963 resultados para efficacité du ct-scan


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dental identification is the most valuable method to identify human remains in single cases with major postmortem alterations as well as in mass casualties because of its practicability and demanding reliability. Computed tomography (CT) has been investigated as a supportive tool for forensic identification and has proven to be valuable. It can also scan the dentition of a deceased within minutes. In the present study, we investigated currently used restorative materials using ultra-high-resolution dual-source CT and the extended CT scale for the purpose of a color-encoded, in scale, and artifact-free visualization in 3D volume rendering. In 122 human molars, 220 cavities with 2-, 3-, 4- and 5-mm diameter were prepared. With presently used filling materials (different composites, temporary filling materials, ceramic, and liner), these cavities were restored in six teeth for each material and cavity size (exception amalgam n = 1). The teeth were CT scanned and images reconstructed using an extended CT scale. Filling materials were analyzed in terms of resulting Hounsfield units (HU) and filling size representation within the images. Varying restorative materials showed distinctively differing radiopacities allowing for CT-data-based discrimination. Particularly, ceramic and composite fillings could be differentiated. The HU values were used to generate an updated volume-rendering preset for postmortem extended CT scale data of the dentition to easily visualize the position of restorations, the shape (in scale), and the material used which is color encoded in 3D. The results provide the scientific background for the application of 3D volume rendering to visualize the human dentition for forensic identification purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated whether measurements on conventional frontal radiographs are comparable with measurements on cone beam computed tomography (CBCT)-constructed frontal cephalometric radiographs taken from dry human skulls. CBCT scans and conventional frontal cephalometric radiographs were made of 40 dry skulls. With I-Cat Vision((R)) software, a cephalometric radiograph was constructed from the CBCT scan. Standard cephalometric software was used to identify landmarks and calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs on all Images 5 times with a time-interval of 1 week. Intra-observer reliability was acceptable for all measurements. The reproducibility of the measurements on the frontal radiographs obtained from the CBCT scans was higher than those on conventional frontal radiographs. There is a statistically significant and clinically relevant difference between measurements on conventional and constructed frontal radiographs. There is a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements on frontal cephalometric radiographs constructed from CBCT scans, owing to different positioning of patients in both devices. Positioning of the patient in the CBCT device appears to be an important factor in cases where a 2D projection of the 3D scan is made.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Leptospirosis pulmonary haemorrhage syndrome (LPHS) is a frequent manifestation of Leptospira infection in dogs and is associated with a high morbidity and mortality. Three helical 16-slice thoracic CT scans were performed in 10 dogs naturally infected with Leptospira, within 24 hours of admission, and three and seven days later. Patients were sedated and scanned without breathhold, with a protocol adapted for rapid scanning. One dog died of respiratory failure on the morning following the first scan. On the initial scan, imaging features of LPHS included ground-glass nodules (10/10), peribronchovascular interstitial thickening (10/10), diffuse or patchy ground-glass opacity (9/10), solid nodules (8/10) and consolidation (7/10). Temporary bronchiolar dilation was observed in all dogs in association with peribronchovascular interstitial thickening, which had completely resolved at day 7. Nodules were with few exceptions assigned to the centrilobular region. Regression of lesion severity was observed after each subsequent scan. Consolidation and solid nodules changed over time into lesions of ground-glass attenuation. Pleural effusion (3/10) and mediastinal effusion (2/10) were mild and transient. Lesion severity appeared unassociated with survival to discharge.