) et vitesses (2 à 6.8 km·∙h-­‐1) sur tapis roulant avec des skis à roulettes et sur le terrain avec des skis de randonnée. Ensuite, la dépense énergétique (DE) d'une course de ski-­‐alpinisme de longue durée a été évaluée en mesurant la fréquence cardiaque et l'altitude en continu. La DE a été comparée à l'énergie consommée par les ravitaillements. Des carnets alimentaires ont permis d'estimer la consommation d'énergie (boissons et nourriture) pendant les 4 jours précédant la course. Résultats/discussion : Le CE du ski-­‐alpinisme est très élevé. Le CEv diminue entre 2 et 6 km·∙h-­‐1 et entre 7 et 33%. Pour une course de 5 h 51 ± 53 min (26 km), la DE était de 22.6 ± 2.6 MJ, alors que, pour le grand parcours de la Patrouille des Glaciers (53 km), elle serait d'environ 40 MJ. La consommation d'énergie, pendant le parcours de 26 km, couvrait 20 ± 7% de la DE et était inférieure de 14% aux recommandations, alors qu'aucune déshydratation significative n'était constatée. Les jours précédant la course, la consommation d'énergie et surtout d'hydrates de carbone était bien inférieure aux quantités recommandées (83 ± 17% et 46 ± 13% des recommandations). Conclusion : Le CE et la DE étaient très élevés. Pour minimiser la dépense lors d'une ascension, il faut combiner pente et vitesse élevées. La consommation d'hydrates de carbone devrait être massivement augmentée avant et pendant la course, alors que l'hydratation semble adéquate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To develop procedures to ensure consistency of printing quality of digital images, by means of hardcopy quantitative analysis based on a standard image. Materials and Methods Characteristics of mammography DI-ML and general purpose DI-HL films were studied through the QC-Test utilizing different processing techniques in a FujiFilm®-DryPix4000 printer. A software was developed for sensitometric evaluation, generating a digital image including a gray scale and a bar pattern to evaluate contrast and spatial resolution. Results Mammography films showed maximum optical density of 4.11 and general purpose films, 3.22. The digital image was developed with a 33-step wedge scale and a high-contrast bar pattern (1 to 30 lp/cm) for spatial resolution evaluation. Conclusion Mammographic films presented higher values for maximum optical density and contrast resolution as compared with general purpose films. The utilized digital processing technique could only change the image pixels matrix values and did not affect the printing standard. The proposed digital image standard allows greater control of the relationship between pixels values and optical density obtained in the analysis of films quality and printing systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to estimate the energy cost of linear (EC) and vertical displacement (ECvert), mechanical efficiency and main stride parameters during simulated ski mountaineering at different speeds and gradients, to identify an optimal speed and gradient that maximizes performance. 12 subjects roller skied on a treadmill at three different inclines (10, 17 and 24 %) at three different speeds (approximately 70, 80 and 85 % of estimated peak heart rate). Energy expenditure was calculated by indirect calorimetry, while biomechanical parameters were measured with an inertial sensor-based system. At 10 % there was no significant change with speed in EC, ECvert and mechanical efficiency. At 17 and 24 % the fastest speed was significantly more economical. There was a significant effect of gradient on EC, ECvert and mechanical efficiency. The most economical gradient was the steepest one. There was a significant increase of stride frequency with speed. At steep gradients only, relative thrust phase duration decreased significantly, while stride length increased significantly with speed. There was a significant effect of gradient on stride length (decrease with steepness) and relative thrust phase duration (increase with steepness). A combination of a decreased relative thrust phase duration with increased stride length and frequency decreases ECvert. To minimize the energy expenditure to reach the top of a mountain and to optimize performance, ski-mountaineers should choose a steep gradient (~24 %) and, provided they possess sufficient metabolic scope, combine it with a fast speed (~6 km h(-1)).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.Materials and Methods:Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A – 551 studies) and three months after (group B – 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.Results:A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).Conclusion:The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:The present study is aimed at contributing to identify the most appropriate OSEM parameters to generate myocardial perfusion imaging reconstructions with the best diagnostic quality, correlating them with patients' body mass index.Materials and Methods:The present study included 28 adult patients submitted to myocardial perfusion imaging in a public hospital. The OSEM method was utilized in the images reconstruction with six different combinations of iterations and subsets numbers. The images were analyzed by nuclear cardiology specialists taking their diagnostic value into consideration and indicating the most appropriate images in terms of diagnostic quality.Results:An overall scoring analysis demonstrated that the combination of four iterations and four subsets has generated the most appropriate images in terms of diagnostic quality for all the classes of body mass index; however, the role played by the combination of six iterations and four subsets is highlighted in relation to the higher body mass index classes.Conclusion:The use of optimized parameters seems to play a relevant role in the generation of images with better diagnostic quality, ensuring the diagnosis and consequential appropriate and effective treatment for the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nombreux sont les groupes de recherche qui se sont intéressés, ces dernières années, à la manière de monitorer l'entraînement des sportifs de haut niveau afin d'optimaliser le rendement de ce dernier tout en préservant la santé des athlètes. Un des problèmes cardinaux d'un entraînement sportif mal conduit est le syndrome du surentraînement. La définition du syndrome susmentionné proposée par Kreider et al. est celle qui est actuellement acceptée par le « European College of Sport Science » ainsi que par le « American College of Sports Medicine», à savoir : « An accumulation of training and/or non-training stress resulting in long-term decrement in performance capacity with or without related physiological and psychological signs and symptoms of maladaptation in which restoration of performance capacity may take several weeks or months. » « Une accumulation de stress lié, ou non, à l'entraînement, résultant en une diminution à long terme de la capacité de performance. Cette dernière est associée ou non avec des signes et des symptômes physiologiques et psychologiques d'inadaptation de l'athlète à l'entraînement. La restauration de ladite capacité de performance peut prendre plusieurs semaines ou mois. » Les recommandations actuelles, concernant le monitoring de l'entraînement et la détection précoce du syndrome du surentrainement, préconisent, entre autre, un suivi psychologique à l'aide de questionnaires (tel que le Profile of Mood State (POMS)), un suivi de la charge d'entraînement perçue par l'athlète (p.ex. avec la session rating of perceived exertion (RPE) method selon C. Foster), un suivi des performances des athlètes et des charges d'entraînement effectuées ainsi qu'un suivi des problèmes de santé (blessures et maladies). Le suivi de paramètres sanguins et hormonaux n'est pas recommandé d'une part pour des questions de coût et de faisabilité, d'autre part car la littérature scientifique n'a, jusqu'ici, pas été en mesure de dégager des évidences à ce sujet. A ce jour, peu d'études ont suivi ces paramètres de manière rigoureuse, sur une longue période et chez un nombre d'athlète important. Ceci est précisément le but de notre étude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective: To estimate the entrance surface air kerma (Ka,e) and air kerma in the region of radiosensitive organs in radiographs of pediatric paranasal sinuses. Materials and Methods: Patient data and irradiation parameters were collected in examinations of the paranasal sinuses in children from 0 to 15 years of age at two children's hospitals in the city of Recife, PE, Brazil. We estimated the Ka,e using the X-ray tube outputs and selected parameters. To estimate the air kerma values in the