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM To compare the computed tomography (CT) dose and image quality with the filtered back projection against the iterative reconstruction and CT with a minimal electronic noise detector. METHODS A lung phantom (Chest Phantom N1 by Kyoto Kagaku) was scanned with 3 different CT scanners: the Somatom Sensation, the Definition Flash and the Definition Edge (all from Siemens, Erlangen, Germany). The scan parameters were identical to the Siemens presetting for THORAX ROUTINE (scan length 35 cm and FOV 33 cm). Nine different exposition levels were examined (reference mAs/peek voltage): 100/120, 100/100, 100/80, 50/120, 50/100, 50/80, 25/120, 25/100 and 25 mAs/80 kVp. Images from the SOMATOM Sensation were reconstructed using classic filtered back projection. Iterative reconstruction (SAFIRE, level 3) was performed for the two other scanners. A Stellar detector was used with the Somatom Definition Edge. The CT doses were represented by the dose length products (DLPs) (mGycm) provided by the scanners. Signal, contrast, noise and subjective image quality were recorded by two different radiologists with 10 and 3 years of experience in chest CT radiology. To determine the average dose reduction between two scanners, the integral of the dose difference was calculated from the lowest to the highest noise level. RESULTS When using iterative reconstruction (IR) instead of filtered back projection (FBP), the average dose reduction was 30%, 52% and 80% for bone, soft tissue and air, respectively, for the same image quality (P < 0.0001). The recently introduced Stellar detector (Sd) lowered the radiation dose by an additional 27%, 54% and 70% for bone, soft tissue and air, respectively (P < 0.0001). The benefit of dose reduction was larger at lower dose levels. With the same radiation dose, an average of 34% (22%-37%) and 25% (13%-46%) more contrast to noise was achieved by changing from FBP to IR and from IR to Sd, respectively. For the same contrast to noise level, an average of 59% (46%-71%) and 51% (38%-68%) dose reduction was produced for IR and Sd, respectively. For the same subjective image quality, the dose could be reduced by 25% (2%-42%) and 44% (33%-54%) using IR and Sd, respectively. CONCLUSION This study showed an average dose reduction between 27% and 70% for the new Stellar detector, which is equivalent to using IR instead of FBP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE The goal of this study was to investigate whether different computed tomography (CT) energy levels could supply additional information for the differentiation of dental materials for forensic investigations. METHODS Nine different commonly used restorative dental materials were investigated in this study. A total of 75 human third molars were filled with the restorative dental materials and then scanned using the forensic reference phantom in singlesource mode. The mean Hounsfield unit values and standard deviations (SDs) of each material were calculated at 120, 80 and 140 kVp. RESULTS Most of the dental materials could be differentiated at 120 kVp. We found that greater X-ray density of a material resulted in higher SDs and that the material volume could influence the measurements. CONCLUSION Differentiation of dental materials in CT was possible in many cases using single-energy CT scans at 120 kVp. Because of the number of dental restorative materials available and scanner and scan parameter dependence, as well as the CT imaging artifacts, the identification (in contrast to differentiation) was problematic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This presentation was made at the Connecticut State Library Service Center, Willimantic, CT, April 14, 2009. It focused on digital capture workflows for both archival and derivative image creation using accepted current standards. Tools used were inexpensive by choice and focused towards the needs of small to mid-sized cultural heritage institutions who wish to begin digital capture in their own facilities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abel Pfeffermann-Pann

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Camille Pissaro

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. Investigations into the shortcomings of current intracavitary brachytherapy (ICBT) technology has lead us to design an Anatomically Adaptive Applicator (A3). The goal of this work was to design and characterize the imaging and dosimetric capabilities of this device. The A3 design incorporates a single shield that can both rotate and translate within the colpostat. We hypothesized that this feature, coupled with specific A3 component construction materials and imaging techniques, would facilitate artifact-free CT and MR image acquisition. In addition, by shaping the delivered dose distribution via the A3 movable shield, dose delivered to the rectum will be less compared to equivalent treatments utilizing current state-of-the-art ICBT applicators. ^ Method and materials. A method was developed to facilitate an artifact-free CT imaging protocol that used a "step-and-shoot" technique: pausing the scanner midway through the scan and moving the A 3 shield out of the path of the beam. The A3 CT imaging capabilities were demonstrated acquiring images of a phantom that positioned the A3 and FW applicators in a clinically-applicable geometry. Artifact-free MRI imaging was achieved by utilizing MRI-compatible ovoid components and pulse-sequences that minimize