regions of the eyes and thyroid, we used thermoluminescent dosimeters. Results: The Ka,e values ranged from 0.065 to 1.446 mGy in cavum radiographs, from 0.104 to 7.298 mGy in Caldwell views, and from 0.113 to 7.824 mGy in Waters views. Air kerma values in the region of the eyes ranged from 0.001 to 0.968 mGy in cavum radiographs and from 0.011 to 0.422 mGy in Caldwell and Waters views . In the thyroid region, air kerma values ranged from 0.005 to 0.932 mGy in cavum radiographs and from 0.002 to 0.972 mGy in Caldwell and Waters views. Conclusion: The radiation levels used at the institutions under study were higher than those recommended in international protocols. We recommend that interventions be initiated in order to reduce patient exposure to radiation and therefore the risks associated with radiological examination of the paranasal sinuses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chemistry of gold dissolution in alkaline cyanide solution has continually received attention and new rate equations expressing the gold leaching are still developed. The effect of leaching parameters on gold gold cyanidation is studied in this work in order to optimize the leaching process. A gold leaching model, based on the well-known shrinking-core model, is presented in this work. It is proposed that the reaction takes place at the reacting particle surface which is continuously reduced as the reaction proceeds. The model parameters are estimated by comparing experimental data and simulations. The experimental data used in this work was obtained from Ling et al. (1996) and de Andrade Lima and Hodouin (2005). Two different rate equations, where the unreacted amount of gold is considered in one equation, are investigated. In this work, it is presented that the reaction at the surface is the rate controlling step since there is no internal diffusion limitation. The model considering the effect of non-reacting gold shows that the reaction orders are consistent with the experimental observations reported by Ling et al. (1996) and de Andrade Lima and Hodouin (2005). However, it should be noted that the model obtained in this work is based on assumptions of no side reactions, no solid-liquid mass transfer resistances and no effect from temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Turun seudulla kuuden kunnan jätevesien käsittely keskitetään Kakolanmäen kallion sisälle rakennettuun jätevedenpuhdistamoon, joka otetaan käyttöön vuoden 2008 lopulla. Kakolanmäen jätevedenpuhdistamolla on varauduttu tulevaisuudessa kiristyviin lupaehtoihin sekä mahdollisiin puhdistetun jäteveden hygieenistä laatua koskeviin lisämääräyksiin jättämällä tilavaraus puhdistetun jäteveden desinfioimiselle ultraviolettivalolla. Diplomityössä on selvitetty vuoden kestäneessä tutkimusjaksossa 1.9.2006- 31.8.2007 Turun kaupungin keskuspuhdistamolta mereen johdetun puhdistetun jäteveden ja esiselkeytetyn ohitusveden hygieenisen laadun vaihtelua. Jäteveden desinfiointitarvetta on arvioitu tarkastelemalla jätevedenpuhdistamon hygieenistä puhdistustulosta ja jätevesien vaikutusta purkuvesistön hygieeniseen tilaan. Tutkimuksen perusteella virtaama ei vaikuttanut merkittävästi jäteveden ulosteperäisten bakteerien määriin. Sen sijaan jäteveden bakteeripitoisuudet laskivat alhaisissa lämpötiloissa. Lämpötilan vaikutus näkyi selkeämmin esiselkeytetyssä kuin puhdistetussa jätevedessä eli bakteerien poistumiseen aktiivilietevaiheen aikana vaikuttavat muut tekijät. Mitä tehokkaammin aktiivilietevaihe toimi, sitä tehokkaammin myös bakteereja poistui. Taudinaiheuttajabakteerit selvisivät puhdistusprosessista paremmin viileän kauden aikana. Puhdistetun jäteveden hygieeninen laatu ei täyttänyt uimaveden tai kasteluveden laatuvaatimuksia, joten desinfiointitarve olisi perustelua. Jätevesien vaikutus Turun edustan merialueen hygieeniseen tilaan näkyi ajoittain korkeina bakteeripitoisuuksina purkupaikan lähistöllä. Vielä ei ole suoraa näyttöä siitä aiheuttavatko jätevedet purkupaikan lähistön uimarannoilla terveydellisiä riskejä. Jäteveden UV-desinfiointi kannattava toteuttaa vain jos hygieeninen puhdistusvelvoite määrätään. UV-desinfioinnin mitoituksessa Kakolanmäen jätevedenpuhdistamolla tulee ottaa huomioon suurin sallittu hydraulinen painehäviö. Mitoitus voidaan tehdä puhdistamon käyttöönoton jälkeen kun tarvitut prosessimittaustiedot ovat saatavilla.