susceptibility artifacts. Artifacts were qualitatively compared, in a clinical setup. For the dosimetric study, Monte-Carlo (MC) models of the A3 and FW (shielded and unshielded) applicators were validated. These models were incorporated into a MC model of one cervical cancer patient ICBT insertion, using 192Ir (mHDR v2 source). The A3 shield's rotation and translation was adjusted for each dwell position to minimize dose to the rectum. Superposition of dose to rectum for all A3 dwell sources (4 per ovoid) was applied to obtain a comparison of equivalent FW treatments. Rectal dose-volume histograms (absolute and HDR/PDR biologically effective dose (BED)) and BED to 2 cc (BED2cc ) were determined for all applicators and compared. ^ Results. Using a "step-and-shoot" CT scanning method and MR compliant materials and optimized pulse-sequences, images of the A 3 were nearly artifact-free for both modalities. The A3 reduced BED2cc by 18.5% and 7.2% for a PDR treatment and 22.4% and 8.7% for a HDR treatment compared to treatments delivered using an uFW and sFW applicator, respectively. ^ Conclusions. The novel design of the A3 facilitated nearly artifact-free image quality for both CT and MR clinical imaging protocols. The design also facilitated a reduction in BED to the rectum compared to equivalent ICBT treatments delivered using current, state-of-the-art applicators. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rapid scan electron paramagnetic resonance (EPR) was developed in the Eaton laboratory at the University of Denver. Applications of rapid scan to wider spectra, such as for immobilized nitroxides, spin-labeled proteins, irradiated tooth and fingernail samples were demonstrated in this dissertation. The scan width has been increased from 55 G to 160 G. The signal to noise (S/N) improvement for slowly tumbling spin-labeled protein samples that is provided by rapid scan EPR will be highly advantageous for biophysical studies. With substantial improvement in S/N by rapid scan, the dose estimation for irradiated tooth enamels became more reliable than the traditional continuous wave (CW) EPR. An alternate approach of rapid scan, called field-stepped direct detection EPR, was developed to reconstruct wider EPR signals. A Mn2+ containing crystal was measured by field-stepped direct detection EPR, which had a spectrum more than 6000 G wide. Since the field-stepped direct detection extends the advantages of rapid scan to much wider scan ranges, this methodology has a great potential to replace the traditional CW EPR. With recent advances in digital electronics, a digital rapid scan spectrometer was built based on an arbitrary waveform generator (AWG), which can excite spins and detect EPR signals with a fully digital system. A near-baseband detection method was used to acquire the in-phase and quadrature signals in one physical channel. The signal was analyzed digitally to generate ideally orthogonal quadrature signals. A multiharmonic algorithm was developed that employed harmonics of the modulation frequencies acquired in the spectrometer transient mode. It was applied for signals with complicated lineshapes, and can simplify the selection of modulation amplitude. A digital saturation recovery system based on an AWG was built at X-band (9.6 GHz). To demonstrate performance of the system, the spin-lattice relaxation time of a fused quartz rod was measured at room temperature with fully digital excitation and detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On se propose, à travers cette étude de cartographier la végétation halo résistante et halophile de deux zones de l’Algérie occidentale l’une au Nord (région de Hammam Boughrara) et l’autre au Sud (région du Chott El-Gharbi). Une comparaison de ces deux zones d’un point de vue physionomique a été menée, afin de mettre en évidence la diversité phytoécologique de ces peuplements. Les données bioclimatiques montrent que les zones d’étude sont toutes deux caractérisées par une longue période de sécheresse estivale variant de 6 à 7 mois. D’un autre côté, l’approche édaphique montre une texture limono-sableuse à sableuse aussi bien au Nord qu’au Sud. Par contre la salinité est nettement plus accentuée au Sud atteignant 1350 μ.S/cm. La carte physionomique de la végétation de la zone nord fait apparaitre la dominance de formations pures à Tamarix gallica L. (27,13%) ou à Atriplex halimus L. (37,99%), et de formations en mosaïques, où les deux genres se trouvent mêlés (16,87%). Au niveau de la zone sud deux grandes unités physionomiques se distinguent: les groupements à Salsola vermiculata L. (24 %) et les groupements à Lygeum spartum L. (6 %). Les groupements à Artemisia herba– alba Asso. occupent par contre de petites surfaces (2 %) de qualité moyenne à médiocre. Les peuplements à Arthrocnemum glaucum (Del.) Ung. quant à eux, se répartissent tout autour de la daya du Chott El-Gharbi, où la salinité est à son maximum, en constituant un tapis végétal assez dense (1 %).